Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
1.
Am J Audiol ; : 1-7, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38995872

RESUMO

PURPOSE: Clinical audiologists typically assume that headphones and insert phones will produce comparable results when they are used to conduct speech-in-noise or other audiological tests; however, this may not always be the case. Here, we show that there are significant differences in the scores that previous studies have reported for headphone and insert-phone transducers on the Words-in-Noise (WIN) Test, and discuss the possibility that the variations in high-frequency output that are allowable under the speech source specifications of American National Standards Institute S3.6 might be contributing to transducer-dependent differences in performance for the WIN and other tests that are presented through the auxiliary input channels of clinical audiometers. METHOD: A literature review was conducted to identify articles that reported WIN Test results for both listeners with normal hearing and with hearing impairment and specified the type of transducer (insert or TDH-50) used for the data collection. RESULTS: Among the 19 included studies, participants with normal hearing using inserts exhibited systematically worse WIN Test scores compared to those using TDH-50 headphones, while participants with hearing loss showed comparable average scores across transducer types. CONCLUSIONS: The results highlight the importance of considering transducer type when interpreting WIN Test outcomes, particularly when comparing to normative scores obtained from individuals with normal hearing. Although further research is needed to elucidate the underlying mechanisms driving differences in test performance across transducer types, these findings underscore the need for standardized test administration protocols and careful documentation of transducer type when administering speech-in-noise tests for clinical or research applications.

2.
J Speech Lang Hear Res ; 67(7): 2454-2472, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38950169

RESUMO

PURPOSE: A corpus of English matrix sentences produced by 60 native and nonnative speakers of English was developed as part of a multinational coalition task group. This corpus was tested on a large cohort of U.S. Service members in order to examine the effects of talker nativeness, listener nativeness, masker type, and hearing sensitivity on speech recognition performance in this population. METHOD: A total of 1,939 U.S. Service members (ages 18-68 years) completed this closed-set listening task, including 430 women and 110 nonnative English speakers. Stimuli were produced by native and nonnative speakers of English and were presented in speech-shaped noise and multitalker babble. Keyword recognition accuracy and response times were analyzed. RESULTS: General(ized) linear mixed-effects regression models found that, on the whole, speech recognition performance was lower for listeners who identified as nonnative speakers of English and when listening to speech produced by nonnative speakers of English. Talker and listener effects were more pronounced when listening in a babble masker than in a speech-shaped noise masker. Response times varied as a function of recognition score, with longest response times found for intermediate levels of performance. CONCLUSIONS: This study found additive effects of talker and listener nonnativeness when listening to speech in background noise. These effects were present in both accuracy and response time measures. No multiplicative effects of talker and listener language background were found. There was little evidence of a negative interaction between talker nonnativeness and hearing impairment, suggesting that these factors may have redundant effects on speech recognition. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.26060191.


Assuntos
Ruído , Mascaramento Perceptivo , Inteligibilidade da Fala , Percepção da Fala , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Adulto Jovem , Idoso , Adolescente , Estados Unidos , Mascaramento Perceptivo/fisiologia , Estudos de Coortes , Idioma , Militares
3.
J Acoust Soc Am ; 156(1): 475-488, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39013035

RESUMO

Extended-wear hearing aids (EWHAs) are small broadband analog amplification devices placed deeply enough in the ear canal to preserve most of the cues in the head-related transfer function. However, little is known about how EWHAs affect localization accuracy for normal hearing threshold (NHT) listeners. In this study, eight NHT participants were fitted with EWHAs and localized broadband sounds of different durations (250 ms and 4 s) and stimulus intensities (40, 50, 60, 70, and 80 dBA) in a spherical speaker array. When the EWHAs were in the active mode, localization accuracy was only slightly degraded relative to open-ear performance. However, when the EWHAs were turned off, localization performance was substantially degraded even at the highest stimulus intensities. An electro-acoustical evaluation of the EWHAs showed minimal effects of dynamic range compression on the signals and good preservation of the signal pattern for vertical polar sound localization. Between-study comparisons suggest that EWHA active mode localization accuracy is favorable compared to conventional active earplugs, and EWHA passive mode localization accuracy is comparable to conventional passive earplugs. These results suggest that the deep-insertion analog design of the EWHA is generally better at preserving localization accuracy of NHT listeners than conventional earplug devices.


Assuntos
Limiar Auditivo , Auxiliares de Audição , Localização de Som , Humanos , Adulto , Masculino , Feminino , Adulto Jovem , Estimulação Acústica/métodos , Sinais (Psicologia) , Desenho de Equipamento
4.
Trends Hear ; 28: 23312165241242235, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38738302

RESUMO

The objective of this project was to establish cutoff scores on the tinnitus subscale of the Tinnitus and Hearing Survey (THS) using a large sample of United States service members (SM) with the end goal of guiding clinical referrals for tinnitus evaluation. A total of 4,589 SM undergoing annual audiometric surveillance were prospectively recruited to complete the THS tinnitus subscale (THS-T). A subset of 1,304 participants also completed the Tinnitus Functional Index (TFI). The original 5-point response scale of the THS (THS-T16) was modified to an 11-point scale (THS-T40) for some participants, to align with the response scale of the TFI. Age, sex, hearing loss, and self-reported tinnitus bother were also recorded. The THS-T was relatively insensitive to hearing, but self-reported bothersome tinnitus was significantly associated with the THS-T40 score. Receiver operating characteristic analysis was used to determine cutoff scores on the THS-T that aligned with recommended cutoff values for clinical intervention on the TFI. A cutoff of 9 on the THS-T40 aligns with a TFI cutoff of 25, indicating a patient may need intervention for tinnitus. A cutoff of 15 aligns with a TFI cutoff of 50, indicating that more aggressive intervention for tinnitus is warranted. The THS-T is a viable tool to identify patients with tinnitus complaints warranting clinical evaluation for use by hearing conservation programs and primary care clinics. The THS-T40 cutoff scores of 9 and 15 provide clinical reference points to guide referrals to audiology.


Assuntos
Zumbido , Humanos , Zumbido/diagnóstico , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Estudos Prospectivos , Estados Unidos , Audição , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Curva ROC , Inquéritos e Questionários , Autorrelato , Audiometria/métodos
5.
J Speech Lang Hear Res ; 67(5): 1602-1623, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38569080

RESUMO

PURPOSE: The purpose of this study was to explore potential differences in suprathreshold auditory function among native and nonnative speakers of English as a function of age. METHOD: Retrospective analyses were performed on three large data sets containing suprathreshold auditory tests completed by 5,572 participants who were self-identified native and nonnative speakers of English between the ages of 18-65 years, including a binaural tone detection test, a digit identification test, and a sentence recognition test. RESULTS: The analyses show a significant interaction between increasing age and participant group on tests involving speech-based stimuli (digit strings, sentences) but not on the binaural tone detection test. For both speech tests, differences in speech recognition emerged between groups during early adulthood, and increasing age had a more negative impact on word recognition for nonnative compared to native participants. Age-related declines in performance were 2.9 times faster for digit strings and 3.3 times faster for sentences for nonnative participants compared to native participants. CONCLUSIONS: This set of analyses extends the existing literature by examining interactions between aging and self-identified native English speaker status in several auditory domains in a cohort of adults spanning young adulthood through middle age. The finding that older nonnative English speakers in this age cohort may have greater-than-expected deficits on speech-in-noise perception may have clinical implications on how these individuals should be diagnosed and treated for hearing difficulties.


Assuntos
Ruído , Percepção da Fala , Humanos , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Percepção da Fala/fisiologia , Idoso , Adolescente , Masculino , Feminino , Estudos Retrospectivos , Envelhecimento/psicologia , Envelhecimento/fisiologia , Fatores Etários , Idioma , Limiar Auditivo/fisiologia
6.
Healthcare (Basel) ; 12(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38470689

RESUMO

Low- (or mild-) gain hearing aids (LGHAs) are increasingly considered for individuals with normal peripheral hearing but significant self-reported hearing difficulties (SHDs). This study assesses the benefits of LGHAs as a management option for individuals with normal hearing thresholds (NHTs) and SHDs, comparing LGHA use and benefit to individuals with non-significant hearing difficulties (NHDs) and those with peripheral hearing loss. Questionnaires addressing hearing aid usage, benefit, hearing difficulties, and tinnitus were administered to 186 individuals who self-identified as hearing aid users in a sample of 6652 service members who were receiving their annual hearing tests. Participants were divided into SHD and NHD groups based on the normative cutoff of the Tinnitus and Hearing Survey-Hearing Subscale (THS-H), and into hearing impairment (HI) and NHT based on their audiometric air-conduction thresholds. Individuals with SHDs and NHTs reported higher LGHA usage and benefit than individuals with NHDs and NHTs. Comparable use and benefit were noted between groups with SHDs regardless of peripheral hearing loss status. The findings support LGHAs as a suitable management option for individuals with NHTs and SHDs, as indicated by hearing aid use and benefit. Quantifying the level of perceived auditory processing deficits (i.e., SHDs), notably with the THS-H, enhances sensitivity in identifying those who may benefit the most from this treatment option.

7.
Ear Hear ; 45(1): 130-141, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37599415

RESUMO

OBJECTIVES: Estimated prevalence of functional hearing and communication deficits (FHCDs), characterized by abnormally low speech recognition and binaural tone detection in noise or an abnormally high degree of self-perceived hearing difficulties, dramatically increases in active-duty service members (SMs) who have hearing thresholds slightly above the normal range and self-report to have been close to an explosive blast. Knowing the exact nature of the underlying auditory-processing deficits that contribute to FHCD would not only provide a better characterization of the effects of blast exposure on the human auditory system, but also allow clinicians to prescribe appropriate therapies to treat or manage patient complaints. DESIGN: Two groups of SMs were initially recruited: (1) a control group (N = 78) with auditory thresholds ≤20 dB HL between 250 and 8000 Hz, no history of blast exposure, and who passed a short FHCD screener, and (2) a group of blast-exposed SMs (N = 26) with normal to near-normal auditory thresholds between 250 and 4000 Hz, and who failed the FHCD screener (cutoffs based on the study by Grant et al.). The two groups were then compared on a variety of audiometric, behavioral, cognitive, and electrophysiological measures. These tests were selected to characterize various aspects of auditory system processing from the cochlear to the cortex. A third, smaller group of blast-exposed SMs who performed within normal limits on the FHCD screener were also recruited (N = 11). This third subject group was unplanned at the onset of the study and was added to evaluate the effects of blast exposure on hearing and communication regardless of performance on the FHCD screener. RESULTS: SMs in the blast-exposed group with FHCD performed significantly worse than control participants on several metrics that measured peripheral and mostly subcortical auditory processing. Cognitive processing was mostly unaffected by blast exposure with the exception of cognitive tests of language-processing speed and working memory. Blast-exposed SMs without FHCD performed similarly to the control group on tests of peripheral and brainstem processing, but performed similarly to blast-exposed SMs with FHCD on measures of cognitive processing. Measures derived from EEG recordings of the frequency-following response revealed that blast-exposed SMs who exhibited FHCD demonstrated increased spontaneous neural activity, reduced amplitude of the envelope-following response, poor internal signal to noise ratio, reduced response stability, and an absent or delayed onset response, compared with the other two participant groups. CONCLUSIONS: Degradation in the neural encoding of acoustic stimuli is likely a major contributing factor leading to FHCD in blast-exposed SMs with normal to near-normal audiometric thresholds. Blast-exposed SMs, regardless of their performance on the FHCD screener, exhibited a deficit in language-processing speed and working memory, which could lead to difficulties in decoding rapid speech and in understanding speech in challenging speech communication settings. Further tests are needed to align these findings with clinical treatment protocols being used for patients with suspected auditory-processing disorders.


Assuntos
Perda Auditiva , Percepção da Fala , Humanos , Audição , Percepção Auditiva/fisiologia , Testes Auditivos , Limiar Auditivo
8.
Mil Med ; 188(Suppl 6): 176-184, 2023 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-37948248

RESUMO

INTRODUCTION: Although existing auditory injury prevention standards benefit warfighters, the Department of Defense could do more to understand and address auditory injuries (e.g., hearing loss, tinnitus, and central processing deficits) among service members. The Blast Injury Prevention Standards Recommendation (BIPSR) Process is designed to address the needs of all the Military Services for biomedically valid Military Health System (MHS) Blast Injury Prevention Standards. MATERIALS AND METHODS: Through the BIPSR Process, stakeholders provided their intended uses and requested functionalities for an MHS Blast Injury Prevention Standard. The BIPSR Process established a broad-based, non-advocacy panel of auditory injury Subject Matter Expert (SME) Panel with members drawn from industry, academia, and government. The SME Panel selected evaluation factors, weighted priorities, and then evaluated the resulting candidate MHS Auditory Blast Injury Prevention Standards against the evaluation criteria. The SME Panel members provided rationales for their decisions, documented discussions, and used iterative rounds of feedback to promote consensus building among members. The BIPSR Process used multi-attribute utility theory to combine members' evaluations and compare the candidate standards. RESULTS: The SME Panel identified and collated information about existing auditory injury datasets to identify gaps and promote data sharing and comprehensive evaluations of standards for preventing auditory blast injury. The panel evaluated the candidate standards and developed recommendations for an MHS Blast Injury Prevention Standard. CONCLUSIONS: The BIPSR Process illuminated important characteristics, capabilities, and limitations of candidate standards and existing datasets (e.g., limited human exposure data to evaluate the validity of injury prediction) for auditory blast injury prevention. The evaluation resulted in the recommendation to use the 8-hour Equivalent Level (LAeq8hr) as the interim MHS Auditory Blast Injury Prevention Standard while the community performs additional research to fill critical knowledge gaps.


Assuntos
Traumatismos por Explosões , Perda Auditiva , Serviços de Saúde Militar , Militares , Zumbido , Humanos , Traumatismos por Explosões/prevenção & controle , Explosões , Zumbido/prevenção & controle
9.
Mil Med ; 188(Suppl 6): 529-535, 2023 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-37948280

RESUMO

INTRODUCTION: U.S. Army regulations require all soldiers to undergo annual audiometric testing to maintain hearing readiness. The standard method of monitoring hearing in the DoD is via multi-person testing in sound-treated booths using the Defense Occupational and Environmental Health Readiness System-Hearing Conservation. COVID-19 significantly hindered the standard method, resulting in alarming declines in hearing readiness. In response, the Army Hearing Program initiated a pilot program to use boothless audiometers to supplement standard methods to increase hearing readiness. MATERIALS AND METHODS: Funding from the Coronavirus Aid, Relief, and Economic Security Act was used to purchase 169 boothless audiometers and increase staffing at dozens of Army Hearing Program clinics. Standard operating procedures were established for audiometric testing outside the booth using a process matching standard test parameters (i.e., test frequencies, tone characteristics, and interstimulus intervals). Additional capabilities developed to leverage this new technology during the annual hearing exam include the administration of automated contralateral masking, enhanced tinnitus screening, and hearing health education and training. RESULTS: Monitoring audiometry using boothless audiometers has been conducted for nearly 12,000 service members worldwide. Thresholds obtained via boothless audiometers are comparable to follow-up thresholds obtained from the standard test methods in the booth (mean difference 95% CI, -1.2, 0.9), and hearing readiness has returned to pre-pandemic levels at installations where this novel technology is being used regularly. CONCLUSIONS: Significant reductions in patient encounters as a direct result of the COVID-19 pandemic have led to innovative solutions leveraging boothless audiometers. While this has aided the primary mission to maintain a medically ready force, innovations from this endeavor highlight several additional improvements relative to current standards of care that should be considered for permanent inclusion in DoD Hearing Conservation Programs.


Assuntos
Militares , Pandemias , Humanos , Audiometria de Tons Puros/métodos , Audição , Audiometria , Limiar Auditivo
10.
Mil Med ; 188(Suppl 6): 666-673, 2023 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-37948283

RESUMO

INTRODUCTION: This prospective, multi-site, observational study describes ongoing efforts in support of the Fiscal Year 2018 National Defense Authorization Act (NDAA) Section 734 Blast Overpressure Study (BOS) to identify the acute effects impulse and blast exposure have on hearing abilities of the Warfighter in various military training environments. MATERIALS AND METHODS: Hearing thresholds, a binaural tone detection task, and auditory symptoms were collected before and immediately following weapons exposure across nine military training environments from January 2020 to October 2022. An additional 25 non-exposed control participants also completed the behavioral test battery. A boothless audiometer was used to measure hearing ability in the field. Sound level meters were attached on-body to record the exposure environment throughout training. RESULTS: Mean threshold change for the blast-exposed group was worse than the control group. Of the 188 blast-exposed participants, 23 experienced a temporary threshold shift (TTS) acutely after exposure. A decrease in binaural tone detection performance and increased symptom severity was found when comparing blast-exposed participants with a TTS versus those without a significant change in hearing. A complex but consistent relationship between measured exposure level (LAeq8hr) and the magnitude of the resulting TTS is suggested in the available data. CONCLUSIONS: Recent discussions on Section 734 studies examining the effects of repetitive blast exposure have indicated that hearing-related issues were a critical problem that needed additional research. Study outcomes provide highly repeatable results across various weapons systems with hazardous blast exposure. This standardized set of hearing assessment tools for evaluating acute effects of noise under field conditions has been critically important in improving our understanding of TTS in prospective human subject research.


Assuntos
Traumatismos por Explosões , Perda Auditiva Provocada por Ruído , Humanos , Limiar Auditivo , Traumatismos por Explosões/complicações , Traumatismos por Explosões/diagnóstico , Audição , Perda Auditiva Provocada por Ruído/etiologia , Perda Auditiva Provocada por Ruído/diagnóstico , Ruído , Estudos Prospectivos
11.
Trends Hear ; 27: 23312165231198374, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37822285

RESUMO

Hearing difficulties are frequently reported by patients in audiology clinics, including patients with normal audiometric thresholds. However, because all individuals experience some difficulty understanding speech in noisy environments, it can be difficult to assess hearing complaints objectively across patients. Normative values help address this issue by providing an objective cutoff score for determining what is or is not clinically significant. The goal of this study was to establish normative values for the four-item hearing subscale of the Tinnitus and Hearing Survey (THS-H). Respondents completing the THS-H rate the level of difficulty understanding speech in the situations most commonly reported as being difficult: in the presence of noise, on TV or in movies, soft voices and group conversations. In this study, 22,583 US Service Members (SMs) completed the THS-H using an 11-point scale ranging from 0 (not a problem) to 10 (a very big problem). Responses to the four items were summed to produce values between 0 and 40. The distribution of the final scores was analyzed based on severity of hearing loss, age, and sex. Only 5% of SMs with clinically normal hearing scored above 27, so this score was selected as a cutoff for "clinically significant hearing problems." Due to its ease of administration and interpretation, the THS-H could be a useful tool for identifying patients with subjective hearing difficulty warranting audiological evaluation and management.


Assuntos
Surdez , Perda Auditiva , Percepção da Fala , Zumbido , Humanos , Zumbido/diagnóstico , Zumbido/etiologia , Audição/fisiologia , Testes Auditivos , Perda Auditiva/diagnóstico , Perda Auditiva/complicações , Inquéritos e Questionários
12.
J Speech Lang Hear Res ; 66(9): 3364-3381, 2023 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-37532245

RESUMO

INTRODUCTION: Difficult communication environments are common in military settings, and effective voice use can be critical to mission success. This study aimed to estimate the prevalence of self-reported voice disorders among U.S. military service members and to identify factors that contribute to their voice concerns. METHOD: A nonclinical sample of 4,123 active-duty service members was recruited across Department of Defense hearing conservation clinics. During their required annual hearing evaluation, volunteers provided responses to voice-related questions including a slightly adapted version of the Voice Handicap Index-10 (VHI-10) as part of a larger survey about communication issues. Changepoint detection was applied to age and years of service to explore cohort effects in the reporting of voice concerns. Logistic regression analyses examined multiple available factors related to communication to identify factors associated with abnormal results on the VHI-10. RESULTS: Among the respondents, 41% reported experiencing vocal hoarseness or fatigue at least several times per year, and 8.2% (n = 336) scored above the recommended abnormal cut-point value of 11 on the VHI-10. Factors independently associated with the greatest risk for self-reported voice concerns were sex (female), cadmium exposure, vocal demands (the need for a strong, clear voice), and auditory health measures (frequency of experiencing temporary threshold shifts; self-reported hearing difficulties). CONCLUSIONS: Based on self-reported voice concerns and false negative rates reported in the literature, the prevalence of dysphonia in a large sample of active-duty service members is estimated to be 11.7%, which is higher than that in the general population. Certain predictors for voice concerns were expected based on previous literature, like female sex and voice use, but frequency of temporary threshold shifts and exposure to cadmium were surprising. The strong link between voice and auditory problems has particular implications regarding the need for effective communication in high-noise military and other occupational environments.


Assuntos
Disfonia , Militares , Distúrbios da Voz , Humanos , Feminino , Autorrelato , Prevalência , Cádmio , Disfonia/diagnóstico , Distúrbios da Voz/epidemiologia , Distúrbios da Voz/diagnóstico , Inquéritos e Questionários , Avaliação da Deficiência
13.
Trends Hear ; 27: 23312165231186040, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37415497

RESUMO

Information regarding sound-source spatial location provides several speech-perception benefits, including auditory spatial cues for perceptual talker separation and localization cues to face the talker to obtain visual speech information. These benefits have typically been examined separately. A real-time processing algorithm for sound-localization degradation (LocDeg) was used to investigate how spatial-hearing benefits interact in a multitalker environment. Normal-hearing adults performed auditory-only and auditory-visual sentence recognition with target speech and maskers presented from loudspeakers at -90°, -36°, 36°, or 90° azimuths. For auditory-visual conditions, one target and three masking talker videos (always spatially separated) were rendered virtually in rectangular windows at these locations on a head-mounted display. Auditory-only conditions presented blank windows at these locations. Auditory target speech (always spatially aligned with the target video) was presented in co-located speech-shaped noise (experiment 1) or with three co-located or spatially separated auditory interfering talkers corresponding to the masker videos (experiment 2). In the co-located conditions, the LocDeg algorithm did not affect auditory-only performance but reduced target orientation accuracy, reducing auditory-visual benefit. In the multitalker environment, two spatial-hearing benefits were observed: perceptually separating competing speech based on auditory spatial differences and orienting to the target talker to obtain visual speech cues. These two benefits were additive, and both were diminished by the LocDeg algorithm. Although visual cues always improved performance when the target was accurately localized, there was no strong evidence that they provided additional assistance in perceptually separating co-located competing speech. These results highlight the importance of sound localization in everyday communication.


Assuntos
Localização de Som , Percepção da Fala , Adulto , Humanos , Fala , Mascaramento Perceptivo , Audição , Transtornos da Audição
14.
J Acoust Soc Am ; 153(6): 3362, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37338291

RESUMO

Non-native, accented speech spoken by unfamiliar talkers can be challenging to recognize, but rapid improvements in perception are often observed after a short period of exposure. However, it is not clear whether these improvements are retained over multiple sessions. Stimulus variability facilitates learning for non-native speech, so it is possible it may also induce increased retention of learning for speech produced with an unfamiliar accent. In this paper, we conduct a retrospective analysis of a dataset well suited to examine learning of non-native English speech on both a within-session and across-session basis. During data collection, participants completed a protocol involving recognition of matrix sentences recorded by native and non-native talkers with different first languages. Listeners completed the protocol in a self-paced approach, including 15 blocks of 50 trials over 4-7 days, separated by an average of 1-2 days. Learning was strongest within the first day, and improvements were retained at subsequent test sessions. The pace of learning was faster for stimuli produced by native speakers of English as compared to non-native English speakers.


Assuntos
Percepção da Fala , Humanos , Estudos Retrospectivos , Aprendizagem , Idioma , Fala
15.
J Speech Lang Hear Res ; 66(4): 1378-1393, 2023 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-36898137

RESUMO

PURPOSE: The Masking Level Difference (MLD) has been used for decades to evaluate the binaural listening advantage. Although originally measured using Bekesy audiometry, the most common clinical use of the MLD is the CD-based Wilson 500-Hz technique with interleaved N0S0 and N0Sπ components. Here, we propose an alternative technique based on manual audiometry as a faster way of measuring the MLD. The article describes the advantages to this administration technique and evaluates if it is a viable alternative for the Wilson technique. METHOD: Data were retrospectively analyzed on 264 service members (SMs). All SMs completed both the Wilson and Manual MLDs. Descriptive and correlational statistics were applied to evaluate the comparisons between the two techniques and highlight the differences. Equivalence measures were also completed to compare the tests using a standardized cutoff score. Analyses were also made to compare both techniques to subjective and objective measures of hearing performance. RESULTS: Moderate to high positive correlations were determined between Wilson and Manual measures of each threshold (N0Sπ and N0S0). Although the Manual and Wilson MLD techniques produced significantly different thresholds, simple linear transformations can be used to obtain approximately equivalent scores on the two tests, and agreement was high for using these transformed scores to identify individuals with substantial MLD deficits. Both techniques had moderate test-retest reliability. The Manual MLD and components had stronger correlations to the subjective and objective hearing measures than the Wilson. CONCLUSIONS: The Manual technique is a faster method for obtaining MLD scores that is just as reliable as the CD-based Wilson test. With the significant reduction in assessment time and comparable results, the Manual MLD is a viable alternative for direct use in the clinic.


Assuntos
Audiometria , Mascaramento Perceptivo , Humanos , Limiar Auditivo , Reprodutibilidade dos Testes , Estudos Retrospectivos , Audiometria de Tons Puros
16.
Am J Audiol ; 32(3S): 694-705, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36796026

RESUMO

PURPOSE: The objectives of this study were to (a) describe normative ranges-expressed as reference intervals (RIs)-for vestibular and balance function tests in a cohort of Service Members and Veterans (SMVs) and (b) to describe the interrater reliability of these tests. METHOD: As part of the Defense and Veterans Brain Injury Center (DVBIC)/Traumatic Brain Injury Center of Excellence 15-year Longitudinal Traumatic Brain Injury (TBI) Study, participants completed the following: vestibulo-ocular reflex suppression, visual-vestibular enhancement, subjective visual vertical, subjective visual horizontal, sinusoidal harmonic acceleration, the computerized rotational head impulse test (crHIT), and the sensory organization test. RIs were calculated using nonparametric methods and interrater reliability was assessed using intraclass correlation coefficients between three audiologists who independently reviewed and cleaned the data. RESULTS: Reference populations for each outcome measure comprised 40 to 72 individuals, 19 to 61 years of age, who served either as noninjured controls (NIC) or injured controls (IC) in the 15-year study; none had a history of TBI or blast exposure. A subset of 15 SMVs from the NIC, IC, and TBI groups were included in the interrater reliability calculations. RIs are reported for 27 outcome measures from the seven rotational vestibular and balance tests. Interrater reliability was considered excellent for all tests except the crHIT, which was found to have good interrater reliability. CONCLUSION: This study provides clinicians and scientists with important information regarding normative ranges and interrater reliability for rotational vestibular and balance tests in SMVs.


Assuntos
Lesões Encefálicas Traumáticas , Lesões Encefálicas , Veteranos , Humanos , Reprodutibilidade dos Testes , Reflexo Vestíbulo-Ocular , Lesões Encefálicas Traumáticas/diagnóstico
17.
Int J Audiol ; 62(2): 138-150, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35073491

RESUMO

OBJECTIVE: The purpose of this study was to evaluate auditory performance of military instructors as part of a training course involving noise and blast exposure. Boothless audiometry was used to estimate the test-retest reliability of the auditory measures under realistic field conditions and to determine risk of acute auditory injury during standard training practices. DESIGN AND STUDY SAMPLE: Thirteen U.S. Marine instructors participated in study activities. An audiologic testing suite embedded in a noise-attenuating headset was used to test various tone detection tasks on subjects after exposure. Acoustic exposures were captured with sound level meters. RESULTS: Boothless audiometry provide highly repeatable results for various tests of auditory performance in the field environment. In this test population, changes in auditory performance pre- and post-noise exposure were minimal for most measures. The notable exception was binaural (NoSπ) tone detection, which showed significant degradations both as a function of pre- and post-noise exposure on the same day and as a result of cumulative noise exposure over the period of the study. CONCLUSIONS: Study outcomes are consistent with prior laboratory and epidemiological work and suggest a link between the binaural processes required for NoSπ detection and the hearing-related issues reported by blast-exposed service members.


Assuntos
Percepção da Fala , Humanos , Percepção da Fala/fisiologia , Limiar Auditivo/fisiologia , Reprodutibilidade dos Testes , Audição , Exposição Ambiental , Audiometria de Tons Puros
18.
Ear Hear ; 44(1): 209-222, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36323655

RESUMO

OBJECTIVES: One important function of military audiology is to conduct evaluations of service members (SMs) with hearing loss to ensure they are fit for deployment in dangerous operational environments. The objective of this study was to establish evidence-based auditory fitness-for-duty criteria based on speech-in-noise performance on the 80- and 160-word clinical versions of the Modified Rhyme Test (MRT 80 and MRT 160 ). DESIGN: Approximately 2400 SMs with various levels of hearing loss were recruited to complete the MRT 80 in conjunction with their annual hearing conservation evaluations. These SMs were also asked to perform one or more operationally-relevant listening tasks based on audio recordings made in highly realistic military training environments. The scores on these tests were compared to determine how well a proposed cutoff criterion for the MRT 80 was able to identify individuals who are hard of hearing with an exceptionally high risk of abnormally poor performance on operationally-relevant hearing tasks. RESULTS: The results show that a cutoff criterion that combines the percent correct score on two lists of the MRT 80 (i.e. MRT 160 ) with information about the better-ear threshold at 2 kHz is generally able to separate listeners with hearing loss into those who are likely to perform relatively well on operational listening tests and those who are likely to perform poorly on these tasks. This is consistent with current military acquisition standards, which identify the MRT as the preferred test for evaluating speech intelligibility for radios, headsets, and other communication equipment. It is also consistent with prior studies conducted in high-fidelity military simulations which have shown a significant correlation between MRT performance and operational outcomes. CONCLUSIONS: The proposed selection criteria, along with the new hearing profile standards that were recently adopted by the US Army, appear to provide an effective evidence-based methodology for identifying those SMs with hearing loss who are most at risk for poor performance on hearing-critical military tasks.


Assuntos
Militares , Percepção da Fala , Humanos , Audição , Ruído , Percepção Auditiva , Inteligibilidade da Fala
19.
BMC Med Res Methodol ; 22(1): 317, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36513998

RESUMO

BACKGROUND: Subconcussive blast exposure during military training has been the subject of both anecdotal concerns and reports in the medical literature, but prior studies have often been small and have used inconsistent methods. METHODS: This paper presents the methodology employed in INVestigating traIning assoCiated blasT pAthology (INVICTA) to assess a wide range of aspects of brain function, including immediate and delayed recall, gait and balance, audiologic and oculomotor function, cerebral blood flow, brain electrical activity and neuroimaging and blood biomarkers. RESULTS: A number of the methods employed in INVICTA are relatively easy to reproducibly utilize, and can be completed efficiently, while other measures require greater technical expertise, take longer to complete, or may have logistical challenges. CONCLUSIONS: This presentation of methods used to assess the impact of blast exposure on the brain is intended to facilitate greater uniformity of data collection in this setting, which would enable comparison between different types of blast exposure and environmental circumstances, as well as to facilitate meta-analyses and syntheses across studies.


Assuntos
Traumatismos por Explosões , Concussão Encefálica , Militares , Humanos , Traumatismos por Explosões/patologia , Concussão Encefálica/patologia , Biomarcadores
20.
J Acoust Soc Am ; 152(3): 1283, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36182325

RESUMO

Current standards for the measurement of impulse noise (e.g., MIL-STD-1474E) recommend using a sampling rate of at least 200 kHz in order to accurately estimate the risk of hearing damage. The given motivation for this high sampling rate is to ensure a temporal resolution in the impulse waveform fine enough to accurately capture the peak pressure. However, the Nyquist-Shannon sampling theorem specifies that a sampled signal can accurately reconstruct both the amplitude and phase information of a signal given the sampling rate is at least twice the highest frequency present in the original signal. Thus, it is possible to reconstruct a band limited signal with the same temporal resolution as one captured at a higher sampling rate if the contributions of energy above the Nyquist rate can be ignored. In this study, resampling techniques are applied to a signal sampled at 48 kHz to extract A-weighted sound pressure energy estimates within 0.1 dB of those obtained at a higher sampling rate. Our results suggest sampling rates for impulsive noise should be based on the range of frequencies expected to make a contribution to injury risk rather than on concerns about temporal resolution.


Assuntos
Perda Auditiva Provocada por Ruído , Acústica , Audição , Perda Auditiva Provocada por Ruído/etiologia , Humanos , Ruído/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA