Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; 70(5): 1673-1682, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37079397

RESUMO

Due to prolonged incorrect sitting posture, upper body musculoskeletal disorders (UBMDs) are largely widespread among sedentary workers. Monitoring employees' sitting behaviors could be of great help in minimizing UBMDs' occurrence. In addition, being primarily influenced by psycho-physical stress conditions, respiratory rate (RR) would be a further useful parameter to delineate the workers' state of health. Wearable systems have emerged as a viable option for sitting posture and RR monitoring since enable continuous data collecting with no posture disturbances. Nevertheless, the main limits are poor fit, cumbersomeness, and movement restriction resulting in discomfort for the user. In addition, only few wearable solutions can track both these parameters contextually. To address these problems, in this study a flexible wearable system composed of seven modular sensing elements based on fiber Bragg grating (FBG) technology and designed to be worn on the back has been proposed to recognize the most common sitting postures (i.e., kyphotic, upright and lordotic) and estimate RR. The assessment was performed on ten volunteers showing good performances in postures recognition via Naïve Bayes classificator (accuracy >96.9%) and agreement with the benchmark in RR estimation (MAPE ranging between 0.74% and 3.83%, MODs close to zero, and LOAs between 0.76 bpm and 3.63 bpm). The method was then successfully tested on three additional subjects under different breathing conditions. The wearable system could offer great support for a better understanding of the workers' posture attitudes and contribute to gathering RR information to depict an overall picture of the users' state of health.


Assuntos
Postura Sentada , Dispositivos Eletrônicos Vestíveis , Humanos , Taxa Respiratória , Teorema de Bayes , Postura
2.
Artigo em Inglês | MEDLINE | ID: mdl-36294108

RESUMO

Respiratory diseases are common in post-stroke hemiplegic patients and represent a major social problem as they worsen the quality of life and reduce the life span. As a consequence, being able to monitor respiratory parameters such as the respiratory rate (RR) and assess the presence of respiratory asynchronies could be of paramount importance to define hemiplegics' health status. Moreover, RR is a useful parameter to investigate the level of fatigue and distress that these patients undergo during rehabilitation processes. Although motion capture systems and flowmeters are the leading instruments for respiratory pattern evaluation, smart wearable systems are gaining ever more acceptance since they allow continuous monitoring by detecting chest wall breathing displacements, ensuring reduced costs and no need for dedicated spaces. Among other sensing technologies, fiber Bragg grating (FBG) sensors have emerged thanks to their high sensitivity to strain, lightness, and multiplexing capability. In this work, a wearable system composed of four flexible dumbbell-shaped sensing modules is proposed for respiratory monitoring in hemiplegic patients. The system is light and easy to wear and can be adapted to any anthropometry thanks to the modular anchoring system. Its feasibility assessment in RR evaluation was performed on seven hemiplegic volunteers in eupnea and tachypnea breathing conditions. In addition, an explorative investigation was conducted to assess the system's ability to detect asynchronies between torso compartments. The good results suggest that this device could be a useful instrument to support clinicians and operators in hemiplegic patients' management.


Assuntos
Qualidade de Vida , Dispositivos Eletrônicos Vestíveis , Humanos , Hemiplegia , Monitorização Fisiológica/métodos , Taxa Respiratória
3.
Sensors (Basel) ; 22(4)2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35214287

RESUMO

In this study, a novel wearable system for the identification of compensatory trunk movements (CTMs) in post-stroke hemiplegic patients is presented. The device is composed of seven soft sensing elements (SSEs) based on fiber Bragg grating (FBG) technology. Each SSE consists of a single FBG encapsulated into a flexible matrix to enhance the sensor's robustness and improve its compliance with the human body. The FBG's small size, light weight, multiplexing capability, and biocompatibility make the proposed wearable system suitable for multi-point measurements without any movement restriction. Firstly, its manufacturing process is presented, together with the SSEs' mechanical characterization to strain. Results of the metrological characterization showed a linear response of each SSE in the operating range. Then, the feasibility assessment of the proposed system is described. In particular, the device's capability of detecting CTMs was assessed on 10 healthy volunteers and eight hemiplegic patients while performing three tasks which are representative of typical everyday life actions. The wearable system showed good potential in detecting CTMs. This promising result may foster the use of the proposed device on post-stroke patients, aiming at assessing the proper course of the rehabilitation process both in clinical and domestic settings. Moreover, its use may aid in defining tailored strategies to improve post-stoke patients' motor recovery and quality of life.


Assuntos
Qualidade de Vida , Dispositivos Eletrônicos Vestíveis , Hemiplegia , Humanos , Movimento/fisiologia , Tronco/fisiologia
4.
Sensors (Basel) ; 21(19)2021 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-34640649

RESUMO

Plants are primary resources for oxygen and foods whose production is fundamental for our life. However, diseases and pests may interfere with plant growth and cause a significant reduction of both the quality and quantity of agriculture products. Increasing agricultural productivity is crucial for poverty reduction and food security improvements. For this reason, the 2030 Agenda for Sustainable Development gives a central role to agriculture by promoting a strong technological innovation for advancing sustainable practices at the plant level. To accomplish this aim, recently, wearable sensors and flexible electronics have been extended from humans to plants for measuring elongation, microclimate, and stressing factors that may affect the plant's healthy growth. Unexpectedly, fiber Bragg gratings (FBGs), which are very popular in health monitoring applications ranging from civil infrastructures to the human body, are still overlooked for the agriculture sector. In this work, for the first time, plant wearables based on FBG technology are proposed for the continuous and simultaneous monitoring of plant growth and environmental parameters (i.e., temperature and humidity) in real settings. The promising results demonstrated the feasibility of FBG-based sensors to work in real situations by holding the promise to advance continuous and accurate plant health growth monitoring techniques.


Assuntos
Microclima , Dispositivos Eletrônicos Vestíveis , Agricultura , Humanos , Plantas , Tecnologia
5.
Sensors (Basel) ; 21(10)2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-34065838

RESUMO

In this work, we report novel relative humidity sensors realized by functionalising fibre Bragg gratings with chitosan, a moisture-sensitive biopolymer never used before for this kind of fibre optic sensor. The swelling capacity of chitosan is fundamental to the sensing mechanism. Different samples were fabricated, testing the influence of coating design and deposition procedure on sensor performance. The sensitivity of the sensors was measured in an airtight humidity-controlled chamber using saturated chemical salt solutions. The best result in terms of sensitivity was obtained for a sensor produced on filter paper substrate. Tests for each design were performed in the environment, lasted several days, and all designs were independently re-tested at different seasons of the year. The produced sensors closely followed the ambient humidity variation common to the 24-h circadian cycle.

6.
Sensors (Basel) ; 20(21)2020 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-33114180

RESUMO

Grasping is one of the first dominant motor behaviors that enable interaction of a newborn infant with its surroundings. Although atypical grasping patterns are considered predictive of neuromotor disorders and injuries, their clinical assessment suffers from examiner subjectivity, and the neuropathophysiology is poorly understood. Therefore, the combination of technology with functional magnetic resonance imaging (fMRI) may help to precisely map the brain activity associated with grasping and thus provide important insights into how functional outcomes can be improved following cerebral injury. This work introduces an MR-compatible device (i.e., smart graspable device (SGD)) for detecting grasping actions in newborn infants. Electromagnetic interference immunity (EMI) is achieved using a fiber Bragg grating sensor. Its biocompatibility and absence of electrical signals propagating through the fiber make the safety profile of the SGD particularly favorable for use with fragile infants. Firstly, the SGD design, fabrication, and metrological characterization are described, followed by preliminary assessments on a preterm newborn infant and an adult during an fMRI experiment. The results demonstrate that the combination of the SGD and fMRI can safely and precisely identify the brain activity associated with grasping behavior, which may enable early diagnosis of motor impairment and help guide tailored rehabilitation programs.


Assuntos
Força da Mão , Imageamento por Ressonância Magnética , Adulto , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Materiais Inteligentes
7.
Sensors (Basel) ; 20(8)2020 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-32344520

RESUMO

In this editorial on the special issue "Fibre Optic Sensors for Structural and Geotechnical Monitoring" a review of the contribution papers selected for publication is given. Each paper is briefly summarized, presenting its objective and methods, then a comment is given about the relevance of the work with respect to the advance and the spreading of the fibre optic technology for monitoring applications.

8.
Sensors (Basel) ; 19(18)2019 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-31487885

RESUMO

Use of fiber Bragg gratings (FBGs) to monitor high temperature (HT) applications is of great interest to the research community. Standard commercial FBGs can operate up to 600 ∘ C. For applications beyond that value, specific processing of the FBGs must be adopted to allow the grating not to deteriorate. The most common technique used to process FBGs for HT applications is the regeneration procedure (RP), which typically extends their use up to 1000 ∘ C. RP involves a long-term annealing of the FBGs, to be done at a temperature ranging from 550 to 950 ∘ C. As at that temperature, the original coating of the FBGs would burn out, they shall stay uncoated, and their brittleness is a serious concern to deal with. Depositing a metal coating on the FBGs prior to process them for RP offers an effective solution to provide them with the necessary mechanical strengthening. In this paper, a procedure to provide the FBG with a bimetallic coating made by copper and nickel electrodeposition (ED) is proposed, discussing issues related to the coating morphology, adherence to the fiber, and effects on the grating spectral response. To define the processing parameters of the proposed procedure, production tests were performed on dummy samples which were used for destructive SEM-EDS analysis. As a critical step, the proposed procedure was shown to necessitate a heat treatment after the nickel ED, to remove the absorbed hydrogen. The spectral response of the FBG samples was monitored along the various steps of the proposed procedure and, as a final proof test for adherence stability of the bimetallic coating, along a heating/cooling cycle from room temperature to 1010 ∘ C. The results suggest that, given the emergence of Kirkendall voids at the copper-nickel interface, occurring at the highest temperatures (700-1010 ∘ C), the bimetallic layer could be employed as FBG coating up to 700 ∘ C.

9.
Sensors (Basel) ; 19(16)2019 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-31426480

RESUMO

In precision sports, the control of breathing and heart rate is crucial to help the body to remain stable in the shooting position. To improve stability, archers try to adopt similar breathing patterns and to have a low heartbeat during each shot. We proposed an easy-to-use and unobtrusive smart textile (ST) which is able to detect chest wall excursions due to breathing and heart beating. The sensing part is based on two FBGs housed into a soft polymer matrix to optimize the adherence to the chest wall and the system robustness. The ST was assessed on volunteers to figure out its performance in the estimation of respiratory frequency (fR) and heart rate (HR). Then, the system was tested on two archers during four shooting sessions. This is the first study to monitor cardio-respiratory activity on archers during shooting. The good performance of the ST is supported by the low mean absolute percentage error for fR and HR estimation (≤1.97% and ≤5.74%, respectively), calculated with respect to reference signals (flow sensor for fR, photopletismography sensor for HR). Moreover, results showed the capability of the ST to estimate fR and HR during different phases of shooting action. The promising results motivate future investigations to speculate about the influence of fR and HR on archers' performance.


Assuntos
Frequência Cardíaca/fisiologia , Monitorização Fisiológica/métodos , Adulto , Feminino , Humanos , Masculino , Respiração , Esportes , Dispositivos Eletrônicos Vestíveis , Adulto Jovem
10.
Biomed Opt Express ; 9(12): 5891-5902, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31065401

RESUMO

Temperature mapping is a key asset in supporting the clinician during thermal ablation (TA) treatment of tumors without adding additional risk to the TA procedure. Herein we report our experiments on multidimensional thermal mapping during radio frequency (RF) thermal ablation treatments of an ex-vivo animal organ. The temperature was monitored using several arrays of fiber Bragg gratings properly positioned around the RF applicator. The results show the effectiveness of our proposed method at assessing the TA probe depth and demonstrating how the insertion depth directly influences the maximum temperature and the treated area of the radio frequency ablation.

11.
IEEE Trans Biomed Eng ; 59(10): 2958-64, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22929361

RESUMO

Laser-induced interstitial thermotherapy (LITT) has been recently applied to pancreas in animal models for ablation purpose. Assessment of thermal effects due to the laser-pancreatic tissue interaction is a critical factor in validating the procedure feasibility and safety. A mathematical model based on bioheat equation and its experimental assessment was developed. The LITT procedure was performed on 40 ex vivo porcine pancreases, with an Nd:YAG (1064 nm) energy of 1000 J and power from 1.5 up to 10 W conveyed by a quartz optical fiber with 300 µm diameter. Six fiber Bragg grating sensors have been utilized to measure temperature distribution as a function of time at fixed distances from the applicator tip within pancreas undergoing LITT. Simulations and experiments show temperature variations Δ T steeply decreasing with distance from the applicator at higher power values: at 6 W, ∆T > 40 °C at 5 mm and Δ T is approximately equal to 5 °C at 10 mm. Δ T nonlinearly increases with power close to the applicator. Ablated and coagulated tissue volumes have also been measured and experimental results agree with theoretical ones. Despite the absence of data in the current literature on pancreas optical parameters, the model allowed a quite good prediction of thermal effects. The prediction of LITT effects on pancreas is necessary to assess laser dosimetry.


Assuntos
Hipertermia Induzida/métodos , Lasers de Estado Sólido , Modelos Biológicos , Pâncreas/patologia , Pâncreas/efeitos da radiação , Animais , Simulação por Computador , Histocitoquímica , Hipertermia Induzida/efeitos adversos , Hipertermia Induzida/instrumentação , Suínos , Temperatura , Termometria/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA