Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 285
Filtrar
1.
J. bras. nefrol ; 46(2): e2024PO01, Apr.-June 2024.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1550491

RESUMO

ABSTRACT The CONVINCE study, recently published in the New England Journal of Medicine, reveals a groundbreaking 23% reduction in the relative risk of all-cause mortality among end-stage kidney patients undergoing high convective volume hemodiafiltration. This significant finding challenges the conventional use of high-flux hemodialysis and offers hope for improving outcomes in chronic kidney disease patients. While some controversies surround the study's findings, including concerns about generalizability and the causes of death, it is essential to acknowledge the study's design and its main outcomes. The CONVINCE study, part of the HORIZON 2020 project, enrolled 1360 patients and demonstrated the superiority of hemodiafiltration in reducing all-cause mortality overall, as well as in specific patient subgroups (elderly, short vintage, non-diabetic, and those without cardiac issues). Interestingly, it was shown that hemodiafiltration had a protective effect against infection, including COVID-19. Future research will address sustainability, dose scaling effects, identification of subgroups especially likely to benefit and cost-effectiveness. However, for now, the findings strongly support a broader adoption of hemodiafiltration in renal replacement therapy, marking a significant advancement in the field.


RESUMO O estudo CONVINCE, publicado recentemente no New England Journal of Medicine, revela uma redução inovadora de 23% no risco relativo de mortalidade por todas as causas entre pacientes renais em estágio terminal submetidos à hemodiafiltração de alto volume de convecção. Esse achado significativo desafia o uso convencional da hemodiálise de alto fluxo e oferece esperança de melhoria dos desfechos em pacientes com doença renal crônica. Embora algumas controvérsias cerquem os achados do estudo, incluindo preocupações sobre a generalização e as causas de óbito, é essencial reconhecer o desenho do estudo e seus principais desfechos. O estudo CONVINCE, parte do projeto HORIZON 2020, inscreveu 1.360 pacientes e demonstrou a superioridade da hemodiafiltração na redução da mortalidade por todas as causas em geral, bem como em subgrupos específicos de pacientes (idosos, HD de curta duração, não diabéticos e aqueles sem problemas cardíacos). Curiosamente, demonstrou-se que a hemodiafiltração teve um efeito protetor contra infecções, incluindo a COVID-19. Pesquisas futuras abordarão sustentabilidade, efeitos de escalonamento da dose, identificação de subgrupos especialmente propensos a se beneficiar e a relação custo-benefício. No entanto, por ora, os achados apoiam fortemente uma adoção mais ampla da hemodiafiltração na terapia renal substitutiva, marcando um avanço significativo na área.

3.
J Bras Nefrol ; 46(2): e2024PO01, 2024.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38358914

RESUMO

The CONVINCE study, recently published in the New England Journal of Medicine, reveals a groundbreaking 23% reduction in the relative risk of all-cause mortality among end-stage kidney patients undergoing high convective volume hemodiafiltration. This significant finding challenges the conventional use of high-flux hemodialysis and offers hope for improving outcomes in chronic kidney disease patients. While some controversies surround the study's findings, including concerns about generalizability and the causes of death, it is essential to acknowledge the study's design and its main outcomes. The CONVINCE study, part of the HORIZON 2020 project, enrolled 1360 patients and demonstrated the superiority of hemodiafiltration in reducing all-cause mortality overall, as well as in specific patient subgroups (elderly, short vintage, non-diabetic, and those without cardiac issues). Interestingly, it was shown that hemodiafiltration had a protective effect against infection, including COVID-19. Future research will address sustainability, dose scaling effects, identification of subgroups especially likely to benefit and cost-effectiveness. However, for now, the findings strongly support a broader adoption of hemodiafiltration in renal replacement therapy, marking a significant advancement in the field.


Assuntos
Hemodiafiltração , Falência Renal Crônica , Humanos , Idoso , Falência Renal Crônica/terapia , Resultado do Tratamento , Diálise Renal/efeitos adversos , Hemodiafiltração/efeitos adversos , Rim
4.
J Am Soc Nephrol ; 35(2): 167-176, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37967469

RESUMO

SIGNIFICANCE STATEMENT: This large observational cohort study aimed to investigate the relationship between dialysate and plasma sodium concentrations and mortality among maintenance hemodialysis patients. Using a large multinational cohort of 68,196 patients, we found that lower dialysate sodium concentrations (≤138 mmol/L) were independently associated with higher mortality compared with higher dialysate sodium concentrations (>138 mmol/L). The risk of death was lower among patients exposed to higher dialysate sodium concentrations, regardless of plasma sodium levels. These results challenge the prevailing assumption that lower dialysate sodium concentrations improve outcomes in hemodialysis patients. The study confirms that until robust evidence from randomized trials that are underway is available, nephrologists should remain cautious in reconsideration of dialysate sodium prescribing practices to optimize cardiovascular outcomes and reduce mortality in this population. BACKGROUND: Excess mortality in hemodialysis (HD) patients is largely due to cardiovascular disease and is associated with abnormal fluid status and plasma sodium concentrations. Ultrafiltration facilitates the removal of fluid and sodium, whereas diffusive exchange of sodium plays a pivotal role in sodium removal and tonicity adjustment. Lower dialysate sodium may increase sodium removal at the expense of hypotonicity, reduced blood volume refilling, and intradialytic hypotension risk. Higher dialysate sodium preserves blood volume and hemodynamic stability but reduces sodium removal. In this retrospective cohort, we aimed to assess whether prescribing a dialysate sodium ≤138 mmol/L has an effect on survival outcomes compared with dialysate sodium >138 mmol/L after adjusting for plasma sodium concentration. METHODS: The study population included incident HD patients from 875 Fresenius Medical Care Nephrocare clinics in 25 countries between 2010 and 2019. Baseline dialysate sodium (≤138 or >138 mmol/L) and plasma sodium (<135, 135-142, >142 mmol/L) concentrations defined exposure status. We used multivariable Cox regression model stratified by country to model the association between time-varying dialysate and plasma sodium exposure and all-cause mortality, adjusted for demographic and treatment variables, including bioimpedance measures of fluid status. RESULTS: In 2,123,957 patient-months from 68,196 incident HD patients with on average three HD sessions per week dialysate sodium of 138 mmol/L was prescribed in 63.2%, 139 mmol/L in 15.8%, 140 mmol/L in 20.7%, and other concentrations in 0.4% of patients. Most clinical centers (78.6%) used a standardized concentration. During a median follow-up of 40 months, one third of patients ( n =21,644) died. Dialysate sodium ≤138 mmol/L was associated with higher mortality (multivariate hazard ratio for the total population (1.57, 95% confidence interval, 1.25 to 1.98), adjusted for plasma sodium concentrations and other confounding variables. Subgroup analysis did not show any evidence of effect modification by plasma sodium concentrations or other patient-specific variables. CONCLUSIONS: These observational findings stress the need for randomized evidence to reliably define optimal standard dialysate sodium prescribing practices.


Assuntos
Soluções para Diálise , Falência Renal Crônica , Humanos , Soluções para Diálise/efeitos adversos , Estudos Retrospectivos , Falência Renal Crônica/complicações , Diálise Renal/métodos , Sódio
5.
Nephrol Dial Transplant ; 39(2): 233-241, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-37433572

RESUMO

BACKGROUND: Ischaemic end-organ damage during haemodialysis (HD) is a significant problem that may be ameliorated by intradialytic cooling. A randomised trial was performed to compare standard HD (SHD; dialysate temperature 37°C) and programmed cooling of the dialysate [thermocontrolled HD (TCHD)] using multiparametric magnetic resonance imaging (MRI) to assess structural, functional and blood flow changes in the heart, brain and kidneys. METHODS: Prevalent HD patients were randomly allocated to receive either SHD or TCHD for 2 weeks before undergoing serial MRI at four time points: pre-, during (30 min and 180 min) and post-dialysis. MRI measures include cardiac index, myocardial strain, longitudinal relaxation time (T1), myocardial perfusion, internal carotid and basilar artery flow, grey matter perfusion and total kidney volume. Participants then crossed to the other modality to repeat the study protocol. RESULTS: Eleven participants completed the study. Separation in blood temperature between TCHD (-0.1 ± 0.3°C) and SHD (+0.3 ± 0.2°C; P = .022) was observed, although there was no difference in tympanic temperature changes between arms. There were significant intradialytic reductions in cardiac index, cardiac contractility (left ventricular strain), left carotid and basilar artery blood flow velocities, total kidney volume, longitudinal relaxation time (T1) of the renal cortex and transverse relaxation rate (T2*) of the renal cortex and medulla, but no differences between arms. Pre-dialysis T1 of the myocardium and left ventricular wall mass index were lower after 2 weeks of TCHD compared with SHD [1266 ms (interquartile range 1250-1291) versus 1311 ± 58 ms, P = .02; 66 ± 22 g/m2 versus 72 ± 23 g/m2, P = .004]. CONCLUSIONS: HD adversely affects cardiac function, reduces carotid and basilar artery blood flow and total kidney volume, but mild dialysate cooling using a biofeedback module did not result in differences in intradialytic MRI measures compared with SHD.


Assuntos
Falência Renal Crônica , Diálise Renal , Humanos , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Rim , Soluções para Diálise , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem
6.
Front Med (Lausanne) ; 10: 1268748, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38034546

RESUMO

Despite significant progress in dialysis modalities, intermittent renal replacement therapy remains an "unphysiological" treatment that imperfectly corrects uremic disorders and may lead to low-grade chronic inflammation, neutrophil activation, and oxidative stress due to repetitive blood/membrane interactions contributing to the "remaining uremic syndrome" and cardiovascular disease burden of hemodialysis patients. Understanding dialysis bioincompatibility pathways still remains a clinical and biochemical challenge. Indeed, surrogate biomarkers of inflammation including C-reactive protein could not discriminate between all components involved in these complex pathways. A few examples may serve to illustrate the case. Cytokine release during dialysis sessions may be underestimated due to their removal using high-flux dialysis or hemodiafiltration modalities. Complement activation is recognized as a key event of bioincompatibility. However, it appears as an early and transient event with anaphylatoxin level normalization at the end of the dialysis session. Complement activation is generally assumed to trigger leukocyte stimulation leading to proinflammatory mediators' secretion and oxidative burst. In addition to being part of the innate immune response involved in eliminating physically and enzymatically microbes, the formation of Neutrophil Extracellular Traps (NETs), known as NETosis, has been recently identified as a major harmful component in a wide range of pathologies associated with inflammatory processes. NETs result from the neutrophil degranulation induced by reactive oxygen species overproduction via NADPH oxidase and consist of modified chromatin decorated with serine proteases, elastase, bactericidal proteins, and myeloperoxidase (MPO) that produces hypochlorite anion. Currently, NETosis remains poorly investigated as a sensitive and integrated marker of bioincompatibility in dialysis. Only scarce data could be found in the literature. Oxidative burst and NADPH oxidase activation are well-known events in the bioincompatibility phenomenon. NET byproducts such as elastase, MPO, and circulating DNA have been reported to be increased in dialysis patients more specifically during dialysis sessions, and were identified as predictors of poor outcomes. As NETs and MPO could be taken up by endothelium, NETs could be considered as a vascular memory of intermittent bioincompatibility phenomenon. In this working hypothesis article, we summarized the puzzle pieces showing the involvement of NET formation during hemodialysis and postulated that NETosis may act as a disease modifier and may contribute to the comorbid burden associated with dialysis bioincompatibility.

7.
Infect Prev Pract ; 5(3): 100292, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37692534

RESUMO

Background: Compliance with dialysis fluid ultrapurity standards is a paramount for online modalities. More than 200 dialysis fluid samples have been analyzed monthly for years in our two dialysis units, with compliant microbiological results until mid-2020. Aim: In mid-2020, an unusual occurrence (30%) of contaminated dialysis fluids in dialysis units led us to investigate to determine the source. Methods: Microbiological methods for aquaphilic bacteria culturing and endotoxin detection in dialysis fluids were routinely performed on a monthly basis for all dialysis machines. As the contamination appeared randomly and almost simultaneously in our two units without any routine change or febrile syndrome, we searched for a common cause. Supplier's sampling kits as well as microbiological laboratory procedures were scrupulously investigated. Findings: 21 out of 30 sampling bags filled with sterile water brought back numerous fungi and bacteria. Laboratory's investigation, through the negative control tests performed routinely, exonerated the lab. All batches of bags analyzed later showed variable levels of contamination according to their transport/storage mode or date of manufacturing. Analyses performed by the supplier - methods complying with the medical device's standards but different from those recommended for dialysis fluids purity - remained negative. Conclusion: Our investigation revealed that the contamination of our sampling kits came presumably from the manufacturer's supplying chain. Such false-positive results findings, created serious safety issues and disturbed clinical activities since positive machines were quarantined. Furthermore, it raised a serious concern about manufacturing, microbiological checking and shipping methods for the medical device industry that deserve further attention.

8.
Front Nephrol ; 3: 1148565, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37675376

RESUMO

Cardiovascular disease (CVD) is a major burden in dialysis-dependent chronic kidney disease (CKD5D) patients. Several factors contribute to this vulnerability including traditional risk factors such as age, gender, life style and comorbidities, and non-traditional ones as part of dialysis-induced systemic stress. In this context, it appears of utmost importance to bring a closer attention to CVD monitoring in caring for CKD5D patients to ensure early and appropriate intervention for improving their outcomes. Interestingly, new home-used, self-operated, connected medical devices offer convenient and new tools for monitoring in a fully automated and ambulatory mode CKD5D patients during the interdialytic period. Sensoring devices are installed with WiFi or Bluetooth. Some devices are also available in a cellular version such as the Withings Remote Patient Monitoring (RPM) solution. These devices analyze the data and upload the results to Withings HDS (Hybrid data security) platform servers. Data visualization can be viewed by the patient using the Withings Health Mate application on a smartphone, or with a web interface. Health Care Professionals (HCP) can also visualize patient data via the Withings web-based RPM interface. In this narrative essay, we analyze the clinical potential of pervasive wearable sensors for monitoring ambulatory dialysis patients and provide an assessment of such toolkit digital medical health devices currently available on the market. These devices offer a fully automated, unobtrusive and remote monitoring of main vital functions in ambulatory subjects. These unique features provide a multidimensional assessment of ambulatory CKD5D patients covering most physiologic functionalities, detecting unexpected disorders (i.e., volume overload, arrhythmias, sleep disorders) and allowing physicians to judge patient's response to treatment and recommendations. In the future, the wider availability of such pervasive health sensing and digital technology to monitor patients at an affordable cost price will improve the personalized management of CKD5D patients, so potentially resulting in improvements in patient quality of life and survival.

9.
Semin Dial ; 2023 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-37697455

RESUMO

INTRODUCTION: The purity of water and dialysis fluids is of utmost importance in ensuring the safe and effective administration of hemodialysis treatment to patients with chronic kidney disease. It is crucial to enforce compliance with international standards for dialysis water and fluids, as this is mandatory in reducing chemical hazards, mitigating the adverse effects of bioincompatibility resulting from contaminated water and ultimately enhancing long-term patient outcomes. STANDARDS AND RISKS: Within this comprehensive review, we highlight the presence of water contaminants and thoroughly assess the existing international standards for dialysis water and fluids, spanning from pure to ultrapure. Additionally, we delve into the fundamental components of water purification and present a comprehensive range of water treatment options, encompassing pre-treatment, primary treatment (reverse osmosis), and tertiary water treatment. Furthermore, we outline recommended monitoring and maintenance procedures, ensuring the consistent delivery of high-quality water and dialysis fluids at the point of care. WATER PURIFICATION AND MONITORING SUSTAINABILITY AND FUTURE CHALLENGES: Importantly, we raise concerns regarding the sustainability and conservation of water resources in hemodialysis treatment. It is imperative that these concerns be addressed in the future to avert the potential shortage of this essential resource. CONCLUSION: In conclusion, the contemporary landscape of hemodialysis conditions has engendered an urgent necessity for advanced water treatment systems and optimized delivery of dialysis fluids. This review serves as a comprehensive update on the latest technological advancements aimed at meeting these critical demands. Dialysis water and fluids must adhere to increasingly stringent purity constraints, encompassing both biochemical and microbiological perspectives.

11.
J Clin Med ; 12(14)2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37510847

RESUMO

Tunneled central venous catheters (CVC) are mainly considered as a rescue vascular access option in dialysis but are still used on approximately one quarter of prevalent patients worldwide even though they are associated with poor performances and higher risks. STUDY DESIGN: in this retrospective single-center study, we aimed to report on the clinical performances achieved with high-flow tunneled CVCs (DualCath or DCath) and compared them with arteriovenous accesses (AVAs, e.g., AV fistula, AV graft, and Thomas Shunt) in a hospital-based dialysis unit. METHODS: Sixty-eight stage 5 chronic kidney disease dialysis-dependent patients (CKD5D) receiving high volume hemodiafiltration were followed-up with for 30 months. The study consisted of two phases: baseline cross-sectional and longitudinal follow-ups of key performance indicators. Clinical performances consisting of effective blood flow and blood volume, recirculation, urea and ionic Kt/V, total Kt, ultrafiltration volume, and percent reduction in ß2-M were measured monthly as part of quality control in our unit. RESULTS: At baseline, the effective blood flow using a DCath was close to 400 mL/min, similar to an AVA. Recirculation with a DCath (7%, 6-13%) was higher than with an AVA. The diffusive dialysis dose delivered with a DCath (spKt and eKt/V) and convective dialysis dose achieved with a DCath were slightly lower than those achieved with AVAs, but they were still much higher than is recommended by guidelines. The percent reduction in ß2-M achieved with a DCath was also 4 to 10% lower than that achieved with an AVA. On longitudinal follow-up, the main clinical performance indicators of DCaths (total Kt and total ultrafiltration volume, L/session) were maintained as very stable over time and close to those achieved with AVAs. CONCLUSIONS: As shown in this study, high-flow DualCath tunneled two-single-lumen silicone catheters may be used to deliver high volume hemodiafiltration in a reliable and consistent manner without compromising clinical performance. These results relied on the specific design of the two silicone cannulas and the strict adherence to best catheter practices.

12.
Blood Purif ; 52(6): 564-577, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37290421

RESUMO

The primary objective of hemodialysis (HD) is lowering concentrations of organic uremic toxins that accumulate in blood in end-stage kidney disease (ESKD) and redress imbalances of inorganic compounds in particular sodium and water. Removal by ultrafiltration of excess fluid that has accumulated during the dialysis-free interval is a vital aspect of each HD session. Most HD patients are volume overloaded, with ∼25% of patients having severe (>2.5 L) fluid overload (FO). The potentially serious complications of FO contribute to the high cardiovascular morbidity and mortality observed in the HD population. Weekly cycles imposed by the schedule of HD treatments create a deleterious and unphysiological "tide phenomenon" marked by sodium-volume overload (loading) and depletion (unloading). Fluid overload-related hospitalizations are frequent and costly, with average cost estimates of $ 6,372 per episode, amounting to some $ 266 million total costs over a 2-year period in a US dialysis population. Various strategies (e.g., dry weight management or use of fluids with different sodium concentrations) have been attempted to rectify FO in HD patients but have met with limited success largely due to imprecise and cumbersome, or costly, approaches. In recent years, conductivity-based technologies have been refined to actively restore sodium and fluid imbalance and maintain the predialysis plasma sodium set point (plasma tonicity) of each patient. By automatically controlling the dialysate-plasma sodium gradient based on the specific patient needs throughout a session, an individualized sodium dialysate prescription can be delivered. Maintaining precise sodium mass balance helps better control of blood pressure, reduces FO, and thus tends to prevent hospitalization for congestive heart failure. We present the case for personalized salt and fluid management via a machine-integrated sodium management tool. Results from proof-of-principle clinical trials indicate that the tool enables individualized sodium-fluid volume control during each HD session. Its application in routine clinical practice has the potential to mitigate the substantial economic burden of hospitalizations attributed to volume overload complications in HD. Additionally, such a tool would contribute toward reduced symptomology and dialysis-induced multiorgan damage in HD patients and to improving their treatment perception and quality of life which matters most to patients.


Assuntos
Insuficiência Cardíaca , Falência Renal Crônica , Desequilíbrio Hidroeletrolítico , Humanos , Sódio , Qualidade de Vida , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Soluções para Diálise , Desequilíbrio Hidroeletrolítico/etiologia , Desequilíbrio Hidroeletrolítico/prevenção & controle , Insuficiência Cardíaca/complicações
13.
N Engl J Med ; 389(8): 700-709, 2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37326323

RESUMO

BACKGROUND: Several studies have suggested that patients with kidney failure may benefit from high-dose hemodiafiltration as compared with standard hemodialysis. However, given the limitations of the various published studies, additional data are needed. METHODS: We conducted a pragmatic, multinational, randomized, controlled trial involving patients with kidney failure who had received high-flux hemodialysis for at least 3 months. All the patients were deemed to be candidates for a convection volume of at least 23 liters per session (as required for high-dose hemodiafiltration) and were able to complete patient-reported outcome assessments. The patients were assigned to receive high-dose hemodiafiltration or continuation of conventional high-flux hemodialysis. The primary outcome was death from any cause. Key secondary outcomes were cause-specific death, a composite of fatal or nonfatal cardiovascular events, kidney transplantation, and recurrent all-cause or infection-related hospitalizations. RESULTS: A total of 1360 patients underwent randomization: 683 to receive high-dose hemodiafiltration and 677 to receive high-flux hemodialysis. The median follow-up was 30 months (interquartile range, 27 to 38). The mean convection volume during the trial in the hemodiafiltration group was 25.3 liters per session. Death from any cause occurred in 118 patients (17.3%) in the hemodiafiltration group and in 148 patients (21.9%) in the hemodialysis group (hazard ratio, 0.77; 95% confidence interval, 0.65 to 0.93). CONCLUSIONS: In patients with kidney failure resulting in kidney-replacement therapy, the use of high-dose hemodiafiltration resulted in a lower risk of death from any cause than conventional high-flux hemodialysis. (Funded by the European Commission Research and Innovation; CONVINCE Dutch Trial Register number, NTR7138.).


Assuntos
Hemodiafiltração , Falência Renal Crônica , Insuficiência Renal , Humanos , Hemodiafiltração/efeitos adversos , Hemodiafiltração/métodos , Falência Renal Crônica/complicações , Falência Renal Crônica/mortalidade , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Insuficiência Renal/etiologia , Resultado do Tratamento
14.
J Clin Epidemiol ; 159: 128-138, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37105321

RESUMO

OBJECTIVES: To investigate whether a multi-item performance outcome measure, the physical performance test (PPT), can be calibrated to a common scale with patient-reported outcome measures, using the Patient-Reported Outcomes Measurement Information System (PROMIS) physical function (PF) metric. STUDY DESIGN AND SETTING: We analyzed baseline data (N = 1,113) from the CONVINCE study, an international trial in end-stage kidney disease patients comparing high-dose hemodiafiltration with high-flux hemodialysis. Assumptions of item response theory (IRT) modelling were investigated for the combined set of the nine-item PPT and a four-item PROMIS PF short form (PROMIS-PF4a). We applied unidimensional IRT linking for calibrating the PPT to the PROMIS PF metric. RESULTS: Although some evidence for multidimensionality was found, classical test statistics (Cronbach's Alpha = 0.93), Mokken (Loevinger's H = 0.50), and bifactor analysis (explained common variance = 0.65) indicated that PPT and PROMIS-PF4a items can be used to assess a common PF construct. On the group level, the agreement between PROMIS-PF4a and linked PPT scores was stable across several subsamples. On the individual level, scores differed considerably. CONCLUSION: We found preliminary evidence that the PPT can be linked to the PROMIS PF metric in hemodialysis patients, enabling group comparisons across patient-reported outcome and performance outcome measures. Alternative linking methods should be applied in future studies using a more comprehensive PROMIS PF item set.


Assuntos
Desempenho Físico Funcional , Diálise Renal , Humanos , Inquéritos e Questionários , Medidas de Resultados Relatados pelo Paciente , Avaliação de Resultados em Cuidados de Saúde
15.
Nephrol Dial Transplant ; 38(10): 2248-2256, 2023 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-36861328

RESUMO

BACKGROUND: The 5-year mortality rate for haemodialysis patients is over 50%. Acute and chronic disturbances in salt and fluid homeostasis contribute to poor survival and are established as individual mortality risk factors. However, their interaction in relation to mortality is unclear. METHODS: We used the European Clinical Database 5 to investigate in a retrospective cohort analysis the relationship between transient hypo- and hypernatremia, fluid status and mortality risk of 72 163 haemodialysis patients from 25 countries. Incident haemodialysis patients with at least one valid measurement of bioimpedance spectroscopy were followed until death or administrative censoring from 1 January 2010 to 4 December 2019. Fluid overload and depletion were defined as >2.5 L above, and -1.1 L below normal fluid status, respectively. N = 2 272 041 recorded plasma sodium and fluid status measurements were available over a monthly time grid and analysed in a Cox regression model for time-to-death. RESULTS: Mortality risk of hyponatremia (plasma sodium <135 mmol/L) was slightly increased when fluid status was normal [hazard ratio (HR) 1.26, 95% confidence interval (CI) 1.18-1.35], increased by half when patients were fluid depleted (HR 1.56, 95% CI 1.27-1.93) and accelerated during fluid overload (HR 1.97, 95% CI 1.82-2.12). CONCLUSIONS: Plasma sodium and fluid status act independently as risk factors on mortality. Patient surveillance of fluid status is especially important in the high-risk subpopulation of patients with hyponatremia. Prospective patient-level studies should examine the effects of chronic hypo- and hypernatremia, risk determinants, and their outcome risk.


Assuntos
Insuficiência Cardíaca , Hipernatremia , Hiponatremia , Desequilíbrio Hidroeletrolítico , Humanos , Diálise Renal/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Sódio , Desequilíbrio Hidroeletrolítico/complicações , Insuficiência Cardíaca/complicações
16.
BMC Nephrol ; 24(1): 35, 2023 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-36792998

RESUMO

BACKGROUND: Vascular calcification is a major contributor to the high cardiac burden among hemodialysis patients. A novel in vitro T50-test, which determines calcification propensity of human serum, may identify patients at high risk for cardiovascular (CV) disease and mortality. We evaluated whether T50 predicts mortality and hospitalizations among an unselected cohort of hemodialysis patients. METHODS: This prospective clinical study included 776 incident and prevalent hemodialysis patients from 8 dialysis centers in Spain. T50 and fetuin-A were determined at Calciscon AG, all other clinical data were retrieved from the European Clinical Database. After their baseline T50 measurement, patients were followed for two years for the occurrence of all-cause mortality, CV-related mortality, all-cause and CV-related hospitalizations. Outcome assessment was performed with proportional subdistribution hazards regression modelling. RESULTS: Patients who died during follow-up had a significantly lower T50 at baseline as compared to those who survived (269.6 vs. 287.7 min, p = 0.001). A cross-validated model (mean c statistic: 0.5767) identified T50 as a linear predictor of all-cause-mortality (subdistribution hazard ratio (per min): 0.9957, 95% CI [0.9933;0.9981]). T50 remained significant after inclusion of known predictors. There was no evidence for prediction of CV-related outcomes, but for all-cause hospitalizations (mean c statistic: 0.5284). CONCLUSION: T50 was identified as an independent predictor of all-cause mortality among an unselected cohort of hemodialysis patients. However, the additional predictive value of T50 added to known mortality predictors was limited. Future studies are needed to assess the predictive value of T50 for CV-related events in unselected hemodialysis patients.


Assuntos
Doenças Cardiovasculares , Calcificação Vascular , Humanos , Estudos Prospectivos , Diálise Renal/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Calcificação Vascular/complicações , Modelos de Riscos Proporcionais
17.
J Clin Med ; 12(4)2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36835894

RESUMO

The RECAP study reports results and outcomes (clinical performances, patient acceptance, cardiac outcomes, and technical survival) achieved with the S3 system used as an intensive home hemodialysis (HHD) platform over a three-year French multicenter study. Ninety-four dialysis patients issued from ten dialysis centers and treated more than 6 months (mean follow-up: 24 months) with S3 were included. A two-hour treatment time was maintained in 2/3 of patients to deliver 25 L of dialysis fluid, while 1/3 required up to 3 h to achieve 30 L. The additional convection volume produced by means of the SeCoHD tool (internal filtration backfiltration) was 3 L/session, and the net ultrafiltration produced to achieve dry weight was 1.4 L/session. On a weekly basis, an average 156 L of dialysate corresponding to 94 L of urea clearance when considering 85% dialysate saturation under low flow conditions was delivered. Such urea clearance was equivalent to 9.2 [8.0-13.0] mL/min weekly urea clearance and a standardized Kt/V of 2.5 [1.1-4.5]. The predialysis concentration of selected uremic markers remained remarkably stable over time. Fluid volume status and blood pressure were adequately controlled by means of a relatively low ultrafiltration rate (7.9 mL/h/kg). Technical survival on S3 was 72% and 58% at 1 and 2 years, respectively. The S3 system was easily handled and kept by patients at home, as indicated by technical survival. Patient perception was improved, while treatment burden was reduced. Cardiac features (assessed in a subset of patients) tended to improve over time. Intensive hemodialysis relying on the S3 system offers a very appealing option for home treatment with quite satisfactory results, as shown in the RECAP study throughout a two-year follow-up time, and offers the best bridging solution to kidney transplantation.

18.
Bioengineering (Basel) ; 10(2)2023 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-36829639

RESUMO

Despite the significant medical and technical improvements in the field of dialytic renal replacement modalities, morbidity and mortality are excessively high among patients with end-stage kidney disease, and most interventional studies yielded disappointing results. Hemodiafiltration, a dialysis method that was implemented in clinics many years ago and that combines the two main principles of hemodialysis and hemofiltration-diffusion and convection-has had a positive impact on mortality rates, especially when delivered in a high-volume mode as a surrogate for a high convective dose. The achievement of high substitution volumes during dialysis treatments does not only depend on patient characteristics but also on the dialyzer (membrane) and the adequately equipped hemodiafiltration machine. The present review article summarizes the technical aspects of online hemodiafiltration and discusses present and ongoing clinical studies with regards to hard clinical and patient-reported outcomes.

19.
Artif Organs ; 47(6): 999-1006, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36527419

RESUMO

BACKGROUND: A higher sodium (Na) dialysate concentration is recommended during renal replacement therapy (RRT) of acute kidney injury (AKI) to improve intradialytic hemodynamic tolerance, but it may lead to Na loading to the patient. We aimed to evaluate Na flux according to Na dialysate and infusate concentrations at 140 and 145 mmol/L during hemodialysis (HD) and hemodiafiltration (HDF). METHODS: Fourteen AKI patients that underwent consecutive HD or HDF sessions with Na dialysate/infusate at 140 and 145 mmol/L were included. Per-dialytic flux of Na was estimated using mean sodium logarithmic concentration including diffusive and convective influx. We compared the flux of sodium between HD140 and 145, and between HDF140 and 145. RESULTS: Nine HD140, ten HDF140, nine HD145, and 11 HDF145 sessions were analyzed. A Na gradient from the dialysate/replacement fluid to the patient was observed with dialysate/infusate Na at 145 mmol/L in both HD and HDF (p = 0.01). The comparison of HD145 to HD140 showed that higher Na dialysate induced a diffusive Na gradient to the patient (163 mmol vs. -25 mmol, p = 0.004) and that of HDF145 to -140 (211 vs. 36 mmol, p = 0.03) as well. Intradialytic hemodynamic tolerance was similar across all RRT sessions. CONCLUSIONS: During both HD and HDF, a substantial Na loading occurred with a Na dialysate and infusate at 145 mmol/L. This Na loading is smaller in HDF with Na dialysate and infusate concentration at 140 mmol/L and inversed with HD140. Clinical and intradialytic hemodynamic tolerance was fair regardless of Na dialysate and infusate.


Assuntos
Injúria Renal Aguda , Hemodiafiltração , Falência Renal Crônica , Humanos , Hemodiafiltração/efeitos adversos , Soluções para Diálise/efeitos adversos , Sódio , Diálise Renal/efeitos adversos , Injúria Renal Aguda/terapia , Falência Renal Crônica/terapia
20.
Semin Dial ; 36(2): 86-106, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36437498

RESUMO

BACKGROUND: This systematic review was performed to identify recent published comparative evidence on the efficacy, effectiveness, and safety of expanded hemodialysis (HDx) versus high-flux HD and/or hemodiafiltration (HDF) for long-term outcomes in end-stage kidney disease. METHODS: Systematic literature review was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist. Medline, Medline® Epub Ahead of Print, EconLit, Embase, and EBM reviews were searched to identify relevant publications from 2013 onwards. Eligibility criteria included clinical studies reporting mortality, hospitalizations, cardiovascular outcomes, economic evaluations, cost studies, and quality of life (QoL) studies. RESULTS: A total of 79 relevant studies were identified with 29 prioritized for detailed analysis; four compared HDx to HD, one compared HDF and HDx, and 24 compared HDF with HD. A total of 13 randomized controlled trial (RCT)-based studies were identified; 11 compared HDF with HD, one compared HDx with HD, and one compared HDF with HDx. Follow-up duration ranged from 16 weeks to 7 years for HDF studies and from 12 weeks to 1 year for HDx studies. HDF showed significant improvements in mortality, cardiovascular outcomes, hospitalizations, and QoL versus high-flux HD. One study reported mortality outcomes for HDx and found no difference versus HDF. QoL benefits with HDx were reported in a small number of studies. CONCLUSION: The efficacy and safety of HDF is supported by a robust evidence base that includes several RCTs. While HDx may offer benefits over high-flux HD, long-term studies are required to compare HDx with online high volume HDF. REGISTRATION: PROSPERO registration number: CRD42022301009.


Assuntos
Hemodiafiltração , Falência Renal Crônica , Humanos , Diálise Renal , Qualidade de Vida , Hospitalização , Ensaios Clínicos Controlados Aleatórios como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA