Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur J Obstet Gynecol Reprod Biol ; 171(2): 240-5, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24075447

RESUMO

OBJECTIVE: Iatrogenic preterm prelabour rupture of fetal membranes (iPPROM) remains the main complication after invasive interventions into the intrauterine cavity. The aim of this study was to evaluate the sealing capability and tissue interaction of mussel-mimetic tissue adhesive (mussel glue) in comparison to fibrin glue on punctured fetal membranes in vivo. STUDY DESIGN: A mid-gestational rabbit model was used for testing the materials. The fetal sacs of pregnant rabbits at day 23 were randomly assigned into experimental groups: unoperated (negative control), unclosed puncture (positive control), commercially available fibrin glue (FG) with decellularized amnion scaffold (DAM), mussel glue (MG) with DAM, or mussel glue alone. Evaluation was done at term (30 days' gestation) assessing fetal survival, fetal membrane integrity and histology of the membranes. RESULTS: Fetal survival was not significantly lower in any of the treatment groups compared to the negative control. All plugging materials could be found at the end of the pregnancy and no adverse effects on the fetus or the pregnant does could be observed. Sac integrity was higher in all treatment groups compared to the positive control group but significant only in the FG+DAM group. Cellular infiltration could be seen in fibrin glue and DAM in contrast to mussel glue which was only tightly adhering to the surrounding tissue. These cells were mostly of mesenchymal phenotype staining positive for vimentin. CD68 positive macrophages were found clustered around all the plugging materials, but their numbers were only significantly increased for the mussel glue alone group compared to negative controls. CONCLUSIONS: Mussel glues performance in sealing fetal membranes in the rabbit model was comparable to that of fibrin glue. Taking into account its other favorable properties, it is a noteworthy candidate for a clinically applicable fetal membrane sealant.


Assuntos
Catecóis/uso terapêutico , Membranas Extraembrionárias/cirurgia , Ruptura Prematura de Membranas Fetais/tratamento farmacológico , Polietilenoglicóis/uso terapêutico , Adesivos Teciduais/uso terapêutico , Animais , Bivalves , Feminino , Ruptura Prematura de Membranas Fetais/etiologia , Fetoscopia/efeitos adversos , Adesivo Tecidual de Fibrina , Doença Iatrogênica , Gravidez , Punções/efeitos adversos , Coelhos , Cicatrização
2.
Acta Biomater ; 8(12): 4365-70, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22885681

RESUMO

Iatrogenic preterm prelabor rupture of membranes (iPPROM) remains the main complication after invasive interventions into the intrauterine cavity. Here, the proteolytic stability of mussel-mimetic tissue adhesive (mussel glue) and its sealing behavior on punctured fetal membranes are evaluated. The proteolytic degradation of mussel glue and fibrin glue were compared in vitro. Critical pressures of punctured and sealed fetal membranes were determined under close to physiological conditions using a custom-made inflation device. An inverse finite element procedure was applied to estimate mechanical parameters of mussel glue. Mussel glue was insensitive whereas fibrin glue was sensitive towards proteolytic degradation. Mussel glue sealed 3.7mm fetal membrane defect up to 60mbar (45mmHg) when applied under wet conditions, whereas fibrin glue needed dry membrane surfaces for reliable sealing. The mussel glue can be represented by a neo-Hookean material model with elastic coefficient C(1)=9.63kPa. Ex-vivo-tested mussel glue sealed fetal membranes and resisted pressures achieved during uterine contractions. Together with good stability in proteolytic environments, this makes mussel glue a promising sealing material for future applications.


Assuntos
Materiais Biomiméticos/farmacologia , Membranas Extraembrionárias/lesões , Ruptura Prematura de Membranas Fetais/terapia , Teste de Materiais , Adesivos Teciduais/farmacologia , Adulto , Materiais Biomiméticos/química , Elasticidade , Membranas Extraembrionárias/metabolismo , Membranas Extraembrionárias/patologia , Feminino , Ruptura Prematura de Membranas Fetais/metabolismo , Ruptura Prematura de Membranas Fetais/patologia , Humanos , Gravidez , Adesivos Teciduais/química
3.
Prenat Diagn ; 31(7): 654-60, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21351279

RESUMO

OBJECTIVE: Iatrogenic preterm premature rupture of membranes (iPPROM), the main complication of invasive interventions in the prenatal period, seriously limits the benefit of diagnostic or surgical prenatal procedures. This study aimed to evaluate preventive plugging of punctured fetal membranes in an ex vivo situation using a new mussel-mimetic tissue adhesive (mussel glue) to inhibit leakage. METHODS: A novel biomechanical test device that tests the closure of injured membranes under near-physiological conditions was used. Mussel glue, a poly(ethylene glycol)-based hydrogel, was used to seal membrane defects of up to 3 mm in mechanically well-defined elastomeric membranes with three different degrees of stiffness. RESULTS: Elastomeric test membranes were successfully employed for testing mussel glue under well-defined conditions. Mussel glue plugs were distended by up to 94%, which translated to an improved sealing efficiency on elastomeric membranes with high stiffness. For the stiffest membrane tested, a critical burst pressure of 48 mbar (36 mmHg) was accomplished in this ex vivo setting. CONCLUSIONS: Mussel glue appears to efficiently seal membrane defects under well-standardized ex vivo conditions. As repaired membranes resist pressures measured in amniotic cavities, mussel glue might represent a novel sealing method for iatrogenic membrane defects.


Assuntos
Materiais Biomiméticos/uso terapêutico , Bivalves/metabolismo , Elastômeros , Membranas Extraembrionárias/efeitos dos fármacos , Ruptura Prematura de Membranas Fetais/tratamento farmacológico , Membranas Artificiais , Adesivos Teciduais/uso terapêutico , Animais , Bivalves/química , Células Cultivadas , Avaliação Pré-Clínica de Medicamentos/normas , Membranas Extraembrionárias/patologia , Feminino , Ruptura Prematura de Membranas Fetais/patologia , Humanos , Técnicas de Cultura de Órgãos/normas , Gravidez , Adesivos Teciduais/isolamento & purificação , Adesivos Teciduais/metabolismo , Cicatrização/efeitos dos fármacos
4.
J Rehabil Res Dev ; 36(1): 42-7, 1999 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10659893

RESUMO

An Ackerman steering linkage for short wheelbase, four-wheel vehicles has been developed. The linkage coordinates the steering angle of each wheel through a range of 180 degrees with minimal misalignment between wheels. Control of steering angles is accomplished using a single linear actuator. Control complexity is lower compared to four-wheel systems using individually controlled steering actuators for each wheel. A prototype linkage that provides a minimum turning radius while maintaining maximum stability has been developed and evaluated for a power wheelchair base. The single-actuator linkage is well suited for this application, due to the cost-sensitive nature of wheelchair products.


Assuntos
Cadeiras de Rodas/normas , Análise Custo-Benefício , Desenho de Equipamento , Ergonomia , Humanos , Teste de Materiais , Cadeiras de Rodas/economia
5.
IEEE Trans Rehabil Eng ; 4(4): 320-7, 1996 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8973958

RESUMO

A method for designing seat support surfaces using interface pressure and soft tissue stiffness criteria was evaluated. An algorithm designed to drive a rigid support surface on a programmable seating system to a shape for which the externally applied pressure is inversely related to the measured stiffness of adjacent soft tissue was evaluated on 30 elderly subjects (age 65 years or older). The resulting support surface shapes were transferred to compliant foam cushions and evaluated using interface pressure measurements. Pressure and stiffness measurements on the seating system indicated the surface shape control algorithm met the desired programmed criteria by achieving an inverse relationship between pressure and stiffness, as it converged to an "optimal" support surface shape. Evaluation of interface pressures on the compliant foam cushions showed that the pressure distributions on the cushions contoured to the optimal surface shapes were more uniform and had lower values than distributions on flat foam cushions and foam cushions contoured to shapes measured using state-of-the-art load-deflection devices. The results suggest that support surfaces designed using tissue stiffness as a criteria can provide loading conditions intended to minimize relative deformation and, thus, stress in load-bearing soft tissue.


Assuntos
Úlcera por Pressão/prevenção & controle , Lesões dos Tecidos Moles/prevenção & controle , Cadeiras de Rodas , Idoso , Fenômenos Biomecânicos , Desenho de Equipamento , Humanos , Modelos Teóricos , Úlcera por Pressão/terapia
6.
IEEE Trans Rehabil Eng ; 4(2): 103-13, 1996 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8798077

RESUMO

A system for the design and analysis of seat support and buttock tissue interfaces has been developed. It has the ability to control the seating surface shape while measuring the pressure applied to the buttocks by the surface. Pressures are measured over an 11 x 12 rectangular array of support elements using silicon pressure sensors mounted in a swiveling head atop each support element. Control of surface shape is mediated by selective linear translation of the support elements along their respective vertical axes. Closed-loop control of the system allows for the dynamic formulation of a support surface on the basis of programmable criteria. The system is intended to function as a research tool to facilitate the study of the relationships between support surface shape and interface pressure, and support surface shape and soft tissue distortion. The purpose of this paper is to present the system instrumentation and the rationale behind its design and development. The paper also presents the results of several tests to evaluate the accuracy and performance of the system. This evaluation included a pilot study on 10 able-bodied subjects. The results of these system evaluations indicate that the system is capable of making repeatable and precise measurements of pressure and surface element position and can formulate support surface shapes that satisfy specified optimization criteria.


Assuntos
Nádegas , Desenho Assistido por Computador , Ergonomia , Decoração de Interiores e Mobiliário , Pressão , Dorso/fisiologia , Fenômenos Biomecânicos , Desenho de Equipamento , Humanos , Perna (Membro)/fisiologia , Projetos Piloto , Software , Suporte de Carga
7.
IEEE Trans Biomed Eng ; 40(1): 95-104, 1993 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8468081

RESUMO

The development, implementation and evaluation of an algorithm designed to find optimal seat support surfaces is presented. The algorithm has been developed and implemented on an active contour measurement device. The device consists of an array of positioning elements equipped with force sensors for feedback. With a patient seated on the array, the algorithm is designed to find a seat contour that optimally satisfies given performance criteria. The performance criteria are based on measured stiffness of the soft tissues. A theoretical development of the algorithm is presented along with the modifications made to the algorithm during implementation. The results from several tests using man-made test bodies and a prototype contour gage are presented to verify the algorithm's performance.


Assuntos
Nádegas/anatomia & histologia , Desenho Assistido por Computador/normas , Desenho de Equipamento/normas , Retroalimentação , Pressão , Cadeiras de Rodas/normas , Algoritmos , Antropometria , Elasticidade , Ergonomia , Estudos de Avaliação como Assunto , Humanos , Úlcera por Pressão/prevenção & controle
8.
Arch Phys Med Rehabil ; 73(3): 263-9, 1992 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-1543431

RESUMO

This study investigated the biomechanics of lever and hand-rim propulsion and the effects of seat position on propulsion mechanics. Nine able-bodied and six paraplegic spinal cord injured persons participated. Subjects performed hand-rim and lever propulsion on a wheelchair test simulator at a speed and load of 3km/hr and 7.5 watts/side, respectively. A 2 x 3 matrix of randomized seat positions was used. Three-dimensional motion measures of the trunk, shoulder, elbow, and wrist were collected over four-second sample periods for each seat position. Hub torque and stroke arc measurements were determined. Upper extremity motions were significantly different (p less than .05) for the two methods of propulsion. Hand-rim propulsion required less elbow motion, greater shoulder extension, less shoulder rotation and less arm abduction than lever propulsion. Both methods of propulsion required a substantial amount of internal rotation at the shoulder. Seat position changes had a greater effect on joint motion ranges when hand-rim propulsion was performed. No significant differences (p greater than .05) were found for trunk motion for the treatments. The findings provide additional information for development of a model for the optimization of wheelchair propulsion.


Assuntos
Paraplegia , Cadeiras de Rodas , Adulto , Antropometria , Fenômenos Biomecânicos , Desenho de Equipamento , Humanos , Cinética , Masculino , Paraplegia/fisiopatologia , Postura
9.
J Rehabil Res Dev ; 29(4): 32-40, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1432725

RESUMO

The design, application and evaluation of a specialized, personal computer-based manufacturing system for contouring foam cushions is presented. The topics discussed include both the hardware configuration and the software design. The target applications of this device are local or centralized fabrication of custom-contoured seat cushions. Although the technologies used for the development and implementation of this system are not new, using a personal-computer-based (PC) controller in place of a stand-alone numerically controlled (NC) motion controller significantly reduced the cost associated with this component. Further reductions in cost resulted from an optimization of the mechanical configuration for the dedicated task of carving foam cushions.


Assuntos
Desenho Assistido por Computador , Reabilitação/instrumentação , Estudos de Avaliação como Assunto , Utensílios Domésticos , Matemática , Design de Software
10.
Prosthet Orthot Int ; 15(1): 24-37, 1991 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1857638

RESUMO

Wheelchair biomechanics involves the study of how a wheelchair user imparts power to the wheels to achieve mobility. Because a wheelchair can coast, power input need not be continuous, but each power strike can be followed by a period of recovery, with the stroking frequency depending on user preferences and the coasting characteristics of the wheelchair. The latter is described in terms of rolling resistance, wind resistance and the slope of the surface. From these three factors the power required to propel the wheelchair is determined, and must be matched by the power output of the user. The efficiency of propulsion is the ratio of this power output to the metabolic cost and is typically in the order of 5% in normal use. The features required in a wheelchair depend upon user characteristics and intended activities. The ideal wheelchair for an individual will have the features that closely match these characteristics and activities. Thus prescription is not just choosing a wheelchair, but choosing the components of the wheelchair that best serve the intended purpose. In this paper, each component is examined for available options and how these options effect the performance of the wheelchair for the individual. The components include wheels, tyres, castors, frames, bearings, materials, construction details, seats, backrests, armrests, foot and legrests, headrests, wheel locks, running brakes, handrims, levers, accessories, adjustments and detachable parts. Each component is considered in relation to performance characteristics including rolling resistance, versatility, weight, comfort, stability, maneouvrability, transfer, stowage, durability and maintenance. Where they exist, wheelchair standards are referred to as a source of information regarding these characteristics.


Assuntos
Cadeiras de Rodas , Fenômenos Biomecânicos , Eficiência , Desenho de Equipamento , Feminino , Humanos , Masculino , Esforço Físico/fisiologia
11.
Med Des Mater ; 1(1): 32-41, 1991 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10147990

RESUMO

This article describes the development of a computer-controlled system for measuring anatomical contours and forces at the interface with seat surfaces. The system was designed to eliminate the cause of pressure sores, which are a major problem for wheelchair-bound individuals. A parallel and compatible system also has been developed for the rapid, precise, and cost-effective fabrication of custom-contoured seat cushions and other body supports from a range of open- and closed-cell foam materials.


Assuntos
Úlcera por Pressão/prevenção & controle , Cadeiras de Rodas , Algoritmos , Nádegas , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Ergonomia , Humanos
12.
J Rehabil Res Dev ; 27(2): 127-34, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2366196

RESUMO

This project focused on identifying the influence of subject characteristics and foam properties on seat contours in order to explain the load transfer between the buttocks and cushion. Seat contours were recorded for 17 people (11 spinal cord injured and six able-bodied individuals). Contour characteristics were represented by maximum contour depth, surface area, and displaced volume. Subject characteristics were represented as intertrochanteric distance, body weight, and lower extremity muscle tone. Two foams with different degrees of stiffness (45- and 55-pound indentation load deflection [ILD]) were studied. Multiple regression equations were calculated for each of the three contour characteristics by entering in all three subject attributes. While the equations differ, all six exhibited a significant Multiple R (range: 0.79 to 0.92). Each subject characteristic was a significant predictor of at least one contour trait (p less than 0.05). The major difference between the two cushions was the predictive ability of muscle tone. For the stiffer HR55 foam, muscle tone was the strongest predictor of all contour characteristics. Therefore, some conclusions can be drawn concerning the relationship between foam stiffness, tone, and resulting seat contours. These relationships help define the differences in load transfer as subject and cushion characteristics vary and are important in the design of contoured foam for use as wheelchair cushions.


Assuntos
Teste de Materiais/métodos , Úlcera por Pressão/prevenção & controle , Cadeiras de Rodas , Desenho de Equipamento , Humanos , Pressão
13.
J Rehabil Res Dev ; 27(2): 135-40, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2366197

RESUMO

Previous research indicated that matching a cushion to the shape of the buttocks results in less tissue distortion and lower interface pressures. A system was developed to measure body contours and fabricate a cushion to match the measured contour. This project fabricated contoured foam cushions for 11 persons with spinal cord lesions (C5-L3). Mean pressures were compared on two flat and two contoured foams with different degrees of stiffness. Deflection characteristics on flat foam were compared to deflection on contoured foam in order to analyze loading differences. Material studies were determined by examining the load-deflection curves for flat foams of 1-, 2-, and 3-inch thicknesses. It was found that sitting on contoured foam resulted in a lower pressure distribution than sitting on flat foam (p less than 0.05), and sitting on a soft foam (ILD = 45) resulted in a lower pressure distribution than sitting on a stiffer foam (ILD = 55) (p less than 0.05). Results of the deflection measurements and compression tests were used to explain the loading differences at the seat interface of flat and contoured cushions. Loaded contoured foam demonstrated increased enveloping of the buttocks, decreased foam compression, and a more uniform pressure distribution. These attributes are typical of a safer sitting surface and may indicate less tissue distortion.


Assuntos
Úlcera por Pressão/prevenção & controle , Cadeiras de Rodas , Fenômenos Biomecânicos , Nádegas , Desenho de Equipamento , Humanos , Teste de Materiais , Pressão/efeitos adversos , Úlcera por Pressão/etiologia , Traumatismos da Medula Espinal/complicações
14.
IEEE Eng Med Biol Mag ; 7(3): 21-4, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-18244070
15.
J Rehabil Res Dev ; 23(4): 19-26, 1986 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-3820118

RESUMO

Clearly, all considerations for wheelchair performance and their applicability to optimization of mobility are related to user position relative to the main wheel axis. It is also obvious that wheelchair performance is enhanced by a center of gravity position rearward of that which is characteristic of the generic wheelchair. The only obvious features of the generic wheelchair are excessive static stability and limitation of body motion. Perhaps at this stage the reader may be ready to accept some of the arguments presented above, but have reservations about prescribing a less stable wheelchair for the more severely disabled (e.g., quadraplegics). Consider that the reduction of rolling resistance, decrease in downhill turning tendancy, and required turning force would likely be even more important to the user with marginal physical capacity. This would appear as an attractive trade for reduction in static stability. The number of factors unfavorably affected by increased static stability would suggest the use of an anti-tipping device rather than designed static stability if this is thought to be an important consideration.


Assuntos
Cadeiras de Rodas/normas , Gravitação , Humanos , Paraplegia/reabilitação , Esportes
16.
J Rehabil Res Dev ; 23(2): 52-4, 1986 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3723425

RESUMO

The various stages of development of a lever drive system are described. The use of both roller and friction clutches are discussed and the means for controlling forward, reverse, and braking are included. The current system allows good maneuverability without requiring hand skills and may be effective for quadriplegics.


Assuntos
Cadeiras de Rodas , Humanos , Quadriplegia/reabilitação , Cadeiras de Rodas/normas
17.
J Rehabil Res Dev ; 23(2): 55-8, 1986 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3723426

RESUMO

Compensation for the downhill turning moment of a wheelchair on a 2-degree side slope results in retarding force approximately equal to the rolling drag of a wheelchair on a level surface. The total drag force on the wheelchair while transversing a sloping surface is, therefore, roughly double the rolling drag. In contrast, the net energy cost of propulsion on this side slope is only 30 percent greater than for a level surface. Side slope propulsion is managed by "dragging" the uphill rim while pushing the downhill rim. Although this results in increased mechanical efficiency through greater use of a smaller muscle mass, it is more difficult and tiring for the wheelchair user.


Assuntos
Cadeiras de Rodas , Humanos , Cadeiras de Rodas/normas
18.
Dev Med Child Neurol ; 25(2): 175-83, 1983 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-6852381

RESUMO

This study was designed to determine whether tonic myoelectric activity of low-back extensors of spastic cerebral-palsied children changed in response to changes in seating position, and if so, which position was coincident with the least extensor activity. Using two pairs of surface electrodes, the electrical activity of the lumbar erector spinae muscles was monitored in seven combinations of backrest inclinations (75 degrees, 90 degrees, 105 degrees and 120 degrees) and seat surface elevations (0 degrees and 15 degrees). Off-line analysis of action potential counts per second of recorded electromyographic signals showed that electrical activity was least when the seat surface elevation was 0 degrees and the backrest inclination 75 degrees. The results showed that differences existed in the activity of the low-back extensors in the seating positions that were assessed.


Assuntos
Paralisia Cerebral/fisiopatologia , Postura , Potenciais de Ação , Análise de Variância , Paralisia Cerebral/reabilitação , Criança , Pré-Escolar , Eletromiografia , Feminino , Humanos , Masculino , Espasticidade Muscular
19.
Phys Sportsmed ; 7(4): 87-92, 1979 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27421496

RESUMO

In 50 years of competitive tennis these super seniors have stayed in good condition and overcome problems ranging from tennis shoulder to heart disease.

20.
Phys Sportsmed ; 6(11): 111-119, 1978 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29256707

RESUMO

Because most Olympic weightlifting injuries are caused by inflexibility and improper technique, the well-trained lifter concentrates on improving these abilities.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA