Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
1.
Cancers (Basel) ; 16(15)2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39123421

RESUMO

Computer tomography (CT)-guided percutaneous core biopsies are currently the gold standard in diagnostic procedures for patients with bone lesions of unknown kind. CT-guided biopsies can lead to misdiagnosis or repetition of biopsies in case of small or heterogeneous lesions. We hypothesize that molecular image guidance could be used to optimize the biopsy strategy, by supporting the detection of heterogeneous lesions or lesions without radiographic substrate. To evaluate this hypothesis, we investigated if and how the addition of 2-deoxy-2-18F-fluoro-D-glucose-positron emission tomography (18F-FDG-PET)/CT could augment routine CT-guided bone biopsies. To this end, 106 patients who underwent a CT-guided bone biopsy between April 2019 and April 2020, obtained from either a vertebral or peripheral bone, were included. Patients were divided into 2 groups: 36 patients received an 18F-FDG-PET/CT scan prior to their CT-guided bone biopsy (PET group), while 70 patients only had a morphological CT scan (CT group). Histopathology was used to categorize biopsies into five subgroups (inconclusive, benign, malignant or infectious disease, or normal tissue). In the PET group, the number of conclusive biopsies was significantly higher compared to the CT group (N = 33/36 (92%) versus N = 53/70 (76%); p < 0.05). Furthermore, the number of first-try biopsies was lower in the PET group compared to the CT group (1.9 vs. 2.54, p = 0.051). In conclusion, 18F-FDG-PET/CT imaging significantly increased the success rate of first-try CT-guided bone biopsies by showing less inconclusive biopsies and misdiagnosis.

2.
J Nucl Med ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38991755

RESUMO

Following early acceptance by urologists, the use of surgical robotic platforms is rapidly spreading to other surgical fields. This empowerment of surgical perception via robotic advances occurs in parallel to developments in intraoperative molecular imaging. Convergence of these efforts creates a logical incentive to advance the decades-old image-guided robotics paradigm. This yields new radioguided surgery strategies set to optimally exploit the symbiosis between the growing clinical translation of robotics and molecular imaging. These strategies intend to advance surgical precision by increasing dexterity and optimizing surgical decision-making. In this state-of-the-art review, topic-related developments in chemistry (tracer development) and engineering (medical device development) are discussed, and future scientific robotic growth markets for molecular imaging are presented.

3.
J Nucl Med ; 65(8): 1301-1306, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39025649

RESUMO

Liver cancer is a leading cause of cancer deaths worldwide. Surgical resection of superficial hepatic lesions is increasingly guided by the disrupted bile excretion of the fluorescent dye indocyanine green (ICG). To extend this approach to deeper lesions, a dedicated bimodal tracer that facilitates both fluorescence guidance and radioguidance was developed. Methods: A tracer comprising a methylated cyanine-5 (Cy5) fluorescent dye and a mercaptoacetyltriserine chelate (hHEPATO-Cy5) was synthesized and characterized. Cellular uptake and excretion were evaluated in hepatocyte cultures (2-dimensional culture and in vitro lesion model), using a fluorescent bile salt, MitoTracker dye, and methylated Cy5 as a control. After radiolabeling, the pharmacokinetics of 99mTc-hHEPATO-Cy5 were assessed in mice over 24 h (percentage injected dose and percentage injected dose per gram of tissue, SPECT/CT imaging and fluorescence imaging). The ability to provide real-time fluorescence guidance during robot-assisted hepatobiliary surgery was evaluated in a porcine model using ICG as a reference. Results: The unique molecular signature of hHEPATO-Cy5 promotes hepatobiliary excretion. In vitro studies on hepatocytes showed that where methylated Cy5 remained internalized, hHEPATO-Cy5 showed fast clearance (10 min) similar to that of fluorescent bile salt. In vivo use of 99mTc-hHEPATO-Cy5 in mice revealed liver accumulation and rapid biliary clearance. The effectiveness of bile clearance was best exemplified by the 2-orders-of-magnitude reduction in count rate for the gallbladder (P = 0.008) over time. During hepatobiliary surgery in a porcine model, hHEPATO-Cy5 enabled fluorescence-based lesion identification comparable to that of ICG. Conclusion: The bimodal 99mTc-hHEPATO-Cy5 provides an effective means to identify liver lesions. Uniquely, it helps overcome the shortcomings of fluorescence-only approaches by allowing for an extension to in-depth radioguidance.


Assuntos
Carbocianinas , Cirurgia Assistida por Computador , Animais , Carbocianinas/química , Camundongos , Fígado/diagnóstico por imagem , Fígado/metabolismo , Fígado/cirurgia , Distribuição Tecidual , Humanos , Traçadores Radioativos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Suínos , Hepatócitos/metabolismo
4.
Eur J Nucl Med Mol Imaging ; 51(10): 3040-3054, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38900308

RESUMO

To meet the growing demand for intraoperative molecular imaging, the development of compatible imaging agents plays a crucial role. Given the unique requirements of surgical applications compared to diagnostics and therapy, maximizing translational potential necessitates distinctive imaging agent designs. For effective surgical guidance, exogenous signatures are essential and are achievable through a diverse range of imaging labels such as (radio)isotopes, fluorescent dyes, or combinations thereof. To achieve optimal in vivo utility a balanced molecular design of the tracer as a whole is required, which ensures a harmonious effect of the imaging label with the affinity and specificity (e.g., pharmacokinetics) of a pharmacophore/targeting moiety. This review outlines common design strategies and the effects of refinements in the molecular imaging agent design on the agent's pharmacological profile. This includes the optimization of affinity, pharmacokinetics (including serum binding and target mediated background), biological clearance route, the achievable signal intensity, and the effect of dosing hereon.


Assuntos
Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Imagem Molecular/métodos , Animais , Desenho de Fármacos
5.
Expert Rev Med Devices ; 21(5): 349-358, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38722051

RESUMO

INTRODUCTION: Surgery and biomedical imaging encompass a big share of the medical-device market. The ever-mounting demand for precision surgery has driven the integration of these two into the field of image-guided surgery. A key-question herein is how imaging modalities can guide the surgical decision-making process. Through performance-based design, chemists, engineers, and doctors need to build a bridge between imaging technologies and surgical challenges. AREAS-COVERED: This perspective article highlights the complementary nature between the technological design of an image-guidance modality and the type of procedure performed. The specific roles of the involved professionals, imaging technologies, and surgical indications are addressed. EXPERT-OPINION: Molecular-image-guided surgery has the potential to advance pre-, intra- and post-operative tissue characterization. To achieve this, surgeons need the access to well-designed indication-specific chemical-agents and detection modalities. Hereby, some technologies stimulate exploration ('go'), while others stimulate caution ('stop'). However, failing to adequately address the indication-specific needs rises the risk of incorrect tool employment and sub-optimal surgical performance. Therefore, besides the availability of new technologies, market growth is highly dependent on the practical nature and impact on real-life clinical care. While urology currently takes the lead in the widespread implementation of image-guidance technologies, the topic is generic and its popularity spreads rapidly within surgical oncology.


Assuntos
Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Diagnóstico por Imagem/métodos , Diagnóstico por Imagem/instrumentação , Medicina de Precisão/métodos , Medicina de Precisão/instrumentação , Equipamentos e Provisões
6.
Artigo em Inglês | MEDLINE | ID: mdl-38012448

RESUMO

PURPOSE: Prostate-specific membrane antigen (PSMA) is increasingly considered as a molecular target to achieve precision surgery for prostate cancer. A Delphi consensus was conducted to explore expert views in this emerging field and to identify knowledge and evidence gaps as well as unmet research needs that may help change practice and improve oncological outcomes for patients. METHODS: One hundred and five statements (scored by a 9-point Likert scale) were distributed through SurveyMonkey®. Following evaluation, a consecutive second round was performed to evaluate consensus (16 statements; 89% response rate). Consensus was defined using the disagreement index, assessed by the research and development project/University of California, Los Angeles appropriateness method. RESULTS: Eighty-six panel participants (72.1% clinician, 8.1% industry, 15.1% scientists, and 4.7% other) participated, most with a urological background (57.0%), followed by nuclear medicine (22.1%). Consensus was obtained on the following: (1) The diagnostic PSMA-ligand PET/CT should ideally be taken < 1 month before surgery, 1-3 months is acceptable; (2) a 16-20-h interval between injection of the tracer and surgery seems to be preferred; (3) PSMA targeting is most valuable for identification of nodal metastases; (4) gamma, fluorescence, and hybrid imaging are the preferred guidance technologies; and (5) randomized controlled clinical trials are required to define oncological value. Regarding surgical margin assessment, the view on the value of PSMA-targeted surgery was neutral or inconclusive. A high rate of "cannot answer" responses indicates further study is necessary to address knowledge gaps (e.g., Cerenkov or beta-emissions). CONCLUSIONS: This Delphi consensus provides guidance for clinicians and researchers that implement or develop PSMA-targeted surgery technologies. Ultimately, however, the consensus should be backed by randomized clinical trial data before it may be implemented within the guidelines.

7.
Biomolecules ; 13(6)2023 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-37371522

RESUMO

BACKGROUND: The occurrence of accidental nerve damage during surgery and the increasing application of image guidance during head-and-neck surgery have highlighted the need for molecular targeted nerve-sparing interventions. The implementation of such interventions relies on the availability of nerve-specific tracers. In this paper, we describe the development of a truncated peptide that has an optimized affinity for protein zero (P0), the most abundant protein in myelin. METHODS AND MATERIALS: Further C- and N-terminal truncation was performed on the lead peptide Cy5-P0101-125. The resulting nine Cy5-labelled peptides were characterized based on their photophysical properties, P0 affinity, and in vitro staining. These characterizations were combined with evaluation of the crystal structure of P0, which resulted in the selection of the optimized tracer Cy5-P0112-125. A near-infrared Cy7-functionalized derivative (Cy7-P0112-125) was used to perform an initial evaluation of fluorescence-guided surgery in a porcine model. RESULTS: Methodological truncation of the 26-amino-acid lead compound Cy5-P0101-125 resulted in a size reduction of 53.8% for the optimized peptide Cy5-P0112-125. The peptide design and the 1.5-fold affinity gain obtained after truncation could be linked to interactions observed in the crystal structure of the extracellular portion of P0. The near-infrared analogue Cy7-P0112-125 supported nerve illumination during fluorescence-guided surgery in the head-and-neck region in a porcine model. CONCLUSIONS: Methodological truncation yielded a second-generation P0-specific peptide. Initial surgical evaluation suggests that the peptide can support molecular targeted nerve imaging.


Assuntos
Aminoácidos , Proteína P0 da Mielina , Animais , Suínos , Proteína P0 da Mielina/análise , Proteína P0 da Mielina/química , Proteína P0 da Mielina/metabolismo , Aminoácidos/análise , Fluorescência , Peptídeos/análise , Bainha de Mielina/metabolismo
8.
Eur J Nucl Med Mol Imaging ; 50(9): 2861-2871, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37036490

RESUMO

OBJECTIVE: To determine the diagnostic accuracy of the hybrid tracer indocyanine green (ICG)-Technetium-99 m(99mTc)-nanocolloid compared to sequential tracers of 99mTc-nanocolloid and free-ICG in detecting tumor-positive lymph nodes (LN) during primary surgery in prostate cancer (PCa) patients. INTRODUCTION: Image-guided surgery strategies can help visualize individual lymphatic drainage patterns and sentinel lymph nodes (SLNs) in PCa patients. For lymphatic mapping radioactive, fluorescent and hybrid tracers are being clinically exploited. In this prospective randomized phase II trial, we made a head-to-head comparison between ICG-99mTc-nanocolloid (hybrid group) and 99mTc-nanocolloid and subsequent free-ICG injection (sequential group). METHODS: PCa patients with a >5% risk of lymphatic involvement according to the 2012 Briganti nomogram and planned for prostatectomy were included and randomized (1:1) between ultrasound-guided intraprostatic tracer administration of ICG-99mTc-nanocolloid (n = 69) or 99mTc-nanocolloid (n = 69) 5 h before surgery. Preoperative lymphoscintigraphy and SPECT/CT were performed to define the locations of the SLNs. Additionally, all participants in the sequential group received an injection of free-ICG at time of surgery. Subsequently, all (S)LNs were dissected using fluorescence guidance followed by an extended pelvic lymph node dissection (ePLND). The primary outcome was the total number of surgically removed (S)LNs and tumor-positive (S)LNs. RESULTS: The total number of surgically removed (S)LN packages was 701 and 733 in the hybrid and sequential groups, respectively (p = 0.727). The total number of fluorescent LNs retrieved was 310 and 665 nodes in the hybrid and sequential groups, respectively (p < 0.001). However, no statistically significant difference was observed in the corresponding number of tumor-positive nodes among the groups (44 vs. 33; p = 0.470). Consequently, the rate of tumor-positive fluorescent LNs was higher in the hybrid group (7.4%) compared to the sequential group (2.6%; p = 0.002), indicating an enhanced positive predictive value for the hybrid approach. There was no difference in complications within 90 days after surgery (p = 0.78). CONCLUSIONS: The hybrid tracer ICG-99mTc-nanocolloid improved the positive predictive value for tumor-bearing LNs while minimizing the number of fluorescent nodes compared to the sequential tracer approach. Consequently, the hybrid tracer ICG-99mTc-nanocolloid enables the most reliable and minimal invasive method for LN staging in PCa patients.


Assuntos
Neoplasias da Próstata , Linfonodo Sentinela , Masculino , Humanos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Linfonodo Sentinela/patologia , Biópsia de Linfonodo Sentinela/métodos , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Excisão de Linfonodo , Verde de Indocianina , Agregado de Albumina Marcado com Tecnécio Tc 99m , Linfonodos/patologia
9.
Eur J Nucl Med Mol Imaging ; 50(8): 2282-2291, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36929210

RESUMO

BACKGROUND: Lymph node (LN) metastasis is a relevant predictor for survival in patients with a.o. penile cancer (PeCa), malignant melanoma. The sentinel node (SN) procedure comprises targeted resection of the first tumour-draining SNs. Here, the hybrid tracer indocyanine green (ICG)-99mTc-nanocolloid has been used for several years to combine optical and nuclear detection. Recently, the resource of the nanocolloid precursor stopped production and the precursor was replaced by a different but chemically comparable colloid, nanoscan. Our aim was to study the performance of ICG-99mTc-nanoscan compared to ICG-99mTc-nanocolloid from a nuclear and surgical perspective. METHODS: Twenty-four patients with either PeCa or head-and-neck (H&N) melanoma and scheduled for a SN procedure were included. The initial group (n = 11) received ICG-99mTc-nanocolloid until no longer available; the second group (n = 13) received ICG-99mTc-nanoscan. Tracer uptake was assessed on lymphoscintigraphy and single-photon emission (SPECT). Intraoperatively, SNs were identified using gamma tracing and fluorescence imaging. Ex vivo (back-table) measurements were conducted to quantify the fluorescence emissions. Chemical analysis was performed to compare the ICG assembly on both precursors. RESULTS: The mean tracer uptake in the SNs was similar for ICG-99mTc-nanocolloid (2.2 ± 4.3%ID) and ICG-99mTc-nanoscan (1.8 ± 2.6%ID; p = 0.68). 3 SNs (interquartile range (IQR) 3-4) were detected on lymphoscintigraphy in PeCa patients receiving ICG-99mTc-nanoscan compared to 2 SNs (IQR 2-3) in PeCa patients receiving ICG-99mTc-nanocolloid (p = 0.045), no differences were observed in H&N patients. Back-table measurements of resected SNs revealed a lower total fluorescence intensity in the ICG-99mTc-nanoscan group (24*109 arbitrary units (A.U) IQR 1.6*109-14*109 in the ICG-99mTc-nanocolloid group versus 4.6*109 A.U. IQR 2.4*109-42*109 in the ICG-99mTc-nanoscan group, p = 0.0054). This was consistent with a larger degree of "stacked" ICG observed in the nanoscan formulation. No tracer-related adverse events were reported. CONCLUSIONS: Based on this retrospective analysis, we can conclude that ICG-99mTc-nanoscan has similar capacity for SN identification as ICG-99mTc-nanocolloid and can safely be implemented in SN procedures.


Assuntos
Melanoma , Medicina Nuclear , Neoplasias Penianas , Linfonodo Sentinela , Masculino , Humanos , Verde de Indocianina , Biópsia de Linfonodo Sentinela/métodos , Estudos Retrospectivos , Linfonodo Sentinela/cirurgia , Melanoma/diagnóstico por imagem , Melanoma/cirurgia , Melanoma/patologia , Compostos Radiofarmacêuticos , Metástase Linfática , Neoplasias Penianas/patologia , Agregado de Albumina Marcado com Tecnécio Tc 99m
10.
J Clin Med ; 12(3)2023 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-36769566

RESUMO

The targeted delivery of anti-cancer drugs and isotopes is one of the most pursued goals in anti-cancer therapy. One of the prime examples of such an application is the intra-arterial injection of microspheres containing cytostatic drugs or radioisotopes during hepatic embolization procedures. Therapy based on the application of microspheres revolves around vascular occlusion, complemented with local therapy in the form of trans-arterial chemoembolization (TACE) or radioembolization (TARE). The broadest implementation of these embolization strategies currently lies within the treatment of untreatable hepatocellular cancer (HCC) and metastatic colorectal cancer. This review aims to describe the state-of-the-art TACE and TARE technologies investigated in the clinical setting for HCC and addresses current trials and new developments. In addition, chemical properties and advancements in microsphere carrier systems are evaluated, and possible improvements in embolization therapy based on the modification of and functionalization with therapeutical loads are explored.

11.
Bone Joint Res ; 12(1): 72-79, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36649933

RESUMO

AIMS: Arthroplasty surgery of the knee and hip is performed in two to three million patients annually. Periprosthetic joint infections occur in 4% of these patients. Debridement, antibiotics, and implant retention (DAIR) surgery aimed at cleaning the infected prosthesis often fails, subsequently requiring invasive revision of the complete prosthetic reconstruction. Infection-specific imaging may help to guide DAIR. In this study, we evaluated a bacteria-specific hybrid tracer (99mTc-UBI29-41-Cy5) and its ability to visualize the bacterial load on femoral implants using clinical-grade image guidance methods. METHODS: 99mTc-UBI29-41-Cy5 specificity for Stapylococcus aureus was assessed in vitro using fluorescence confocal imaging. Topical administration was used to highlight the location of S. aureus cultured on femoral prostheses using fluorescence imaging and freehand single photon emission CT (fhSPECT) scans. Gamma counting and fhSPECT were used to quantify the bacterial load and monitor cleaning with chlorhexidine. Microbiological culturing helped to relate the imaging findings with the number of (remaining) bacteria. RESULTS: Bacteria could be effectively stained in vitro and on prostheses, irrespective of the presence of biofilm. Infected prostheses revealed bacterial presence on the transition zone between the head and neck, and in the screw hole. Qualitative 2D fluorescence images could be complemented with quantitative 3D fhSPECT scans. Despite thorough chlorhexidine treatments, 28% to 44% of the signal remained present in the locations of the infection that were identified using imaging, which included 500 to 2,000 viable bacteria. CONCLUSION: The hybrid tracer 99mTc-UBI29-41-Cy5 allowed effective bacterial staining. Qualitative real-time fluorescence guidance could be effectively combined with nuclear imaging that enables quantitative monitoring of the effectiveness of cleaning strategies.Cite this article: Bone Joint Res 2023;12(1):72-79.

13.
J Robot Surg ; 17(1): 131-140, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35397108

RESUMO

Fluorescence imaging is increasingly being implemented in surgery. One of the drawbacks of its application is the need to switch back-and-forth between fluorescence- and white-light-imaging settings and not being able to dissect safely under fluorescence guidance. The aim of this study was to engineer 'click-on' fluorescence detectors that transform standard robotic instruments into molecular sensing devices that enable the surgeon to detect near-infrared (NIR) fluorescence in a white-light setting. This NIR-fluorescence detector setup was engineered to be press-fitted onto standard forceps instruments of the da Vinci robot. Following system characterization in a phantom setting (i.e., spectral properties, sensitivity and tissue signal attenuation), the performance with regard to different clinical indocyanine green (ICG) indications (e.g., angiography and lymphatic mapping) was determined via robotic surgery in pigs. To evaluate in-human applicability, the setup was also used for ICG-containing lymph node specimens from robotic prostate cancer surgery. The resulting Click-On device allowed for NIR ICG signal identification down to a concentration of 4.77 × 10-6 mg/ml. The fully assembled system could be introduced through the trocar and grasping, and movement abilities of the instrument were preserved. During surgery, the system allowed for the identification of blood vessels and assessment of vascularization (i.e., bowel, bladder and kidney), as well as localization of pelvic lymph nodes. During human specimen evaluation, it was able to distinguish sentinel from non-sentinel lymph nodes. With this introduction of a NIR-fluorescence Click-On sensing detector, a next step is made towards using surgical instruments in the characterization of molecular tissue aspects.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Suínos , Animais , Procedimentos Cirúrgicos Robóticos/métodos , Biópsia de Linfonodo Sentinela/métodos , Linfonodos/cirurgia , Verde de Indocianina , Instrumentos Cirúrgicos
14.
Molecules ; 27(24)2022 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-36558148

RESUMO

BACKGROUND: Surgically induced nerve damage is a common but debilitating side effect. By developing tracers that specifically target the most abundant protein in peripheral myelin, namely myelin protein zero (P0), we intend to support fluorescence-guided nerve-sparing surgery. To that end, we aimed to develop a dimeric tracer that shows a superior affinity for P0. METHODS: Following truncation of homotypic P0 protein-based peptide sequences and fluorescence labeling, the lead compound Cy5-P0101-125 was selected. Using a bifunctional fluorescent dye, the dimeric Cy5-(P0101-125)2 was created. Assessment of the performance of the mono- and bi-labeled compounds was based on (photo)physical evaluation. This was followed by in vitro assessment in P0 expressing Schwannoma cell cultures by means of fluorescence confocal imaging (specificity, location of binding) and flow cytometry (binding affinity; KD). RESULTS: Dimerization resulted in a 1.5-fold increase in affinity compared to the mono-labeled counterpart (70.3 +/- 10.0 nM vs. 104.9 +/- 16.7 nM; p = 0.003) which resulted in a 4-fold increase in staining efficiency in P0 expressing Schwannoma cells. Presence of two targeting vectors also improves a pharmacokinetics of labeled compounds by lowering serum binding and optical stability by preventing dye stacking. CONCLUSIONS: Dimerization of the nerve-targeting peptide P0101-125 proves a valid strategy to improve P0 targeting.


Assuntos
Proteína P0 da Mielina , Neurilemoma , Humanos , Proteína P0 da Mielina/química , Proteína P0 da Mielina/metabolismo , Dimerização , Peptídeos/metabolismo
15.
Cancer Imaging ; 22(1): 48, 2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36068619

RESUMO

Molecular imaging technologies are increasingly used to diagnose, monitor, and guide treatment of i.e., cancer. In this review, the current status and future prospects of the use of molecular imaging as an instrument to help realize precision surgery is addressed with focus on the main components that form the conceptual basis of intraoperative molecular imaging. Paramount for successful interventions is the relevance and accessibility of surgical targets. In addition, selection of the correct combination of imaging agents and modalities is critical to visualize both microscopic and bulk disease sites with high affinity and specificity. In this context developments within engineering/imaging physics continue to drive the growth of image-guided surgery. Particularly important herein is enhancement of sensitivity through improved contrast and spatial resolution, features that are critical if sites of cancer involvement are not to be overlooked during surgery. By facilitating the connection between surgical planning and surgical execution, digital surgery technologies such as computer-aided visualization nicely complement these technologies. The complexity of image guidance, combined with the plurality of technologies that are becoming available, also drives the need for evaluation mechanisms that can objectively score the impact that technologies exert on the performance of healthcare professionals and outcome improvement for patients.


Assuntos
Neoplasias , Cirurgia Assistida por Computador , Humanos , Imagem Molecular , Neoplasias/diagnóstico por imagem , Neoplasias/cirurgia , Cirurgia Assistida por Computador/métodos
16.
Am J Nucl Med Mol Imaging ; 12(2): 74-80, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35535122

RESUMO

Developments within the field of image-guided surgery are ever expanding, driven by collective involvement of clinicians, researchers, and industry. While the general conception of the potential of image-guided surgery is to improve surgical outcome, the specific motives and goals that drive can differ between the different expert groups. To establish the current and future role of intra-operative image guidance within the field of image-guided surgery a Delphi consensus survey was conducted during the 2nd European Congress on Image-guided surgery. This multidisciplinary survey included questions on the conceptual potential and clinical value of image-guided surgery and was aimed at defining specific areas of research and development in the field in order to stimulate further advances towards precision surgery. Obtained results based on questionnaires filled in by 56 panel experts (clinicians: N=30, researchers: N=20 and industry: N=6) were discussed during a dedicated expert discussion session during the conference. The outcome of this Delphi consensus is indicative of the potential improvements offered by image-guided surgery and of the need for further research in this emerging field, that can be enriched by the identification of reliable molecular targets.

17.
EJNMMI Res ; 12(1): 14, 2022 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-35254544

RESUMO

BACKGROUND: With the rise of prostate-specific membrane antigen (PSMA) radioguided surgery, which is performed using a microdosing regime, demand for visual target confirmation via fluorescence guidance is growing. While proven very effective for radiotracers, microdosing approaches the detection limit for fluorescence imaging. Thus, utility will be highly dependent on the tracer performance, the sensitivity of the fluorescence camera used, and the degree of background signal. Using a porcine model the ability to perform robot-assisted radical prostatectomy under fluorescence guidance using the bimodal or rather hybrid PSMA tracer (99mTc-EuK-(SO3)Cy5-mas3) was studied, while employing the tracer in a microdosing regime. This was followed by ex vivo evaluation in surgical specimens obtained from prostate cancer patients. RESULTS: T50% blood and T50% urine were reached at 85 min and 390 min, in, respectively, blood and urine. Surgical fluorescence imaging allowed visualization of the prostate gland based on the basal PSMA-expression in porcine prostate. Together, in vivo visualization of the prostate and urinary excretion suggests at least an interval of > 7 h between tracer administration and surgery. Confocal microscopy of excised tissues confirmed tracer uptake in kidney and prostate, which was confirmed with PSMA IHC. No fluorescence was detected in other excised tissues. Tumor identification based on ex vivo fluorescence imaging of human prostate cancer specimens correlated with PSMA IHC. CONCLUSION: Intraoperative PSMA-mediated fluorescence imaging with a microdosing approach was shown to be feasible. Furthermore, EuK-(SO3)Cy5-mas3 allowed tumor identification in human prostate samples, underlining the translational potential of this novel tracer. Trial registration Approval for use of biological material for research purposes was provided by the Translational Research Board of the Netherlands Cancer Institute-Antoni van Leeuwenhoek hospital (NKI-AvL) under reference IRBm19-273 (22/10/2019).

18.
Eur J Nucl Med Mol Imaging ; 49(5): 1743-1753, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34748059

RESUMO

INTRODUCTION: Previous studies indicated that location and amount of detected sentinel lymph nodes (SLNs) in prostate cancer (PCa) are influenced where SLN-tracer is deposited within the prostate. To validate whether intratumoral (IT) tracer injection helps to increase identification of tumor-positive lymph nodes (LNs) better than intraprostatic (IP) tracer injection, a prospective randomized phase II trial was performed. METHODS: PCa patients with a > 5% risk of lymphatic involvement were randomized between ultrasound-guided transrectal injection of indocyanine green-[99mTc]Tc-nanocolloid in 2 depots of 1 mL in the tumor (n = 55, IT-group) or in 4 depots of 0.5 mL in the peripheral zone of the prostate (n = 58, IP-group). Preoperative lymphoscintigraphy and SPECT/CT were used to define the location of the SLNs. SLNs were dissected using combination of radio- and fluorescence-guidance, followed by extended pelvic LN dissection and robot-assisted radical prostatectomy. Outcome measurements were number of tumor-bearing SNs, tumor-bearing LNs, removed nodes, number of patients with nodal metastases, and metastasis-free survival (MFS) of 4-7-year follow-up data. RESULTS: IT-injection did not result in significant difference of removed SLNs (5.0 vs 6.0, p = 0.317) and histologically positive SLNs (28 vs 22, p = 0.571). However, in IT-group, the SLN-positive nodes were 73.7% of total positive nodes compared to 37.3% in IP-group (p = 0.015). Moreover, significantly more node-positive patients were found in IT-group (42% vs 24%, p = 0.045), which did not result in worse MFS. In two patients (3.6%) from whom the IT-tracer injection only partly covered intraprostatic tumor spread, nodal metastases in ePLND without tumor-positive SNs were yielded. CONCLUSIONS: The percentage-positive SLNs found after IT-injection were significantly higher compared to IP-injection. Significantly more node-positive patients were found using IT-injection, which did not affect MFS. IT-injection failed to detect nodal metastases from non-index satellite lesions. Therefore, we suggest to combine IT- and IP-tracer injections in men with visible tumor on imaging.


Assuntos
Neoplasias da Próstata , Linfonodo Sentinela , Drenagem , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Masculino , Estudos Prospectivos , Neoplasias da Próstata/patologia , Linfonodo Sentinela/patologia , Biópsia de Linfonodo Sentinela/métodos
19.
Int J Comput Assist Radiol Surg ; 17(1): 211-218, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34333740

RESUMO

PURPOSE: Sentinel lymph node biopsy is a routine procedure for nodal staging in penile cancer. Most commonly, this procedure is guided by radioactive tracers, providing various forms of preoperative and intraoperative guidance. This is further extended with fluorescence imaging using hybrid radioactive-fluorescence tracers. Alternatively, a magnetic-based approach has become available using superparamagnetic iron-oxide nanoparticles (SPIONs). This study investigates a novel freehand magnetic particle imaging and navigation modality (fhMPI) for intraoperative localization, along with a hybrid approach, combining magnetic and fluorescence guidance. MATERIALS AND METHODS: The fhMPI set-up was built with a surgical navigation device, optical tracking system and magnetometer probe. A dedicated reconstruction software based on a look-up-table method was used to reconstruct a superficial 3D volume of the SPION distribution in tissue. For fluorescence guidance, indocyanine green (ICG) was added to the SPIONs. The fhMPI modality was characterized in phantoms, ex vivo human skin and in vivo porcine surgery. RESULTS: Phantom and human skin explants illustrated that the current fhMPI modality had a sensitivity of 2.2 × 10-2 mg/mL SPIONs, a resolving power of at least 7 mm and a depth penetration up to 1.5 cm. Evaluation during porcine surgery showed that fhMPI allowed for an augmented reality image overlay of the tracer distribution in tissue, as well as 3D virtual navigation. Besides, using the hybrid approach, fluorescence imaging provided a visual confirmation of localized nodes. CONCLUSION: fhMPI is feasible in vivo, providing 3D imaging and navigation for magnetic nanoparticles in the operating room, expanding the guidance possibilities during magnetic sentinel lymph node procedures. Furthermore, the integration of ICG provides the ability to visually refine and confirm correct localization. Further clinical evaluation should verify these findings in human patients as well.


Assuntos
Imageamento Tridimensional , Cirurgia Assistida por Computador , Animais , Humanos , Verde de Indocianina , Imagem Óptica , Biópsia de Linfonodo Sentinela , Suínos
20.
J Nucl Med ; 63(1): 51-56, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33990404

RESUMO

In penile squamous cell carcinoma (pSCC), primary surgery aims to obtain oncologically safe margins while minimizing mutilation. Surgical guidance provided by receptor-specific tracers could potentially improve margin detection and reduce unnecessary excision of healthy tissue. Here, we present the first results of a prospective feasibility study for real-time intraoperative visualization of pSCC using a fluorescent mesenchymal-epithelial transition factor (c-MET) receptor targeting tracer (EMI-137). Methods: EMI-137 tracer performance was initially assessed ex vivo (n = 10) via incubation of freshly excised pSCC in a solution containing EMI-137 (500 nM). The in vivo potential of c-MET targeting and intraoperative tumor visualization was assessed after intravenous administration of EMI-137 to 5 pSCC patients scheduled for surgical resection using a cyanine-5 fluorescence camera. Fluorescence imaging results were related to standard pathologic tumor evaluation and c-MET immunohistochemistry. Three of the 5 in vivo patients also underwent a sentinel node resection after local administration of the hybrid tracer indocyanine green- 99mTc-nanocolloid, which could be imaged using a near-infrared fluorescence camera. Results: No tracer-related adverse events were encountered. Both ex vivo and in vivo, EMI-137 enabled c-MET-based tumor visualization in all patients. Histopathologic analyses showed that all pSCCs expressed c-MET, with expression levels of at least 70% in 14 of 15 patients. Moreover, the highest c-MET expression levels were seen on the outside rim of the tumors, and a visual correlation was found between c-MET expression and fluorescence signal intensity. No complications were encountered when combining primary tumor targeting with lymphatic mapping. As such, simultaneous use of cyanine-5 and indocyanine green in the same patient proved to be feasible. Conclusion: Fluorescence imaging of c-MET receptor- expressing pSCC tumors after intravenous injection of EMI-137 was shown to be feasible and can be combined with fluorescence-based lymphatic mapping. This combination is unique and paves the way toward further development of this surgical guidance approach.


Assuntos
Verde de Indocianina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA