Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 8306, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594338

RESUMO

The creep response of the 17-4PH martensitic age-hardening steel in H1150 state was investigated at 427 and 482 °C. Hardness measurements of the heads of the creep samples demonstrated that the material underwent additional age hardening during the high-temperature exposure. Microstructural investigations confirmed that the additional precipitation of carbides and the G-phase occurred at the lowest temperature. A set of constitutive equations previously developed to describe the creep response of particle-strengthened alloys was successfully used to obtain a comprehensive description of the experimental data. The value of the particle strengthening term was obtained from the hardness measurements and corresponded to the Orowan stress. The model accurately described the observed minimum creep rate dependence on the applied stress and explained the occurrence of lower values of the minimum strain rate observed during variable-load experiments.

2.
Nanotechnology ; 28(19): 194001, 2017 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-28301333

RESUMO

An advantageous micromechanical technique to deposit large area graphene nanoplatelet (GNP) thin films on a low-density polyethylene substrate is proposed. This method is based on the application of shear-stress and friction forces to a graphite platelets/ethanol paste on the surface of a polymeric substrate; it allows us to obtain a continuous film of superimposed nanoplatelets mainly made of 13-30 graphene layers. X-ray diffraction (XRD), atomic force and transmission electron microscopy (TEM) measurements support the occurrence of a partial exfoliation of the graphite platelets due to shear-stress and friction forces applied during film formation. Scanning electron microscopy (SEM) observations point out that the surface of the polymer is uniformly coated by the overlap of GNPs, and TEM analysis reveals the tendency of the nanoplatelets to align parallel to the interface plane. It has been found that the deposited samples, under white light illumination, exhibit a negative photoconductivity and a linear photoresponse as a function of the applied voltage and the optical power density in the -120 ÷ 120 mV and 20.9 ÷ 286.2 mW cm-2 ranges, respectively.

3.
Micron ; 43(2-3): 215-22, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21890366

RESUMO

Nanoindentation has become a common technique for measuring the hardness and elastic-plastic properties of materials, including coatings and thin films. In recent years, different nanoindenter instruments have been commercialised and used for this purpose. Each instrument is equipped with its own analysis software for the derivation of the hardness and reduced Young's modulus from the raw data. These data are mostly analysed through the Oliver and Pharr method. In all cases, the calibration of compliance and area function is mandatory. The present work illustrates and describes a calibration procedure and an approach to raw data analysis carried out for six different nanoindentation instruments through several round-robin experiments. Three different indenters were used, Berkovich, cube corner, spherical, and three standardised reference samples were chosen, hard fused quartz, soft polycarbonate, and sapphire. It was clearly shown that the use of these common procedures consistently limited the hardness and reduced the Young's modulus data spread compared to the same measurements performed using instrument-specific procedures. The following recommendations for nanoindentation calibration must be followed: (a) use only sharp indenters, (b) set an upper cut-off value for the penetration depth below which measurements must be considered unreliable, (c) perform nanoindentation measurements with limited thermal drift, (d) ensure that the load-displacement curves are as smooth as possible, (e) perform stiffness measurements specific to each instrument/indenter couple, (f) use Fq and Sa as calibration reference samples for stiffness and area function determination, (g) use a function, rather than a single value, for the stiffness and (h) adopt a unique protocol and software for raw data analysis in order to limit the data spread related to the instruments (i.e. the level of drift or noise, defects of a given probe) and to make the H and E(r) data intercomparable.

4.
Micron ; 36(5): 401-14, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15908224

RESUMO

Microstructural evolution due to equal-channel angular-pressing (ECAP) with increasingly severe deformation was investigated in a commercially pure 1200 aluminum alloy. A true strain of eight produced sub-micrometer scale grains and very fine subgrains in the grain interior. The deformation process was documented and described using field-emission (FEG) gun scanning and transmission electron microscopy techniques. After eight ECAP passes, the high-angle grain boundaries accounted for approximately 70% of all boundaries. The fine spacing resolution of FEG scanning electron microscopy allowed detailed grain and subgrain statistical evaluation in the deformed microstructure; transmission electron microscopic inspection afforded appreciation of the role of very low-angle misorientation boundaries in the microstructure-refining process. ECAP results were compared with those produced by cold rolling. The material's texture evolved in a decreasing trend of Cube {001}100 intensities in favor of Cube rotated toward the normal-to-pressing direction {001}120, while Goss {110}001 and {111}110, {111}112 directions slightly increased with strain.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA