1.
Hum Factors ; : 187208221075851, 2022 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-35466744

RESUMO

OBJECTIVE: In two experiments, we examined how quickly different visual alerts on a head-worn display (HWD) would capture participants' attention to a matrix of patient vital sign values, while multitasking. BACKGROUND: An HWD could help clinicians monitor multiple patients, regardless of where the clinician is located. We sought effective ways for HWDs to alert multitasking wearers to important events. METHODS: In two preclinical experiments, university student participants performed a visuomotor tracking task while simultaneously monitoring simulated patient vital signs on an HWD to detect abnormal values. Methods to attract attention to abnormal values included highlighting abnormal vital signs and imposing a white flash over the entire display. RESULTS: Experiment 1 found that participants detected abnormal values faster with high contrast than low contrast greyscale highlights, even while performing difficult tracking. In Experiment 2, a white flash of the entire screen quickly and reliably captured attention to vital signs, but less so on an HWD than on a conventional screen. CONCLUSION: Visual alerts on HWDs can direct users' attention to patient transition events (PTEs) even under high visual-perceptual load, but not as quickly as visual alerts on fixed displays. Aspects of the results have since been tested in a healthcare context. APPLICATION: Potential applications include informing the design of HWD interfaces for monitoring multiple processes and informing future research on capturing attention to HWDs.

2.
Appl Ergon ; 56: 160-9, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27184324

RESUMO

Recent guidelines recommend oxygen saturation (SpO2) levels of 90%-95% for preterm neonates on supplemental oxygen but it is difficult to discern such levels with current pulse oximetry sonifications. We tested (1) whether adding levels of tremolo to a conventional log-linear pulse oximetry sonification would improve identification of SpO2 ranges, and (2) whether adding a beacon reference tone to conventional pulse oximetry confuses listeners about the direction of change. Participants using the Tremolo (94%) or Beacon (81%) sonifications identified SpO2 range significantly more accurately than participants using the LogLinear sonification (52%). The Beacon sonification did not confuse participants about direction of change. The Tremolo sonification may have advantages over the Beacon sonification for monitoring SpO2 of preterm neonates, but both must be further tested with clinicians in clinically representative scenarios, and with different levels of ambient noise and distractions.


Assuntos
Percepção Auditiva , Alarmes Clínicos , Recém-Nascido Prematuro , Oxigênio/sangue , Adolescente , Feminino , Humanos , Recém-Nascido , Masculino , Monitorização Fisiológica , Música , Oximetria , Oxigenoterapia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA