Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Eur J Radiol ; 130: 109194, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32795765

RESUMO

PURPOSE: To investigate clinical, radiologic and pathologic features of B3 lesions diagnosed on VABB targeting microcalcifications, for identifying predictors of malignancy. METHOD: This retrospective multi-centre study included consecutive VABBs performed over a 10-year period on suspicious microcalcifications not associated with other radiological signs diagnosed as B3 on histology from VABB, with outcomes ascertained by surgical excision. Clinical, demographic, radiological and histological (B3 subcategory) data were collected. For statistical analysis (univariate and binary logistic regression), the primary outcome variable was the upgrade rate to malignancy after surgery. Predictors of upgrade to malignancy were identified from clinical, demographic, radiological and pathological variables (including B3 subcategory). RESULTS: Amongst 447 VABBs, there were 57(12.7 %) upgrades to malignancy at surgical histology (36 DCIS and 21 invasive cancer). At univariate analysis, variables significantly associated with increased risk of upgrade to malignancy were age>55 years (p = 0.01), lesion size>10 mm (p < 0.0001), BI-RADS 4b-c and 5 (p = 0.0001), and fine pleomorphic morphology (p = 0.002) of microcalcifications. Binary logistic regression confirmed as significant independent risk factors age, lesion size and BI-RADS category (p = 0.02, 0.02 and 0.0006 respectively). Amongst subcategories of B3 lesions, lobular neoplasia was significantly(p = 0.04) associated with upgrade, confirmed as an independent risk factor [p = 0.03, OR = 2.3(1.1-4.7)]. Flat epithelial atypia was significantly(p = 0.004) associated with reduced odds of upgrade, but binary logistic regression showed only borderline association [p = 0.052, OR = 0.4(0.2-1.01)]. CONCLUSIONS: Across B3 lesions diagnosed on histology from VABB of suspicious microcalcifications, older age, size>10 mm, BI-RADS category≥ 4b on imaging, and lobular neoplasia were risk factors for upgrade to malignancy. This information can be used to discuss patients' tailored management options.


Assuntos
Neoplasias da Mama/patologia , Calcinose/patologia , Adulto , Idoso , Biópsia por Agulha/métodos , Mama/patologia , Neoplasias da Mama/cirurgia , Calcinose/cirurgia , Carcinoma in Situ/patologia , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Intraductal não Infiltrante/cirurgia , Diagnóstico Diferencial , Feminino , Humanos , Biópsia Guiada por Imagem , Modelos Logísticos , Mamografia , Mastectomia , Pessoa de Meia-Idade , Lesões Pré-Cancerosas/patologia , Estudos Retrospectivos
3.
Br J Radiol ; 93(1109): 20190785, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32101449

RESUMO

OBJECTIVE: To compare standard specimen mammography (SSM) with remote intraoperative specimen mammography (ISM) assessment in breast conserving-surgery (BCS) based on operative times, intraoperative additional excision (IAE) and re-intervention rates. METHODS AND MATERIALS: We retrospectively compared 129 consecutive patients (136 lesions) who had BCS with SSM at our centre between 11/2011 and 02/2013 with 138 consecutive patients (144 lesions) who underwent BCS with ISM between 08/2014 and 02/2015.SSM or ISM were performed to confirm the target lesions within the excised specimen and margin adequacy. The utility of SMM and ISM was evaluated considering pathology as gold-standard, using χ2 or Fisher's exact tests for comparison of categorical variables, and non-parametric Mann-Whitney test for continuous variables. RESULTS: The two groups did not statistically differ for age (p = 0.20), lesion size (p = 0.29) and morphology (p = 0.82) or tumor histology type (p = 0.65). Intraoperative time was significantly longer (p < 0.00001) for SSM (132 ± 43 min) than for ISM (90 ± 42 min). The proportions requiring IAE did not significantly differ between SSM group (39/136 lesions (40%)) and ISM group (52/144 lesions (57%)) (p = 0.19), overall and in stratified analysis by mammographic features. Re-intervention rates were not statistically different between the two groups [SSM:19/136 (14%), ISM:13/144 (9%); p = 0.27]. CONCLUSION: The introduction of ISM in BCS significantly reduced surgical time but did not change IAE and re-intervention rates, highlighting facilitated communication between surgeons and radiologists. ADVANCES IN KNOWLEDGE: Compared to standard mammography imaging, the use of ISM significantly reduced surgical time.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/cirurgia , Carcinoma Intraductal não Infiltrante/cirurgia , Mamografia/métodos , Mastectomia Segmentar/métodos , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Feminino , Humanos , Cuidados Intraoperatórios/métodos , Pessoa de Meia-Idade , Duração da Cirurgia , Consulta Remota/métodos , Reoperação/estatística & dados numéricos , Manejo de Espécimes
4.
Eur J Radiol ; 122: 108766, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31809942

RESUMO

PURPOSE: To compare the rates of mastectomy and re-operation after breast-conserving surgery (BCS) among patients who had different pre-operative multi-modality imaging, hence identifying significant predictors of mastectomy and re-operations within each group. METHOD: Retrospective study of consecutive patients with primary breast cancer treated January 2010 - December 2016, divided in 3 groups, undergoing pre-operative local staging respectively with conventional imaging modalities only (2D mammography, ultrasound (US)), conventional imaging and tomosynthesis (DBT) and/or MRI. The primary outcome was identification of significant predictors of surgical outcomes, within each group. Study variables examined in univariate analysis were age, lesion dimension, breast density, multifocality, tumor size, histology, and if associated with outcomes they were included in binary logistic regression analysis. RESULTS: Amongst 1547 patients, patient and tumor characteristics differed across the three groups, as did mastectomy rates which were 18 % (102/562) for 2D + US, 36 % (154/428) for 2D + DBT + US, 45 % (250/557) for 2D+/-DBT + US + MRI(p < 0.001). Variables strongly associated with mastectomy were larger lesions and multifocality (as was multi-modality group). Re-operation rate showed an opposite trend: 12.2 % (56/459) for 2D + US, 8 % (22/272) for 2D + DBT + US, 6.5 % (20/306) for 2D+/-DBT + US + MRI. Re-operation rate for 2D+/-DBT + US + MRI was lower than for 2D + US (p = 0.01) but similar to 2D + DBT + US (p = 0.58). Patients who had 2D + US and re-operations had significantly larger lesions, more underestimation, higher proportion of invasive carcinoma with in-situ component than those who did not require re-operation. CONCLUSIONS: Patients who had larger tumors and multifocal disease were more frequently staged by adding DBT and/or MRI to conventional imaging (mammography and US) which was associated with more extensive surgical treatment but lower reoperation rates.


Assuntos
Neoplasias da Mama/patologia , Idoso , Densidade da Mama/fisiologia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Mastectomia/métodos , Mastectomia Segmentar/métodos , Pessoa de Meia-Idade , Imagem Multimodal , Estadiamento de Neoplasias , Cuidados Pré-Operatórios , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia
5.
Eur Radiol ; 25(9): 2673-81, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25813013

RESUMO

OBJECTIVES: Preoperative breast magnetic resonance (MR) often generates additional suspicious findings needing further investigations. Targeted breast ultrasound (US) is the standard tool to characterize MR additional lesions. The purpose of this study is to evaluate the potential role of digital breast tomosynthesis (DBT) to characterize MR detected additional findings, unidentified at targeted breast US. METHODS: This prospective study included women who a) had biopsy-proven, newly diagnosed breast cancers detected at conventional 2D mammography and/or US, referred to breast MR for tumour staging; and b) had DBT if additional MR findings were not detected at targeted ('second look') US. RESULTS: In 520 patients, MR identified 164 (in 114 women, 22%) additional enhancing lesions. Targeted US identified 114/164 (69.5%) of these, whereas 50/164 (30.5%) remained unidentified. DBT identified 32/50 of these cases, increasing the overall characterization of MR detected additional findings to 89.0% (146/164). Using DBT the identified lesions were significantly more likely to be malignant than benign MR-detected additional lesions (p = 0.04). CONCLUSIONS: DBT improves the characterization of additional MR findings not identified at targeted breast US in preoperative breast cancer staging. KEY POINTS: • Targeted US identified 114 of 164 (69.5%) additional enhancing lesions at preoperative breast MRI. • DBT identified a further 32 of the 50 lesions unidentified on targeted US. • DBT improved the characterization of additional MR findings for breast cancer staging.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética , Mamografia , Ultrassonografia Mamária , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos
6.
Radiol Med ; 120(4): 369-76, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25120079

RESUMO

PURPOSE: The authors sought to compare the diagnostic performance of the Mammotome(®) and EnCor(®) vacuum-assisted breast biopsy (VABB) systems in the assessment of suspicious mammographic microcalcifications. MATERIALS AND METHODS: Between January 2011 and July 2012, a total of 169 VABB were performed by stereotactic guidance on a prone table. The Mammotome(®) 11G (S1) or EnCor(®) 10G (S2) probes were used randomly. Sampling time and the number of frustules collected were considered; sensitivity, specificity, diagnostic accuracy, positive and negative predictive value (PPV, NPV) of both procedures were evaluated, considering the final histological examination as reference (B1, B3, B5 lesions underwent surgical excision; B2 lesion were considered confirmed after a negative follow-up of at least 1 year). RESULTS: There were no statistically significant differences between the two groups of patients according to the number of procedures (S1 82/169; S2 87/169), average age, BIRADS category (4a, b), and average size of the lesions. The two systems did not differ statistically for correlation with the final histology (S1 k = 0.94 ± 0.06; S2 k = 0.92 ± 0.08) and underestimation of B3 lesions or in situ (S1 4.5%; S2 4.3%). Sensitivity, specificity, PPV, NPV, diagnostic accuracy of S1 and S2 were also not statistically different. The systems differed only in sampling time (S1 80; S2 63 s), but not in total procedure time. CONCLUSIONS: Our study confirms the effectiveness of VABB in the assessment of microcalcifications and highlights the lack of significant differences between the two systems in terms of diagnostic performance.


Assuntos
Biópsia por Agulha/instrumentação , Neoplasias da Mama/patologia , Calcinose/patologia , Biópsia Guiada por Imagem/instrumentação , Vácuo , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Técnicas Estereotáxicas
7.
Anticancer Res ; 34(3): 1219-25, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24596363

RESUMO

AIM: To define the accuracy of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to digital mammography (DM) and ultrasound (US) in the preoperative assessment of breast cancer. PATIENTS AND METHODS: We performed a prospective study of 200 consecutive women with histologically-proven breast cancer using the above imaging techniques. Accuracy measurements were estimated using a lesion-by-lesion analysis for unifocal, multifocal/multicentric, bilateral and all carcinomas. We also calculated sensitivity according to breast density. RESULTS: DBT had higher sensitivity than DM (90.7% vs. 85.2%). Combined DM and DBT with US yielded a 97.7% sensitivity; despite high sensitivity of MRI (98.8%), the addition of MRI to combined DM with DBT and US did not significantly improve sensitivity. Overall accuracy did not significantly differ between MRI and DM with DBT and US (92.3% vs. 93.7%). Breast density affected sensitivity of DM and DBT (statistically significant difference for DM), not MRI. CONCLUSION: There is little gain in sensitivity and no gain in overall accuracy, by performing MRI for patients who have been evaluated with DM with DBT and US.


Assuntos
Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética , Mamografia , Tomografia Computadorizada por Raios X , Ultrassonografia Mamária , Adulto , Idoso , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Ductal de Mama/cirurgia , Carcinoma Intraductal não Infiltrante/diagnóstico , Carcinoma Intraductal não Infiltrante/cirurgia , Carcinoma Lobular/diagnóstico , Carcinoma Lobular/cirurgia , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Invasividade Neoplásica , Estadiamento de Neoplasias , Prognóstico , Estudos Prospectivos
8.
Radiol Med ; 119(10): 741-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24610166

RESUMO

OBJECTIVE: This study was done to assess breast density on digital mammography and digital breast tomosynthesis according to the visual Breast Imaging Reporting and Data System (BI-RADS) classification, to compare visual assessment with Quantra software for automated density measurement, and to establish the role of the software in clinical practice. MATERIALS AND METHODS: We analysed 200 digital mammograms performed in 2D and 3D modality, 100 of which positive for breast cancer and 100 negative. Radiological density was assessed with the BI-RADS classification; a Quantra density cut-off value was sought on the 2D images only to discriminate between BI-RADS categories 1-2 and BI-RADS 3-4. Breast density was correlated with age, use of hormone therapy, and increased risk of disease. RESULTS: The agreement between the 2D and 3D assessments of BI-RADS density was high (K 0.96). A cut-off value of 21% is that which allows us to best discriminate between BI-RADS categories 1-2 and 3-4. Breast density was negatively correlated to age (r = -0.44) and positively to use of hormone therapy (p = 0.0004). Quantra density was higher in breasts with cancer than in healthy breasts. CONCLUSIONS: There is no clear difference between the visual assessments of density on 2D and 3D images. Use of the automated system requires the adoption of a cut-off value (set at 21%) to effectively discriminate BI-RADS 1-2 and 3-4, and could be useful in clinical practice.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/patologia , Mamografia , Intensificação de Imagem Radiográfica , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Detecção Precoce de Câncer/métodos , Terapia de Reposição de Estrogênios/efeitos adversos , Feminino , Humanos , Mamografia/métodos , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
9.
Radiol Med ; 118(7): 1119-36, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23801389

RESUMO

PURPOSE: Accurate measurement of breast tumour size is fundamental for treatment planning. We compared the accuracy of digital mammography (DM), digital breast tomosynthesis (DBT), ultrasound (US) and magnetic resonance imaging (MRI) for the preoperative evaluation of breast cancer size. MATERIALS AND METHODS: We retrospectively reviewed 149 breast cancers in 110 patients who underwent DM, DBT, US and MRI between January 2010 and December 2011, before definitive surgery. The lesions were measured by two radiologists, without knowledge of the final histological examination, considered the gold standard. For each imaging modality, the maximum tumour size was measured to the nearest millimetre; the measurements were considered concordant if they were within ± 5 mm. Pearson's correlation coefficient was calculated for each imaging modality. RESULTS: The median pathological tumour size was 22.3 mm. MRI and DBT had a level of concordance with pathology of 70% and 66%, respectively, which was higher than that of DM (54%). DBT and MRI measurements had a better correlation with pathological tumour size (R:0.89 and R:0.92, respectively) compared to DM (R:0.83) and US (R:0.77). CONCLUSIONS: DBT and MRI are superior to DM and US in the preoperative assessment of breast tumour size. DBT seems to improve the accuracy of DM, although MRI remains the most accurate imaging modality for breast cancer extension.


Assuntos
Neoplasias da Mama/patologia , Adulto , Idoso , Neoplasias da Mama/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamografia , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Ultrassonografia Mamária
11.
Mod Pathol ; 22(6): 762-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19287465

RESUMO

Columnar cell lesions of the breast are increasingly recognized at mammography for their tendency to calcify. We studied 392 vacuum-assisted core biopsies performed solely for calcifications to evaluate the frequency of columnar cell lesions, their relationship with radiological risk, appearance of calcifications, and clinical data. Management and follow-up of columnar cell lesions without and with atypia (flat epithelial atypia) was analyzed. Cases with architectural atypia (cribriform spaces and/or micropapillae) were excluded from flat epithelial atypia. Calcifications were within the lumen of acini affected by columnar cell lesions in 137 out of 156 biopsies diagnosed with some columnar cell lesions. These represented 37% of vacuum-assisted core biopsies and 62% of low radiological risk (BI-RADS3) calcifications. High-risk (BI-RADS5) calcifications were never associated with columnar cell lesions. Age and menopausal status were comparable in columnar and in not-columnar cell lesions. Atypia was associated with long-term hormone replacement therapy in both lesions. Surgical biopsy was recommended for all cases with atypia. Flat epithelial atypia, as the only histological findings on vacuum-assisted core biopsies, was never associated with malignancy at surgery. In conclusion, we suggest that surgical excision is not mandatory when flat epithelial atypia is found as the most advanced lesion on vacuum-assisted core biopsy performed for low radiological risk calcifications, and that women should be advised of the possible hormone dependency of this entity.


Assuntos
Doenças Mamárias/patologia , Calcinose/patologia , Biópsia , Biópsia por Agulha , Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Feminino , Humanos , Mamografia , Lesões Pré-Cancerosas/diagnóstico por imagem , Lesões Pré-Cancerosas/patologia , Lesões Pré-Cancerosas/cirurgia , Fatores de Risco