Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Med Sci Sports Exerc ; 46(8): 1489-97, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24389514

RESUMO

UNLABELLED: Blood flow-restricted resistance exercise improves muscle strength; however, the cardiovascular response is not well understood. PURPOSE: This investigation measured local vascular responses, tissue oxygen saturation (StO2), and cardiovascular responses during supine unilateral leg press and heel raise exercise in four conditions: high load with no occlusion cuff, low load with no occlusion cuff, and low load with occlusion cuff pressure set at 1.3 times resting diastolic blood pressure (BFRDBP) or at 1.3 times resting systolic blood pressure (BFRSBP). METHODS: Subjects (N = 13) (men/women, 5/8, 31.8 ± 12.5 yr, 68.3 ± 12.1 kg, mean ± SD) performed three sets of leg press and heel raise to fatigue with 90-s rest. Artery diameter, velocity time integral, and stroke volume were measured using two-dimensional and Doppler ultrasound at rest and immediately after exercise. HR was monitored using a three-lead ECG. Finger blood pressure was acquired by photoplethysmography. Vastus lateralis StO2 was measured using near-infrared spectroscopy. A repeated-measures ANOVA was used to analyze exercise work and StO2. Multilevel modeling was used to evaluate the effect of exercise condition on vascular and cardiovascular variables. Statistical significance was set a priori at P < 0.05. RESULTS: Artery diameter did not change from baseline during any of the exercise conditions. Blood flow increased after exercise in each condition except BFRSBP. StO2 decreased during exercise and recovered to baseline levels during rest only in low load with no occlusion cuff and high load with no occlusion cuff. HR, stroke volume, and cardiac output (Q˙) responses to exercise were blunted in blood flow-restricted exercise. Blood pressure was elevated during rest intervals in blood flow-restricted exercise. CONCLUSIONS: Our results demonstrate that cuff pressure alters the hemodynamic responses to resistance exercise. These findings warrant further evaluations in individuals presenting cardiovascular risk factors.


Assuntos
Hemodinâmica/fisiologia , Treinamento Resistido/métodos , Adulto , Pressão Sanguínea , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiologia , Frequência Cardíaca , Calcanhar/fisiologia , Humanos , Perna (Membro)/fisiologia , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiologia , Fluxo Sanguíneo Regional , Ultrassonografia , Suporte de Carga
2.
Aviat Space Environ Med ; 83(10): 995-1000, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23066623

RESUMO

INTRODUCTION: With missions planned to travel greater distances from Earth at ranges that make real-time two-way communication impractical, astronauts will be required to perform autonomous medical diagnostic procedures during future exploration missions. Virtual guidance is a form of just-in-time training developed to allow novice ultrasound operators to acquire diagnostically-adequate images of clinically relevant anatomical structures using a prerecorded audio/visual tutorial viewed in real-time. METHODS: Individuals without previous experience in ultrasound were recruited to perform carotid artery (N = 10) and ophthalmic (N = 9) ultrasound examinations using virtual guidance as their only training tool. In the carotid group, each untrained operator acquired two-dimensional, pulsed and color Doppler of the carotid artery. In the ophthalmic group, operators acquired representative images of the anterior chamber of the eye, retina, optic nerve, and nerve sheath. Ultrasound image quality was evaluated by independent imaging experts. RESULTS: Of the studies, 8 of the 10 carotid and 17 of 18 of the ophthalmic images (2 images collected per study) were judged to be diagnostically adequate. The quality of all but one of the ophthalmic images ranged from adequate to excellent. DISCUSSION: Diagnostically-adequate carotid and ophthalmic ultrasound examinations can be obtained by previously untrained operators with assistance from only an audio/video tutorial viewed in real time while scanning. This form of just-in-time training, which can be applied to other examinations, represents an opportunity to acquire important information for NASA flight surgeons and researchers when trained medical personnel are not available or when remote guidance is impractical.


Assuntos
Medicina Aeroespacial/educação , Astronautas/educação , Artérias Carótidas/diagnóstico por imagem , Educação Médica/métodos , Olho/diagnóstico por imagem , Bibliotecas Digitais , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Voo Espacial , Ultrassonografia Doppler em Cores , Ultrassonografia Doppler de Pulso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA