Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 12(5): 6752-6760, 2020 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-31927947

RESUMO

The magnetoelectric properties of exchange-coupled Ni/CoFeB-based composite multiferroic microstructures are investigated. The strength and sign of the magnetoelastic effect are found to be strongly correlated with the ratio between the thicknesses of two magnetostrictive materials. In cases where the thickness ratio deviates significantly from one, the magnetoelastic behavior of the multiferroic microstructures is dominated by the thicker layer, which contributes more strongly to the observed magnetoelastic effect. More symmetric structures with a thickness ratio equal to one show an emergent interfacial behavior which cannot be accounted for simply by summing up the magnetoelastic effects occurring in the two constituent layers. This aspect is clearly visible in the case of ultrathin bilayers, where the exchange coupling drastically affects the magnetic behavior of the Ni layer, making the Ni/CoFeB bilayer a promising next-generation synthetic magnetic system entirely. This study demonstrates the richness and high tunability of composite multiferroic systems based on coupled magnetic bilayers compared to their single magnetic layer counterparts. Furthermore, because of the compatibility of CoFeB with present magnetic tunnel junction-based spintronic technologies, the reported findings are expected to be of great interest for the development of ultralow-power magnetoelectric memory devices.

2.
Phys Rev B ; 93(6)2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27882359

RESUMO

We present measurements of the exchange stiffness D and the exchange constant A of a sputtered 80 nm Tb0.3Dy0.7Fe2 film. Using a broadband ferromagnetic resonance setup in a wide frequency range from 10 GHz to 50 GHz, multiple perpendicular standing spin-wave resonances were observed with the external static magnetic field applied in-plane. The field corresponding to the strongest resonance peak at each frequency is used to determine the effective magnetization, the g-factor and the Gilbert damping. Furthermore, the dependence of spin-wave mode on field-position is observed for several frequencies. The analysis of spin-wave resonance spectra at multiple frequencies allows precise determination of the exchange stiffness D = (2.79 ± 0.02) × 10-17 T · m2 for an 80 nm thick film. From this value, we calculated the exchange constant A = (9.1 ± 0.1) pJ · m-1.

3.
Nanotechnology ; 27(43): 43LT01, 2016 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-27655294

RESUMO

Nanomagnetic logic has emerged as a potential replacement for traditional Complementary Metal Oxide Semiconductor (CMOS) based logic because of superior energy-efficiency (Salahuddin and Datta 2007 Appl. Phys. Lett. 90 093503, Cowburn and Welland 2000 Science 287 1466-68). One implementation of nanomagnetic logic employs shape-anisotropic (e.g. elliptical) ferromagnets (with two stable magnetization orientations) as binary switches that rely on dipole-dipole interaction to communicate binary information (Cowburn and Welland 2000 Science 287 1466-8, Csaba et al 2002 IEEE Trans. Nanotechnol. 1 209-13, Carlton et al 2008 Nano Lett. 8 4173-8, Atulasimha and Bandyopadhyay 2010 Appl. Phys. Lett. 97 173105, Roy et al 2011 Appl. Phys. Lett. 99 063108, Fashami et al 2011 Nanotechnology 22 155201, Tiercelin et al 2011 Appl. Phys. Lett. 99 , Alam et al 2010 IEEE Trans. Nanotechnol. 9 348-51 and Bhowmik et al 2013 Nat. Nanotechnol. 9 59-63). Normally, circular nanomagnets are incompatible with this approach since they lack distinct stable in-plane magnetization orientations to encode bits. However, circular magnetoelastic nanomagnets can be made bi-stable with a voltage induced anisotropic strain, which provides two significant advantages for nanomagnetic logic applications. First, the shape-anisotropy energy barrier is eliminated which reduces the amount of energy required to reorient the magnetization. Second, the in-plane size can be reduced (∼20 nm) which was previously not possible due to thermal stability issues. In circular magnetoelastic nanomagnets, a voltage induced strain stabilizes the magnetization even at this size overcoming the thermal stability issue. In this paper, we analytically demonstrate the feasibility of a binary 'logic wire' implemented with an array of circular nanomagnets that are clocked with voltage-induced strain applied by an underlying piezoelectric substrate. This leads to an energy-efficient logic paradigm orders of magnitude superior to existing CMOS-based logic that is scalable to dimensions substantially smaller than those for existing nanomagnetic logic approaches. The analytical approach is validated with experimental measurements conducted on dipole coupled Nickel (Ni) nanodots fabricated on a PMN-PT (Lead Magnesium Niobate-Lead Titanate) sample.

4.
Phys Rev Lett ; 111(2): 027204, 2013 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-23889436

RESUMO

We demonstrate in situ 90° electric field-induced uniform magnetization rotation in single domain submicron ferromagnetic islands grown on a ferroelectric single crystal using x-ray photoemission electron microscopy. The experimental findings are well correlated with micromagnetic simulations, showing that the reorientation occurs by the strain-induced magnetoelectric interaction between the ferromagnetic nanostructures and the ferroelectric crystal. Specifically, the ferroelectric domain structure plays a key role in determining the response of the structure to the applied electric field, resulting in three strain-induced regimes of magnetization behavior for the single domain islands.

5.
J Biomed Mater Res B Appl Biomater ; 100(3): 718-25, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22121079

RESUMO

A flexible, low profile, flow diversion stent could replace endovascular coiling for the treatment of intracranial aneurysms. Micropatterned-thin film nitinol (TFN) is a novel biomaterial with high potential for use in next-generation endovascular devices. Recent advancements in micropatterning have allowed for fabrication of a hyperelastic thin film nitinol (HE-TFN). In this study, the authors describe in vitro and in vivo testing of novel HE-TFN based flow diverting stents. Two types of HE-TFN with expanded pores having long axes of 300 and 500 µm were used to fabricate devices. In vitro examination of the early thrombotic response in whole blood showed a possible mechanism for the device's function, whereby HE-TFN serves as a scaffold for blood product deposition. In vivo testing in swine demonstrated rapid occlusion of model wide-neck aneurysms. Average time to occlusion for the 300-µm device was 10.4 ± 5.5 min. (N = 5) and 68 ± 30 min for the 500-µm device (N = 5). All aneurysms treated with bare metal control stents remained patent after 240 min (N = 3). SEM of acutely harvested devices supported in vitro results, demonstrating that HE-TFN serves as a scaffold for blood product deposition, potentially enhancing its flow-diverting effect. Histopathology of devices after 42 days in vivo demonstrated a healthy neointima and endothelialization of the aneurysm neck region. HE-TFN flow-diverting stents warrant further investigation as a novel treatment for intracranial aneurysms.


Assuntos
Ligas , Aneurisma Intracraniano/cirurgia , Teste de Materiais , Stents , Animais , Modelos Animais de Doenças , Feminino , Humanos , Porosidade , Suínos
6.
Biomaterials ; 31(34): 8864-71, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20810163

RESUMO

Because of its low profile and biologically inert behavior, thin film nitinol (TFN) is ideally suited for use in construction of endovascular devices. We have developed a surface treatment for TFN designed to minimize platelet adhesion by creating a superhydrophilic surface. The hemocompatibility of expanded polytetrafluorethylene (ePTFE), untreated thin film nitinol (UTFN), and a surface treated superhydrophilic thin film nitinol (STFN) was compared using an in vitro circulation model with whole blood under flow conditions simulating a moderate arterial stenosis. Scanning electron microscopy analysis showed increased thrombus on ePTFE as compared to UTFN or STFN. Total blood product deposition was 6.3 ± 0.8 mg/cm(2) for ePTFE, 4.5 ± 2.3 mg/cm(2) for UTFN, and 2.9 ± 0.4 mg/cm(2) for STFN (n = 12, p < 0.01). ELISA assay for fibrin showed 326 ± 42 µg/cm(2) for ePTFE, 45.6 ± 7.4 µg/cm(2) for UTFN, and 194 ± 25 µg/cm(2) for STFN (n = 12, p < 0.01). Platelet deposition measured by fluorescent intensity was 79,000 20,000 AU/mm(2) for ePTFE, 810 ± 190 AU/mm(2) for UTFN, and 1600 ± 25 AU/mm(2) for STFN (n = 10, p < 0.01). Mass spectrometry demonstrated a larger number of proteins on ePTFE as compared to either thin film. UTFN and STFN appear to attract significantly less thrombus than ePTFE. Given TFN's low profile and our previously demonstrated ability to place TFN covered stents in vivo, it is an excellent candidate for use in next-generation endovascular stents grafts.


Assuntos
Ligas/farmacologia , Estenose Coronária/fisiopatologia , Hemorreologia/efeitos dos fármacos , Teste de Materiais/métodos , Plaquetas/efeitos dos fármacos , Plaquetas/metabolismo , Proteínas Sanguíneas/química , Proteínas Sanguíneas/metabolismo , Fibrina/metabolismo , Humanos , Espectrometria de Massas , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência , Trombose/patologia
7.
IEEE Trans Haptics ; 2(1): 52-56, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-27788096

RESUMO

A multi-element tactile feedback (MTF) system has been developed to translate the force distribution, in magnitude and position, from 3times2 sensor arrays on surgical robotic end-effectors to the fingers via 3times2 balloon tactile displays. High detection accuracies from perceptual tests (> 96%) suggest that MTF may be an effective means to improve robotic control.

8.
J Biomed Mater Res A ; 82(3): 768-76, 2007 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-17330873

RESUMO

Thin film nitinol and single crystal Ni-Mn-Ga represent two new shape memory materials with potential to be used as percutaneously placed implant devices. However, the biocompatibility of these materials has not been adequately assessed. Immersion tests were conducted on both thin film nitinol and single crystal Ni-Mn-Ga in Hank's balanced salt solution at 37 degrees C and pH 7.4. After 12 h, large pits were found on the Ni-Mn-Ga samples while thin film nitinol displayed no signs of corrosion. Further electrochemical tests on thin film nitinol samples revealed breakdown potentials superior to a mechanically polished nitinol disc. These results suggest that passivation or electropolishing of thin film nitinol maybe unnecessary to promote corrosion resistance.


Assuntos
Ligas , Corrosão , Teste de Materiais , Níquel , Materiais Biocompatíveis/normas , Soluções Isotônicas , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA