Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int J Pharm ; 643: 123232, 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37460049

RESUMO

During the last decades, there has been growing interest in the application of functionalized mesoporous nanomaterials as stimuli-responsive carriers for drug delivery. However, at present there is not a standardized methodology to evaluate their performance. The limitations of the different techniques reported in literature give rise to the necessity for new, simple, and cost-effective alternatives. This work constitutes a step forward in the development of advanced in vitro procedures for testing the behavior of nanocarriers, proposing a novel microfluidic platform. To test the capacity of the reported tool, the performance of amino-functionalized MCM-41 nanoparticles has been assessed. These materials show a pH-responsive mechanism, which prevents the drug release at acidic conditions, maximizing its distribution at neutral pH, thus, the selected release medium mimicked gastrointestinal conditions. As a first approximation, the delivery of Ru(bipy)32+ was evaluated, proving the advantages of the proposed microfluidic system: i) continuous flow of particles and media, ii) rigorous control of the residence time, temperature and pH, iii) enhanced mixing, iv) possibility to simulate different human body conditions and, v) possible integration with the continuous synthesis of nanocarriers. Finally, the microfluidic tool was used to analyze the delivery of the anti-inflammatory drug ibuprofen.


Assuntos
Portadores de Fármacos , Nanopartículas , Humanos , Microfluídica , Sistemas de Liberação de Medicamentos , Dióxido de Silício , Concentração de Íons de Hidrogênio , Liberação Controlada de Fármacos
2.
J Chem Inf Model ; 63(8): 2495-2504, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-37026789

RESUMO

The globally expanding threat of antibiotic resistance calls for the development of new strategies for abating Gram-negative bacterial infections. The use of extracorporeal blood cleansing devices with affinity sorbents to selectively capture bacterial lipopolysaccharide (LPS), which is the major constituent of Gram-negative bacterial outer membranes and the responsible agent for eliciting an exacerbated innate immune response in the host during infection, has received outstanding interest. For that purpose, molecules that bind tightly to LPS are required to functionalize the affinity sorbents. Particularly, anti-LPS factors (ALFs) are promising LPS-sequestrating molecules. Hence, in this work, molecular dynamics (MD) simulations are used to investigate the interaction mechanism and binding pose of the ALF isoform 3 from Penaeus monodon (ALFPm3), which is referred to as "AL3" for the sake of simplicity, and lipid A (LA, the component of LPS that represents its endotoxic principle). We concluded that hydrophobic interactions are responsible for AL3-LA binding and that LA binds to AL3 within the protein cavity, where it buries its aliphatic tails, whereas the negatively charged phosphate groups are exposed to the medium. AL3 residues that are key for its interaction with LA were identified, and their conservation in other ALFs (specifically Lys39 and Tyr49) was also analyzed. Additionally, based on the MD-derived results, we provide a picture of the possible AL3-LA interaction mechanism. Finally, an in vitro validation of the in silico predictions was performed. Overall, the insights gained from this work can guide the design of novel therapeutics for treating sepsis, since they may be significantly valuable for designing LPS-sequestrating molecules that could functionalize affinity sorbents to be used for extracorporeal blood detoxification.


Assuntos
Lipídeo A , Penaeidae , Animais , Lipopolissacarídeos/farmacologia , Penaeidae/metabolismo , Penaeidae/microbiologia , Simulação de Dinâmica Molecular , Isoformas de Proteínas/metabolismo
3.
Comput Struct Biotechnol J ; 20: 5886-5901, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36382192

RESUMO

Lipopolysaccharide (LPS), a main component of the outer membrane of Gram-negative bacteria, has crucial implications on both antibiotic resistance and the overstimulation of the host innate immune system. Fighting against these global concerns calls for the molecular understanding of the barrier function and immunostimulatory ability of LPS. Molecular dynamics (MD) simulations have become an invaluable tool for uncovering important findings in LPS research. While the reach of MD simulations for investigating the immunostimulatory ability of LPS has been already outlined, little attention has been paid to the role of MD simulations for exploring its barrier function and synthesis. Herein, we give an overview about the impact of MD simulations on gaining insight into the shield role and synthesis pathway of LPS, which have attracted considerable attention to discover molecules able to surmount antibiotic resistance, either circumventing LPS defenses or disrupting its synthesis. We specifically focus on the enhanced sampling and free energy calculation methods that have been combined with MD simulations to address such research. We also highlight the use of special-purpose MD supercomputers, the importance of appropriate LPS and ions parameterization to obtain reliable results, and the complementary views that MD and wet-lab experiments provide. Thereby, this work, which covers the last five years of research, apart from outlining the phenomena and strategies that are being explored, evidences the valuable insights that are gained by MD, which may be useful to advance antibiotic design, and what the prospects of this in silico method could be in LPS research.

4.
Ind Eng Chem Res ; 60(46): 16780-16790, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34866775

RESUMO

The design of microdevices in which components with magnetic character must be separated and recovered from reactive media benefits from the advantages of microfluidics and meets the criteria for process intensification; however, there are open questions, such as the design of the most appropriate magnet arrangement, that need further research in order to increase the magnetic gradient exerted on the particles. Herein, we focus on the continuous recovery of magnetic microparticles, that can be used as support to facilitate the recovery of biocatalysts (magnetic microcatalysts, MMCs) from biological fluids. We analyze and compare the performance of two typical magnetophoretic microdevices for addressing bead recovery: (i) annular channels with a quadrupole orientation of the permanent magnets (quadrupole magnetic sorter, QMS) and (ii) the standard design, which consists of rectangular channels with a single permanent magnet to generate the magnetic field. To this end, an experimentally validated computational fluid dynamics (CFD) numerical model has been employed. Our results reveal that for devices with the same width and length, the micro-QMS, in comparison to a rectangular channel, could accomplish the complete particle retrieval while (i) processing more than 4 times higher fluid velocities, treating more than 360 times higher flow rates or (ii) working with smaller particles, thus reducing by 55% the particle mass. Additionally, the parallel performance of ≈300 micro-QMSs fulfills the processing of flow rates as high as 200 L·h-1 while entirely capturing the magnetic beads. Thereby, this work shows the potential of the QMS advanced design in the intensification of the recovery of catalysts supports of magnetic character.

5.
J Chem Inf Model ; 61(10): 4839-4851, 2021 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-34559524

RESUMO

Lipopolysaccharide (LPS) is the primary component of the outer leaflet of Gram-negative bacterial outer membranes. LPS elicits an overwhelming immune response during infection, which can lead to life-threatening sepsis or septic shock for which no suitable treatment is available so far. As a result of the worldwide expanding multidrug-resistant bacteria, the occurrence and frequency of sepsis are expected to increase; thus, there is an urge to develop novel strategies for treating bacterial infections. In this regard, gaining an in-depth understanding about the ability of LPS to both stimulate the host immune system and interact with several molecules is crucial for fighting against LPS-caused infections and allowing for the rational design of novel antisepsis drugs, vaccines and LPS sequestration and detection methods. Molecular dynamics (MD) simulations, which are understood as being a computational microscope, have proven to be of significant value to understand LPS-related phenomena, driving and optimizing experimental research studies. In this work, a comprehensive review on the methods that can be combined with MD simulations, recently applied in LPS research, is provided. We focus especially on both enhanced sampling methods, which enable the exploration of more complex systems and access to larger time scales, and free energy calculation approaches. Thereby, apart from outlining several strategies for surmounting LPS-caused infections, this work reports the current state-of-the-art of the methods applied with MD simulations for moving a step forward in the development of such strategies.


Assuntos
Infecções Bacterianas , Sepse , Membrana Externa Bacteriana , Humanos , Lipopolissacarídeos/toxicidade , Simulação de Dinâmica Molecular , Sepse/tratamento farmacológico
6.
Soft Matter ; 16(41): 9506-9518, 2020 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-32966533

RESUMO

We present a numerical model that describes the microfluidic generation and manipulation of ferrofluid droplets under an external magnetic field. We developed a numerical Computational Fluid Dynamics (CFD) analysis for predicting and optimizing continuous flow generation and processing of ferrofluid droplets with and without the presence of a permanent magnet. More specifically, we explore the dynamics of oil-based ferrofluid droplets within an aqueous continuous phase under an external inhomogeneous magnetic field. The developed model determines the effect of the magnetic field on the droplet generation, which is carried out in a flow-focusing geometry, and its sorting in T-junction channels. Three-channel depths (25 µm, 30 µm, and 40 µm) were investigated to study droplet deformation under magnetic forces. Among the three, the 30 µm channel depth showed the most consistent droplet production for the studied range of flow rates. Ferrofluids with different loadings of magnetic nanoparticles were used to observe the behavior for different ratios of magnetic and hydrodynamic forces. Our results show that the effect of these factors on droplet size and generation rate can be tuned and optimized to produce consistent droplet generation and sorting. This approach involves fully coupled magnetic-fluid mechanics models and can predict critical details of the process including droplet size, shape, trajectory, dispensing rate, and the perturbation of the fluid co-flow for different flow rates. The model enables better understanding of the physical phenomena involved in continuous droplet processing and allows efficient parametric analysis and optimization.

7.
Sensors (Basel) ; 20(11)2020 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-32471054

RESUMO

The use of functionalized magnetic particles for the detection or separation of multiple chemicals and biomolecules from biofluids continues to attract significant attention. After their incubation with the targeted substances, the beads can be magnetically recovered to perform analysis or diagnostic tests. Particle recovery with permanent magnets in continuous-flow microdevices has gathered great attention in the last decade due to the multiple advantages of microfluidics. As such, great efforts have been made to determine the magnetic and fluidic conditions for achieving complete particle capture; however, less attention has been paid to the effect of the channel geometry on the system performance, although it is key for designing systems that simultaneously provide high particle recovery and flow rates. Herein, we address the optimization of Y-Y-shaped microchannels, where magnetic beads are separated from blood and collected into a buffer stream by applying an external magnetic field. The influence of several geometrical features (namely cross section shape, thickness, length, and volume) on both bead recovery and system throughput is studied. For that purpose, we employ an experimentally validated Computational Fluid Dynamics (CFD) numerical model that considers the dominant forces acting on the beads during separation. Our results indicate that rectangular, long devices display the best performance as they deliver high particle recovery and high throughput. Thus, this methodology could be applied to the rational design of lab-on-a-chip devices for any magnetically driven purification, enrichment or isolation.


Assuntos
Sangue , Magnetismo , Imãs , Humanos , Dispositivos Lab-On-A-Chip , Microfluídica/instrumentação
8.
Crit Rev Biotechnol ; 40(3): 292-305, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31931630

RESUMO

Lipopolysaccharide (LPS), the major component of the outer membrane of Gram-negative bacteria, often pose a serious risk not only when delivered in the bloodstream but also in air, the environment and several industrial fields such as pharmaceutics or food. LPS is constituted of three regions; the O-specific chain, the core region and the lipid A, which is the responsible segment of the toxicity. Previous literature dealt with the study of lipid A, its potential ligands as well as the mechanisms of Lipid A interactions that, among other applications, establish the basis for detection methods such as Limulus Amebocyte Lysate (LAL) assays and emerging biosensoring techniques. However, quantifying LPS binding affinity is an urgent need that still requires thorough studies. In this context, this work reviews the molecules that bind LPS, highlighting quantitative affinity parameters. Moreover, state of the art methods to analyze the affinity and kinetics of lipid-ligand interactions are also reviewed and different techniques have been briefly described. Thus, first, we review existing information on LPS ligands, classifying them into three main groups and targeting the comparison of molecules in terms of their interaction affinities and, second, we establish the basis for further research aimed at the development of effective methods for LPS detection and removal.


Assuntos
Proteínas de Transporte/metabolismo , Lipopolissacarídeos/metabolismo , Proteínas de Membrana/metabolismo , Bactérias Gram-Negativas/metabolismo , Humanos , Sistema Imunitário/metabolismo , Lipídeo A/metabolismo , Conformação Proteica
9.
Sci Rep ; 9(1): 7265, 2019 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-31086252

RESUMO

In this work, we report a numerical flow-focused study of bead magnetophoresis inside a continuous-flow microchannel in order to provide a detailed analysis of bead motion and its effect on fluid flow. The numerical model involves a Lagrangian approach and predicts the bead separation from blood and their collection into a flowing buffer by the application of a magnetic field generated by a permanent magnet. The following scenarios are modelled: (i) one-way coupling wherein momentum is transferred from the fluid to beads, which are treated as point particles, (ii) two-way coupling wherein the beads are treated as point particles and momentum is transferred from the bead to the fluid and vice versa, and (iii) two-way coupling taking into account the effects of bead volume in fluid displacement. The results indicate that although there is little difference in the bead trajectories for the three scenarios, there is significant variation in the flow fields, especially when high magnetic forces are applied on the beads. Therefore, an accurate full flow-focused model that takes into account the effects of the bead motion and volume on the flow field should be solved when high magnetic forces are employed. Nonetheless, when the beads are subjected to medium or low magnetic forces, computationally inexpensive models can be safely employed to model magnetophoresis.


Assuntos
Campos Magnéticos , Técnicas Analíticas Microfluídicas/métodos , Microesferas , Humanos
10.
Lab Chip ; 18(11): 1593-1606, 2018 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-29748668

RESUMO

Magnetic beads can be functionalized to capture and separate target pathogens from blood for extracorporeal detoxification. The beads can be magnetically separated from a blood stream and collected into a coflowing buffer solution using a two-phase liquid-liquid continuous-flow microfluidic device in the presence of an external field. However, device design and process optimization, i.e. high bead recovery with minimum blood loss or dilution remain a substantial technological challenge. We introduce a CFD-based Eulerian-Lagrangian computational model that enables the rational design and optimization of such systems. The model takes into account dominant magnetic and hydrodynamic forces on the beads as well as coupled bead-fluid interactions. Fluid flow (Navier-Stokes equations) and mass transfer (Fick's law) between the coflowing fluids are solved numerically, while the magnetic force on the beads is predicted using analytical methods. The model is demonstrated via application to a prototype device and used to predict key performance metrics; degree of bead separation, flow patterns, and mass transfer, i.e. blood diffusion to the buffer phase. The impact of different process variables and parameters - flow rates, bead and magnet dimensions and fluid viscosities - on both bead recovery and blood loss or dilution is quantified for the first time. The performance of the prototype device is characterized using fluorescence microscopy and the experimental results are found to match theoretical predictions within an absolute error of 15%. While the model is demonstrated here for analysis of a detoxification device, it can be readily adapted to a broad range of magnetically-enabled microfluidic applications, e.g. bioseparation, sorting and sensing.


Assuntos
Simulação por Computador , Magnetismo/instrumentação , Microscopia de Fluorescência , Desintoxicação por Sorção , Células Sanguíneas/citologia , Fenômenos Fisiológicos Sanguíneos , Desenho de Equipamento , Humanos , Técnicas Analíticas Microfluídicas , Microesferas , Desintoxicação por Sorção/instrumentação , Desintoxicação por Sorção/métodos
11.
Lab Chip ; 17(22): 3934, 2017 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-29085923

RESUMO

Correction for 'On-chip polyelectrolyte coating onto magnetic droplets - towards continuous flow assembly of drug delivery capsules' by Ali Q. Alorabi et al., Lab Chip, 2017, DOI: 10.1039/c7lc00918f.

12.
Lab Chip ; 17(22): 3785-3795, 2017 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-28991297

RESUMO

Polyelectrolyte (PE) microcapsules for drug delivery are typically fabricated via layer-by-layer (LbL) deposition of PE layers of alternating charge on sacrificial template microparticles, which usually requires multiple incubation and washing steps that render the process repetitive and time-consuming. Here, ferrofluid droplets were explored for this purpose as an elegant alternative of templates that can be easily manipulated via an external magnetic field, and require only a simple microfluidic chip design and setup. Glass microfluidic devices featuring T-junctions or flow focusing junctions for the generation of oil-based ferrofluid droplets in an aqueous continuous phase were investigated. Droplet size was controlled by the microfluidic channel dimensions as well as the flow rates of the ferrofluid and aqueous phases. The generated droplets were stabilised by a surface active polymer, polyvinylpyrrolidone (PVP), and then guided into a chamber featuring alternating, co-laminar PE solutions and wash streams, and deflected across them by means of an external permanent magnet. The extent of droplet deflection was tailored by the flow rates, the concentration of magnetic nanoparticles in the droplets, and the magnetic field strength. PVP-coated ferrofluid droplets were deflected through solutions of polyelectrolyte and washing streams using several iterations of multilaminar flow designs. This culminated in an innovative "Snakes-and-Ladders" inspired microfluidic chip design that overcame various issues of the previous iterations for the deposition of layers of anionic poly(sodium-4-styrene sulfonate) (PSS) and cationic poly(fluorescein isothiocyanate allylamine hydrochloride) (PAH-FITC) onto the droplets. The presented method demonstrates a simple and rapid process for PE layer deposition in <30 seconds, and opens the way towards rapid layer-by-layer assembly of PE microcapsules for drug delivery applications.


Assuntos
Cápsulas , Sistemas de Liberação de Medicamentos/instrumentação , Nanopartículas de Magnetita/química , Técnicas Analíticas Microfluídicas/instrumentação , Polieletrólitos/química , Cápsulas/síntese química , Cápsulas/química , Desenho de Equipamento , Dispositivos Lab-On-A-Chip , Tamanho da Partícula
13.
J Environ Manage ; 162: 306-25, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-26265600

RESUMO

Chronic contamination of groundwaters by both arsenic (As) and fluoride (F) is frequently observed around the world, which has severely affected millions of people. Fluoride and As are introduced into groundwaters by several sources such as water-rock interactions, anthropogenic activities, and groundwater recharge. Coexistence of these pollutants can have adverse effects due to synergistic and/or antagonistic mechanisms leading to uncertain and complicated health effects, including cancer. Many developing countries are beset with the problem of F and As laden waters, with no affordable technologies to provide clean water supply. The technologies available for the simultaneous removal are akin to chemical treatment, adsorption and membrane processes. However, the presence of competing ions such as phosphate, silicate, nitrate, chloride, carbonate, and sulfate affect the removal efficiency. Highly efficient, low-cost and sustainable technology which could be used by rural populations is of utmost importance for simultaneous removal of both pollutants. This can be realized by using readily available low cost materials coupled with proper disposal units. Synthesis of inexpensive and highly selective nanoadsorbents or nanofunctionalized membranes is required along with encapsulation units to isolate the toxicant loaded materials to avoid their re-entry in aquifers. A vast number of reviews have been published periodically on removal of As or F alone. However, there is a dearth of literature on the simultaneous removal of both. This review critically analyzes this important issue and considers strategies for their removal and safe disposal.


Assuntos
Arsênio/química , Fluoretos/química , Água Subterrânea/química , Poluentes Químicos da Água/química , Purificação da Água/métodos , Adsorção , Arsênio/análise , Fluoretos/análise , Poluentes Químicos da Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA