Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Nature ; 615(7953): 605-609, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36949334

RESUMO

Type Ia supernovae are cosmic distance indicators1,2, and the main source of iron in the Universe3,4, but their formation paths are still debated. Several dozen supersoft X-ray sources, in which a white dwarf accretes hydrogen-rich matter from a non-degenerate donor star, have been observed5 and suggested as Type Ia supernovae progenitors6-9. However, observational evidence for hydrogen, which is expected to be stripped off the donor star during the supernova explosion10, is lacking. Helium-accreting white dwarfs, which would circumvent this problem, have been predicted for more than 30 years (refs. 7,11,12), including their appearance as supersoft X-ray sources, but have so far escaped detection. Here we report a supersoft X-ray source with an accretion disk whose optical spectrum is completely dominated by helium, suggesting that the donor star is hydrogen-free. We interpret the luminous and supersoft X-rays as resulting from helium burning near the surface of the accreting white dwarf. The properties of our system provide evidence for extended pathways towards Chandrasekhar-mass explosions based on helium accretion, in particular for stable burning in white dwarfs at lower accretion rates than expected so far. This may allow us to recover the population of the sub-energetic so-called Type Iax supernovae, up to 30% of all Type Ia supernovae13, within this scenario.

2.
Nature ; 604(7906): 447-450, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35444319

RESUMO

Nova explosions are caused by global thermonuclear runaways triggered in the surface layers of accreting white dwarfs1-3. It has been predicted4-6 that localized thermonuclear bursts on white dwarfs can also take place, similar to type-I X-ray bursts observed in accreting neutron stars. Unexplained rapid bursts from the binary system TV Columbae, in which mass is accreted onto a moderately strong magnetized white dwarf from a low-mass companion, have been observed on several occasions in the past 40 years7-11. During these bursts, the optical/ultraviolet luminosity increases by a factor of more than three in less than an hour and fades in around ten hours. Fast outflows have been observed in ultraviolet spectral lines7, with velocities of more than 3,500 kilometres per second, comparable to the escape velocity from the white dwarf surface. Here we report on optical bursts observed in TV Columbae and in two additional accreting systems, EI Ursae Majoris and ASASSN-19bh. The bursts have a total energy of approximately 10-6  times than those of classical nova explosions (micronovae) and bear a strong resemblance to type-I X-ray bursts12-14. We exclude accretion or stellar magnetic reconnection events as their origin and suggest thermonuclear runaway events in magnetically confined accretion columns as a viable explanation.

3.
Nature ; 603(7899): 52-57, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35236977

RESUMO

All disc-accreting astrophysical objects produce powerful disc winds. In compact binaries containing neutron stars or black holes, accretion often takes place during violent outbursts. The main disc wind signatures during these eruptions are blue-shifted X-ray absorption lines, which are preferentially seen in disc-dominated 'soft states'1,2. By contrast, optical wind-formed lines have recently been detected in 'hard states', when a hot corona dominates the luminosity3. The relationship between these signatures is unknown, and no erupting system has as yet revealed wind-formed lines between the X-ray and optical bands, despite the many strong resonance transitions in this ultraviolet (UV) region4. Here we report that the transient neutron star binary Swift J1858.6-0814 exhibits wind-formed, blue-shifted absorption lines associated with C IV, N V and He II in time-resolved UV spectroscopy during a luminous hard state, which we interpret as a warm, moderately ionized outflow component in this state. Simultaneously observed optical lines also display transient blue-shifted absorption. Decomposing the UV data into constant and variable components, the blue-shifted absorption is associated with the former. This implies that the outflow is not associated with the luminous flares in the data. The joint presence of UV and optical wind features reveals a multi-phase and/or spatially stratified evaporative outflow from the outer disc5. This type of persistent mass loss across all accretion states has been predicted by radiation-hydrodynamic simulations6 and helps to explain the shorter-than-expected duration of outbursts7.

6.
Nature ; 592(7856): 704-707, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33911275

RESUMO

Quasi-periodic eruptions (QPEs) are very-high-amplitude bursts of X-ray radiation recurring every few hours and originating near the central supermassive black holes of galactic nuclei1,2. It is currently unknown what triggers these events, how long they last and how they are connected to the physical properties of the inner accretion flows. Previously, only two such sources were known, found either serendipitously or in archival data1,2, with emission lines in their optical spectra classifying their nuclei as hosting an actively accreting supermassive black hole3,4. Here we report observations of QPEs in two further galaxies, obtained with a blind and systematic search of half of the X-ray sky. The optical spectra of these galaxies show no signature of black hole activity, indicating that a pre-existing accretion flow that is typical of active galactic nuclei is not required to trigger these events. Indeed, the periods, amplitudes and profiles of the QPEs reported here are inconsistent with current models that invoke radiation-pressure-driven instabilities in the accretion disk5-9. Instead, QPEs might be driven by an orbiting compact object. Furthermore, their observed properties require the mass of the secondary object to be much smaller than that of the main body10, and future X-ray observations may constrain possible changes in their period owing to orbital evolution. This model could make QPEs a viable candidate for the electromagnetic counterparts of so-called extreme-mass-ratio inspirals11-13, with considerable implications for multi-messenger astrophysics and cosmology14,15.

8.
Br J Dermatol ; 184(1): 151-155, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32282055

RESUMO

BACKGROUND: Allergic contact dermatitis (ACD) to cosmetics is widely reported. To ensure we are accurately diagnosing ACD, patch test series should be continually reviewed to identify relevant and emerging allergens and highlight those that are outdated. The current British Society for Cutaneous Allergy (BSCA) facial series recommends 26 allergens and was last modified in 2012. OBJECTIVES: To review and update the BSCA facial series. METHODS: We retrospectively reviewed the results from 12 UK and Ireland patch test centres' facial series from January 2016 to December 2017. We recorded the number of allergens tested in each centre and the detection rate for each allergen. Using a 0·3% positive rate as the inclusion threshold, we established which allergens in the BSCA facial series had positive patch test rates < 0·3% and > 0·3%. Allergens not in the BSCA facial series that had a positive patch test rate > 0·3% were identified. RESULTS: Overall, 4224 patients were patch tested to the facial series. The number of allergens included in individual centres' facial series ranged from 24 to 66, with a total of 103 allergens tested across all centres. Twelve of the 26 allergens in the BSCA facial series had a positive patch test rate < 0·3% and 14 had a rate > 0·3%. Twenty-five allergens not recommended in the BSCA facial series had a positive patch test rate > 0·3%. CONCLUSIONS: This audit has highlighted the significant variation in practice that exists among patch test centres, despite a recommended facial series. The BSCA facial series has been updated and now contains 24 allergens. Fifteen allergens remain, 11 allergens have been dropped and nine new allergens have been added.


Assuntos
Dermatite Alérgica de Contato , Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Humanos , Irlanda/epidemiologia , Testes do Emplastro , Estudos Retrospectivos
12.
Br J Dermatol ; 181(4): 811-817, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30703264

RESUMO

BACKGROUND: (Meth)acrylates are potent sensitizers and a common cause of allergic contact dermatitis (ACD). The frequency of (meth)acrylate ACD has increased with soaring demand for acrylic nails. A preliminary audit has suggested a significant rate of positive patch tests to (meth)acrylates using aimed testing in patients providing a clear history of exposure. To date, (meth)acrylates have not been routinely tested in the baseline patch test series in the U.K. and Europe. OBJECTIVES: To determine whether inclusion of 2-hydroxyethyl methacrylate (2-HEMA) 2% in petrolatum (pet.) in the baseline series detects cases of treatable (meth)acrylate ACD. METHODS: During 2016-2017, 15 U.K. dermatology centres included 2-HEMA in the extended baseline patch test series. Patients with a history of (meth)acrylate exposure, or who tested positive to 2-HEMA, were selectively tested with a short series of eight (meth)acrylate allergens. RESULTS: In total 5920 patients were consecutively patch tested with the baseline series, of whom 669 were also tested with the (meth)acrylate series. Overall, 102 of 5920 (1·7%) tested positive to 2-HEMA and 140 (2·4%) to at least one (meth)acrylate. Had 2-HEMA been excluded from the baseline series, (meth)acrylate allergy would have been missed in 36 of 5920 (0·6% of all patients). The top (meth)acrylates eliciting a positive reaction were 2-HEMA (n = 102, 1·7%), 2-hydroxypropyl methacrylate (n = 61, 1·0%) and 2-hydroxyethyl acrylate (n = 57, 1·0%). CONCLUSIONS: We recommend that 2-HEMA 2% pet. be added to the British baseline patch test series. We also suggest a standardized short (meth)acrylate series, which is likely to detect most cases of (meth)acrylate allergy.


Assuntos
Acrilatos/imunologia , Alérgenos/imunologia , Dermatite Alérgica de Contato/diagnóstico , Metacrilatos/efeitos adversos , Testes do Emplastro/métodos , Adolescente , Adulto , Idoso , Cosméticos/efeitos adversos , Cosméticos/química , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Unhas , Estudos Prospectivos , Reino Unido/epidemiologia , Adulto Jovem
15.
Nature ; 547(7664): 425-427, 2017 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-28748924

RESUMO

Newly formed black holes of stellar mass launch collimated outflows (jets) of ionized matter that approach the speed of light. These outflows power prompt, brief and intense flashes of γ-rays known as γ-ray bursts (GRBs), followed by longer-lived afterglow radiation that is detected across the electromagnetic spectrum. Measuring the polarization of the observed GRB radiation provides a direct probe of the magnetic fields in the collimated jets. Rapid-response polarimetric observations of newly discovered bursts have probed the initial afterglow phase, and show that, minutes after the prompt emission has ended, the degree of linear polarization can be as high as 30 per cent-consistent with the idea that a stable, globally ordered magnetic field permeates the jet at large distances from the central source. By contrast, optical and γ-ray observations during the prompt phase have led to discordant and often controversial results, and no definitive conclusions have been reached regarding the origin of the prompt radiation or the configuration of the magnetic field. Here we report the detection of substantial (8.3 ± 0.8 per cent from our most conservative simulation), variable linear polarization of a prompt optical flash that accompanied the extremely energetic and long-lived prompt γ-ray emission from GRB 160625B. Our measurements probe the structure of the magnetic field at an early stage of the jet, closer to its central black hole, and show that the prompt phase is produced via fast-cooling synchrotron radiation in a large-scale magnetic field that is advected from the black hole and distorted by dissipation processes within the jet.

16.
Br J Dermatol ; 177(6): 1708-1715, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28494107

RESUMO

BACKGROUND: There is a significant rate of sensitization worldwide to the oxidized fragrance terpenes limonene and linalool. Patch testing to oxidized terpenes is not routinely carried out; the ideal patch test concentration is unknown. OBJECTIVES: To determine the best test concentrations for limonene and linalool hydroperoxides, added to the British baseline patch test series, to optimize detection of true allergy and to minimize irritant reactions. METHODS: During 2013-2014, 4563 consecutive patients in 12 U.K. centres were tested to hydroperoxides of limonene in petrolatum (pet.) 0·3%, 0·2% and 0·1%, and hydroperoxides of linalool 1·0%, 0·5% and 0·25% pet. Irritant reactions were recorded separately from doubtful reactions. Concomitant reactions to other fragrance markers and clinical relevance were documented. RESULTS: Limonene hydroperoxide 0·3% gave positive reactions in 241 (5·3%) patients, irritant reactions in 93 (2·0%) and doubtful reactions in 110 (2·4%). Linalool hydroperoxide 1·0% gave positive reactions in 352 (7·7%), irritant reactions in 178 (3·9%) and doubtful reactions in 132 (2·9%). A total of 119 patients with crescendo reactions to 0·3% limonene would have been missed if only tested with 0·1% and 131 patients with crescendo reactions to 1·0% linalool would have been missed if only tested with 0·25%. In almost two-thirds of patients with positive patch tests to limonene and linalool the reaction was clinically relevant. The majority of patients did not react to any fragrance marker in the baseline series. CONCLUSIONS: We recommend that limonene hydroperoxides be tested at 0·3% and linalool hydroperoxides at 1·0% in the British baseline patch test series.


Assuntos
Hipersensibilidade a Drogas/diagnóstico , Inseticidas/efeitos adversos , Limoneno/efeitos adversos , Monoterpenos/efeitos adversos , Perfumes/efeitos adversos , Monoterpenos Acíclicos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes do Emplastro
18.
Dermatol Online J ; 21(5)2015 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-26295863

RESUMO

Topical calcineurin inhibitors have been used outside their approved indications for a number of conditions, including topical steroid-induced rosacea. However, tacrolimus ointment itself has been reported to trigger rosacea in a small number of cases. We report a case of a rosacea-like eruption in a 39-year-old woman occurring after the use of pimecrolimus cream for 12 months for atopic dermatitis. Withdrawal of pimecrolimus combined with treatment with oral lymecycline, topical metronidazole, and an emollient resulted in resolution of the eruption. There have been 5 previously reported cases of a topical pimecrolimus-induced rosacea-like eruption suggesting that this rare side-effect may be a class effect of all topical calcineurin inhibitors. Dermatologists prescribing these drugs should be aware of this uncommon complication and may wish to warn patients of its occurrence as a potential side-effect when using topical calcineurin inhibitors in facial skin in adults.


Assuntos
Toxidermias/etiologia , Dermatoses Faciais/induzido quimicamente , Rosácea/induzido quimicamente , Tacrolimo/análogos & derivados , Administração Cutânea , Adulto , Fármacos Dermatológicos/administração & dosagem , Fármacos Dermatológicos/efeitos adversos , Toxidermias/diagnóstico , Dermatoses Faciais/diagnóstico , Feminino , Humanos , Peptidilprolil Isomerase/antagonistas & inibidores , Rosácea/diagnóstico , Tacrolimo/administração & dosagem , Tacrolimo/efeitos adversos
19.
Br J Dermatol ; 171(2): 292-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24702129

RESUMO

BACKGROUND: The oxidized forms of the fragrance terpenes limonene and linalool are known to cause allergic contact dermatitis. Significant rates of contact allergy to these fragrances have been reported in European studies and in a recent worldwide study. Patch testing to oxidized terpenes is not routinely carried out either in the U.K. or in other centres internationally. OBJECTIVES: To investigate the prevalence of contact allergy to oxidized limonene and linalool in the U.K. METHODS: Between 1 August 2011 and 31 December 2012, 4731 consecutive patients in 13 U.K. dermatology departments were tested for hydroperoxides of limonene 0·3% pet., hydroperoxides of linalool 1·0% pet., stabilized limonene 10·0% pet. and stabilized linalool 10·0% pet. Doubtful (?+) and equivocal (±) reactions were grouped together as irritant reactions. RESULTS: Two hundred and thirty-seven patients (5·0%) had a positive patch test reaction to hydroperoxides of limonene 0·3% pet. and 281 (5·9%) to hydroperoxides of linalool 1·0% pet. Irritant reactions to one or both oxidized terpenes were found in 242 patients (7·3%). Eleven patients (0·2%) had a positive patch test reaction to the stabilized terpenes alone. CONCLUSIONS: This large, multicentre U.K. audit shows a significant rate of allergy to the hydroperoxides of limonene and linalool plus a high rate of irritant reactions. Testing to the oxidized forms alone captures the majority (97·0%; 411 of 422) of positive reactions; testing to nonoxidized terpenes appears to be less useful. We recommend that the hydroperoxides of limonene and linalool be added to an extended baseline patch test series.


Assuntos
Cicloexenos/toxicidade , Dermatite Alérgica de Contato/epidemiologia , Monoterpenos/toxicidade , Terpenos/toxicidade , Monoterpenos Acíclicos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Alérgenos/toxicidade , Criança , Pré-Escolar , Feminino , Humanos , Irritantes/toxicidade , Limoneno , Masculino , Pessoa de Meia-Idade , Testes do Emplastro , Perfumes/toxicidade , Reino Unido/epidemiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA