Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Vet Anaesth Analg ; 48(6): 930-934, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34544618

RESUMO

OBJECTIVE: To determine the effect of fraction of inspired oxygen (FiO2) on intrapulmonary shunt fraction as measured by F-shunt in ponies during isoflurane anaesthesia. STUDY DESIGN: Prospective, randomized clinical study. ANIMALS: A group of 23 adult Shetland ponies undergoing a total of 32 anaesthetic procedures. METHODS: Ponies were premedicated intravenously (IV) with detomidine (0.01 mg kg-1) and either morphine (0.1 mg kg-1) or butorphanol (0.02 mg kg-1). Anaesthesia was induced with ketamine (2.2 mg kg-1) and midazolam (0.07 mg kg-1) administered IV. Ponies were randomly allocated to maintenance of anaesthesia with isoflurane in oxygen (group TH; FiO2 = 0.95) or a mixture of oxygen and medical air (group TL; FiO2 = 0.65); all ponies were given a constant rate of infusion of detomidine. Animals were mechanically ventilated to maintain PaCO2 between 40 and 50 mmHg. Arterial blood gas analysis was performed every 30 minutes. The F-shunt equation was calculated for each time point T0, T30, T60 and T90. Data were analysed using linear mixed model analysis and presented as mean ± standard deviation (p < 0.05). RESULTS: PaO2 was greater in group TH than in group TL (TH: 406 ± 90, 438 ± 83, 441 ± 69 and 464 ± 53 mmHg versus TL: 202 ± 90, 186 ± 84, 172 ± 85 and 191 ± 98 mmHg at T0, T30, T60 and T90, respectively; p < 0.0001). In TH, F-shunt was < TL. Significant differences were found at T60 (TH: 13.2% ± 4.3 versus TL: 19.4% ± 8.3; p = 0.016) and T90 (TH: 11.7% ± 3.5 versus TL: 18.6% ± 9.5; p = 0.036). CONCLUSIONS AND CLINICAL RELEVANCE: Our findings do not support a beneficial effect of using a reduced FiO2 to improve oxygenation in anaesthetized and mechanically ventilated Shetland ponies.


Assuntos
Cavalos , Isoflurano , Animais , Oxigênio , Pressão Parcial , Estudos Prospectivos , Respiração Artificial/veterinária
2.
Vet Anaesth Analg ; 48(5): 679-687, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34364790

RESUMO

OBJECTIVE: To use American College of Veterinary Internal Medicine (ACVIM) criteria to evaluate a high-definition oscillometric (HDO) blood pressure monitoring device versus invasive blood pressure (IBP) measurement in normotensive rabbits anaesthetized with two different anaesthetic protocols. STUDY DESIGN: Prospective experimental study. ANIMALS: A group of 20 healthy adult New Zealand White rabbits weighing 4.36 ± 0.37 kg (mean ± standard deviation). MATERIALS AND METHODS: Rabbits were premedicated with butorphanol 0.5 mg kg-1 and midazolam 0.5 mg kg-1 subcutaneously (SC, group BMA) or ketamine 25 mg kg-1 and medetomidine 0.4 mg kg-1 SC (group KM). Anaesthesia was induced with alfaxalone administered intravenously (group BMA) or isoflurane by face mask (group KM) and maintained with isoflurane in oxygen. IBP was measured from the central auricular artery. The cuff for the HDO monitor was placed distal to the left elbow and distal to the left tarsus. Agreement between invasive and HDO measurements was evaluated using Bland-Altman method. RESULTS: In group KM there was better agreement between the HDO device and IBP when the cuff was placed on the thoracic limb, with 100% and 91% of the readings for mean (MAP) and diastolic arterial pressure (DAP), respectively, within 10 mmHg of the IBP measurements. The agreement, although worse, also met the ACVIM criteria for systolic arterial pressure (SAP; 53% of the readings within 10 mmHg). In group BMA, the device met the criteria with the cuff on the thoracic limb only, and only for MAP and DAP (73% and 75% of the measurements within 10 mmHg of the IBP, respectively) but not for SAP (12%). CONCLUSION AND CLINICAL RELEVANCE: The HDO device met most of the ACVIM criteria for noninvasive blood pressure measurement in anaesthetized rabbits, specifically when the cuff was placed distal to the elbow and the anaesthetic protocol included ketamine and medetomidine.


Assuntos
Anestésicos , Pressão Arterial , Pressão Sanguínea , Anestésicos/farmacologia , Animais , Artérias , Pressão Sanguínea/efeitos dos fármacos , Determinação da Pressão Arterial/veterinária , Monitores de Pressão Arterial/veterinária , Estudos Prospectivos , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA