Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 10(10)2021 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-34064752

RESUMO

The aim of this study was to evaluate the safety and efficacy of the intra-articular administration of autologous purified adipose tissue to treat knee osteoarthritis (OA) following arthroscopy. Thirty patients with radiological evidence of knee OA were recruited. A small liposuction and arthroscopic lavage and debridement were performed in the same surgical time. The harvested fat was processed intraoperatively with Lipocell (Tiss'You, RSM) to purify the adipose tissue injected into the knee. Clinical evaluations were performed with VAS, Womac, and Lequesne questionnaires before treatment and after 1, 3, 6, and 12 months of follow-up. Pain, measured with VAS, significantly decreased, showing a reduction of 53% after 1 month and 83% after a year. Functional recovery, measured with Womac, showed an improvement of 47% after 1 month post-treatment and 84% after 1 year. No adverse effects have been observed. The intra-articular administration of purified adipose tissue associated with arthroscopic lavage and debridement is a safe and significantly effective strategy in improving the symptoms of knee osteoarthritis in up to 1 year of follow-up.

2.
Injury ; 48 Suppl 3: S34-S38, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29025607

RESUMO

INTRODUCTION: Open reduction and internal fixation (ORIF) with plate and screws represents the recommended treatment for unstable intra-articular distal radius fractures. Although significant progresses in surgical technique have been made, anatomical reconstruction of radio-carpal articular surface still represent a difficult task, especially in multifragmentary fractures. Available PEEK reinforced-carbon fiber composite radiolucent devices allow both an easier and more careful assessment of intra-operative reduction of the articular surface of distal radius and prompt correction of any residual step deformity. MATERIALS AND METHODS: We retrospectively reviewed clinical and radiological multicentre results of 71 consecutive AO B and C fracture pattern of distal radius treated using the same PEEK reinforced-carbon fiber composite radiolucent plate. RESULTS: Three patients lost at final follow up and 4 cases with incomplete radiological documentations were excluded from the study. 64 patients (38 females, 26 males) were available and formed the basis of this report. Fracture types included 9 patients with 23-B, 13 patients 23-B2,15 patients with 23-B3,10 patients with 23-C1, 7 patients with 23-C2 and 10 patients with 23-C3. Mean Modified Mayo wrist Score was on average 38.11 (SD 10.1; range 24-75, 95%CI 34.7-41.4), 67.22 (SD 9.6, range 50-90, 95%CI 64-70.4), 90.54 (SD 6.3, range 75-100, 95%CI 88.4-92.6) at one, two and twelve months of follow-up, respectively. A statistically significant difference was found between mean scores at different follow-up periods (p = 0.001). We noted 1 case of distal screw fixation aseptic loosening at 5 months post surgical intervention. CONCLUSIONS: PEEK reinforced-carbon fiber composite radiolucent plate represents a useful device for treatment of complex distal radius fractures in the adult population. It possesses unique biomechanical properties and allows for an easier anatomical reduction during surgical intervention.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Consolidação da Fratura/fisiologia , Radiografia , Fraturas do Rádio/cirurgia , Articulação do Punho/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Benzofenonas , Parafusos Ósseos , Carbono , Fibra de Carbono , Feminino , Seguimentos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Humanos , Cetonas , Masculino , Pessoa de Meia-Idade , Polietilenoglicóis , Polímeros , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Estudos Retrospectivos , Resultado do Tratamento , Articulação do Punho/fisiopatologia , Adulto Jovem
3.
J Back Musculoskelet Rehabil ; 30(2): 195-202, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27392846

RESUMO

BACKGROUND: The aim of the surgical treatment in proximal humeral fractures is to maintain bone alignment facilitating an early shoulder mobilization. This can be obtained with the use of an endomedullary nail with specific characteristics: a proximal angular multiplanar stability and the possibility to place proximal screws in the calcar region. The objective of this randomized controlled trial is to investigate the effects of an early rehabilitation program in 3-part proximal humeral fractures treated with endomedullary nailing. MATERIALS AND METHODS: 126 patients treated with the Diphos Proximal Humeral Nail (PHN), followed with an Intensive Rehabilitation Program (IRP) started in the second postoperative day, were compared to 62 patients with a Standard Rehabilitation Program (SRP) where shoulder mobilization started after 3 weeks. The age of patients was under 65 years. Main Outcome measures were improvement of shoulder function based on Constant Score and quality of life on DASH questionnaire at 1, 3, 6 and 12 months after surgery. Safety outcome was no loss of radiological reduction at any follow-up control. RESULTS: A difference considered statistically significant (95% confidence interval) was demonstrated by Constant scores at 3 and 6 months and by DASH questionnaire scores at 1 month after surgery between IRP and SRP groups, however without loss of radiological reduction and maintaining the full fracture healing at the same mean period of 1,8 ± 0,7 months. DISCUSSION: This experience allows to highlight essential features of this new kind of endomedullary humeral nail, by its mechanical properties, in proximal humeral fractures in order to permit an early rehabilitation without creating displaced or consolidation delay. LEVEL OF EVIDENCE: III, randomized clinical-case-control study.


Assuntos
Pinos Ortopédicos , Fixação Interna de Fraturas/métodos , Modalidades de Fisioterapia , Fraturas do Ombro/terapia , Idoso , Estudos de Casos e Controles , Feminino , Fixação Interna de Fraturas/efeitos adversos , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Radiografia , Fraturas do Ombro/reabilitação , Fraturas do Ombro/cirurgia , Resultado do Tratamento
4.
Injury ; 47 Suppl 4: S64-S70, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27507546

RESUMO

INTRODUCTION: Proximal humeral fractures with a spiral line of fracture extending from the humeral head to the diaphyseal region are increasing. Treatment for these fractures is comparable to that for shaft fractures. The purpose of this study was to evaluate the use of a new "Long" humeral nail for this type of lesion and identify the best distal locking. MATERIALS AND METHODS: Forty-three patients treated with a Long Diphos Nail® were selected for this study: main exclusion criteria were poor cognitive and responsive ability to physical therapy, four-part fracture requiring humeral head replacement, an isolated greater or lesser tubercle fracture and a head-splitting fracture. All patients were divided into two groups according to the distal locking (single or double) and clinically evaluated at 1, 3, 6 and 12 months after surgery. The following parameters were evaluated: fracture healing on radiographic images every month; level of pain with Visual Analogue Scale (VAS); recovery of shoulder function or ability to resume normal daily activities according to the Constant Scoring System (CSS); patient satisfaction; and complications, like fracture consolidation defect or delay. A statistical analysis was performed. RESULTS: Improvements in pain, satisfaction and shoulder functional recovery were recorded. Patients reached fracture healing in two to six months. The mean healing time was better for double distal locking (p=0.04).There was a clinically greater difference (p=0.006) between the groups for the mean Constant score at 3 months follow-up, with better results for the double distal locking group. Complications were: one patient with a consolidation delay with a single distal locking screw breakage; it was necessary to remove the nail and perform a second treatment. CONCLUSIONS: The results of the study indicate the efficacy of Long Diphos Nail® in the treatment of fractures with a line of fracture extending to the proximal diaphyseal region. The features of a multiplane stabilisation above the fracture and a distal double locking may represent the key for a good fixation for 11-A2, A3 or B2 fractures with a long spiral line. A double distal locking reduces fracture micro-instability and so patients recover function and strength quicker because of less pain at the fracture site. STUDY DESIGN: retrospective, cohort of cases. LEVEL OF EVIDENCE: IV.


Assuntos
Pinos Ortopédicos , Fixação Intramedular de Fraturas , Complicações Pós-Operatórias/diagnóstico por imagem , Radiografia , Fraturas do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas , Feminino , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Satisfação do Paciente , Modalidades de Fisioterapia , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/fisiopatologia , Resultado do Tratamento
5.
Arthroplast Today ; 1(3): 81-84, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28326377

RESUMO

There is still debate over the limits of age and bone stock quality of patients on whom to use an un-cemented straight stem coated with hydroxyapatite (HA). We studied a group of 244 patients with a displaced intracapsular fracture of the femoral neck who underwent cementless hemiarthroplasty or total hip arthroplasty. 143 patients were reviewed at the two-year follow up. A fully HA-coated stem for intracapsular hip fracture results in a satisfactory return to pre-injury mobility and a low complications rate. The advantage reported in the literature of a low mortality rate with use of an un-cemented implant in elderly patients was shown to be greater still on finding an immediate primary stability and rapid osteointegration of the implant.

6.
Clin Appl Thromb Hemost ; 21(2): 115-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25125051

RESUMO

Despite current guidelines recommendations about anticoagulant prophylaxis, many studies have shown an high venous thromboembolism (VTE) incidence in patients undergoing total hip and knee arthroplasty. A number of anticoagulants are currently available, but they have some limitations that affect their applicability and consequently their effectiveness. Several new oral anticoagulants (NOACs) have been developed in an attempt to overcome these limitations. Apixaban is a NOAC that selectively inhibits the coagulation factor Xa; it is approved for the prevention of VTE after total hip replacement and total knee replacement surgery. This review examines the results of main trials designed to test efficacy and safety of apixaban in major elective orthopedic surgery.


Assuntos
Artroplastia de Quadril , Enoxaparina/uso terapêutico , Inibidores do Fator Xa/uso terapêutico , Pirazóis/uso terapêutico , Piridonas/uso terapêutico , Tromboembolia Venosa/prevenção & controle , Administração Oral , Enoxaparina/efeitos adversos , Inibidores do Fator Xa/efeitos adversos , Humanos , Pirazóis/efeitos adversos , Piridonas/efeitos adversos
7.
Injury ; 45 Suppl 6: S36-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25457316

RESUMO

The radiolucent plate has many advantageous properties in the treatment of complex ankle fractures, particularly trimalleolar fractures. Surgeons may sometimes have difficulty observing the posterior malleolus after synthesis of lateral malleolus with a traditional plate because common materials of conventional plates are not radiolucent. In this study, the authors highlight the importance of the radiolucent property in the treatment of ankle fractures and describe their preliminary experience with a carbon fibre-reinforced polyetheretherketone distal fibula plate, with good results at 4 months' follow-up and no signs of tissue inflammatory reaction.


Assuntos
Fraturas do Tornozelo/cirurgia , Materiais Biocompatíveis , Placas Ósseas , Fixação Interna de Fraturas/métodos , Cetonas , Polietilenoglicóis , Adulto , Idoso , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/fisiopatologia , Benzofenonas , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Radiografia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA