Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 92(5): 053529, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243238

RESUMO

The Joint European Torus (JET) gamma-ray camera has been recently upgraded with the installation of new gamma-ray detectors, based on LaBr3(Ce) scintillation crystals, which add spectroscopic capability to the existing system allowing measurements with good energy resolution (5% at 0.622 MeV), a dynamic range from hundreds of keV up to about 30 MeV, and high counting rate capabilities of MCps. First gamma-ray measurements during the C38 campaign of the JET have been successfully carried out, in particular, in D-3He plasmas from three-ion ion cyclotron resonance heating experiments, where the detection of 16.4 MeV γ-rays from D + 3He → γ + 5Li reactions with the gamma-ray camera upgrade allowed determining the spatial profile of alpha particles born in D + 3He fusion reactions.

2.
Rev Sci Instrum ; 89(10): 10I116, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399923

RESUMO

The JET gamma-ray cameras have been recently upgraded within the gamma-ray camera upgrade project in support of development of JET high performance deuterium plasma scenarios and in preparation of deuterium-tritium experiments. New, dedicated detectors based on a LaBr3 crystal and silicon photo-multipliers have been developed and replaced pre-existing CsI detectors in all 19 channels. The new instrument gives opportunity of making two-dimensional gamma-ray measurements with a counting rate capability exceeding 1 MCounts/s (MCps) and energy resolution better than 5% at 1.1 MeV. The upgrade is of relevance for fast ion and runaway electron physics studies in high performance deuterium discharges and also in plasmas with tritium at neutron yields in the range up to about 5 × 1017 n/s.

3.
Rev Sci Instrum ; 87(11): 11E714, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910625

RESUMO

Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr3 scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.