Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ann Thorac Surg ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38750686

RESUMO

BACKGROUND: The aim of this study was to report the long-term results of the clover and edge-to-edge repair techniques for complex tricuspid regurgitation (TR). METHODS: This was a single-center observational study. A competing risks proportional-hazards regression model, using the Fine and Gray model, was performed to analyze the time to TR ≥2+, considering death as a competing risk. RESULTS: A total of 145 consecutive patients (57% female) with severe or moderately severe TR secondary to leaflet prolapse or flail (115 patients), tethering (27 patients), or mixed (3 patients) lesions underwent clover (110 patients) or edge-to-edge repair(35 patients). The TR origin was degenerative in 75% of cases, posttraumatic in 8%, and secondary to dilated cardiomyopathy in 17%. Ring (64%) or suture (31%) annuloplasty was performed in 95% of patients. Concomitant procedures (mainly mitral surgery) were performed in 80% of cases. Hospital death was 5.5%. Follow-up was 98% complete, and median was 15 years (interquartile range, 14-17 years). The 16-year overall survival was 56% ± 5%. Previous cardiac surgery (hazard ratio [HR], 2.83; 95% CI, 1.15-6.93; P = .023) and right ventricular dysfunction (HR, 2.24; 95% CI, 1.01-4.95; P = .046) were identified as predictors of death. The 16-year cumulative incidence function (CIF) of cardiac death with noncardiac death as a competing risk was 19.6%, and previous cardiac surgery (HR, 3.44; 95% CI, 1.23-9.65; P = .019) was detected as the only predictor of the event. At 16 years, the CIF of TR ≥2+ with death as a competing risk was 23.8%. In particular, TR ≥3+ was detected in 4 patients (3%). CONCLUSIONS: When TR could not be treated by annuloplasty alone, concomitant leaflet repair with the clover or edge-to-edge technique effectively restored valve competence with very satisfactory long-term results and a low rate of moderate or greater TR recurrence.

2.
Life (Basel) ; 14(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38672728

RESUMO

(1) Background: Systemic inflammation stands as a well-established risk factor for ischemic cardiovascular disease, as well as a contributing factor in the development of cardiac arrhythmias, notably atrial fibrillation. Furthermore, scientific studies have brought to light the pivotal role of localized vascular inflammation in the initiation, progression, and destabilization of coronary atherosclerotic disease. (2) Methods: We comprehensively review recent, yet robust, scientific evidence elucidating the use of perivascular adipose tissue attenuation measurement on computed tomography applied to key anatomical sites. Specifically, the investigation extends to the internal carotid artery, aorta, left atrium, and coronary arteries. (3) Conclusions: The examination of perivascular adipose tissue attenuation emerges as a non-invasive and indirect means of estimating localized perivascular inflammation. This measure is quantified in Hounsfield units, indicative of the inflammatory response elicited by dense adipose tissue near the vessel or the atrium. Particularly noteworthy is its potential utility in assessing inflammatory processes within the coronary arteries, evaluating coronary microvascular dysfunction, appraising conditions within the aorta and carotid arteries, and discerning inflammatory states within the atria, especially in patients with atrial fibrillation. The widespread applicability of perivascular adipose tissue attenuation measurement underscores its significance as a diagnostic tool with considerable potential for enhancing our understanding and management of cardiovascular diseases.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38546963

RESUMO

Pentraxin 3 (PTX3) is an acute phase protein produced in various tissues in response to microbial and sterile stimuli, which regulates the inflammation outcomes. PTX3 has not been investigated in myocarditis. Our aim was to assess circulating and cardiac tissue expression of PTX3 in 55 patients with myocarditis proven by magnetic resonance and/or endomyocardial biopsy. A major proportion of patients with myocarditis displayed significantly increased plasma PTX3 levels as compared with controls (26/30 vs. 0/10), with higher diagnostic yield than conventional biomarkers in the study group. Cardiac tissue analysis revealed PTX3 expression in all patients (40/40), with viral myocarditis exhibiting higher signal intensity than autoimmune myocarditis, and with a predominant localization in cardiomyocytes. Abnormal plasma PTX3 was associated with systolic dysfunction and heart failure at presentation. Interestingly, patients who recovered by 12 months had higher baseline PTX3 levels. Our preliminary data support the potential use of PTX3 as a biomarker in myocarditis.

4.
J Clin Med ; 13(1)2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38202159

RESUMO

BACKGROUND: Infective endocarditis (IE) is a serious disease, and in many cases, surgery is necessary. Whether the type of prosthesis implanted for aortic valve replacement (AVR) for IE impacts patient survival is a matter of debate. The aim of the present study is to quantify differences in long-term survival and recurrence of endocarditis AVR for IE according to prosthesis type among patients aged 40 to 65 years. METHODS: This was an analysis of the INFECT-REGISTRY. Trends in proportion to the use of mechanical prostheses versus biological ones over time were tested by applying the sieve bootstrapped t-test. Confounders were adjusted using the optimal full-matching propensity score. The difference in overall survival was compared using the Cox model, whereas the differences in recurrence of endocarditis were evaluated using the Gray test. RESULTS: Overall, 4365 patients were diagnosed and operated on for IE from 2000 to 2021. Of these, 549, aged between 40 and 65 years, underwent AVR. A total of 268 (48.8%) received mechanical prostheses, and 281 (51.2%) received biological ones. A significant trend in the reduction of implantation of mechanical vs. biological prostheses was observed during the study period (p < 0.0001). Long-term survival was significantly higher among patients receiving a mechanical prosthesis than those receiving a biological prosthesis (hazard ratio [HR] 0.546, 95% CI: 0.322-0.926, p = 0.025). Mechanical prostheses were associated with significantly less recurrent endocarditis after AVR than biological prostheses (HR 0.268, 95%CI: 0.077-0.933, p = 0.039). CONCLUSIONS: The present analysis of the INFECT-REGISTRY shows increased survival and reduced recurrence of endocarditis after a mechanical aortic valve prosthesis implant for IE in middle-aged patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA