1.
Phys Med Biol ; 64(7): 075008, 2019 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-30754030

RESUMO

3D breast modelling for 2D and 3D breast x-ray imaging would benefit from the availability of digital and physical phantoms that reproduce accurately the complexity of the breast anatomy. While a number of groups have produced digital phantoms with increasing level of complexity, physical phantoms reproducing that software approach have been scarcely developed. One possibility is offered by 3D printing technology. This implies the assessment of the energy dependent absorption index ß of 3D printing materials for absorption based imaging, as well as the assessment of the refractive index decrement, δ, of the printing material, for phase contrast imaging studies, at the energies of interest for breast imaging. In this work we set-up a procedure and performed a series of measurements (at 30, 45 and 60 keV, at the European Synchrotron Radiation Facility) for assessing the relative value of δ with respect to that of breast tissues, for twelve 3D printing materials. The method included propagation based phase contrast 2D imaging and retrieval of the estimated phase shift map, using the Paganin's algorithm. Breast glandular, adipose and skin tissues were used as reference materials of known ratio δ/ß. A percentage difference Δδ was introduced to assess the suitability of the printing materials as tissue substitutes. The accuracy of the method (about 4%) was assessed based on the properties of PMMA and Nylon, acting as gold standard. Results show that, for the above photon energies, ABS is a good substitute for adipose tissue, Hybrid as a substitute of the glandular tissue and PET-G for simulating the skin. We plan to realize a breast phantom manufactured by fused deposition modelling (FDM) technology using ABS, Hybrid and PET-G as substitutes of the glandular and skin tissue and a second phantom by stereolithography (SLA) technology with the resins Flex, Tough and Black.


Assuntos
Mama/diagnóstico por imagem , Microscopia de Contraste de Fase/métodos , Imagens de Fantasmas , Impressão Tridimensional/instrumentação , Refratometria , Software , Tecido Adiposo/diagnóstico por imagem , Feminino , Humanos , Pele/diagnóstico por imagem
2.
Phys Med Biol ; 61(16): 6243-63, 2016 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-27486086

RESUMO

The major objective is to adopt, apply and test developed in-house algorithms for volumetric breast reconstructions from projection images, obtained in in-line phase-contrast mode. Four angular sets, each consisting of 17 projection images obtained from four physical phantoms, were acquired at beamline ID17, European Synchroton Radiation Facility, Grenoble, France. The tomosynthesis arc was ±32°. The physical phantoms differed in complexity of texture and introduced features of interest. Three of the used phantoms were in-house developed, and made of epoxy resin, polymethyl-methacrylate and paraffin wax, while the fourth phantom was the CIRS BR3D. The projection images had a pixel size of 47 µm × 47 µm. Tomosynthesis images were reconstructed with standard shift-and-add (SAA) and filtered backprojection (FBP) algorithms. It was found that the edge enhancement observed in planar x-ray images is preserved in tomosynthesis images from both phantoms with homogeneous and highly heterogeneous backgrounds. In case of BR3D, it was found that features not visible in the planar case were well outlined in the tomosynthesis slices. In addition, the edge enhancement index calculated for features of interest was found to be much higher in tomosynthesis images reconstructed with FBP than in planar images and tomosynthesis images reconstructed with SAA. The comparison between images reconstructed by the two reconstruction algorithms shows an advantage for the FBP method in terms of better edge enhancement. Phase-contrast breast tomosynthesis realized in in-line mode benefits the detection of suspicious areas in mammography images by adding the edge enhancement effect to the reconstructed slices.


Assuntos
Algoritmos , Mama/anatomia & histologia , Mamografia/instrumentação , Microscopia de Contraste de Fase/métodos , Imagens de Fantasmas , Síncrotrons/instrumentação , Estudos de Viabilidade , Feminino , Humanos , Mamografia/métodos
3.
Comput Biol Med ; 61: 62-74, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25864165

RESUMO

PURPOSE: To present and validate a computer-based simulation platform dedicated for phase contrast x-ray breast imaging research. METHODS: The software platform, developed at the Technical University of Varna on the basis of a previously validated x-ray imaging software simulator, comprises modules for object creation and for x-ray image formation. These modules were updated to take into account the refractive index for phase contrast imaging as well as implementation of the Fresnel-Kirchhoff diffraction theory of the propagating x-ray waves. Projection images are generated in an in-line acquisition geometry. To test and validate the platform, several phantoms differing in their complexity were constructed and imaged at 25 keV and 60 keV at the beamline ID17 of the European Synchrotron Radiation Facility. The software platform was used to design computational phantoms that mimic those used in the experimental study and to generate x-ray images in absorption and phase contrast modes. RESULTS: The visual and quantitative results of the validation process showed an overall good correlation between simulated and experimental images and show the potential of this platform for research in phase contrast x-ray imaging of the breast. The application of the platform is demonstrated in a feasibility study for phase contrast images of complex inhomogeneous and anthropomorphic breast phantoms, compared to x-ray images generated in absorption mode. CONCLUSIONS: The improved visibility of mammographic structures suggests further investigation and optimisation of phase contrast x-ray breast imaging, especially when abnormalities are present. The software platform can be exploited also for educational purposes.


Assuntos
Mama , Mamografia , Modelos Teóricos , Software , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Mamografia/instrumentação , Mamografia/métodos , Imagens de Fantasmas
4.
Comput Methods Programs Biomed ; 107(1): 75-83, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22056810

RESUMO

Digital tomosynthesis is a method of limited angle reconstruction of tomographic images produced at variable heights, on the basis of a set of angular projections taken in an arc around human anatomy. Reconstructed tomograms from unprocessed original projection images, however, are invariably affected by tomographic noise such as blurred images of objects lying outside the plane of interest and superimposed on the focused image of the fulcrum plane. The present work investigates the performance of two approaches for generation of tomograms with a reduced noise: a generalised post-processing method, based on constructing a noise mask from all planes in the reconstructed volume, and its subsequent subtraction from the in-focus plane and a filtered Multiple Projection Algorithm. The comparison between the two algorithms shows that the first method provides reconstructions with very good quality in case of high contrast features, especially for those embedded into a heterogeneous background.


Assuntos
Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Artefatos , Mama/anatomia & histologia , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional/estatística & dados numéricos , Mamografia/estatística & dados numéricos , Modelos Anatômicos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador
5.
Med Eng Phys ; 33(4): 479-89, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21183392

RESUMO

Closed intramedullary nailing is a common technique for treatment of femur and tibia fractures. The most challenging step in this procedure is the precise placement of the lateral screws that stabilize the fragmented bone. The present work concerns the development and the evaluation of a method to accurately identify in the 3D space the axes of the nail hole canals. A limited number of projection images are acquired around the leg with the help of a C-arm. On two of them, the locking hole entries are interactively selected and a rough localization of the hole axes is performed. Perpendicularly to one of them, cone-beam computed tomography (CBCT) reconstructions are produced. The accurate identification and localization of the hole axes are done by an identification of the centers of the nail holes on the tomograms and a further 3D linear regression through principal component analysis (PCA). Various feature-based approaches (RANSAC, least-square fitting, Hough transform) have been compared for best matching the contours and the centers of the holes on the tomograms. The robustness of the suggested method was investigated using simulations. Programming is done in Matlab and C++. Results obtained on synthetic data confirm very good localization accuracy - mean translational error of 0.14 mm (std=0.08 mm) and mean angular error of 0.84° (std=0.35°) at no radiation excess. Successful localization can be further used to guide a surgeon or a robot for correct drilling the bone along the nail openings.


Assuntos
Pinos Ortopédicos , Tomografia Computadorizada de Feixe Cônico , Fixação Intramedular de Fraturas/métodos , Imageamento Tridimensional/métodos , Fluoroscopia
6.
J Med Eng Technol ; 26(6): 247-52, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12490030

RESUMO

The image intensifier (II)-based imaging systems, as radiotherapy simulators or C-arm X-ray units, have also been used for image acquisition in computed tomography. When analogue-to-digital conversion is performed on the output signal of the television camera, the accuracy for low-amplitude video signals, corresponding to X-ray pathways crossing high attenuation structures, is limited. To deal with this lack of accuracy, we investigated the benefits of using a logarithmic amplifier (LOGAMP) inserted between the television camera output and the analogue-to-digital converter (ADC) in the image acquisition chain. Such a device was intended to provide better use of the available ADCs of a given resolution and actually to reduce the quantization noise. Simulated data were used in this study, and cases with and without logarithmic amplifier were compared. Based on the simulation results, we formulate requirements for several signal and acquisition system parameters where the use of such a circuit is recommended.


Assuntos
Conversão Análogo-Digital , Fluoroscopia/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Amplificadores Eletrônicos , Simulação por Computador , Desenho de Equipamento , Fluoroscopia/métodos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processos Estocásticos , Tomografia Computadorizada por Raios X/métodos , Gravação em Vídeo/instrumentação