Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Comput Biol Med ; 173: 108245, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38531253

RESUMO

PURPOSE: This study aimed to evaluate and optimize intraocular lens (IOL) power selection for cataract patients with high axial myopia receiving trifocal IOLs. DESIGN: A multi-center, retrospective observational case series was conducted. Patients having an axial length ≥26 mm and undergoing cataract surgery with trifocal IOL implanted were studied. METHODS: Preoperative biometric and postoperative outcome data from 139 eyes were collected to train and test various machine learning (ML) models (support vector machine, linear regression, and stacking regressor) using five-fold cross-validation. The models' performance was further validated externally using data from 48 eyes enrolled from other hospitals. Performance of seven IOL calculation formulas (BUII, Kane, EVO, K6, DGS, Holladay I, and SRK/T) were examined with and without ML models. RESULTS: The results of cross-validation revealed improvements across all IOL calculation formulas, especially for K6 and Holladay I. The model increased the percentage of eyes with a prediction error (PE) within ±0.50 D from 71.94% to 79.14% for K6, and from 35.25% to 51.80% for Holladay I. In external validation involving 48 patients from other centers, six out of seven formulas demonstrated a reduction in the mean absolute error (MAE). K6's PE within ±0.50 D improved from 62.50% to 77.08%, and Holladay I from 16.67% to 58.33%. CONCLUSIONS: In this study, we conducted a comprehensive evaluation of seven IOL power calculation formulas in high axial myopia cases and explored the effectiveness of the Stacking Regressor model in augmenting their accuracy. Of these formulas, K6 and Holladay I exhibited the most significant improvements, suggesting that integrating ML may have varying levels of effectiveness across different formulas but holds substantial promise in improving the predictability of IOL power calculations in patients with long eyes.


Assuntos
Catarata , Lentes Intraoculares , Miopia , Humanos , Miopia/cirurgia , Óptica e Fotônica , Refração Ocular , Estudos Retrospectivos
2.
Patterns (N Y) ; 5(2): 100928, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38370128

RESUMO

Data-driven machine learning, as a promising approach, possesses the capability to build high-quality, exact, and robust models from ophthalmic medical data. Ophthalmic medical data, however, presently exist across disparate data silos with privacy limitations, making centralized training challenging. While ophthalmologists may not specialize in machine learning and artificial intelligence (AI), considerable impediments arise in the associated realm of research. To address these issues, we design and develop FedEYE, a scalable and flexible end-to-end ophthalmic federated learning platform. During FedEYE design, we adhere to four fundamental design principles, ensuring that ophthalmologists can effortlessly create independent and federated AI research tasks. Benefiting from the design principles and architecture of FedEYE, it encloses numerous key features, including rich and customizable capabilities, separation of concerns, scalability, and flexible deployment. We also validated the applicability of FedEYE by employing several prevalent neural networks on ophthalmic disease image classification tasks.

3.
Indian J Ophthalmol ; 72(Suppl 2): S176-S182, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38271414

RESUMO

With the progress in refractive cataract surgery, more intraocular lens (IOL) power formulas have been introduced with the aim of reducing the postoperative refractive error. The postoperative IOL position is critical to IOL power calculations. Therefore, the improvements in postoperative IOL position prediction will enable better selection of IOL power and postoperative refraction. In the past, the postoperative IOL position was mainly predicted by preoperative anterior segment parameters such as preoperative axial length (AL), anterior chamber depth (ACD), and corneal curvature. In recent years, some novel methods including the intraoperative ACD, crystalline lens geometry, and artificial intelligence (AI) of prediction of postoperative IOL position have been reported. This article attempts to give a review about the research progress on prediction of the postoperative IOL position.


Assuntos
Cristalino , Lentes Intraoculares , Facoemulsificação , Erros de Refração , Humanos , Inteligência Artificial , Refração Ocular , Cristalino/cirurgia , Biometria
4.
Medicine (Baltimore) ; 102(37): e35153, 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37713836

RESUMO

To investigate the clinical pathways via which the glaucomatous optic nerve damage (GOND) occurred in cases with glaucomatocyclitic crisis (also called Posner-Schlossman syndrome, PSS). A retrospective study was conducted, 59 PSS patients with confirmed GOND were screened out from 190 PSS cases and followed up for a period of 5 ±â€…3.3 years. Clinical data were retrospectively analyzed systematically and dynamically, including intraocular pressure and its dynamic change, appearance of fundus, visual field and the state of anterior chamber angle in initial and later period during the episodes and intermission of PSS. Based on the clinical data, a classification and standard for the clinical pathways of GOND were established, and the clinical pathway of GOND in each patient was classified accordingly. There are at least 4 clinical pathways of GOND in PSS patients, namely: Type A: GOND was simply caused by the accumulation effect of high IOP during many attacks of PSS itself. Type B: GOND was resulted from the combined action of PSS itself and another type of secondary open-angle glaucoma. The recurrent inflammation during the episodes of PSS damaged the trabecular meshwork, which can cause elevation of IOP during the intermission of PSS. Type C: PSS combined with primary open angle glaucoma (POAG). Type D: PSS combined with primary angle-closure glaucoma (PACG). Base on the clinical gateways of GOND classification above, the cases of type A, B, C, and D were 27, 6, 19, and 7 respectively. The staging of visual field damage in cases with GOND from different clinical pathways showed a significant difference (Person chi-square χ2 test, χ2 = 7.211, P = .007). There are at least 4 clinical pathways of GOND in PSS patients, and each clinical pathway corresponds to different clinical features and different treatment principles. It is extremely important to correctly discriminate the pathways of GOND in PSS patients.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Traumatismos do Nervo Óptico , Humanos , Glaucoma de Ângulo Aberto/diagnóstico , Estudos Retrospectivos , Procedimentos Clínicos , Nervo Óptico
5.
Transpl Immunol ; 74: 101673, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35863606

RESUMO

Posner-Schlossman syndrome (PSS) and viral keratitis have a shared pathogen and are common diseases in China, but there are few case reports on whether these two diseases occur concurrently or alternately. After long-term clinical observations, six patients with alternating episodes of PSS and viral keratitis were confirmed at our hospital in the past 10 years. Of the six patients, three were female and three were male. Four patients had monocular PSS with ipsilateral monocular viral keratitis, one had monocular PSS with bilateral viral keratitis, and one had bilateral PSS with bilateral viral keratitis. Of the six cases, three had epithelial viral keratitis and three had endothelial viral keratitis. In four cases, the interval between the onset of the two diseases ranged from 8 days to 3 years, and two cases showed overlapping manifestations of the two diseases in 3 to 6 days, both with incomplete absorption of keratic precipitates. The six cases had intermittent episodes of both diseases and significant loss of corneal sensation during the onset of viral keratitis, and were effectively treated with antiviral therapy. PSS and viral keratitis may alternate episodically, and clinical attention should be paid to these conditions. The mechanism of the alternate episodes might be associated with viral infection and the use of glucocorticoids.


Assuntos
Infecções Oculares Virais , Ceratite , China , Infecções Oculares Virais/tratamento farmacológico , Feminino , Humanos , Ceratite/diagnóstico , Masculino
6.
Medicine (Baltimore) ; 101(25): e29250, 2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35758354

RESUMO

RATIONALE: Femtosecond laser-assisted cataract surgery (FLACS) has grown in popularity among ophthalmologists as a novel surgical technique. However, malignant glaucoma (MG) is a complication of FLACS. Herein, we report a case of MG following FLACS. PATIENT CONCERNS: A 66-year-old woman presented with complaints of blurred vision in the right eye and a foreign body sensation in both eyes. Ophthalmological examinations showed that the corrected distance visual acuity was 20/50 and 20/25 in the right and left eyes, respectively. Without any topical anti-glaucoma medication, the intraocular pressure (IOP) was 20 mmHg in the right eye and 17 mmHg in the left eye. Slit-lamp examination of the right eye revealed a transparent cornea with a defect in the punctate overlying epithelium; the central anterior chamber depth was shallow the peripheral iris laser shot was visible, the pupil was normal, and the lens was mainly cortical opacified. DIAGNOSES: Based on the patient's symptoms, examination results, and preliminary diagnoses, age-related cataract in the right eye, binocular post-antiglaucoma surgery, pseudophakicin in the left eye, and Sjogren syndrome were included. INTERVENTIONS: FLACS was performed to facilitate anterior capsulotomy and segmentation of the nucleus in the right eye. MG occurred after the femtosecond procedure, and with the treatment of medicines combined with phacoemulsification, IOP was eventually normal without further antiglaucoma therapy. OUTCOMES: IOP was 16 mmHg on postoperative day 1. Ocular ultrasonography revealed no choroid detachment or hemorrhage in the right eye. Two weeks postoperatively, uncorrected visual acuity was 20/25, and IOP remained normal with no further antiglaucoma treatment on 1 month postoperatively. CONCLUSIONS: We describe the occurrence of MG after FLACS and illustrate that miosis and bubble formation after FLACS may be risk factors for MG during FLACS.


Assuntos
Extração de Catarata , Catarata , Glaucoma , Terapia a Laser , Facoemulsificação , Idoso , Catarata/complicações , Extração de Catarata/efeitos adversos , Extração de Catarata/métodos , Feminino , Glaucoma/complicações , Glaucoma/cirurgia , Humanos , Terapia a Laser/efeitos adversos , Terapia a Laser/métodos , Lasers , Facoemulsificação/métodos
7.
Medicine (Baltimore) ; 101(49): e32211, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36626461

RESUMO

To determine the distribution of the anterior chamber parameters and associated factors in cataractous adults from middle China. In this cross-sectional study, axial length, anterior chamber depth (ACD) and lens thickness (LT) were measured with IOLMaster 700. The Pentacam HR was designed to measure the anterior chamber volume (ACV) and anterior chamber angle (ACA). Patients' data were collected and analyzed between 2020 and 2022. A total of 157 eyes of 157 Chinese adults (mean age: 64.43 ±â€…12.16 years) with a cataract were enrolled in this study. The mean values measured were as follows: axial length, 24.10 ±â€…2.44mm; ACD, 2.99 ±â€…0.52 mm; LT, 4.51 ±â€…0.48 mm; ACV, 113.98 ±â€…45.12 mm3; ACA, 32.33 ±â€…7.66 degrees. The ACD and ACV were statistically significantly greater in men than in women and had a decrease trend as age and LT increased. In the simulated linear equation of age with ACD and LT the absolute slope coefficients of equations were the same; however, the directions were opposite. The mean ACV was <100 mm3 when the patients were over 60 years. In the multivariate regression analysis of ACD, ACV and ACA there was a reasonable prediction with adjusted R2 = 0.878, 0.847 and 0.564, respectively. This study may provide normative data for cataract patients. The profile of anterior chamber can help improve the knowledge of the risk of angle closure in cataract candidates.


Assuntos
Extração de Catarata , Catarata , Masculino , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Transversais , Câmara Anterior , Catarata/epidemiologia , China/epidemiologia
8.
BMC Ophthalmol ; 21(1): 178, 2021 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-33849464

RESUMO

BACKGROUND: The purpose of this study was to evaluate the ocular biometric parameters in adult cataract patients from China and create an anterior chamber depth (ACD) regression model. METHODS: The ocular biometric records of 28,709 right eyes of cataract surgery candidates who were treated at Aier Eye Hospitals in nine cities from 2018 to 2019 were retrospectively analyzed. All measurements were taken with IOLMaster 700. We included patients who were at least 40 years old and were diagnosed with cataract. RESULTS: The mean age of the patients was 68.6 ± 11.0 years. The mean values recorded were as follows: axial length (AL), 24.17 ± 2.47 mm; mean keratometry (Km) value, 44.26 ± 1.70 D; corneal astigmatism (CA), 1.06 ± 0.96 D; ACD, 3.02 ± 0.45 mm; lens thickness (LT), 4.52 ± 0.45 mm; central corneal thickness (CCT), 0.534 ± 0.04 mm; and white to white (WTW) corneal diameter, 11.64 ± 0.46 mm. ACD correlated positively with AL (Spearman coefficient, 0.544) and WTW (0.300), but negatively with LT (-0.660) and age (-0.285) (all P < 0.01). In the multivariate regression analysis of ACD, which included LT, AL, WTW, sex, Km, CCT, and age, there was a reasonable prediction with adjusted R2 = 0.641. CONCLUSIONS: Cataract patients with longer AL and wider WTW have deeper ACD. With increasing age and lens thickening ACD becomes shallower. Based on the standardized coefficients of ACD multivariate regression analysis from the study, LT is the main factor that affects ACD, and is followed by AL.


Assuntos
Comprimento Axial do Olho , Catarata , Adulto , Idoso , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho/anatomia & histologia , Comprimento Axial do Olho/diagnóstico por imagem , Biometria , China/epidemiologia , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
J Ophthalmol ; 2021: 4717996, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35003790

RESUMO

OBJECTIVE: This study aimed to analyze the distribution of lens thickness (LT) and its associations in age-related cataract patients based on swept-source optical coherence tomography (SS-OCT). METHODS: This cross-sectional study included 59,726 Chinese age-related cataract patients. Only right-eye data were included in the study. Repeated measures of ocular parameters were performed using an IOL Master 700 device. The distributions of ocular biometric data including anterior chamber depth (ACD), LT, axial length (AL), central corneal thickness (CCT), white-to-white (WTW), and mean keratometry (MK) and their associations with age were assessed. The anterior segment (AS) was measured as the sum of CCT, ACD, and LT, while the vitreous chamber depth (VCD) was calculated as the difference between AL and AS. The values of LT : AL, AS : AL, and VCD : AL in different AL groups and their changes are the main outcome measures used to observe the proportion of the anterior and posterior segments of the eye. RESULTS: Biometric data were available for 59,726 individuals. The mean age was 68.81 years (range = 40-100); 40.62% were male and 59.38% were female. Mean anterior chamber depth (ACD) was 3.02 ± 0.44 mm, mean LT was 4.51 ± 0.44 mm, mean axial length (AL) was 23.89 ± 1.92 mm, mean central corneal thickness (CCT) was 0.53 ± 0.03 mm, mean white-to-white (WTW) was 11.64 ± 0.44 mm, and mean keratometry (MK) was 44.27 ± 1.65 diopter. Female patients had shorter AL, shallower ACD, smaller CCT and WTW, decreased LT, and steeper corneas (p < 0.005). ACD revealed the strongest negative correlation (p ≤ 0.001, r = -0.682) with LT. Age (p ≤ 0.001, r = 0.348) showed a moderate positive correlation, whereas MK (p < 0.05, r = 0.011), CCT (p ≤ 0.001, r = 0.041) had a weak positive correlation and WTW (p ≤ 0.001, r = -0.034) had a weak negative correlation with LT. A nonlinear correlation was found between LT and AL. LT increased with age in both males and females. LT changed variably in eyes with AL less than 27 mm, LT decreased as AL increased, then LT gradually increased as AL increased in extremely long and extra-long eyes (p ≤ 0.001). LT : AL and AS : AL decreased as AL increased, VCD : AL gradually increased as AL increased in highly myopic eyes, and VCD : AL increased by about 0.01 for every 1 mm increase in AL. CONCLUSIONS: Among Chinese age-related cataract patients, we found LT to have the strongest relation with ACD. The lens was thicker in elderly patients and women. The correlation between LT and AL is not a simple negative correlation; with the increase of age, LT decreases first and then increases. The proportion of VCD is constantly rising with the elongation of AL.

10.
J Cataract Refract Surg ; 46(12): 1652-1658, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32842077

RESUMO

PURPOSE: To compare corneal astigmatism obtained from an optical coherence tomography-based biometer (OCT) and dual Scheimpflug analyzer (DSA). SETTING: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. DESIGN: Retrospective case series. METHODS: Consecutive cases with both OCT and DSA measurements were reviewed. Three parameters were analyzed with OCT and DSA: (1) standard keratometric astigmatism (K vs simulated keratometry [SimK]), (2) posterior corneal astigmatism, and (3) total corneal astigmatism (total keratometry [TK] vs total corneal power [TCP]). The magnitudes of corneal astigmatism obtained from the 2 devices were compared. Vector analysis was used to assess differences in corneal astigmatism between devices. RESULTS: In this study 530 corneas in 530 patients were measured. Compared with the DSA, the OCT produced a lower mean magnitude of posterior corneal astigmatism (-0.19 vs -0.29 diopter [D]) and a higher percentage of eyes with magnitude ≤0.25 D (75.5% vs 41.9%) (P < .05). Comparing TK and TCP, (1) TK was greater in magnitudes (1.03 vs 0.98 D); (2) 84.3% of eyes had differences in magnitude of ≤0.50 D; (3) in eyes with TK astigmatism ≥0.5 D, 34.5% and 60.1% of eyes had differences in steep meridian of ≤5 degrees and ≤10 degrees, respectively, and (4) 59.2% of eyes had vector differences of ≤0.50 D. In with-the-rule and against-the-rule eyes, respectively, the vector differences between TK and TCP were 0.16 D @ 83 degrees and 0.17 D @ 12 degrees, and in posterior corneal astigmatism, 0.06 D @ 173 degrees; and 0.15 D @ 175 degrees. CONCLUSIONS: There were clinically significant differences in total corneal astigmatism obtained from OCT and DSA devices. Compared with DSA, OCT produced lower values for posterior corneal astigmatism.


Assuntos
Astigmatismo , Tomografia de Coerência Óptica , Astigmatismo/diagnóstico , Córnea/diagnóstico por imagem , Topografia da Córnea , Humanos , Estudos Retrospectivos
11.
J Refract Surg ; 36(8): 536-542, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32785727

RESUMO

PURPOSE: To compare toric intraocular lens (IOL) alignment between femtosecond laser-assisted capsular marking and manual corneal marking. METHODS: This study prospectively included 72 consecutive eyes (from 72 patients) with cataract and anterior corneal astigmatism of 1.00 diopter (D) or greater that underwent femtosecond laser-assisted cataract surgery with implantation of a toric IOL. These eyes were randomly categorized into two groups based on the IOL alignment method. The femtosecond laser capsular marking group included 36 eyes with capsular markers using the latest femtosecond laser platform. The manual marking group included 36 eyes with manual corneal markers. The preservation of the markers was assessed. Visual acuity and refractive outcomes, as well as deviation from the target axis, were evaluated. RESULTS: In the femtosecond laser capsular marking group, all capsular markers were retained for at least 3 months. In the manual marking group, 22.2% of the corneal markers disappeared within 1 month and all markers disappeared within 3 months. At 1 month postoperatively, the mean magnitudes of refractive astigmatism were -0.41 ± 0.26 and -0.45 ± 0.31 D (P = .81), and the uncorrected distance visual acuities were 0.07 ± 0.06 and 0.07 ± 0.05 logMAR (P = .56) in the femtosecond laser capsular marking and manual marking groups, respectively. The misalignment of the toric IOL within 1 hour postoperatively was 1.5° ± 1.4° in the femtosecond laser capsular marking group and 4.4° ± 2.1° in the manual marking group (P < .01). The deviation from the target axis of implantation was 1.6° ± 1.3° in the femtosecond laser capsular group and 4.8° ± 2.5° in the manual marking group (P < .01) at 1 month postoperatively. CONCLUSIONS: IOL misalignment was significantly lower in the femtosecond laser-assisted capsular marking group than in the manual corneal marking group. In addition, the long-term preservation of the capsular marker is helpful in evaluating the rotation of the toric IOL. [J Refract Surg. 2020;36(8):536-542.].


Assuntos
Córnea/anatomia & histologia , Marcadores Fiduciais , Cápsula do Cristalino/anatomia & histologia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Idoso , Astigmatismo/fisiopatologia , Extração de Catarata/métodos , Feminino , Seguimentos , Humanos , Terapia a Laser/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
12.
J Cataract Refract Surg ; 46(4): 534-539, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32271520

RESUMO

PURPOSE: To evaluate the outcome of toric intraocular lens (IOL) implantation in eyes with previous laser in situ keratomileusis/photorefractive keratectomy (LASIK/PRK). SETTING: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. DESIGN: Retrospective case series. METHODS: Consecutive cases that had previous myopic or hyperopic LASIK/PRK and had undergone cataract surgery with toric IOL implantation were retrospectively reviewed. Included were eyes that had (1) preoperative ocular biometry measurements with the Lenstar, (2) no intraoperative or postoperative complications, and (3) available postoperative manifest refraction at ≥3 weeks with corrected distance visual acuity of 20/30 or better. Vector analysis was used to assess the preoperative corneal and postoperative refractive astigmatism. RESULTS: In 56 eyes with previous myopic LASIK/PRK and 19 eyes with previous hyperopic LASIK/PRK, respectively, the mean magnitudes of corneal astigmatism were 1.34 ± 0.62 diopters (D) and 1.66 ± 0.80 D, 5% and 0% of eyes had anterior corneal astigmatism ≤0.50 D, and the centroid values were 0.31 D at 19 degrees ± 1.45 D and 0.74 D at 92 degrees ± 1.72 D preoperatively. Postoperatively, the mean magnitudes of refractive astigmatism were 0.36 ± 0.31 D and 0.34 ± 0.34 D, 80% and 84% of eyes had refractive astigmatism of ≤0.50 D, and the centroid values were 0.12 D at 152 degrees ± 0.46 D and 0.05 D at 172 degrees ± 0.48 D (all P < .05). CONCLUSIONS: Toric IOLs were effective to correct preexisting corneal astigmatism in eyes with previous excimer laser corneal refractive surgery.


Assuntos
Cirurgia da Córnea a Laser , Hiperopia/cirurgia , Implante de Lente Intraocular , Lentes Intraoculares , Miopia/cirurgia , Pseudofacia/fisiopatologia , Idoso , Astigmatismo/fisiopatologia , Biometria , Feminino , Humanos , Hiperopia/fisiopatologia , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer/uso terapêutico , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Facoemulsificação , Ceratectomia Fotorrefrativa , Refração Ocular/fisiologia , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia
13.
Medicine (Baltimore) ; 98(44): e17426, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31689746

RESUMO

RATIONALE: Spherophakia is a rare diagnosis which is often associated with a shallow anterior chamber, angle-closure glaucoma, lens subluxation, and lenticular myopia. When cataracts occur with subluxation of the lens, vision is often markedly affected. This often presents surgeons with a unique challenge of maintaining good visual outcomes while minimizing potential complications. PATIENT CONCERNS: A 48-year-old female was referred for ophthalmological assessment due to decreased vision in the left eye. In the left eye, the best-corrected visual acuity at distance was 20/125 with manifest refraction of -6.5D + (-0.75) D × 118°. The slit lamp examination showed iridodonesis and a significant nuclear cataract (C3N3) with tremor in the left eye. After pupil dilation, a subluxated lens, weak zonules, and "fake golden ring" within the lens was noted. DIAGNOSIS: Due to the patient's symptoms, examination results, she was diagnosed with cataract, subluxation of the lens and spherophakia in left eye. INTERVENTIONS: The patient underwent an uneventful femtosecond laser-assisted cataract surgery (Alcon Fort Worth, TX). The laser was able to perform a circular free-floating anterior capsulotomy and easy lens fragmentation. OUTCOMES: There were no postoperative complications. At 3 months postoperatively, the uncorrected visual acuity was 20/25, and the manifest refraction was -0.25 D - 0.75 D × 148° with the corrected distance visual acuity of 20/16. LESSONS: Femtosecond laser-assisted cataract surgery is an effective approach for cataract surgery in patients with subluxated and spherophakic lenses, with the benefits of causing minimal further zonular damage and easy lens fragmentation.


Assuntos
Extração de Catarata/métodos , Catarata/complicações , Terapia a Laser/métodos , Subluxação do Cristalino/complicações , Cristalino/fisiologia , Feminino , Humanos , Pessoa de Meia-Idade , Acuidade Visual
14.
Ophthalmology ; 126(5): 663-670, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30605743

RESUMO

PURPOSE: To investigate the difference between the segmented axial length (AL) and the displayed AL on an optical low-coherence reflectometry (OLCR) biometer and to compare the refractive prediction errors calculated using the segmented and displayed ALs. DESIGN: Retrospective case series. PARTICIPANTS: Four thousand nine hundred ninety-two eyes from 4992 patients in the theoretical study and 1758 eyes from 1758 patients in the refractive prediction error comparison. METHODS: First, we calculated the segmented AL as the sum of geometrical ocular segments converted from the optical path length (OPL) in each medium. To convert the OPL to a geometrical distance in each medium, we used 4 sets of group refractive indices. Then, the mean absolute prediction error (MAE) was calculated with the displayed AL and segmented AL using 6 intraocular lens power formulas: Olsen, Barrett Universal II (Barrett), Haigis, Hoffer Q, Holladay 1, and Sanders-Retzlaff-Kraff trial (SRK/T). MAIN OUTCOME MEASURES: Segmented AL, difference in AL (segmented AL minus displayed AL), MAE, and percentage of eyes within 0.5 diopter (D) of error. RESULTS: The segmented ALs were up to 0.29 mm longer in short eyes and 0.50 mm shorter in long eyes. The differences in ALs were correlated negatively with the displayed ALs (r values, -0.941 to -0.913; P < 0.001). The MAEs were significantly lower using segmented ALs for all formulas except the Olsen in both the entire group and the long eye subgroup (AL, ≥26 mm) and for the Holladay 1 and Hoffer Q in the short eye subgroup (AL, ≤ 22 mm). Use of segmented ALs produced a greater percentage of eyes within 0.5 D of error for all formulas except the Olsen and Haigis for the entire group, for long eyes, and for the Holladay 1 in short eyes. CONCLUSIONS: The segmented ALs were longer in short eyes and shorter in long eyes compared with the displayed ALs calculated with a single group refractive index for the entire eye. The refractive accuracy with segmented ALs was improved in short eyes with the Hoffer Q and Holladay 1 formulas and in long eyes with all formulas except the Olsen formula.


Assuntos
Comprimento Axial do Olho/diagnóstico por imagem , Biometria/métodos , Modelos Teóricos , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Acuidade Visual , Idoso , Extração de Catarata , Feminino , Humanos , Lentes Intraoculares , Masculino , Período Pós-Operatório , Erros de Refração/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
Gene ; 689: 51-55, 2019 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-30552983

RESUMO

AIMS: To diagnose a Chinese family with inherited ectopia lentis in a genetic method and analyze the genotype-phenotype correlation. METHODS: The phenotype of each family member was identified by detailed clinical examination. We used targeted next generation sequencing (NGS) to identify mutations in FBN1 in an efficient and accurate way. The mutation in FBN1 was confirmed in all affected family members by Sanger sequencing. RESULTS: A novel mutation c.385T>C (p.C129R) in FBN1 was identified in the proband by targeted NGS. The mutation was segregated in all affected family members and contributes to specific disease phenotypes. The same mutation was not found in other unaffected relatives and a 100 normal random population by Sanger sequencing. CONCLUSIONS: Our study reports a novel mutation in FBN1 in a Chinese family and to diagnose this family as Marfan syndrome, we also expand the genotype-phenotype correlation of this disease.


Assuntos
Análise Mutacional de DNA/métodos , Ectopia do Cristalino/genética , Fibrilina-1/genética , Sequenciamento de Nucleotídeos em Larga Escala , Síndrome de Marfan/genética , Mutação de Sentido Incorreto , Adolescente , Adulto , Povo Asiático , Criança , China , Ectopia do Cristalino/complicações , Família , Feminino , Estudos de Associação Genética , Humanos , Masculino , Síndrome de Marfan/complicações , Pessoa de Meia-Idade , Linhagem
16.
PLoS One ; 12(10): e0186522, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29073156

RESUMO

PURPOSE: To compare the clinical performance between trifocal and bifocal intraocular lenses in bilateral cataract and/or refractive lens exchange (RLE) surgery. METHODS: A comprehensive literature search of PubMed, EMBASE, Cochrane Controlled Trials Register and Web of Science was performed through October 2016 to identify randomized, controlled trials (RCTs) and comparative cohort studies. The primary outcomes were uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), defocus curve, spectacle independence, patient satisfaction and contrast sensitivity. The secondary outcomes were residual sphere, spherical equivalent (SE), cylinder and complications. RESULTS: Six RCTs and 2 cohort studies including 568 eyes (278 in the trifocal group and 290 in the bifocal group) were identified. There was a statically significant difference between the two groups in UDVA (WMD: -0.03, 95% CI: -0.05 to -0.01, P = 0.005), but the difference (0.03 log MAR) is not clinically significant. Intermediate visual acuity was better in the trifocal IOL group judging from UIVA and defocus curves. There was a statically significant difference between the two groups in residual cylinder (WMD: 0.11, 95% CI: 0.02 to 0.20, P = 0.02), and subgroup AT Lisa tri 839MP trifocal also showed significant better UNVA than bifocal IOLs (WMD: -0.13, 95% CI: -0.17 to -0.08, P<0.00001). However, no significant differences were observed in UNVA (WMD: -0.04, 95% CI: -0.11 to 0.02, P = 0.19), spectacle independence (WMD: 1.27, 95% CI: 0.89 to 18.15, P = 0.07), patient satisfaction (WMD: 4.01, 95% CI: 0.07 to 22.72, P = 0.87), residual sphere (WMD: -0.03, 95% CI: -0.18 to 0.13, P = 0.74), SE (WMD: 0.04, 95% CI: -0.09 to 0.16, P = 0.55) or complications (WMD: 2.08, 95% CI: 0.35 to 12.43, P = 0.42). CONCLUSIONS: Trifocal IOL technology (especially AT Lisa trifocal 839M trifocal) had a clear advantage over bifocal IOLs in intermediate visual acuity, while both trifocal IOLs and bifocal IOLs showed excellent performance in distance visual acuity. AT Lisa trifocal 839M trifocal could provide better uncorrected near visual acuity than bifocal IOLs. However, more evidence is needed to compare their spectacle independence, higher satisfaction rate, and photic phenomena.


Assuntos
Lentes Intraoculares , Extração de Catarata , Sensibilidades de Contraste , Humanos , Implante de Lente Intraocular , Satisfação do Paciente , Complicações Pós-Operatórias , Acuidade Visual
17.
BMC Ophthalmol ; 17(1): 100, 2017 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-28646864

RESUMO

BACKGROUND: Cataract surgery after penetratingkeratoplasty (PKP) is often challenging due to changes in the integrity of the cornea caused by PKP. For example, corneal endothelial cell (CEC) loss and corneal edema commonly occur after traditional phacoemulsification cataract surgery in patients that previously had successful PKP. Recent studies have reported that femtosecond laser-assisted cataract surgery (FLACS) significantly reduces the need for ultrasound energy minimizing mechanical damage to the cornea and results in a reduction of CEC loss and corneal edema. CASE PRESENTATION: We report a case in which FLACS was used in a patient with previous PKP. CONCLUSION: This case supports the suggestion that the use of the femtosecond laser improves the surgical outcome of cataract surgery after PKP. This improvement may be result of the precise incision, controlled capsulorhexis, and reduced lens fragmentation experienced with the femtosecond laser which helps to reduce potential complications of cataract surgery after PKP.


Assuntos
Extração de Catarata/métodos , Catarata/complicações , Doenças da Córnea/cirurgia , Ceratoplastia Penetrante/métodos , Terapia a Laser/métodos , Acuidade Visual , Catarata/diagnóstico , Doenças da Córnea/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica
18.
Zhonghua Yan Ke Za Zhi ; 51(9): 689-93, 2015 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-26693655

RESUMO

OBJECTIVE: To evaluate the clinical outcome of the femtosecond laser-assisted cataract surgery (FLACS) in our first 300 cases. METHODS: In this retrospective study, the study group comprised 300 cases (300 eyes) in which FLACS was done. The control group comprised 300 cases (300 eyes) in which phacoemulsification was performed. The steps of the FLACS included capsulotomy, lens fragmentation, corneal incisions, and creation of incisions within the peripheral cornea to aid the correction of pre-existing astigmatism. After the FLACS, 2.2-mm coaxial micro-incision phacoemulsification and implantation of an intraocular lens were operated. The preoperative best corrected visual acuity (BCVA) and postoperative uncorrected visual acuity (UCVA), the cumulative dissipated energy (CDE) of the phacoemulsification, and the parameters of the FLACS, including the docking time, the suction time and the laser time, were recorded. The complications of the FLACS were analyzed. RESULTS: The FLACS was successfully completed in 99.33% of the cases. The docking time was (24.6 ± 16.8) sec, the suction time was (101.27 ± 20.09) sec, and the laser time was (23.3 ± 5.5) sec. The most common complications of the FLACS included suction break (7/300, 2.33%), subconjunctival hemorrhage (58/300, 19.33%), pupillary constriction (47/300, 15.67%), incision at a wrong site (13/300, 4.33%), anterior capsular tag (17/300, 5.67%), decentration of the capsulorhexis (11/300, 3.67%), failure to split the lens nucleus (5/300, 1.67%), and posterior capsular ruptures (1/300, 0.33%). The CDE was 5.52 ± 5.18 in the FLACS group and 8.37 ± 7.91 in the traditional phaco group (P < 0.05). The UCVA was 0.12 ± 0.08 and 0.13 ± 0.11 at 1 month after the FLACS and traditional phaco, respectively (P > 0.05). CONCLUSIONS: Compared with the conventional phacoemulsification surgery, the FLACS can achieve less CDE and better early postoperative visual acuity. Long-term effects remain to be investigated.


Assuntos
Extração de Catarata/métodos , Astigmatismo , Capsulorrexe , Catarata , Humanos , Lasers , Implante de Lente Intraocular , Cristalino , Lentes Intraoculares , Facoemulsificação , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual
19.
Cardiovasc Ultrasound ; 12: 17, 2014 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-24885095

RESUMO

OBJECTIVES: To clarify the time-course changes in left ventricular myocardial deformation using velocity vector imaging and to provide insights into our understanding of the cardiac pathophysiology in diabetes mellitus. METHODS: Thirty New Zealand white rabbits were randomly divided into either the control group (n = 10) or the diabetes mellitus (DM) group (induced with STZ, n = 20). For the myocardial deformation studies, echocardiography and syngo-vector velocity imaging (VVI) were performed at baseline and after 2, 4, 8, and 12 weeks in all of the rabbits. The left ventricular (LV) global longitudinal and circumferential strain and strain rate were measured. For histomorphological study of the heart structure, 2 of the STZ-induced rabbits were killed at 2, 4, 8, and 12 weeks. Routine hematoxylin and eosin staining was performed. RESULTS: At 2 weeks, the global longitudinal strain (GLS), systolic strain rate (GLSRs), and diastolic strain rate (GLSRd) were significantly lower in the DM group compared with the control group (-18.16% versus -24.00%, -1.86 s(-1) versus -2.49 s(-1), 1.93 s(-1) versus 2.42 s(-1), respectively, P < 0.05), while, compared with the control group, the global circumferential strain (GCS), systolic strain rate (GCSRs), and diastolic strain rate (GCSRd) in the DM group were significantly decreased (-12.77% versus -23.31%, -1.31 s(-1) versus -2.20 s(-1), 1.41 s(-1) versus 2.15 s(-1), respectively, P < 0.05) at 8 weeks. With the progression of untreated diabetes, the histoanatomical alterations intensified gradually beginning at 2 weeks. CONCLUSIONS: The progressive impairments in LV myocardial deformation and structure occurred early in diabetic rabbits with normal LV ejection fraction (EF), FS, and E/A. VVI could be used to evaluate subtle cardiac dysfunction in the early phase of DM.


Assuntos
Diabetes Mellitus Experimental/complicações , Cardiomiopatias Diabéticas/diagnóstico por imagem , Ecocardiografia/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Animais , Diabetes Mellitus Experimental/fisiopatologia , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/fisiopatologia , Cardiomiopatias Diabéticas/fisiopatologia , Diástole/fisiologia , Modelos Animais de Doenças , Ecocardiografia/estatística & dados numéricos , Variações Dependentes do Observador , Coelhos , Distribuição Aleatória , Sístole/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia
20.
Echocardiography ; 26(2): 163-70, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19054025

RESUMO

OBJECTIVE: To assess the left ventricular (LV) longitudinal systolic and diastolic function in patients with dilated cardiomyopathy (DCM) by syngo Velocity Vector Imaging (VVI). METHODS: Digital dynamic images of 30 DCM patients and 30 healthy subjects were collected; then the longitudinal velocity, strain, and strain rate were measured in systolic early and late diastolic periods, and the time to peak systolic velocity, strain, and strain rate were measured and recorded. The parameters of the two groups were compared. RESULTS: All of the parameters of the DCM were significantly lower than those of the normal group (P < 0.05-0.01), except that the parameter of late diastolic strain was not different between the two groups (P > 0.05). CONCLUSIONS: VVI is a novel noninvasive tool to assess quantitatively and objectively LV regional systolic and diastolic function in patients with DCM; it provides another useful modality for evaluating cardiac function.


Assuntos
Cardiomiopatia Dilatada/diagnóstico , Vetorcardiografia/métodos , Disfunção Ventricular Esquerda/diagnóstico , Volume Cardíaco , Cardiomiopatia Dilatada/complicações , Ecocardiografia Doppler/métodos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA