Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Int J Mol Sci ; 23(24)2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36555555

RESUMO

Additive manufacturing or 3D printing applying polycaprolactone (PCL)-based medical devices represents an important branch of tissue engineering, where the sterilization method is a key process for further safe application in vitro and in vivo. In this study, the authors intend to access the most suitable gamma radiation conditions to sterilize PCL-based scaffolds in a preliminary biocompatibility assessment, envisioning future studies for airway obstruction conditions. Three radiation levels were considered, 25 kGy, 35 kGy and 45 kGy, and evaluated as regards their cyto- and biocompatibility. All three groups presented biocompatible properties, indicating an adequate sterility condition. As for the cytocompatibility analysis, devices sterilized with 35 kGy and 45 kGy showed better results, with the 45 kGy showing overall improved outcomes. This study allowed the selection of the most suitable sterilization condition for PCL-based scaffolds, aiming at immediate future assays, by applying 3D-customized printing techniques to specific airway obstruction lesions of the trachea.


Assuntos
Poliésteres , Engenharia Tecidual , Engenharia Tecidual/métodos , Esterilização/métodos , Raios gama , Alicerces Teciduais , Impressão Tridimensional
2.
Rev Bras Ter Intensiva ; 34(3): 351-359, 2022.
Artigo em Português, Inglês | MEDLINE | ID: mdl-36351067

RESUMO

OBJECTIVE: To develop a simple, robust, safe and efficient invasive mechanical ventilator that can be used in remote areas of the world or war zones where the practical utility of more sophisticated equipment is limited by considerations of maintainability, availability of parts, transportation and/or cost. METHODS: The device implements the pressure-controlled continuous mandatory ventilation mode, complemented by a simple assist-control mode. Continuous positive airway pressure is also possible. The consumption of compressed gases is minimized by avoiding a continuous flow of oxygen or air. Respiratory rates and inspiration/expiration time ratios are electronically determined, and an apnea/power loss alarm is provided. RESULTS: The pressure profiles were measured for a range of conditions and found to be adjustable within a ± 2.5cmH2O error margin and stable well within this range over a 41-hour period. Respiratory cycle timing parameters were precise within a few percentage points over the same period. The device was tested for durability for an equivalent period of four months. Chemical and biological tests failed to identify any contamination of the gas by volatile organic compounds or microorganisms. A ventilation test on a large animal, in comparison with a well established ventilator, showed that the animal could be adequately ventilated over a period of 60 minutes, without any noticeable negative aftereffects during the subsequent 24-hour period. CONCLUSION: This ventilator design may be viable, after further animal tests and formal approval by the competent authorities, for clinical application in the abovementioned atypical circumstances.


OBJETIVO: Desenvolver um ventilador mecânico invasivo simples, resistente, seguro e eficiente que possa ser utilizado em áreas remotas do mundo ou zonas de guerra, em que a utilidade prática de equipamentos mais sofisticados é limitada por questões de manutenção, disponibilidade de peças, transporte e/ou custo. MÉTODOS: O dispositivo implementa o modo de ventilação mandatória contínua com pressão controlada, complementado por um simples modo assisto-controlado. Pode-se também utilizar a pressão positiva contínua nas vias aéreas. Ao se evitar o fluxo contínuo de oxigênio ou ar, minimiza-se o consumo de gases comprimidos. As taxas respiratórias e as relações de tempo de inspiração e expiração são determinadas eletronicamente. Além disso, conta com um alarme de apneia/falta de energia. RESULTADOS: Os perfis de pressão foram medidos para uma série de condições, sendo considerados ajustáveis dentro de uma margem de erro de ± 2,5cmH2O, e foram considerados bem estáveis dentro dessa variação durante um período de 41 horas. Os parâmetros de tempo do ciclo respiratório foram precisos dentro de alguns pontos percentuais durante o mesmo período. O dispositivo foi testado quanto à durabilidade por um período equivalente a 4 meses. Os testes químicos e biológicos não conseguiram identificar qualquer contaminação do gás por compostos orgânicos voláteis ou micro-organismos. Em comparação com um ventilador bem estabelecido, o teste de ventilação em um animal de grande porte mostrou que este poderia ser ventilado adequadamente durante um período de 60 minutos, sem quaisquer efeitos negativos perceptíveis durante o período subsequente de 24 horas. CONCLUSÃO: Este projeto de ventilador pode ser viável após novos testes em animais e aprovação formal pelas autoridades competentes, para aplicação clínica nas circunstâncias atípicas anteriormente mencionadas.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Ventiladores Mecânicos , Animais , Humanos , Respiração Artificial
3.
Cancers (Basel) ; 14(18)2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36139528

RESUMO

BACKGROUND: Pleural effusion (PE) is common in advanced-stage lung cancer patients and is related to poor prognosis. Identification of cancer cells is the standard method for the diagnosis of a malignant PE (MPE). However, it only has moderate sensitivity. Thus, more sensitive diagnostic tools are urgently needed. METHODS: The present study aimed to discover potential protein targets to distinguish malignant pleural effusion (MPE) from other non-malignant pathologies. We have collected PE from 97 patients to explore PE proteomes by applying state-of-the-art liquid chromatography-mass spectrometry (LC-MS) to identify potential biomarkers that correlate with immunohistochemistry assessment of tumor biopsy or with survival data. Functional analyses were performed to elucidate functional differences in PE proteins in malignant and benign samples. Results were integrated into a clinical risk prediction model to identify likely malignant cases. Sensitivity, specificity, and negative predictive value were calculated. RESULTS: In total, 1689 individual proteins were identified by MS-based proteomics analysis of the 97 PE samples, of which 35 were diagnosed as malignant. A comparison between MPE and benign PE (BPE) identified 58 differential regulated proteins after correction of the p-values for multiple testing. Furthermore, functional analysis revealed an up-regulation of matrix intermediate filaments and cellular movement-related proteins. Additionally, gene ontology analysis identified the involvement of metabolic pathways such as glycolysis/gluconeogenesis, pyruvate metabolism and cysteine and methionine metabolism. CONCLUSION: This study demonstrated a partial least squares regression model with an area under the curve of 98 and an accuracy of 0.92 when evaluated on the holdout test data set. Furthermore, highly significant survival markers were identified (e.g., PSME1 with a log-rank of 1.68 × 10-6).

4.
Rev. bras. ter. intensiva ; 34(3): 351-359, jul.-set. 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1407751

RESUMO

RESUMO Objetivo: Desenvolver um ventilador mecânico invasivo simples, resistente, seguro e eficiente que possa ser utilizado em áreas remotas do mundo ou zonas de guerra, em que a utilidade prática de equipamentos mais sofisticados é limitada por questões de manutenção, disponibilidade de peças, transporte e/ou custo. Métodos: O dispositivo implementa o modo de ventilação mandatória contínua com pressão controlada, complementado por um simples modo assisto-controlado. Pode-se também utilizar a pressão positiva contínua nas vias aéreas. Ao se evitar o fluxo contínuo de oxigênio ou ar, minimiza-se o consumo de gases comprimidos. As taxas respiratórias e as relações de tempo de inspiração e expiração são determinadas eletronicamente. Além disso, conta com um alarme de apneia/falta de energia. Resultados: Os perfis de pressão foram medidos para uma série de condições, sendo considerados ajustáveis dentro de uma margem de erro de ± 2,5cmH2O, e foram considerados bem estáveis dentro dessa variação durante um período de 41 horas. Os parâmetros de tempo do ciclo respiratório foram precisos dentro de alguns pontos percentuais durante o mesmo período. O dispositivo foi testado quanto à durabilidade por um período equivalente a 4 meses. Os testes químicos e biológicos não conseguiram identificar qualquer contaminação do gás por compostos orgânicos voláteis ou micro-organismos. Em comparação com um ventilador bem estabelecido, o teste de ventilação em um animal de grande porte mostrou que este poderia ser ventilado adequadamente durante um período de 60 minutos, sem quaisquer efeitos negativos perceptíveis durante o período subsequente de 24 horas. Conclusão: Este projeto de ventilador pode ser viável após novos testes em animais e aprovação formal pelas autoridades competentes, para aplicação clínica nas circunstâncias atípicas anteriormente mencionadas.


ABSTRACT Objective: To develop a simple, robust, safe and efficient invasive mechanical ventilator that can be used in remote areas of the world or war zones where the practical utility of more sophisticated equipment is limited by considerations of maintainability, availability of parts, transportation and/or cost. Methods: The device implements the pressure-controlled continuous mandatory ventilation mode, complemented by a simple assist-control mode. Continuous positive airway pressure is also possible. The consumption of compressed gases is minimized by avoiding a continuous flow of oxygen or air. Respiratory rates and inspiration/expiration time ratios are electronically determined, and an apnea/power loss alarm is provided. Results: The pressure profiles were measured for a range of conditions and found to be adjustable within a ± 2.5cmH2O error margin and stable well within this range over a 41-hour period. Respiratory cycle timing parameters were precise within a few percentage points over the same period. The device was tested for durability for an equivalent period of four months. Chemical and biological tests failed to identify any contamination of the gas by volatile organic compounds or microorganisms. A ventilation test on a large animal, in comparison with a well established ventilator, showed that the animal could be adequately ventilated over a period of 60 minutes, without any noticeable negative aftereffects during the subsequent 24-hour period. Conclusion: This ventilator design may be viable, after further animal tests and formal approval by the competent authorities, for clinical application in the abovementioned atypical circumstances.

5.
Port J Card Thorac Vasc Surg ; 29(1): 35-43, 2022 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-35471220

RESUMO

The role of endobronchial ultrasound (EBUS) and trans-esophageal endobronchial ultrasound (EUS-B) in lung cancer is well established and scientifically validated. There is increasing data that endosonography is a crucial tool for the diagnosis of central lung lesions, and mediastinal staging and restaging of non-small cell lung cancer patients. The present article reviews the technical aspects of EBUS and EUS-B and focus on the last published research regarding its value in lung cancer.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Endossonografia , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Mediastino/diagnóstico por imagem , Estadiamento de Neoplasias
6.
BMC Pulm Med ; 22(1): 68, 2022 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-35183132

RESUMO

INTRODUCTION: Central airway obstruction (CAO) represents a pathological condition that can lead to airflow limitation of the trachea, main stem bronchi, bronchus intermedius or lobar bronchus. MAIN BODY: It is a common clinical situation consensually considered under-diagnosed. Management of patients with CAO can be difficult and deciding on the best treatment approach represents a medical challenge. This work intends to review CAO classifications, causes, treatments and its therapeutic limitations, approaching benign and malign presentations. Three illustrative cases are further presented, supporting the clinical problem under review. CONCLUSION: Management of CAO still remains a challenge. The available options are not always effective nor free from complications. A new generation of costume-tailored airway stents, associated with stem cell-based therapy, could be an option in specific clinical situations.


Assuntos
Obstrução das Vias Respiratórias , Brônquios , Traqueia , Obstrução das Vias Respiratórias/classificação , Obstrução das Vias Respiratórias/diagnóstico , Obstrução das Vias Respiratórias/etiologia , Obstrução das Vias Respiratórias/terapia , Humanos
8.
Diagnostics (Basel) ; 10(2)2020 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-32033429

RESUMO

A detailed transabdominal and transvaginal ultrasound examination, performed by an expert examiner, could render a similar diagnostic performance to computed tomography for assessing pelvic/abdominal tumor spread disease in women with epithelial ovarian cancer (EOC). This study aimed to describe and assess the feasibility of lung and intercostal upper abdomen ultrasonography as pretreatment imaging of EOC metastases of supradiaphragmatic and subdiaphragmatic areas. A preoperative ultrasound examination of consecutive patients suspected of having EOC was prospectively performed using transvaginal, transabdominal, and intercostal lung and upper abdomen ultrasonography. A surgical-pathological examination was the reference standard to ultrasonography. Among 77 patients with histologically proven EOC, supradiaphragmatic disease was detected in 13 cases: pleural effusions on the right (n = 12) and left (n = 8) sides, nodular lesions on diaphragmatic pleura (n = 9), focal lesion in lung parenchyma (n = 1), and enlarged cardiophrenic lymph nodes (n = 1). Performance (described with area under the curve) of combined transabdominal and intercostal upper abdomen ultrasonography for subdiaphragmatic areas (n = 77) included the right and left diaphragm peritoneum (0.754 and 0.575 respectively), spleen hilum (0.924), hepatic hilum (0.701), and liver and spleen parenchyma (0.993 and 1.0 respectively). It was not possible to evaluate the performance of lung ultrasonography for supradiaphragmatic disease because only some patients had this region surgically explored. Preoperative lung and intercostal upper abdomen ultrasonography performed in patients with EOC can add valuable information for supradiaphragmatic and subdiaphragmatic regions. A reliable reference standard to test method performance is an area of future research. A multidisciplinary approach to ovarian cancer utilizing lung ultrasonography may assist in clinical decision-making.

9.
Arch Bronconeumol ; 56(11): 695-696, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35373770
10.
Int J Oncol ; 55(5): 1033-1048, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31793656

RESUMO

The formation of distant metastasis resulting from vascular dissemination is one of the leading causes of mortality in non­small cell lung cancer (NSCLC). This metastatic dissemination initiates with the adhesion of circulating cancer cells to the endothelium. The minimal requirement for the binding of leukocytes to endothelial E­selectins and subsequent transmigration is the epitope of the fucosylated glycan, sialyl Lewis x (sLex), attached to specific cell surface glycoproteins. sLex and its isomer sialyl Lewis a (sLea) have been described in NSCLC, but their functional role in cancer cell adhesion to endothelium is still poorly understood. In this study, it was hypothesised that, similarly to leukocytes, sLe glycans play a role in NSCLC cell adhesion to E­selectins. To assess this, paired tumour and normal lung tissue samples from 18 NSCLC patients were analyzed. Immunoblotting and immunohistochemistry assays demonstrated that tumour tissues exhibited significantly stronger reactivity with anti­sLex/sLea antibody and E­selectin chimera than normal tissues (2.2­ and 1.8­fold higher, respectively), as well as a higher immunoreactive score. High sLex/sLea expression was associated with bone metastasis. The overall α1,3­fucosyltransferase (FUT) activity was increased in tumour tissues, along with the mRNA levels of FUT3, FUT6 and FUT7, whereas FUT4 mRNA expression was decreased. The expression of E­selectin ligands exhibited a weak but significant correlation with the FUT3/FUT4 and FUT7/FUT4 ratios. Additionally, carcinoembryonic antigen (CEA) was identified in only 8 of the 18 tumour tissues; CEA­positive tissues exhibited significantly increased sLex/sLea expression. Tumour tissue areas expressing CEA also expressed sLex/sLea and showed reactivity to E­selectin. Blot rolling assays further demonstrated that CEA immunoprecipitates exhibited sustained adhesive interactions with E­selectin­expressing cells, suggesting CEA acts as a functional protein scaffold for E­selectin ligands in NSCLC. In conclusion, this work provides the first demonstration that sLex/sLea are increased in primary NSCLC due to increased α1,3­FUT activity. sLex/sLea is carried by CEA and confers the ability for NSCLC cells to bind E­selectins, and is potentially associated with bone metastasis. This study contributes to identifying potential future diagnostic/prognostic biomarkers and therapeutic targets for lung cancer.


Assuntos
Antígeno Carcinoembrionário/metabolismo , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Selectina E/metabolismo , Fucosiltransferases/metabolismo , Neoplasias Pulmonares/metabolismo , Antígeno Sialil Lewis X/metabolismo , Idoso , Carcinoma Pulmonar de Células não Pequenas/patologia , Adesão Celular/fisiologia , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Polissacarídeos/metabolismo
12.
J Clin Med ; 7(11)2018 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-30412994

RESUMO

BACKGROUND: Different anesthetic protocols may influence endobronchial ultrasound-guided needle aspiration (EBUS-TBNA) outcomes, patient comfort, and even safety. In this study, two anesthesia techniques were assessed and compared for EBUS-TBNA. METHODS: A prospective, multicenter study was carried out. Patients were allocated to Group 1 (general anesthesia with neuromuscular blockade and controlled ventilation) and Group 2 (intravenous sedation). EBUS-TBNA accuracy was the primary outcome. Safety, patient comfort and satisfaction, and operators' difficulties were defined as secondary outcomes. RESULTS: Of the 115 patients enrolled (Group 1 = 59, Group 2 = 56), EBUS-TBNA was performed for hilar or mediastinal lesion diagnosis and lung cancer staging in, respectively, 77 (67%) and 38 (33%) patients. The numbers of lymph nodes stations (1.8 ± 1.0 vs. 1.7 ± 1.0, p = 0.472) and punctures per station (6.9 ± 3.1 vs. 6.0 ± 2.5, p = 0.084) were similar between groups. Adequate samples were obtained from 109 patients (97.3%) with similar diagnostic accuracy. Procedure duration was not significantly different (p = 0.348). Hemodynamic parameters and systolic and diastolic blood pressures were higher in Group 1 at the beginning and at the end of the procedure. Adverse events were equally distributed, and no significant differences were found regarding patient satisfaction and bronchoscopist/anesthesiologist difficulties. CONCLUSIONS: The type of anesthesia used did not influence EBUS-TBNA outcomes. EBUS-TBNA performed under sedation or general anesthesia did not affect the diagnostic yield, complication rate, and patients' comfort and satisfaction.

14.
Respiration ; 95(1): 44-54, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28881352

RESUMO

BACKGROUND: Airway stenting (AS) commenced in Europe circa 1987 with the first placement of a dedicated silicone airway stent. Subsequently, over the last 3 decades, AS was spread throughout Europe, using different insertion techniques and different types of stents. OBJECTIVES: This study is an international survey conducted by the European Association of Bronchology and Interventional Pulmonology (EABIP) focusing on AS practice within 26 European countries. METHODS: A questionnaire was sent to all EABIP National Delegates in February 2015. National delegates were responsible for obtaining precise and objective data regarding the current AS practice in their country. The deadline for data collection was February 2016. RESULTS: France, Germany, and the UK are the 3 leading countries in terms of number of centres performing AS. These 3 nations represent the highest ranked nations within Europe in terms of gross national income. Overall, pulmonologists perform AS exclusively in 5 countries and predominately in 12. AS is performed almost exclusively in public hospitals. AS performed under general anaesthesia is the rule for the majority of institutions, and local anaesthesia is an alternative in 9 countries. Rigid bronchoscopy techniques are predominant in 20 countries. Amongst commercially available stents, both Dumon and Ultraflex are by far the most commonly deployed. Finally, 11 countries reported that AS is an economically viable activity, while 10 claimed that it is not. CONCLUSION: This EABIP survey demonstrates that there is significant heterogeneity in AS practice within Europe. Therapeutic bronchoscopy training and economic issues/reimbursement for procedures are likely to be the primary reasons explaining these findings.


Assuntos
Broncoscopia/estatística & dados numéricos , Pneumologia/estatística & dados numéricos , Stents/estatística & dados numéricos , Broncoscopia/instrumentação , Europa (Continente) , Humanos , Pneumologia/instrumentação , Pneumologia/métodos , Pneumologia/organização & administração , Inquéritos e Questionários
15.
Tumour Biol ; 37(1): 953-61, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26264617

RESUMO

In lung cancer, the immune cell compartment of tumor-draining lymph nodes (TDLNs) dictate the response against tumors. This response is predominantly triggered by myeloid antigen-presenting cells (mAPCs) that capture antigens and, if matured, prime anti-tumor-specific T cell populations. However, the clinical role of mAPCs infiltrated in TDLN from lung cancer patients is poorly understood. The purpose of this study was to study mAPCs in TDLN from lung adenocarcinoma patients, in comparison to individuals with non-malignant diseases, using minimally invasive sampling methods. Mediastinal lymph nodes were assessed by endobronchial ultrasound-transbronchial needle aspiration (EBUS-TBNA). mAPCs were characterized by flow cytometry and cytokine expression by quantitative polymerase chain reaction. The association with tumor burden, overall survival, and response to treatment was assessed. TDLN from lung adenocarcinoma patients (n = 24) showed a reduced immune cell compartment, but a higher level of infiltrating mAPCs, when compared with control lymph nodes (n = 17). A decreased expression of co-stimulatory molecules CD80/CD86 by TDLN and blood mAPC was observed. TDLN showed lower levels of TNF-α and IL-12 and increased levels of immunosuppressive cytokines TGF-ß and IL-10. The IL-12 expression was inversely correlated with the percentage of infiltrated tumor cells, while IL-10 was directly correlated. Patients with lower expression of IL-12 in TDLN or lower expression of CD80/86 in blood mAPCs had worse overall survival and response to therapy. mAPCs of lung adenocarcinoma patients express less co-stimulatory molecules, and within TDLN, the cytokine profile is biased towards a tolerance-inducing phenotype. Patients with enhanced immune parameters have better survival and response to treatment. EBUS-TBNA allows the collection of viable specimens from TDLN that may provide further insight on relevant immunological mechanisms.


Assuntos
Adenocarcinoma/imunologia , Adenocarcinoma/metabolismo , Citocinas/metabolismo , Neoplasias Pulmonares/imunologia , Neoplasias Pulmonares/metabolismo , Células Mieloides/imunologia , Células Mieloides/metabolismo , Adenocarcinoma/diagnóstico , Adenocarcinoma/mortalidade , Adenocarcinoma de Pulmão , Adulto , Idoso , Idoso de 80 Anos ou mais , Células Apresentadoras de Antígenos/imunologia , Células Apresentadoras de Antígenos/metabolismo , Biomarcadores , Citocinas/genética , Endossonografia , Feminino , Regulação da Expressão Gênica , Humanos , Imunofenotipagem , Mediadores da Inflamação/metabolismo , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/mortalidade , Linfonodos/imunologia , Linfonodos/metabolismo , Linfonodos/patologia , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Prognóstico
17.
Respiration ; 87(4): 270-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24480900

RESUMO

BACKGROUND: Transthoracic ultrasound (US) is an important instrument to identify pleural effusions and safely conduct invasive procedures. It also allows systematic scanning of the pleural surface, though its value remains uncertain for differentiation between malignant (MPE) and nonmalignant pleural effusion (non-MPE) in routine clinical practice. OBJECTIVES: To evaluate the utility of US features to predict malignancy in undiagnosed pleural effusions in a real-life clinical setting. METHODS: The US features of 154 consecutive patients with a pleural effusion were prospectively assessed. Anonymous images were recorded by an operator blinded to the clinical and radiological results. The US findings were classified by independent reviewers and compared to the final diagnosis. RESULTS: A total of 133 patients were included (age 67 ± 16 years; BMI 25.1 ± 4.6; 54.1% females). The final diagnosis was MPE in 66 cases and non-MPE in 67 cases. US had an overall sensitivity of 80.3%, a specificity of 83.6%, and positive and negative predictive values of 82.8 and 81.2%, respectively, for the detection of malignancy. US accuracy was 81.9%. The presence of pleural/diaphragmatic nodules, pleural/diaphragmatic thickness >10 mm, and a swirling sign was significantly different between both groups (p < 0.001). Lung air bronchogram sign and a septated US pattern were more common in non-MPE patients (p < 0.01). The existence of nodularity and the absence of air bronchograms were more likely to indicate malignancy (OR 29.0, 95% CI 7.65-110.08 and OR 10.4, 95% CI 1.65-65.752, respectively). CONCLUSIONS: In the presence of an undiagnosed pleural effusion, US morphological characteristics can aid in differentiating MPE from non-MPE. Pleural/diaphragmatic nodularity was the most relevant feature although no finding was pathognomonic of MPE.


Assuntos
Derrame Pleural Maligno/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Pneumologia/métodos , Ultrassonografia , Adulto Jovem
18.
Eur Respir J ; 43(1): 233-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23900983

RESUMO

Peripheral lung lesions are sometimes difficult to reach even with endobronchial ultrasound (EBUS) and insufficient material is often obtained by transbronchial forceps biopsy. Cryoprobes can be used for performing tissue biopsies. We evaluated the safety and feasibility of the cryoprobe in combination with EBUS for the diagnosis of peripheral lung lesion. Patients with peripheral lung lesions of up to 4 cm were enrolled. After identifying the lung lesion by radial EBUS, forceps biopsies and cryobiopsies were performed in a randomised order. We evaluated safety and feasibility, and compared diagnostic yield and sample size. 39 patients were randomised and the peripheral lung lesion was reached in 31. The overall diagnostic yield was 60.5% and, in the lesions reached by EBUS, it was 74.2%. In 19 cases, the diagnosis was made with forceps as well as cryobiopsy and, in four cases, only with cryobiopsy. Cryobiopsies were significantly larger than forceps biopsies (11.17 mm(2) versus 4.69 mm(2), p<0.001). We observed one case of moderate bleeding. Transbronchial cryobiopsy with EBUS guidance is safe and useful to obtain histological samples. Larger tissue samples can be obtained by cryoprobe.


Assuntos
Biópsia/métodos , Broncoscopia/métodos , Criocirurgia/métodos , Endossonografia/métodos , Neoplasias Pulmonares/patologia , Pulmão/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia/instrumentação , Estudos de Coortes , Criocirurgia/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Instrumentos Cirúrgicos , Tomografia Computadorizada por Raios X
19.
J Bras Pneumol ; 39(4): 447-54, 2013.
Artigo em Inglês, Português | MEDLINE | ID: mdl-24068266

RESUMO

OBJECTIVE: To assess the sensitivity and specificity of flow-volume curves in detecting central airway obstruction (CAO), and to determine whether their quantitative and qualitative criteria are associated with the location, type and degree of obstruction. METHODS: Over a four-month period, we consecutively evaluated patients with bronchoscopy indicated. Over a one-week period, all patients underwent clinical evaluation, flow-volume curve, bronchoscopy, and completed a dyspnea scale. Four reviewers, blinded to quantitative and clinical data, and bronchoscopy results, classified the morphology of the curves. A fifth reviewer determined the morphological criteria, as well as the quantitative criteria. RESULTS: We studied 82 patients, 36 (44%) of whom had CAO. The sensitivity and specificity of the flow-volume curves in detecting CAO were, respectively, 88.9% and 91.3% (quantitative criteria) and 30.6% and 93.5% (qualitative criteria). The most prevalent quantitative criteria in our sample were FEF50%/FIF50% ≥ 1, in 83% of patients, and FEV1/PEF ≥ 8 mL · L(-1) · min(-1), in 36%, both being associated with the type, location, and degree of obstruction (p < 0.05). There was concordance among the reviewers as to the presence of CAO. There is a relationship between the degree of obstruction and dyspnea. CONCLUSIONS: The quantitative criteria should always be calculated for flow-volume curves in order to detect CAO, because of the low sensitivity of the qualitative criteria. Both FEF50%/FIF50% ≥ 1 and FEV1/PEF ≥ 8 mL · L(-1) · min(-1) were associated with the location, type and degree of obstruction.


Assuntos
Obstrução das Vias Respiratórias/diagnóstico , Dispneia/diagnóstico , Obstrução das Vias Respiratórias/complicações , Broncoscopia , Estudos Transversais , Dispneia/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ventilação Pulmonar/fisiologia , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Espirometria
20.
Clin Lung Cancer ; 14(6): 704-12, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23886796

RESUMO

INTRODUCTION: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) holds promise for accurate examination of mediastinal lymph nodes in NSCLC patients. However, it is not always possible to achieve a definitive diagnosis or subtype all cases. We aimed to evaluate the role of EBUS-TBNA combined with quantitative reverse transcription polymerase chain reaction (qRT-PCR) and flow cytometry (FCM) to assess tumor-associated antigens and immune responses to identify metastases and pathological patterns in lymph node aspirates. PATIENTS AND METHODS: EBUS-TBNA samples from patients with NSCLC (n = 33) and nonmalignant diseases (n = 17) were prospectively collected. Cytokeratin 19 (CK-19), carcinoembryonic antigen (CEA), epithelial cell adhesion molecule (EPCAM), sialyl-Lewis(x), CD44, and the immune compartment were analyzed using qRT-PCR and FCM. RESULTS: In the NSCLC patients, the epithelial cell compartment was significantly increased (30.8% vs. 12% CD45⁻ CK-19⁺ cells) and showed brighter CK-19 staining than controls (P = .039) using FCM. Carcinoembryonic antigen was exclusively expressed by the NSCLC epithelial compartment (35% of the cases) and absent in controls. The NSCLC immune compartment showed an increased monocyte population (P = .04), and decreased lymphocyte subpopulations, anticipating a disruption in the distribution of myeloid and lymphoid immune cells. Quantitative reverse transcription polymerase chain reaction showed that CK-19, CEA, and EPCAM transcripts were significantly higher in NSCLC. A positive correlation between the primary tumor lesion size and EPCAM (ρ = 0.476; P = .005), CK-19 (ρ = 0.594; P = .001), and CEA (ρ = 0.394; P = .023) was also found. CONCLUSION: The identification of CK-19, CEA, and EPCAM in EBUS-TBNA samples using FCM and qRT-PCR is feasible and might further aid in the detection of NSCLC lymph node metastasis.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Endossonografia/métodos , Células Epiteliais/patologia , Neoplasias Pulmonares/diagnóstico , Linfonodos/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antígenos de Neoplasias/metabolismo , Biomarcadores Tumorais/metabolismo , Biópsia por Agulha Fina , Brônquios/diagnóstico por imagem , Antígeno Carcinoembrionário/metabolismo , Moléculas de Adesão Celular/metabolismo , Separação Celular , Molécula de Adesão da Célula Epitelial , Feminino , Citometria de Fluxo , Humanos , Queratina-19/metabolismo , Metástase Linfática , Linfócitos/imunologia , Masculino , Pessoa de Meia-Idade , Monócitos/imunologia , Estudos Prospectivos , Reação em Cadeia da Polimerase Via Transcriptase Reversa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA