Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Medicine (Baltimore) ; 98(33): e16606, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31415352

RESUMO

OBJECTIVE: The aim of this study was to determine optimal window settings for conventional polyenergetic and virtual monoenergetic images derived from computed tomography pulmonary angiogram (CTPA) examinations of a novel dual-layer spectral detector computed tomography system (DLCT). METHODS: Monoenergetic (40 keV) and polyenergetic images of 50 CTPA examinations were calculated and the best individual window width and level (W/L) values were manually assessed. Optimized values were obtained afterwards based on regression analysis. Diameters of standardized pulmonary artery segments and subjective image quality parameters were evaluated and compared. RESULTS: Attenuation and contrast-to-noise values were higher in monoenergetic than in polyenergetic images (P≤.001). Averaged best individual W/L for polyenergetic and monoenergetic were 1020/170 and 2070/480 HU, respectively.All adjusted W/L-settings varied significantly compared to standard settings (700/100 HU) and obtained higher subjective image quality scores. A systematic overestimation of artery diameters for standard window settings in monoenergetic images was observed. CONCLUSIONS: Appropriate W/L-settings are required to assess polyenergetic and monoenergetic CTPA images of a novel DLCT. W/L-settings of 1020/170 HU and 2070/480 HU were found to be the best averaged values for polyenergetic and monoenergetic CTPA images, respectively.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Humanos , Pneumologia/métodos , Razão Sinal-Ruído
2.
Clin Gastroenterol Hepatol ; 17(13): 2793-2799.e1, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30940552

RESUMO

BACKGROUND & AIMS: We studied the effects of diameter of covered, self-expandable, nitinol stents on survival times of patients with a transjugular intrahepatic portosystemic shunt (TIPS). METHODS: We collected data from 185 patients (median age, 55 y; 30% female) who received a covered nitinol stent, from February 2006 through September 2010, using the online multicenter German TIPS registry. TIPS were given to 107 patients for refractory ascites and to 78 patients for variceal bleeding. Patients at risk of hepatic encephalopathy (owing to advanced age, prior episodes) or liver failure (bilirubin level, >3 mg/dL), and bleeding patients receiving variceal embolization at TIPS, received 8-mm stents (n = 53). The remaining patients received 10-mm stents (n = 132). Eighty-one of the 10-mm stents were underdilated using 8-mm dilation balloons. Clinical and biochemical data were collected after TIPS placement at 1 month, 3 months, 6 months, 9 months, 1 year, and thereafter every 3 to 6 months. Groups were compared using propensity score analysis. RESULTS: Patients who received 8-mm stents survived significantly longer (34 ± 26 mo) than patients who received 10-mm stents (18 ± 19 mo), regardless of whether they were fully dilated or underdilated. When we compared 10-mm stents with or without underdilation, we found that a significantly higher proportion of patients who received underdilated stents survived for 1 month after TIPS placement (95% vs 84%; P = .03), but not for 3 months (P = .10). In multivariate analysis, 1-year mortality correlated with full dilation of the stent to 10 mm (hazard ratio [HR], 2.0; 95% CI, 1.1-3.5) and with serum creatinine concentration at baseline (HR, 1.5; 95% CI, 1.0-1.7). Five-year mortality was associated with use of the 10-mm stents (HR, 1.8; 95% CI, 1.4-2.7) and baseline concentration of creatinine (HR, 1.3; 95% CI, 1.1-1.6). CONCLUSIONS: A smaller stent (nominal diameter of 8 mm, but not underdilation of a 10-mm stent) is associated with a prolonged survival compared with 10-mm stents, independent of liver-specific prognostic criteria.


Assuntos
Ascite/fisiopatologia , Varizes Esofágicas e Gástricas/fisiopatologia , Hemorragia Gastrointestinal/fisiopatologia , Hipertensão Portal/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/instrumentação , Stents Metálicos Autoexpansíveis , Adulto , Idoso , Idoso de 80 Anos ou mais , Ascite/etiologia , Varizes Esofágicas e Gástricas/etiologia , Feminino , Hemorragia Gastrointestinal/etiologia , Humanos , Hipertensão Portal/complicações , Hipertensão Portal/fisiopatologia , Masculino , Pessoa de Meia-Idade , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Sistema de Registros
3.
J Comput Assist Tomogr ; 42(3): 350-356, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29369944

RESUMO

OBJECTIVE: We aimed to determine optimal window settings for conventional polyenergetic (PolyE) and virtual monoenergetic images (MonoE) derived from abdominal portal venous phase computed tomography (CT) examinations on a novel dual-layer spectral-detector CT (SDCT). METHODS: From 50 patients, SDCT data sets MonoE at 40 kiloelectron volt as well as PolyE were reconstructed and best individual window width and level values manually were assessed separately for evaluation of abdominal arteries as well as for liver lesions. Via regression analysis, optimized individual values were mathematically calculated. Subjective image quality parameters, vessel, and liver lesion diameters were measured to determine influences of different W/L settings. RESULTS: Attenuation and contrast-to-noise values were significantly higher in MonoE compared with PolyE. Compared with standard settings, almost all adjusted W/L settings varied significantly and yielded higher subjective scoring. No differences were found between manually adjusted and mathematically calculated W/L settings. CONCLUSIONS: PolyE and MonoE from abdominal portal venous phase SDCT examinations require appropriate W/L settings depending on reconstruction technique and assessment focus.


Assuntos
Abdome/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Abdome/irrigação sanguínea , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Tomógrafos Computadorizados
4.
Eur J Radiol ; 99: 28-33, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29362148

RESUMO

OBJECTIVES: To investigate the utilization of virtual mono-energetic images (MonoE) at low kiloelectron volt (keV) levels derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans using arterial phase imaging as an internal reference standard. MATERIALS AND METHODS: A total of 50 patients who received arterial and venous phase imaging of the abdomen on a SDCT system were included in this study. Absolute attenuation, noise, signal- and contrast to noise ratios (SNR; CNR) as well as arterial diameters in defined landmarks were assessed. In arterial phase, conventional reconstructions (CRART) as well as MonoEART at 40keV and in venous phase, conventional reconstructions (CRVEN) as well as MonoEVEN at 70 and 40keV were investigated and intra-individual comparisons were performed. If an artery stenosis (10 patients) was present, the degree of stenosis was assessed according to the system of the North American Symptomatic Carotid Endarterectomy Trial (NASCET). RESULTS: MonoE 40keV yielded significantly higher attenuation values (in arterial as well as in venous phase) compared to CRART (p<0.001) while noise levels were substantially low. This resulted in markedly superior SNR and CNR in large vessel compared to CRART. Luminal diameters were significantly smaller in MonoE 40keV in both contrast phases compared to CRART (p<0.001), whereas no significant differences were found between both MonoE reconstructions (p≥0.92). The degree of vessel stenosis was significantly higher in MonoE 40keV of both contrast phases compared to CRART (p≥0.02). CONCLUSION: MonoE at low keV of venous contrast phase scans derived from a novel SDCT are suitable for the assessment of arteries in the abdomen and subsequent stenosis assessment. However, MonoE at 40keV constantly showed significant smaller luminal diameters than the corresponding conventional reconstructions (including the reference standard). This is possibly due to an improved differentiation of the vessel lumen from the wall and raises the question, which imaging technique should be used as an appropriate reference standard for vascular SDCT imaging studies.


Assuntos
Abdome/irrigação sanguínea , Artérias/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/mortalidade , Idoso , Pontos de Referência Anatômicos , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/patologia , Artérias/patologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Estudos Retrospectivos , Razão Sinal-Ruído , Veias/diagnóstico por imagem
5.
Abdom Radiol (NY) ; 43(3): 742-750, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28677003

RESUMO

PURPOSE: We aimed to determine optimal window settings for poly-energetic (PolyE) and virtual mono-energetic images (MonoE) derived from abdominal angiographic studies on a novel dual-layer spectral detector CT (SDCT) system. METHODS: From 50 patients, SDCT datasets PolyE and MonoE at 70 and 40 keV levels were reconstructed and best individual window width and level (BI-W/L) manually assessed. Through regression analysis, the so-called optimized individual (OI-W/L) values were obtained. Subjective image quality parameters and vessel diameters were measured to determine influences of different W/L settings. RESULTS: Image noise was lower and attenuation and contrast-to-noise ratio were higher in MonoE compared to PolyE (all p ≤ 0.002). Mean BI-W/L values for PolyE, 70, and 40 keV were 637/284, 647/291, and 1568/691, respectively. Mean OI-W/L values were 631/276, 628/286, and 1516/667, respectively. Compared to standard settings, all adjusted W/L settings varied significantly and yielded higher subjective scoring. No between-group differences were found between manually adjusted and mathematically calculated W/L settings. CONCLUSION: PolyE and MonoE from abdominal angiographic SDCT studies require appropriate W/L settings especially at low energy reconstruction levels. Individual adjustment reaches the best image quality but is time consuming. From our data, predefined W/L settings of 640/280 (PolyE/MonoE 70 keV) and 1570/690 (MonoE 40 keV) as a non-individualized starting point for abdominal angiographic studies from the novel SDCT system are suggested.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Feminino , Humanos , Masculino , Estudos Retrospectivos
6.
PLoS One ; 12(8): e0183759, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28837641

RESUMO

OBJECTIVES: To quantitatively and qualitatively assess abdominal arterial and venous phase contrast-enhanced spectral detector computed tomography (SDCT) virtual mono-energetic (MonoE) datasets in comparison to conventional CT reconstructions provided by the same system. MATERIALS AND METHODS: Conventional and MonoE images at 40-120 kilo-electron volt (keV) levels with a 10 keV increment as well as 160 and 200 keV were reconstructed in abdominal SDCT datasets of 55 patients. Attenuation, image noise, and contrast- / signal-to-noise ratios (CNR, SNR) of vessels and solid organs were compared between MonoE and conventional reconstructions. Two readers assessed contrast conditions, detail visualization, overall image quality and subjective image noise with both, fixed and adjustable window settings. RESULTS: Attenuation, CNR and SNR of vessels and solid organs showed a stepwise increase from high to low keV reconstructions in both contrast phases while image noise stayed stable at low keV MonoE reconstruction levels. Highest levels were found at 40 keV MonoE reconstruction (p<0.001), respectively. Solid abdominal organs showed a stepwise decrease from low to high energy levels in regard to attenuation, CNR and SNR with significantly higher values at 40 and 50 keV, compared to conventional images. The 70 keV MonoE was comparable to conventional poly-energetic reconstruction (p≥0.99). Subjective analysis displayed best image quality for the 70 keV MonoE reconstruction level in both phases at fixed standard window presets and at 40 keV if window settings could be adjusted. CONCLUSION: SDCT derived low keV MonoE showed markedly increased CNR and SNR values due to constantly low image noise values over the whole energy spectrum from 40 to 200 keV.


Assuntos
Abdome/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Razão Sinal-Ruído
7.
Eur J Radiol ; 93: 52-58, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28668431

RESUMO

OBJECTIVES: To evaluate image quality parameters of virtual mono-energetic (MonoE) and conventional (CR) imaging derived from a dual-layer spectral detector CT (DLCT) in oncological follow-up venous phase imaging of the chest and comparison with conventional multi-detector CT (CRMDCT) imaging. MATERIALS AND METHODS: A total of 55 patients who had oncologic staging with conventional CT and DLCT of the chest in venous phase were included in this study. Established image quality parameters were derived from all datasets in defined thoracic landmarks. Attenuation, image noise, and signal-/contrast- to noise ratios (SNR, CNR) were compared between CRDLCT and MonoE as well as CRMDCT imaging. Two readers performed subjective image analysis. RESULTS: CRMDCT showed significant lower attenuation values compared to CRDLCT and MonoE at 40-70keV (p≤0.05). Moreover, MonoE at 40-70keV revealed significantly higher attenuations values compared to CRDLCT (p<0.001). Noise was statistically lower in CRMDCT compared with CRDLCT and MonoE at 40keV (11.4±2.3 HU vs. 12.0±3.1 HU vs. 11.7±5.2 HU; p<0.001). In contrast, all MonoE levels showed significantly lower noise levels compared to CRDLCT (p<0.001). SNR was not significantly different between CRMDCT and CRDLCT (13.5±3.7 vs. 14.4±5.3; p>0.99). SNR values were significantly increased for MonoE at 40-80keV compared to CRMDCT and CRDLCT (p<0.001). CRDLCT and MonoE (40-70keV) from DLCT revealed significantly higher CNR values than CRMDCT (p<0.001). In subjective analysis, MonoE at 40keV surpassed all other image reconstructions except for noise in MonoE at 70 keV. CONCLUSION: In dual-layer spectral detector CT, MonoE at low keV showed superior image quality compared to conventional images derived from the same system and may therefore be added to clinical routine imaging protocols. Whether MonoE reconstructions yield additional diagnostic information is still unknown.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Radiografia Torácica/métodos , Neoplasias Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA