Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Dent Res ; 85(5): 473-8, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16632764

RESUMO

An implant-abutment interface at the alveolar bone crest is associated with sustained peri-implant inflammation; however, whether magnitude of inflammation is proportionally dependent upon interface position remains unknown. This study compared the distribution and density of inflammatory cells surrounding implants with a supracrestal, crestal, or subcrestal implant-abutment interface. All implants developed a similar pattern of peri-implant inflammation: neutrophilic polymorphonuclear leukocytes (neutrophils) maximally accumulated at or immediately coronal to the interface. However, peri-implant neutrophil accrual increased progressively as the implant-abutment interface depth increased, i.e., subcrestal interfaces promoted a significantly greater maximum density of neutrophils than did supracrestal interfaces (10,512 +/- 691 vs. 2398 +/- 1077 neutrophils/mm(2)). Moreover, inflammatory cell accumulation below the original bone crest was significantly correlated with bone loss. Thus, the implant-abutment interface dictates the intensity and location of peri-implant inflammatory cell accumulation, a potential contributing component in the extent of implant-associated alveolar bone loss.


Assuntos
Perda do Osso Alveolar/etiologia , Implantação Dentária Endóssea/efeitos adversos , Implantes Dentários/efeitos adversos , Periodontite/etiologia , Animais , Dente Suporte , Planejamento de Prótese Dentária/efeitos adversos , Cães , Contagem de Leucócitos , Masculino , Doenças Mandibulares/etiologia , Neutrófilos , Estatísticas não Paramétricas
2.
J Biomed Mater Res A ; 78(2): 291-7, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16637025

RESUMO

The functional capacity of osseointegrated dental implants to bear load is largely dependent on the quality of the interface between the bone and implant. Sandblasted and acid-etched (SLA) surfaces have been previously shown to enhance bone apposition. In this study, the SLA has been compared with a chemically modified SLA (modSLA) surface. The increased wettability of the modSLA surface in a protein solution was verified by dynamic contact angle analysis. Using a well-established animal model with a split-mouth experimental design, implant removal torque testing was performed to determine the biomechanical properties of the bone-implant interface. All implants had an identical cylindrical shape with a standard thread configuration. Removal torque testing was performed after 2, 4, and 8 weeks of bone healing (n = 9 animals per healing period, three implants per surface type per animal) to evaluate the interfacial shear strength of each surface type. Results showed that the modSLA surface was more effective in enhancing the interfacial shear strength of implants in comparison with the conventional SLA surface during early stages of bone healing. Removal torque values of the modSLA-surfaced implants were 8-21% higher than those of the SLA implants (p = 0.003). The mean removal torque values for the modSLA implants were 1.485 N m at 2 weeks, 1.709 N m at 4 weeks, and 1.345 N m at 8 weeks; and correspondingly, 1.231 N m, 1.585 N m, and 1.143 N m for the SLA implants. The bone-implant interfacial stiffness calculated from the torque-rotation curve was on average 9-14% higher for the modSLA implants when compared with the SLA implants (p = 0.038). It can be concluded that the modSLA surface achieves a better bone anchorage during early stages of bone healing than the SLA surface; chemical modification of the standard SLA surface likely enhances bone apposition and this has a beneficial effect on the interfacial shear strength.


Assuntos
Implantes Dentários , Titânio/química , Materiais Biocompatíveis , Parafusos Ósseos , Resistência ao Cisalhamento , Propriedades de Superfície , Torque
3.
J Dent Res ; 83(7): 529-33, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15218041

RESUMO

Increased surface roughness of dental implants has demonstrated greater bone apposition; however, the effect of modifying surface chemistry remains unknown. In the present study, we evaluated bone apposition to a modified sandblasted/acid-etched (modSLA) titanium surface, as compared with a standard SLA surface, during early stages of bone regeneration. Experimental implants were placed in miniature pigs, creating 2 circular bone defects. Test and control implants had the same topography, but differed in surface chemistry. We created the test surface by submerging the implant in an isotonic NaCl solution following acid-etching to avoid contamination with molecules from the atmosphere. Test implants demonstrated a significantly greater mean percentage of bone-implant contact as compared with controls at 2 (49.30 vs. 29.42%; p = 0.017) and 4 wks (81.91 vs. 66.57%; p = 0.011) of healing. At 8 wks, similar results were observed. It is concluded that the modSLA surface promoted enhanced bone apposition during early stages of bone regeneration.


Assuntos
Implantação Dentária Endóssea/instrumentação , Implantes Dentários , Planejamento de Prótese Dentária , Maxila/cirurgia , Osseointegração/fisiologia , Titânio/fisiologia , Animais , Regeneração Óssea/fisiologia , Materiais Revestidos Biocompatíveis/química , Implantação Dentária Endóssea/métodos , Maxila/anatomia & histologia , Metalurgia , Propriedades de Superfície , Suínos , Porco Miniatura , Titânio/química , Cicatrização/fisiologia
4.
J Dent Res ; 82(3): 232-7, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12598555

RESUMO

The inflammatory response adjacent to implants has not been well-investigated and may influence peri-implant tissue levels. The purpose of this study was to assess, histomorphometrically, (1) the timing of abutment connection and (2) the influence of a microgap. Three implant designs were placed in the mandibles of dogs. Two-piece implants were placed at the alveolar crest and abutments connected either at initial surgery (non-submerged) or three months later (submerged). The third implant was one-piece. Adjacent interstitial tissues were analyzed. Both two-piece implants resulted in a peak of inflammatory cells approximately 0.50 mm coronal to the microgap and consisted primarily of neutrophilic polymorphonuclear leukocytes. For one-piece implants, no such peak was observed. Also, significantly greater bone loss was observed for both two-piece implants compared with one-piece implants. In summary, the absence of an implant-abutment interface (microgap) at the bone crest was associated with reduced peri-implant inflammatory cell accumulation and minimal bone loss.


Assuntos
Dente Suporte/efeitos adversos , Implantação Dentária Endóssea/efeitos adversos , Implantação Dentária Endóssea/métodos , Implantes Dentários/efeitos adversos , Periodontite/etiologia , Análise de Variância , Animais , Planejamento de Prótese Dentária/efeitos adversos , Cães , Análise dos Mínimos Quadrados , Contagem de Leucócitos , Leucócitos Mononucleares , Mandíbula , Neutrófilos , Periodontite/imunologia , Periodontite/patologia , Distribuição Aleatória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA