Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 10(34): 28351-28360, 2018 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-30067019

RESUMO

Freestanding, vertically aligned carbon nanotubes (VACNTs) were patterned into 16 µm diameter microchannel arrays for flow-through electrochemical glucose sensing. Non-enzymatic sensing of glucose was achieved by the chemical reaction of glucose with methyl viologen (MV) at an elevated temperature and pH (0.1 M NaOH), followed by the electrochemical reaction of reduced-MV with the VACNT surface. The MV sensor required no functionalization (including no metal) and was able to produce on average 3.4 electrons per glucose molecule. The current density of the MV sensor was linear with both flow rate and glucose concentration. Challenges with interference chemicals were mitigated by operating at a low potential of -0.2 V vs Ag/AgCl. As a comparison, enzymatic VACNT sensors with platinum nano-urchins were functionalized with glucose oxidase by covalent binding (1-ethyl-3-(-3-dimethylaminopropyl)carbodiimide/ N-hydroxysuccinimide) or by polymer entrapment [poly(3,4-ethylene-dioxythiophene)] and operated in phosphate buffered saline. With normalization by the overall cross-sectional area of the flow (0.713 cm2), the sensitivity of the MV, enzyme-in-solution, and covalent sensors were 45.93, 18.77, and 1.815 mA cm-2 mM-1, respectively. Corresponding limits of detection were 100, 194, and 311 nM glucose. The linear sensing ranges for the sensors were 250 nM to 200 µM glucose for the MV sensor, 500 nM to 200 µM glucose for the enzyme-in-solution sensor, and 1 µM to 6 mM glucose for the covalent sensor. The flow cell and sensor cross-sectional area were scaled down (0.020 cm2) to enable detection from 200 µL of glucose with MV by flow injection analysis. The sensitivity of the small MV sensor was 5.002 mA cm-2 mM-1, with a limit of detection of 360 nM glucose and a linear range up to at least 150 µM glucose. The small MV sensor has the potential to measure glucose levels found in 200 µL of saliva.


Assuntos
Nanotubos de Carbono , Técnicas Biossensoriais , Glucose , Glucose Oxidase , Paraquat , Platina
2.
Biosens Bioelectron ; 117: 68-74, 2018 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-29886188

RESUMO

Vertically aligned carbon nanotube array (VANTA) coatings have recently garnered significant attention due in part to their unique material properties including light absorption, chemical inertness, and electrical conductivity. Herein we report the first use of VANTAs grown via chemical vapor deposition in a 2D interdigitated electrode (IDE) footprint with a high height-to-width aspect ratio (3:1 or 75:25 µm). The VANTA-IDEs were functionalized with an antibody (Ab) specific to the human cancerous inhibitor PP2A (CIP2A)-an oncoprotein that is associated with a variety of malignancies such as oral, breast, and multiple myeloma cancers. The resultant label-free immunosensor was capable of detecting CIP2A across a wide linear sensing range (1-100 pg/mL) with a detection limit of 0.24 pg/mL within saliva supernatant-a range that is more sensitive than the corresponding CIP2A enzyme linked immunosorbent assay (ELISA). These results help pave the way for rapid cancer screening tests at the point-of-care (POC) such as for the early-stage diagnosis of oral cancer at a dentist's office.


Assuntos
Autoantígenos/metabolismo , Técnicas Biossensoriais/métodos , Detecção Precoce de Câncer/métodos , Proteínas de Membrana/metabolismo , Neoplasias Bucais/diagnóstico , Nanotubos de Carbono/química , Anticorpos/metabolismo , Técnicas Biossensoriais/normas , Eletrodos , Humanos , Peptídeos e Proteínas de Sinalização Intracelular , Limite de Detecção , Sistemas Automatizados de Assistência Junto ao Leito
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA