RESUMO
AIM: Automated insulin delivery (AID) systems have demonstrated improved glycaemic outcomes in people with type 1 diabetes (T1D), yet limited data exist on these systems in very young children and their impact on caregivers. We evaluated psychosocial outcomes following use of the tubeless Omnipod® 5 AID System in caregivers of very young children. MATERIALS AND METHODS: This 3-month single-arm, multicentre, pivotal clinical trial enrolled 80 children aged 2.0-5.9 years with T1D to use the Omnipod 5 AID System. Caregivers completed questionnaires assessing psychosocial outcomes-diabetes distress (Problem Areas in Diabetes), hypoglycaemia confidence (Hypoglycemia Confidence Scale), well-being (World Health Organization 5 Well-Being Index), sleep quality (Pittsburgh Sleep Quality Index), insulin delivery satisfaction (Insulin Delivery Satisfaction Survey) and system usability (System Usability Scale) at baseline with standard therapy and after 3 months of AID use. RESULTS: Following 3 months of Omnipod 5 use, caregivers experienced significant improvements across all measures, including diabetes-related psychosocial outcomes (Problem Areas in Diabetes; p < 0.0001, Hypoglycemia Confidence Scale; p < 0.01), well-being (World Health Organization 5 Well-Being Index; p < 0.0001) and perceived system usability (System Usability Scale; p < 0.0001). Significant improvements were seen in the Pittsburgh Sleep Quality Index total score and the overall sleep quality, sleep duration and efficiency subscales (all p < 0.05). Insulin Delivery Satisfaction Survey scores improved on all subscales (greater satisfaction, reduced burden and reduced inconvenience; all p < 0.0001). CONCLUSIONS: Caregivers face unique challenges when managing T1D in very young children. While glycaemic metrics have unquestioned importance, these results evaluating psychosocial outcomes reveal additional meaningful benefits and suggest that the Omnipod 5 AID System alleviates some of the burdens caregivers face with diabetes management.
RESUMO
OBJECTIVE: We aimed to assess the feasibility, clinical accuracy, and acceptance of a hospital-wide continuous glucose monitoring (CGM) policy with electronic health record (EHR)-integrated validation for insulin dosing. RESEARCH DESIGN AND METHODS: A hospital policy was developed and implemented at Stanford Health Care for using personal CGMs in lieu of fingerstick blood glucose (FSBG) monitoring. It included requirements specific to each CGM, accuracy monitoring protocols, and EHR integration. User experience surveys were conducted among a subset of patients and nurses. RESULTS: From November 2022 to August 2023, 135 patients used the CGM protocol in 185 inpatient encounters. This group included 27% with type 1 diabetes and 24% with automated insulin delivery systems. The most-used CGMs were Dexcom G6 (44%) and FreeStyle Libre 2 (43%). Of 1,506 CGM validation attempts, 87.8% met the 20% or 20 mg/dL (%20/20) criterion for CGM-based insulin dosing and 99.3% fell within Clarke zones A or B. User experience surveys were completed by 27 nurses and 46 patients. Most nurses found glucose management under the protocol effective (74%), easy to use (67%), and efficient (63%); 80% of nurses preferred inpatient CGM to FSBG. Most patients liked the CGM protocol (63%), reported positive CGM interactions with nursing staff (63%), and felt no significant interruptions to their diabetes management (63%). CONCLUSIONS: Implementation of a hospital-wide inpatient CGM policy supporting multiple CGM types with real-time accuracy monitoring and integration into the EHR is feasible. Initial feedback from nurses and patients was favorable, and further investigation toward broader use and sustainability is needed.
Assuntos
Automonitorização da Glicemia , Registros Eletrônicos de Saúde , Insulina , Humanos , Insulina/administração & dosagem , Insulina/uso terapêutico , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Automonitorização da Glicemia/métodos , Glicemia/análise , Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Idoso , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/sangue , HospitaisRESUMO
Objectives: To report the safety and side effects associated with taking verapamil for beta-cell preservation in children with newly-diagnosed T1D. Research Design and Methods: Eighty-eight participants aged 8.5 to 17.9 years weighing ≥ 30 kg were randomly assigned to verapamil (N = 47) or placebo (N = 41) within 31 days of T1D diagnosis and followed for 12 months from diagnosis, main CLVer study. Drug dosing was weight-based with incremental increases to full dosage. Side effect monitoring included serial measurements of pulse, blood pressure, liver enzymes, and electrocardiograms (ECGs). At study end, participants were enrolled in an observational extension study (CLVerEx), which is ongoing. No study drug is provided during the extension, but participants may use verapamil if prescribed by their diabetes care team. Results: Overall rates of adverse events were low and comparable between verapamil and placebo groups. There was no difference in the frequency of liver function abnormalities. Three CLVer participants reduced or discontinued medication due to asymptomatic ECG changes. One CLVerEx participant (18 years old), treated with placebo during CLVer, who had not had a monitoring ECG, experienced complete AV block with a severe hypotensive episode 6 weeks after reaching his maximum verapamil dose following an inadvertent double dose on the day of the event. Conclusions: The use of verapamil in youth newly-diagnosed with T1D appears generally safe and well tolerated with appropriate monitoring. We strongly recommend monitoring for potential side effects including an ECG at screening and an additional ECG once full dosage is reached.ClinicalTrials.gov number: NCT04233034.
RESUMO
Objective: To evaluate the impact of missed or late meal boluses (MLBs) on glycemic outcomes in children and adolescents with type 1 diabetes using automated insulin delivery (AID) systems. Research Design and Methods: AID-treated (Tandem Control-IQ or Medtronic MiniMed 780G) children and adolescents (aged 6-21 years) from Stanford Medical Center and Steno Diabetes Center Copenhagen with ≥10 days of data were included in this two-center, binational, population-based, retrospective, 1-month cohort study. The primary outcome was the association between the number of algorithm-detected MLBs and time in target glucose range (TIR; 70-180 mg/dL). Results: The study included 189 children and adolescents (48% females with a mean ± standard deviation age of 13 ± 4 years). Overall, the mean number of MLBs per day in the cohort was 2.2 ± 0.9. For each additional MLB per day, TIR decreased by 9.7% points (95% confidence interval [CI] 11.3; 8.1), and compared with the quartile with fewest MLBs (Q1), the quartile with most (Q4) had 22.9% less TIR (95% CI: 27.2; 18.6). The age-, sex-, and treatment modality-adjusted probability of achieving a TIR of >70% in Q4 was 1.4% compared with 74.8% in Q1 (P < 0.001). Conclusions: MLBs significantly impacted glycemic outcomes in AID-treated children and adolescents. The results emphasize the importance of maintaining a focus on bolus behavior to achieve a higher TIR and support the need for further research in technological or behavioral support tools to handle MLBs.
RESUMO
BACKGROUND/OBJECTIVE: The main objective of this study is to evaluate the incremental cost-effectiveness (ICER) of the Cambridge hybrid closed-loop automated insulin delivery (AID) algorithm versus usual care for children and adolescents with type 1 diabetes (T1D). METHODS: This multicenter, binational, parallel-controlled trial randomized 133 insulin pump using participants aged 6 to 18 years to either AID (n = 65) or usual care (n = 68) for 6 months. Both within-trial and lifetime cost-effectiveness were analyzed. Analysis focused on the treatment subgroup (n = 21) who received the much more reliable CamAPS FX hardware iteration and their contemporaneous control group (n = 24). Lifetime complications and costs were simulated via an updated Sheffield T1D policy model. RESULTS: Within-trial, both groups had indistinguishable and statistically unchanged health-related quality of life, and statistically similar hypoglycemia, severe hypoglycemia, and diabetic ketoacidosis (DKA) event rates. Total health care utilization was higher in the treatment group. Both the overall treatment group and CamAPS FX subgroup exhibited improved HbA1C (-0.32%, 95% CI: -0.59 to -0.04; P = .02, and -1.05%, 95% CI: -1.43 to -0.67; P < .001, respectively). Modeling projected increased expected lifespan of 5.36 years and discounted quality-adjusted life years (QALYs) of 1.16 (U.K. tariffs) and 1.52 (U.S. tariffs) in the CamAPS FX subgroup. Estimated ICERs for the subgroup were £19 324/QALY (United Kingdom) and -$3917/QALY (United States). For subgroup patients already using continuous glucose monitors (CGM), ICERs were £10 096/QALY (United Kingdom) and -$33 616/QALY (United States). Probabilistic sensitivity analysis generated mean ICERs of £19 342/QALY (95% CI: £15 903/QALY to £22 929/QALY) (United Kingdom) and -$28 283/QALY (95% CI: -$59 607/QALY to $1858/QALY) (United States). CONCLUSIONS: For children and adolescents with T1D on insulin pump therapy, AID using the Cambridge algorithm appears cost-effective below a £20 000/QALY threshold (United Kingdom) and cost saving (United States).
RESUMO
The use of automated insulin delivery (AID) has led to a decrease in the burden of diabetes, allowing for better sleep, decreased anxiety about hypoglycemia, and automatic corrections doses, and meal recognition algorithms have provided "forgiveness" for imprecise carbohydrate (CHO) entries and missed or late meal boluses. We provide a case report and review of the current literature assessing the effect of AID on the burden of meal bolus. The case also demonstrates how sensor and pump data provide insight into insulin bolus behavior, and access to integrated cloud-based data has allowed for virtual patient visits. Glucose sensor metrics provides time in range and time below range, and the sensor-derived glucose management indicator provides an assessment of the long-term risk of complications when a laboratory glycated hemoglobin is not available.
Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/complicações , Hipoglicemia/prevenção & controle , Hipoglicemia/etiologia , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Insulina Regular Humana/uso terapêuticoRESUMO
Background: To evaluate the long-term safety and effectiveness of the Omnipod® 5 Automated Insulin Delivery (AID) System in very young children with type 1 diabetes with up to 2 years of use. Methods: Following a 13-week single-arm, multicenter, pivotal trial that took place after 14 days of standard therapy data collection, participating children (2-5.9 years of age at study enrollment) were provided the option to continue use of the AID system in an extension phase. HbA1c was measured every 3 months, up to 15 months of total use, and continuous glucose monitor metrics were collected through the completion of the extension study (for up to 2 years). Results: Participants (N = 80) completed 18.2 [17.4, 23.4] (median [interquartile range]) total months of AID, inclusive of the 3-month pivotal trial. During the pivotal trial, HbA1c decreased from 7.4% ± 1.0% (57 ± 10.9 mmol/mol) to 6.9% ± 0.7% (52 ± 7.7 mmol/mol, P < 0.0001) and was maintained at 7.0% ± 0.7% (53 ± 7.7 mmol/mol) after 15 months total use (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 57.2% ± 15.3% during standard therapy to 68.1% ± 9.0% during the pivotal trial (P < 0.0001) and was maintained at 67.2% ± 9.3% during the extension phase (P < 0.0001 from standard therapy). Participants spent a median 97.1% of time in Automated Mode during the extension phase, with one episode of severe hypoglycemia and one episode of diabetic ketoacidosis. Conclusion: This evaluation of the Omnipod 5 AID System indicates that long-term use can safely maintain improvements in glycemic outcomes with up to 2 years of use in very young children with type 1 diabetes. Clinical Trials Registration Number: NCT04476472.
Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Pré-Escolar , Insulina/administração & dosagem , Insulina/uso terapêutico , Feminino , Masculino , Glicemia/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas/análise , Hipoglicemia/prevenção & controle , Resultado do Tratamento , Controle Glicêmico/métodos , Automonitorização da GlicemiaRESUMO
OBJECTIVE: Examine patient-reported outcomes (PROs) after the use of t:slim X2 insulin pump with Control-IQ technology (CIQ) in young children with type 1 diabetes. METHODS: Children with type 1 diabetes, ages 2 to < 6 years (n = 102), were randomly assigned 2:1 to either CIQ or standard care (SC) with pump or multiple daily injections (MDI) plus continuous glucose monitoring (CGM) for 13 weeks. Both groups were offered to use CIQ for an additional 13 weeks after the randomized control trial's (RCT) completion. Guardians completed PRO questionnaires at baseline, 13-, and 26-weeks examining hypoglycemia concerns, quality of life, parenting stress, and sleep. At 26 weeks, 28 families participated in user-experience interviews. Repeated measures analyses compared PRO scores between systems used. RESULT: Comparing CIQ vs SC, responses on all 5 PRO surveys favored the CIQ group, showing that CIQ was superior to SC at 26 weeks (p values < 0.05). User-experience interviews indicated significant benefits in optimized glycemic control overall and nighttime control (28 of 28 families endorsed). All but 2/28 families noted substantial reduction in management burden resulting in less mental burden and all but 4 stated that they wanted their children to continue using CIQ. CONCLUSIONS: Families utilizing CIQ experienced glycemic benefits coupled with substantial benefits in PROs, documented in surveys and interviews. Families utilizing CIQ had reduced hypoglycemia concerns and parenting stress, and improved quality of life and sleep. These findings demonstrate the benefit of CIQ in young children with type 1 diabetes that goes beyond documented glycemic benefit.
Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Pré-Escolar , Humanos , Glicemia , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Medidas de Resultados Relatados pelo PacienteRESUMO
Background: The Omnipod® 5 Automated Insulin Delivery (AID) System was shown to be safe and effective following 3 months of use in people with type 1 diabetes (T1D); however, data on the durability of these results are limited. This study evaluated the long-term safety and effectiveness of Omnipod 5 use in people with T1D during up to 2 years of use. Materials and Methods: After a 3-month single-arm, multicenter, pivotal trial in children (6-13.9 years) and adolescents/adults (14-70 years), participants could continue system use in an extension phase. HbA1c was measured every 3 months for up to 15 months; continuous glucose monitor metrics were collected for up to 2 years. Results: Participants (N = 224) completed median (interquartile range) 22.3 (21.7, 22.7) months of AID. HbA1c was reduced in the pivotal trial from 7.7% ± 0.9% in children and 7.2% ± 0.9% in adolescents/adults to 7.0% ± 0.6% and 6.8% ± 0.7%, respectively, (P < 0.0001), and was maintained at 7.2% ± 0.7% and 6.9% ± 0.6% after 15 months (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 52.4% ± 15.6% in children and 63.6% ± 16.5% in adolescents/adults at baseline to 67.9% ± 8.0% and 73.8% ± 10.8%, respectively, during the pivotal trial (P < 0.0001) and was maintained at 65.9% ± 8.9% and 72.9% ± 11.3% during the extension (P < 0.0001 from baseline). One episode of diabetic ketoacidosis and seven episodes of severe hypoglycemia occurred during the extension. Children and adolescents/adults spent median 96.1% and 96.3% of time in Automated Mode, respectively. Conclusion: Our study supports that long-term use of the Omnipod 5 AID System can safely maintain improvements in glycemic outcomes for up to 2 years of use in people with T1D. Clinical Trials Registration Number: NCT04196140.
Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Criança , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Hemoglobinas Glicadas , Sistemas de Infusão de Insulina , Glicemia , Automonitorização da GlicemiaRESUMO
OBJECTIVE: Modeling the effect of meal composition on glucose excursion would help in designing decision support systems (DSS) for type 1 diabetes (T1D) management. In fact, macronutrients differently affect post-prandial gastric retention (GR), rate of appearance (R[Formula: see text]), and insulin sensitivity (S[Formula: see text]). Such variables can be estimated, in inpatient settings, from plasma glucose (G) and insulin (I) data using the Oral glucose Minimal Model (OMM) coupled with a physiological model of glucose transit through the gastrointestinal tract (reference OMM, R-OMM). Here, we present a model able to estimate those quantities in daily-life conditions, using minimally-invasive (MI) technologies, and validate it against the R-OMM. METHODS: Forty-seven individuals with T1D (weight =78±13 kg, age =42±10 yr) underwent three 23-hour visits, during which G and I were frequently sampled while wearing continuous glucose monitoring (CGM) and insulin pump (IP). Using a Bayesian Maximum A Posteriori estimator, R-OMM was identified from plasma G and I measurements, and MI-OMM was identified from CGM and IP data. RESULTS: The MI-OMM fitted the CGM data well and provided precise parameter estimates. GR and R[Formula: see text] model parameters were not significantly different using the MI-OMM and R-OMM (p 0.05) and the correlation between the two S[Formula: see text] was satisfactory ( ρ =0.77). CONCLUSION: The MI-OMM is usable to estimate GR, R[Formula: see text], and S[Formula: see text] from data collected in real-life conditions with minimally-invasive technologies. SIGNIFICANCE: Applying MI-OMM to datasets where meal compositions are available will allow modeling the effect of each macronutrient on GR, R[Formula: see text], and S[Formula: see text]. DSS could finally exploit this information to improve diabetes management.
Assuntos
Diabetes Mellitus Tipo 1 , Resistência à Insulina , Humanos , Adulto , Pessoa de Meia-Idade , Glucose , Diabetes Mellitus Tipo 1/tratamento farmacológico , Resistência à Insulina/fisiologia , Glicemia , Automonitorização da Glicemia , Teorema de Bayes , Insulina , HipoglicemiantesRESUMO
Introduction: Diabetic ketoacidosis (DKA) at diagnosis is associated with short- and long-term complications. We assessed the relationship between DKA status and hemoglobin A1c (A1c) levels in the first year following type 1 diabetes (T1D) diagnosis. Research Design and Methods: The Pilot Teamwork, Targets, Technology, and Tight Control (4T) study offered continuous glucose monitoring to youth with T1D within 1 month of diagnosis. A1c levels were compared between historical (n = 271) and Pilot 4T (n = 135) cohorts stratified by DKA status at diagnosis (DKA: historical = 94, 4T = 67 versus without DKA: historical = 177, 4T = 68). A1c was evaluated using locally estimated scatter plot smoothing. Change in A1c from 4 to 12 months postdiagnosis was evaluated using a linear mixed model. Results: Median age was 9.7 (interquartile range [IQR]: 6.6, 12.7) versus 9.7 (IQR: 6.8, 12.7) years, 49% versus 47% female, 44% versus 39% non-Hispanic White in historical versus Pilot 4T. In historical and 4T cohorts, DKA at diagnosis demonstrated higher A1c at 6 (0.5% [95% confidence interval (CI): 0.21-0.79; P < 0.01] and 0.38% [95% CI: 0.02-0.74; P = 0.04], respectively), and 12 months (0.62% [95% CI: -0.06 to 1.29; P = 0.07] and 0.39% [95% CI: -0.32 to 1.10; P = 0.29], respectively). The highest % time in range (TIR; 70-180 mg/dL) was seen between weeks 15-20 (69%) versus 25-30 (75%) postdiagnosis for youth with versus without DKA in Pilot 4T, respectively. Conclusions: Pilot 4T improved A1c outcomes versus the historical cohort, but those with DKA at diagnosis had persistently elevated A1c throughout the study and intensive diabetes management did not mitigate this difference. DKA prevention at diagnosis may translate into better glycemic outcomes in the first-year postdiagnosis. Clinical Trial Registration: clinicaltrials.gov: NCT04336969.
Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Feminino , Humanos , Masculino , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/etiologia , Hemoglobinas Glicadas , Insulina/uso terapêutico , Projetos PilotoAssuntos
Diabetes Mellitus , Tecnologia Digital , Aplicativos Móveis , Humanos , Diabetes Mellitus/terapia , TecnologiaRESUMO
Background: During MiniMed™ advanced hybrid closed-loop (AHCL) use by adolescents and adults in the pivotal trial, glycated hemoglobin (A1C) was significantly reduced, time spent in range (TIR) was significantly increased, and there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA). The present study investigated the same primary safety and effectiveness endpoints during AHCL use by a younger cohort with type 1 diabetes (T1D). Methods: An intention-to-treat population (N = 160, aged 7-17 years) with T1D was enrolled in a single-arm study at 13 investigational centers. There was a run-in period (â¼25 days) using HCL or sensor-augmented pump with/without predictive low-glucose management, followed by a 3-month study period with AHCL activated at two glucose targets (GTs; 100 and 120 mg/dL) for â¼45 days each. The mean ± standard deviation values of A1C, TIR, mean sensor glucose (SG), coefficient of variation (CV) of SG, time at SG ranges, and insulin delivered between run-in and study were analyzed (Wilcoxon signed-rank test or t-test). Results: Compared with baseline, AHCL use was associated with reduced A1C from 7.9 ± 0.9% (N = 160) to 7.4 ± 0.7% (N = 136) (P < 0.001) and overall TIR increased from the run-in 59.4 ± 11.8% to 70.3 ± 6.5% by end of study (P < 0.001), without change in CV, time spent below range (TBR) <70 mg/dL, or TBR <54 mg/dL. Relative to longer active insulin time (AIT) settings (N = 52), an AIT of 2 h (N = 19) with the 100 mg/dL GT increased mean TIR to 73.4%, reduced TBR <70 mg/dL from 3.5% to 2.2%, and reduced time spent above range (TAR) >180 mg/dL from 28.7% to 24.4%. During AHCL use, there was no severe hypoglycemia or DKA. Conclusions: In children and adolescents with T1D, MiniMed AHCL system use was safe, A1C was lower, and TIR was increased. The lowest GT and shortest AIT were associated with the highest TIR and lowest TBR and TAR, all of which met consensus-recommended glycemic targets. ClinicalTrials.gov ID: NCT03959423.
Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Hipoglicemia , Adolescente , Adulto , Criança , Humanos , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/complicações , Cetoacidose Diabética/etiologia , Glucose , Hemoglobinas Glicadas , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemia/complicações , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Resultado do TratamentoRESUMO
Introduction: Multiple daily injection insulin therapy frequently fails to meet hospital glycemic goals and is prone to hypoglycemia. Automated insulin delivery (AID) with remote glucose monitoring offers a solution to these shortcomings. Research Design and Methods: In a single-arm multicenter pilot trial, we tested the feasibility, safety, and effectiveness of the Omnipod 5 AID System with real-time continuous glucose monitoring (CGM) for up to 10 days in hospitalized patients with insulin-requiring diabetes on nonintensive care unit medical-surgical units. Primary endpoints included the proportion of time in automated mode and percent time-in-range (TIR 70-180 mg/dL) among participants with >48 h of CGM data. Safety endpoints included incidence of severe hypoglycemia and diabetes-related ketoacidosis (DKA). Additional glycemic endpoints, CGM accuracy, and patient satisfaction were also explored. Results: Twenty-two participants were enrolled; 18 used the system for a total of 96 days (mean 5.3 ± 3.1 days per patient), and 16 had sufficient CGM data required for analysis. Median percent time in automated mode was 95% (interquartile range 92%-98%) for the 18 system users, and the 16 participants with >48 h of CGM data achieved an overall TIR of 68% ± 16%, with 0.17% ± 0.3% time <70 mg/dL and 0.06% ± 0.2% time <54 mg/dL. Sensor mean glucose was 167 ± 21 mg/dL. There were no DKA or severe hypoglycemic events. All participants reported satisfaction with the system at study end. Conclusions: The use of AID with a disposable tubeless patch-pump along with remote real-time CGM is feasible in the hospital setting. These results warrant further investigation in randomized trials.
Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Hipoglicemia , Humanos , Glicemia , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Estudos de Viabilidade , Hipoglicemia/induzido quimicamente , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Projetos PilotoAssuntos
Bloqueadores dos Canais de Cálcio , Diabetes Mellitus Tipo 1 , Células Secretoras de Insulina , Verapamil , Criança , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Células Secretoras de Insulina/efeitos dos fármacos , Verapamil/farmacologia , Verapamil/uso terapêutico , Bloqueadores dos Canais de Cálcio/farmacologia , Bloqueadores dos Canais de Cálcio/uso terapêuticoRESUMO
Background: Safety and significant improvement in overall glycated hemoglobin (A1C) and percentage of time spent in (TIR), below (TBR), and above (TAR) glucose range were demonstrated in the pivotal trial of adolescents and adults using the MiniMed™ advanced hybrid closed-loop (AHCL) system with the adjunctive, calibration-required Guardian™ Sensor 3. The present study evaluated early outcomes of continued access study (CAS) participants who transitioned from the pivotal trial investigational system to the approved MiniMed™ 780G system with the non-adjunctive, calibration-free Guardian™ 4 Sensor (MM780G+G4S). Study data were presented alongside those of real-world MM780G+G4S users from Europe, the Middle East, and Africa. Methods: The CAS participants (N = 109, aged 7-17 years and N = 67, aged >17 years) used the MM780G+G4S for 3 months and data of real-world MM780G+G4S system users (N = 10,204 aged ≤15 years and N = 26,099 aged >15 years) were uploaded from September 22, 2021 to December 02, 2022. At least 10 days of real-world continuous glucose monitoring (CGM) data were required for analyses. Glycemic metrics, delivered insulin and system use/interactions underwent descriptive analyses. Results: Time in AHCL and CGM use were >90% for all groups. AHCL exits averaged 0.1/day and there were few blood glucose measurements (BGMs) (0.8/day-1.0/day). Adults in both cohorts met most consensus recommendations for glycemic targets. Pediatric groups met recommendations for %TIR and %TBR, although not those for mean glucose variability and %TAR, possibly due to low use of recommended glucose target (100 mg/dL) and active insulin time (2 h) settings (28.4% in the CAS cohort and 9.4% in the real-world cohort). The CAS pediatric and adult A1C were 7.2% ± 0.7% and 6.8% ± 0.7%, respectively, and there were no serious adverse events. Conclusions: Early clinical use of the MM780G+G4S was safe and involved minimal BGMs and AHCL exits. Consistent with real-world pediatric and adult use, outcomes were associated with achievement of recommended glycemic targets. Clinical Trial Registration number: NCT03959423.
Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Criança , Humanos , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Hemoglobinas Glicadas , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de InsulinaRESUMO
Regular exercise is essential to overall cardiovascular health and well-being in people with type 1 diabetes, but exercise can also lead to increased glycemic disturbances. Automated insulin delivery (AID) technology has been shown to modestly improve glycemic time in range (TIR) in adults with type 1 diabetes and significantly improve TIR in youth with type 1 diabetes. Available AID systems still require some user-initiated changes to the settings and, in some cases, significant pre-planning for exercise. Many exercise recommendations for type 1 diabetes were developed initially for people using multiple daily insulin injections or insulin pump therapy. This article highlights recommendations and practical strategies for using AID around exercise in type 1 diabetes.
RESUMO
Objective: To evaluate the effect of hybrid-closed loop Control-IQ technology (Control-IQ) in randomized controlled trials (RCTs) in subgroups based on baseline characteristics such as race/ethnicity, socioeconomic status (SES), prestudy insulin delivery modality (pump or multiple daily injections), and baseline glycemic control. Methods: Data were pooled and analyzed from 3 RCTs comparing Control-IQ to a Control group using continuous glucose monitoring in 369 participants with type 1 diabetes (T1D) from age 2 to 72 years old. Results: Time in range 70-180 mg/dL (TIR) in the Control-IQ group (n = 256) increased from 57% ± 17% at baseline to 70% ± 11% during follow-up, and in the Control group (n = 113) was 56% ± 15% and 57% ± 14%, respectively (adjusted treatment group difference = 11.5%, 95% confidence interval +9.7% to +13.2%, P < 0.001), an increase of 2.8 h/day on average. Significant reductions in mean glucose, hyperglycemia metrics, hypoglycemic metrics, and HbA1c were also observed. A statistically similar beneficial treatment effect on time in range 70-180 mg/dL was observed across the full age range irrespective of race-ethnicity, household income, prestudy continuous glucose monitor use, or prestudy insulin delivery method. Participants with the highest baseline HbA1c levels showed the greatest improvements in TIR and HbA1c. Conclusion: This pooled analysis of Control-IQ RCTs demonstrates the beneficial effect of Control-IQ in T1D across a broad spectrum of participant characteristics, including racial-ethnic minority, lower SES, lack of prestudy insulin pump experience, and high HbA1c levels. The greatest benefit was observed in participants with the worst baseline glycemic control in whom the auto-bolus feature of the Control-IQ algorithm appears to have substantial impact. Since no subgroups were identified that did not benefit from Control-IQ, hybrid-closed loop technology should be strongly considered for all youth and adults with T1D. Clinical Trials Registry: clinicaltrials.gov; NCT03563313, NCT03844789, and NCT04796779.