Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Curr Probl Cardiol ; 49(5): 102485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38428555

RESUMO

AIM: Sudden cardiac arrest is a significant cause of death worldwide. Good quality cardiopulmonary resuscitation increases patients' survival. Manual cardiopulmonary resuscitation is often ineffective as rescuers may experience physical and mental fatigue. Mechanical cardiopulmonary resuscitation devices are designed to address this issue, providing an automated approach for high-quality resuscitation. In the present comprehensive umbrella review we summarize current evidence on mechanical devices. METHODS: We searched systematic reviews on mechanical devices in MEDLINE/PubMed. Effect estimates were obtained from original reports, including 95% confidence intervals and p values, when applicable and available, focusing on return of spontaneous circulation, survival to discharge or 30 days, survival with good neurological outcome, and resuscitation-related injuries. RESULTS: From 21 potentially pertinent publications, we shortlisted 10 reviews, each including between 5 and 22 studies. AutoPulse, LUCAS, and LUCAS-2 were among the investigated devices. Most reviews concluded toward mechanical devices being similar or better than manual resuscitation for return of spontaneous circulation and 30-days survival. Regarding survival with good neurological function, some reviews lacked data, while the remaining ones reported similar results or worse outcomes in patients undergoing mechanical resuscitation. Focusing on resuscitation-related injuries, data were limited or conflicting with one review reporting higher rates of injuries with mechanical devices, and two others suggesting similar outcomes. CONCLUSIONS: Manual and mechanical cardiopulmonary resuscitation appear to be similar in terms of return of spontaneous circulation and short-term survival. Mechanical devices appear to be associated with higher resuscitation-related injuries, while there are conflicting data in terms of survival with good neurological outcomes. A comprehensive and large dedicated randomized trial is urgently needed.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Parada Cardíaca Extra-Hospitalar , Humanos , Massagem Cardíaca/métodos , Reanimação Cardiopulmonar/métodos , Parada Cardíaca/terapia , Morte Súbita Cardíaca
2.
Curr Probl Cardiol ; 49(5): 102491, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38428553

RESUMO

An 84-year-old man with extensive calcified atherosclerosis of the infrarenal abdominal aorta was diagnosed with severe aortic valve stenosis, presenting with dyspnea. To facilitate transfemoral approach during the TAVI procedure, IVUS-guided intravascular lithotripsy was successfully performed using Kissing Shockwave Balloon Technique.


Assuntos
Aorta Abdominal , Estenose da Valva Aórtica , Masculino , Humanos , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico
3.
Curr Probl Cardiol ; 49(5): 102467, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38369208

RESUMO

BACKGROUND: Atrial fibrillation is the most common sustained cardiac arrhythmia in adults and it is associated with a high burden of mortality and morbidity worldwide. Catheter ablation is increasingly used to improve symptoms and prognosis in selected patients. Lower limb venous access with subsequent transseptal approach to the left atrium is the standard procedure for atrial fibrillation catheter ablation. CASE PRESENTATION: We report an unusual case of complex venous anomaly with a left-sided inferior vena cava with hemiazygos continuation to a persistent left superior vena cava draining in an enlarged coronary sinus in a patient with persistent atrial fibrillation scheduled for transcatheter ablation. DISCUSSION: Lower limb venous anomalies may limit a standard transseptal approach to the left atrium thus precluding an effective catheter ablation procedure for atrial fibrillation. Alternative interventions, such as unconventional percutaneous access, thoracoscopic approach and "ablate and pace" procedures, may be necessary in patients with symptomatic atrial fibrillation and complex venous anomalies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Isomerismo , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia , Veia Cava Superior/anormalidades
4.
Int J Cardiol ; 397: 131590, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-37979785

RESUMO

BACKGROUND: Routine thrombus aspiration (TA) does not improve clinical outcomes in patients with ST-segment-elevation myocardial infarction (STEMI), although data from meta-analyses suggest that patients with high thrombus burden may benefit from it. The impact of TA on left ventricular (LV) functional recovery and remodeling after STEMI remains controversial. We aimed to pool data from randomized controlled trials (RCTs) on the impact of TA on LV function and remodeling after primary percutaneous coronary intervention (pPCI). METHODS: PubMed and CENTRAL databases were scanned for eligible studies. Primary outcome measures were: LV ejection fraction (LVEF), LV end diastolic volume (LVEDV), LV end systolic volume (LVESV) and wall motion score index (WMSI). A primary pre-specified subgroup analysis was performed comparing manual TA with mechanical TA. RESULTS: A total of 28 studies enrolling 4990 patients were included. WMSI was lower in TA group than in control (mean difference [MD] -0.11, 95% confidence interval [CI] -0.19 to -0.03). A greater LVEF (MD 1.91, 95% CI 0.76 to 3) and a smaller LVESV (MD -6.19, 95% CI -8.7 to -3.6) were observed in manual TA group compared to control. Meta regressions including patients with left anterior descending artery (LAD) involvement showed an association between TA use and the reduction of both LVEDV and LVESV (z = -2.13, p = 0.03; z = -3.7, p < 0.01) and the improvement in myocardial salvage index (z = 2.04, p = 0.04). CONCLUSION: TA is associated with improved LV function. TA technique, total ischemic time and LAD involvement appears to influence TA benefit on post-infarction LV remodeling.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Trombose , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Remodelação Ventricular , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Função Ventricular Esquerda , Intervenção Coronária Percutânea/efeitos adversos , Trombose/etiologia
6.
Front Cardiovasc Med ; 10: 1088697, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36910536

RESUMO

Background: Phrenic nerve stimulation is a well-recognized complication related to cardiac implantable electronic devices, in particular with left ventricular coronary sinus pacing leads for cardiac resynchronization therapy. Case presentation: We report an unusual case of symptomatic phrenic nerve stimulation due to inadvertent placement of a right ventricular defibrillation lead in coronary sinus posterior branch in a patient with heart failure with reduced ejection fraction with a recently implanted single-chamber cardioverter defibrillator. Discussion: Phrenic nerve stimulation is a relatively common complication of left ventricular pacing. Inadvertent placement of a right ventricular lead in a coronary sinus branch is a rare but possible cause of phrenic nerve stimulation. Careful evaluation of intraprocedural fluoroscopic and electrocardiographic appearance of pacing and defibrillation leads during implantation may prevent inadvertent placement of a right ventricular lead in the coronary sinus.

7.
Minerva Cardiol Angiol ; 71(4): 421-430, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36847435

RESUMO

BACKGROUND: Microvascular obstruction (MVO) is a frequent occurrence after primary percutaneous coronary intervention (pPCI), and is associated with adverse left ventricular remodeling and worse clinical outcome. Distal embolization of thrombotic material is one of the most important underlying mechanisms. The aim of this study was to investigate the relation between the thrombotic volume evaluated by dual quantitative coronary angiography (QCA) prior to stenting and the occurrence of MVO as assessed by cardiac magnetic resonance (CMR). METHODS: Forty-eight patients with ST-segment elevation myocardial infarction (STEMI) undergoing pPCI and receiving CMR within 7 days from admission were included. Pre-stenting residual thrombus volume at the site of the culprit lesion was measured by applying automated edge detection and video-assisted densitometry techniques (i.e., dual-QCA), and patients were categorized into tertiles of thrombus volume. The presence of delayed-enhancement MVO, as well as its extent (MVO mass), were assessed by CMR. RESULTS: Pre-stenting dual-QCA thrombus volume was significantly greater in patients with MVO than in those without (5.85 mm3 [2.05-16.71] vs. 1.88 mm3 [1.03-6.92], P=0.009). Patients in the highest tertile showed greater MVO mass compared to those in the mid and lowest tertiles (113.3 gr [0.0-203.8] vs. 58.5 g [0.00-144.4] vs. 0.0 g [0.0-60.225], respectively; P=0.031). The best cut-off value of dual-QCA thrombus volume for prediction of MVO was 2.07 mm3 (AUC: 0.720). The addition of dual-QCA thrombus volume to the traditional angiographic indices of no-reflow enhanced the prediction of MVO by CMR (R=0.752). CONCLUSIONS: Pre-stenting dual-QCA thrombus volume is associated with the presence and extent of MVO detected by CMR in patients with STEMI. This methodology may aid the identification of patients at higher risk of MVO and guide adoption of preventive strategies.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Trombose , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Angiografia Coronária/métodos , Circulação Coronária , Trombose/etiologia , Intervenção Coronária Percutânea/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA