Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
MethodsX ; 10: 101975, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36636283

RESUMO

Flocculated suspended sediments (flocs) are found in a variety of environments globally, and their transport and behavior bear substantial importance to several industries including fisheries, aquaculture, and shipping. Additionally, the modelling of their behavior is important for estuarine and coastal flood prediction and defence, and the process of flocculation occurs in other unrelated industries such as paper and chemical production. Floc porosity is conventionally assessed using inferential indirect or proxy data approaches. These methods underestimate floc porosity % by c. 30% and cannot measure the micro-scale complexity of these pore spaces and networks, rendering inputs to models sub-optimal. This study introduces a novel 3D porosity and pore space quantification protocol, that produces directly quantified porosity % and pore space data.•3D floc data from micro-CT scanning is segmented volumetrically•This segmented volume is quantified to extract porosity and several pore space parameters from the floc structure.

2.
Water Res ; 222: 118835, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-35914497

RESUMO

Natural sediment flocs are fragile and highly heterogeneous aggregates of biogenic and minerogenic material typically with high porosity and low density. In aquatic environments dominated by fine, cohesive or mixed sediments they can dominate suspended sediment flux. Consequently, monitoring and modelling the behaviour, transport and distribution of flocs is very important for many aquatic industries, maintenance of waterways and conservation and management of aquatic waterbodies. Mathematical models that predict the behaviour of flocs rely on the accurate assessments of the size, shape, density, porosity and fractal dimension of flocs. These inherently 3-dimensional (3D) characteristics are typically derived from 2-dimensional (2D) data, largely due to the challenges associated with sampling, capturing, imaging and quantifying these fragile aggregates. We have developed new volumetric microscopy techniques which can quantify 3D internal and external structures and characteristics of sediment flocs. Here, these techniques were applied to quantify the 3D size (volume), shape and fractal dimension of natural and artificial sediment flocs and compare them to standard 2D approaches. Our study demonstrates that 2D approaches are under-estimating shape complexity and over-estimating the size and mass settling flux of flocs by up to two orders of magnitude, and the discrepancy between 2D and 3D is most marked for natural, organic rich macroflocs. Our study has significant implications for estimations of sediment flux at local to global scales within in aquatic environments. These new data and approaches offer the potential to improve the current parameterisation of sediment transport models and to improve the accuracy of current field-monitoring techniques.


Assuntos
Floculação , Fractais , Sedimentos Geológicos , Sedimentos Geológicos/química , Modelos Teóricos , Porosidade
3.
Rev Sci Instrum ; 91(1): 013901, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012549

RESUMO

The feasibility of a thin-wire torsion stress-strain experiment with nanostrain sensitivity is demonstrated. A gauge length of 50 m was made possible by using The Monument, London, thereby restoring it to its original purpose as a scientific instrument. A wire of 150 µm diameter was studied using the load-unload method, and data were recorded in the elastic regime and through the elastic-plastic transition. Analysis of this preliminary experiment suggested some necessary improvements to the equipment and methods. Progress towards definitive experiments is described together with difficulties still to be overcome.

4.
Proc Math Phys Eng Sci ; 472(2190): 20150890, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27436968

RESUMO

The experimental evidence for the Hall-Petch dependence of strength on the inverse square-root of grain size is reviewed critically. Both the classic data and more recent results are considered. While the data are traditionally fitted to the inverse square-root dependence, they also fit well to many other functions, both power law and non-power law. There have been difficulties, recognized for half-a-century, in the inverse square-root expression. It is now explained as an artefact of faulty data analysis. A Bayesian meta-analysis shows that the data strongly support the simple inverse or lnd/d expressions. Since these expressions derive from underlying theory, they are also more readily explicable. It is concluded that the Hall-Petch effect is not to be explained by the variety of theories found in the literature, but is a manifestation of, or to be underlain by the general size effect observed throughout micromechanics, owing to the inverse relationship between the stress required and the space available for dislocation sources to operate.

5.
Rev Sci Instrum ; 82(9): 093906, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21974599

RESUMO

Simple test equipment has been developed for studying the elastic limit and plastic deformation of thin metal wires and thin foils (down to 10 µm) under torsion, tension, and bending. Using load-unload methods and gauge lengths up to 1 m, plastic strain as low as 10(-6) can be measured accurately.

6.
Eur Cell Mater ; 21: 470-8; discussion 478, 2011 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-21623571

RESUMO

Arthropathy of the distal articular surfaces of the third metacarpal (Mc3) and metatarsal (Mt3) bones in the Thoroughbred racehorse (Tb) is a natural model of repetitive overload arthrosis. We describe a novel pathology that affects the articular calcified cartilage (ACC) and subchondral bone (SCB) and which is associated with hyaline articular cartilage degeneration. Parasagittal slices cut from the palmar quadrant of the distal condyles of the left Mc3/Mt3 of 39 trained Tbs euthanized for welfare reasons were imaged by point projection microradiography, and backscattered electron (BSE) scanning electron microscopy (SEM), light microscopy, and confocal scanning light microscopy. Mechanical properties were studied by nanoindentation. Data on the horses' training and racing career were also collected. Highly mineralised projections were observed extending from cracks in the ACC mineralising front into the hyaline articular cartilage (HAC) up to two-thirds the thickness of the HAC, and were associated with focal HAC surface fibrillation directly overlying their site. Nanoindentation identified this extruded matrix to be stiffer than any other mineralised phase in the specimen by a factor of two. The presence of projections was associated with a higher cartilage Mankin histology score (P<0.02) and increased amounts of gross cartilage loss pathologically on the condyle (P<0.02). Presence of projections was not significantly associated with: total number of racing seasons, age of horse, amount of earnings, number of days in training, total distance galloped in career, or presence of wear lines.


Assuntos
Calcinose/veterinária , Cartilagem Articular/lesões , Cavalos/lesões , Articulação Metatarsofalângica/lesões , Animais , Calcinose/patologia , Carpo Animal/lesões , Carpo Animal/patologia , Cartilagem Articular/patologia , Transtornos Traumáticos Cumulativos/complicações , Transtornos Traumáticos Cumulativos/veterinária , Humanos , Masculino , Articulação Metatarsofalângica/patologia , Osteoartrite/etiologia , Osteoartrite/veterinária , Tarso Animal/lesões , Tarso Animal/patologia
7.
Eur Cell Mater ; 19: 242-51, 2010 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-20524176

RESUMO

Condylar fracture of the third metacarpal bone (Mc3) is the commonest cause of racetrack fatality in Thoroughbred horses. Linear defects involving hyaline articular cartilage, articular calcified cartilage (ACC) and subchondral bone (SCB) have been associated with the fracture initiation site, which lies in the sagittal grooves of the Mc3 condyle. We discovered areas of thickened and abnormally-mineralised ACC in the sagittal grooves of several normal 18-month-old horses, at the same site that linear defects and condylar fracture occur in older Thoroughbreds and questioned whether this tissue had altered mechanical properties. We embedded bone slices in PMMA, prepared flat surfaces normal to the articular surface and studied ACC and SCB using combined quantitative backscattered electron scanning electron microscopy (qBSE) and nanoindentation testing: this allowed correlation of mineralisation density and tissue stiffness (E) at the micron scale. We studied both normal and affected grooves, and also normal condylar regions. Large arrays of indentations could be visualised as 2-dimensional maps of E with a limit to resolution of indentation spacing, which is much larger than qBSE pixel spacing. ACC was more highly mineralised but less stiff in early linear defects than in control regions, while subchondral bone was more highly mineralised and stiffer in specimens with early linear defects than those without. Thus both ACC and SCB mineralisation may be abnormal in a class of early linear defect in 18-month-old Thoroughbred horses, and this may possibly contribute to later fracture of the Mc3 condyle.


Assuntos
Calcinose/patologia , Cartilagem Articular/patologia , Fraturas Ósseas/etiologia , Cavalos , Ossos Metacarpais/patologia , Animais , Fenômenos Biomecânicos , Densidade Óssea , Calcinose/veterinária , Fraturas Ósseas/patologia , Fraturas Ósseas/veterinária , Microscopia Eletrônica de Varredura
8.
Phys Rev Lett ; 103(15): 155501, 2009 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-19905649

RESUMO

A theory for the size effect in the strength of wires under torsion is reported and compared with data from thin copper wires. Critical thickness theory is solved rigorously and used to validate a useful approximation which is combined with slip-distance theory modified for a finite structure size. Experimental data with high accuracy around and above the elastic limit show excellent agreement with the theory. The results strongly imply that the physical principle is the constraint that size, whether grain size or structure size, puts on allowed dislocation curvature.

9.
Eur Cell Mater ; 16: 40-6; discussion 46, 2008 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-18800313

RESUMO

Impact exercise has a profound effect in increasing volumetric density of epiphyseal bone, as clearly shown in 2 year old thoroughbred racehorses from which we derived the tissue studied in the present investigation. Here, we asked the question whether the fabric-level properties of the mineralised tissues immediately below hyaline articular cartilage which transmit the extra loads are themselves altered in consequence. We therefore studied the nanoindentation elastic modulus and its relationship to the concentration of mineral determined by quantitative backscattered electron imaging in the heavily loaded palmar medial and lateral condyles of the distal third metacarpal bone (Mc3) of 4 untrained and 4 trained 2-year old Thoroughbred racehorses. We found no difference between trained and untrained horses in either subchondral bone or calcified cartilage in the mean stiffness or mineral content or their correlation. Thus neither articular calcified cartilage nor the immediately adjacent subchondral bone were affected by exercise, even though they transmitted the higher load associated with athletic training through to the deeper bone, which itself responded floridly to exercise. Under the circumstances of this experiment and at least in the very small regions studied, therefore, the structure of these two tissues was apparently optimised to function.


Assuntos
Calcificação Fisiológica/fisiologia , Cavalos/fisiologia , Ossos Metacarpais/fisiologia , Condicionamento Físico Animal/fisiologia , Amplitude de Movimento Articular/fisiologia , Animais , Fenômenos Biomecânicos , Cartilagem Articular/fisiologia , Elasticidade , Feminino , Suporte de Carga
10.
Biomaterials ; 22(11): 1401-6, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11336314

RESUMO

There is a requirement for a dental cement with properties comparable or superior to conventional glass ionomer cements (GICs) but with the command set properties of the resin-modified GICs. The objective of this work was to show that the application of ultrasound to conventional Fuji IX commercial glass ionomer cement imparts a command set, whilst improving the short-term surface mechanical properties. Nano-indentation techniques were employed to highlight the improvements in hardness and creep resistance imparted to the cement through the application of ultrasound. The instant set imparted by the application of ultrasound provides improved surface hardness and creep, particularly within the first 24 h after setting. The surface hardness of the chemically cured Fuji IX (176 M Pa) increased by an order of magnitude when set ultrasonically (2620 M Pa), whilst creep reduced to a negligible amount. Rapid setting allows for shorter chair time and an improved clinical technique, making restorations more convenient for both the patient and clinician.


Assuntos
Cimentos Dentários , Vidro , Teste de Materiais , Ultrassom
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA