Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Clin Virol ; 57(1): 29-35, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23369886

RESUMO

BACKGROUND: DBS testing has been used successfully to detect HCV antibody positive individuals. Determining how long someone has been infected is important for surveillance initiatives. Antibody avidity is a method that can be used to calculate recency of infection. OBJECTIVES: A HCV avidity assay was evaluated for both plasma and DBS. STUDY DESIGN: To measure antibody avidity a commercial HCV ELISA was modified using 7 M urea. The plasma samples were split into: group 1 (recently infected N = 19), group 2 (chronic carrier N = 300) and group 3 (resolved infection N = 82). Mock DBS made from group 1 (N = 12), group 2 (N = 50), group 3 (N = 25) and two seroconverter panels were evaluated. 133 DBS taken from patients known to have a resolved infection or be a chronic carrier were also tested. RESULTS: The avidity assay cut-off was set at AI≤30 for a recent infection. Using sequential samples the assay could detect a recent infection in the first 4-5 months from the point of infection. Most of the false positive results (AI < 30 among cases known not to have had recent infection) were detected among known resolved infections, in both the plasma and DBS; as a result, a testing algorithm has been designed incorporating both PCR and two dilution factors. The sensitivity and specificity of the assay on plasma was 100% and 99.3%, respectively, while DBS had 100% sensitivity and 98.3% specificity. CONCLUSION: The HCV avidity assay can be used to distinguish between chronic and recent infection using either plasma or DBS as the sample type.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Anticorpos Anti-Hepatite C/sangue , Hepatite C/imunologia , Adolescente , Adulto , Idoso , Afinidade de Anticorpos , Criança , Pré-Escolar , Hepacivirus , Hepatite C/sangue , Hepatite C/diagnóstico , Hepatite C Crônica/sangue , Hepatite C Crônica/diagnóstico , Hepatite C Crônica/imunologia , Humanos , Limite de Detecção , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
2.
J Virol Methods ; 189(1): 143-7, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23000752

RESUMO

Infectious conjunctivitis can be difficult to distinguish clinically due to the considerable overlap in clinical presentation so clinical diagnosis of conjunctivitis is often insufficient. It is therefore necessary to have a rapid diagnostic test that differentiates between the different causes of infectious conjunctivitis. Screening clinical samples by sample type/syndrome based multiplex real time PCR would allow for rapid detection of a variety of pathogens simultaneously, which will in turn aid in the treatment and clinical management of the patient. A multiplex real-time PCR assay for rapid and simultaneous detection of HSV 1 and 2, VZV, adenovirus and Chlamydia trachomatis (C. trachomatis) from eye swabs was developed and evaluated. The multiplex assay was shown to be sensitive, specific and robust. Reductions in sample turn around times have been achieved by reducing the amount of separate tests needed to be carried out.


Assuntos
Conjuntivite Bacteriana/diagnóstico , Conjuntivite Bacteriana/microbiologia , Conjuntivite Viral/diagnóstico , Conjuntivite Viral/virologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Adenoviridae/genética , Infecções por Adenoviridae/diagnóstico , Infecções por Chlamydia/diagnóstico , Chlamydia trachomatis/genética , DNA Bacteriano/análise , DNA Viral/análise , Feminino , Herpes Simples/diagnóstico , Herpes Zoster/diagnóstico , Herpesvirus Humano 1/genética , Herpesvirus Humano 1/isolamento & purificação , Herpesvirus Humano 2/genética , Herpesvirus Humano 2/isolamento & purificação , Herpesvirus Humano 3/genética , Herpesvirus Humano 3/isolamento & purificação , Humanos , Masculino
3.
J Clin Virol ; 57(3): 201-8, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22789139

RESUMO

A wide variety of commercial assays is available for the detection of hepatitis B surface antigen (HBsAg). Clearly, the sensitivity of an assay to detect a variant is dependent on the anti-HBs usage. Thus, it is not surprising that there are examples of variants that cannot be detected by all assays. Data from Europe, Asia and Africa about HBsAg variants which are not recognized by either monoclonal or polyclonal antibodies specific for wild-type group 'a' determinant, but positive by DNA polymerase chain reaction (PCR) in chronic patients and from vaccinated children are increasing. This would impose a challenge for public health issues of hepatitis B virus. In this review we tried to summarize the discrepancies between results of HBsAg assays and to explain some rationales for these inconsistencies.


Assuntos
Técnicas de Laboratório Clínico/métodos , Erros de Diagnóstico , Variação Genética , Anticorpos Anti-Hepatite B , Antígenos de Superfície da Hepatite B/sangue , Hepatite B/diagnóstico , Hepatite B/virologia , África , Ásia , Europa (Continente) , Humanos , Imunoensaio/métodos , Sensibilidade e Especificidade
4.
J Clin Microbiol ; 50(9): 2910-7, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22740708

RESUMO

Nucleic acid amplification methods such as the PCR have had a major impact on the diagnosis of viral infections, often achieving greater sensitivities and shorter turnaround times than conventional assays and an ability to detect viruses refractory to conventional isolation methods. Their effectiveness is, however, significantly influenced by assay target sequence variability due to natural diversity and rapid sequence changes in viruses that prevent effective binding of primers and probes. This was investigated for a diverse range of enteroviruses (EVs; species A to D), human rhinoviruses (HRVs; species A to C), and human parechovirus (HPeV) in a multicenter assay evaluation using a series of full-length prequantified RNA transcripts. RNA concentrations were quantified by absorption (NanoDrop) and fluorescence methods (RiboGreen) prior to dilution in buffer supplemented with RNase inhibitors and carrier RNA. RNA transcripts were extremely stable, showing minimal degradation after prolonged storage at temperatures between ambient and -20°C and after multiple freeze-thaw cycles. Transcript dilutions distributed to six referral laboratories were screened by real-time reverse transcriptase PCR assays using different primers and probes. All of the laboratories reported high assay sensitivities for EV and HPeV transcripts approaching single copies and similar amplification kinetics for all four EV species. HRV detection sensitivities were more variable, often with substantially impaired detection of HRV species C. This could be accounted for in part by the placement of primers and probes to genetically variable target regions. Transcripts developed in this study provide reagents for the ongoing development of effective diagnostics that accommodate increasing knowledge of genetic heterogeneity of diagnostic targets.


Assuntos
Enterovirus/classificação , Enterovirus/isolamento & purificação , Parechovirus/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Rhinovirus/classificação , Rhinovirus/isolamento & purificação , Enterovirus/genética , Humanos , Programas de Rastreamento/métodos , Dados de Sequência Molecular , Parechovirus/genética , RNA Viral/genética , RNA Viral/isolamento & purificação , Rhinovirus/genética , Sensibilidade e Especificidade , Análise de Sequência de DNA , Transcrição Gênica , Virologia/métodos
5.
J Clin Virol ; 54(2): 106-9, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22418454

RESUMO

BACKGROUND: An estimated 130-170 million people worldwide are chronically infected with HCV.(1) In Europe the highest prevalence of HCV infections is in the IDU population.(2) As traditional HCV screening relies on the detection of HCV antibody or HCV RNA in blood, screening in high-risk groups such as IDU is difficult due to poor venous access caused by damaged veins. OBJECTIVES: In this study DBS was evaluated as an alternative sample type to blood for the detection of HCV RNA. STUDY DESIGN: The endpoint detection limit, inter-assay and intra-assay variability of the method were determined. The DBS method was compared to our routine frontline assay using a panel of paired DBS and blood samples. The effect of different storage temperatures and length of storage time on the stability of HCV RNA in DBS was also assessed. RESULTS: The endpoint detection limit of the method based on results from mock DBS was 250 IU/ml. The method was shown to be precise and robust. The sensitivity and specificity of the method was found to be 100% and 95.8%, respectively. No significant variation in the stability of HCV RNA in DBS over a 1 year period at a range of different temperatures was observed. CONCLUSIONS: A sensitive and stable method was developed for the detection of HCV RNA in DBS. Screening high-risk populations using DBS as a sample type may improve uptake of HCV testing by increasing opportunity for patients to be tested and consequently increasing access to treatment.


Assuntos
Sangue/virologia , Dessecação , Hepacivirus/isolamento & purificação , Hepatite C/diagnóstico , RNA Viral/isolamento & purificação , Manejo de Espécimes/métodos , Europa (Continente) , Hepatite C/virologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura , Fatores de Tempo
7.
J Environ Public Health ; 2011: 407505, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21977047

RESUMO

BACKGROUND: We set out to identify the level of previous exposure to influenza A (H1N1) in unvaccinated healthcare workers (HCWs) at the peak of the pandemic outbreak in the UK, with control samples collected prior to the outbreak. METHODS: Cross-sectional study (seroprevalence assessed before and at pandemic peak, with questionnaire data collected at peak of outbreak) in HCWs in Scotland. RESULTS: The prevalence of seropositivity in 493 HCWs at pandemic peak was 10.3%, which was higher than the prepandemic level by 3.7 percentage points (95% CI 0.3% to 7.3%, P = 0.048). Seropositivity rates for frontline and nonfrontline HCWs were similar. CONCLUSION: At pandemic peak, only 10.3% of HCWs were seropositive for influenza A (H1N1), so the great majority were still susceptible to infection at the introduction of the vaccination programme. Few studies have reported on seroprevalence in unvaccinated and asymptomatic participants, so our findings may have relevance to the wider population.


Assuntos
Anticorpos Antivirais/sangue , Pessoal de Saúde , Vírus da Influenza A Subtipo H1N1/imunologia , Influenza Humana/epidemiologia , Pandemias , Adolescente , Adulto , Idoso , Estudos Transversais , Humanos , Influenza Humana/sangue , Modelos Logísticos , Pessoa de Meia-Idade , Prevalência , Escócia/epidemiologia , Estudos Soroepidemiológicos , Vacinação , Adulto Jovem
8.
BMC Infect Dis ; 11: 192, 2011 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-21752259

RESUMO

BACKGROUND: During the April-July 2009 outbreak of H1N1/2009 in scotland the West of Scotland Specialist Virology Centre (WoSSVC) in Glasgow tested > 16,000 clinical samples for H1N1/2009. Most were from patients clinically diagnosed with H1N1/2009. Out of these, 9% were positive. This study sought to determine what respiratory pathogens were misdiagnosed as cases of H1N1/2009 during this time. METHODS: We examined the results from 3247 samples which were sent to the laboratory during April-July 2009. All were from patients clinically diagnosed as having H1N1/2009 (based on accepted criteria) and all were given a full respiratory screen using real time reverse transcriptase polymerase chain reaction (rtRT-PCR) assays. RESULTS: In total, respiratory pathogens were detected in 27.9% (95% confidence interval, 26.3-29.5%) of the samples submitted. Numerous pathogens were detected, the most common of which were rhinovirus (8.9% (95% confidence interval, 7.9-9.9%)), parainfluenza 1 (1.9% (95% confidence interval, 1.4-2.4%)) and 3 (4.1% (95% confidence interval, 3.3-4.9%)), and adenovirus ((3.5% (95% confidence interval, 2.9-4.2%)). CONCLUSIONS: This study highlights the problems of using a clinical algorithm to detect H1N1/2009. Clinicians frequently misdiagnosed common respiratory pathogens as H1N1/2009 during the spring/summer outbreak in Scotland. Many undesirable consequences would have resulted, relating to treatment, infection control, and public health surveillance.


Assuntos
Surtos de Doenças , Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Influenza Humana/epidemiologia , Influenza Humana/virologia , Infecções Respiratórias/epidemiologia , Infecções Respiratórias/virologia , Adolescente , Adulto , Idoso , Algoritmos , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Estudos de Coortes , Erros de Diagnóstico/estatística & dados numéricos , Humanos , Lactente , Influenza Humana/diagnóstico , Pessoa de Meia-Idade , Infecções Respiratórias/diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Escócia/epidemiologia
9.
J Clin Microbiol ; 49(7): 2620-4, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21593263

RESUMO

Enteroviruses (EVs) are recognized as the major etiological agent in meningitis in children and young adults. The use of molecular techniques, such as PCR, has substantially improved the sensitivity of enterovirus detection compared to that of virus culture methods. PCR-based methods also can detect a much wider range of EV variants, including those within species A, as well as human parechoviruses (HPeVs) that often grow poorly in vitro and which previously have been underdiagnosed by traditional methods. To exploit these developments, we developed a real-time one-step reverse transcription-PCR (RT-PCR) for the rapid and sensitive detection of EV and HPeV in clinical specimens. Two commercially available RT-PCR kits were used (method I, Platinum one-step kit; method II, Express qPCR one-step kit) with primers and probes targeting the EV and HPeV 5'-untranslated regions (5'UTR). Amplification dynamics (threshold cycle [C(T)]values and efficiencies) of absolutely quantified full-length RNA transcripts representative of EV species A to D and HPeV were similar, demonstrating the effectiveness of both assays across the range of currently described human EV and HPeV variants. Probit analysis of multiple endpoint replicates demonstrated comparable sensitivities of the assays for EV and HPeV (method I, approximately 10 copies per reaction for both targets; method II, 20 copies per reaction). C(T) values were highly reproducible on repeat testing of positive controls within assays and between assay runs. Considering the sample turnaround time of less than 3 h, the multiplexed one-step RT-PCR method provides rapid diagnostic testing for EV and HPeV in cases of suspected central nervous system infections in a clinically relevant time frame.


Assuntos
Técnicas de Laboratório Clínico/métodos , Infecções por Enterovirus/diagnóstico , Enterovirus/isolamento & purificação , Parechovirus/isolamento & purificação , Infecções por Picornaviridae/diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Virologia/métodos , Criança , Pré-Escolar , Enterovirus/genética , Infecções por Enterovirus/virologia , Humanos , Parechovirus/genética , Infecções por Picornaviridae/virologia , RNA Viral/genética , RNA Viral/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo , Adulto Jovem
10.
J Virol Methods ; 171(1): 86-90, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20951165

RESUMO

Influenza A H1N1 (2009) was declared by the World Health Organisation (WHO) as the first influenza pandemic of the 21st century. Rapid detection of influenza A and differentiation of influenza A H1N1 (2009) and seasonal influenza A is beneficial. In addition the rapid detection of antiviral resistant strains of influenza A H1N1 (2009) would be useful for clinicians to allow for change to an effective treatment at a much earlier stage if resistance is found. It was the aim of this study to develop a real-time RT-PCR that can detect all influenza A viruses and type simultaneously for influenza A H1N1 (2009) and oseltamivir resistant (H275Y) influenza A H1N1 (2009). This multiplex assay will allow laboratories to screen respiratory samples for all types of influenza A, influenza A H1N1 (2009) virus and oseltamivir resistant (H275Y) influenza A H1N1 (2009) virus in a rapid and cost effective format, ensuring that typing methods for seasonal and avian viruses are used on a smaller subset of samples. Since most virology laboratories already offer a molecular service for influenza A this assay could easily be implemented into most areas at little cost therefore increasing local access to resistance testing.


Assuntos
Farmacorresistência Viral , Vírus da Influenza A/classificação , Vírus da Influenza A/isolamento & purificação , Influenza Humana/diagnóstico , Influenza Humana/virologia , Oseltamivir/farmacologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Substituição de Aminoácidos/genética , Humanos , Vírus da Influenza A/efeitos dos fármacos , Vírus da Influenza A/genética , Testes de Sensibilidade Microbiana/métodos , Mutação de Sentido Incorreto , Neuraminidase/genética , Sensibilidade e Especificidade , Proteínas Virais/genética
11.
Sex Transm Infect ; 86(7): 537-9, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20643660

RESUMO

OBJECTIVES: To develop, evaluate and implement a new multiplex real-time PCR test for the detection of herpes simplex virus (HSV)1, HSV2 and syphilis in a single sample using a single test. METHODS: A multiplex real-time PCR test detecting HSV1, HSV2 and Treponema pallidum was designed, validated and evaluated for a period of 6 months on patients attending the Sandyford Initiative (a series of genitourinary medicine clinics in and around Glasgow). A total of 692 samples were tested, and T pallidum PCR positives were confirmed by a second PCR at the Scottish Reference Laboratory (SBSTIRL). All PCR results were aligned with dark ground microscopy findings and serological results where available and compared. RESULTS: The laboratory validation of the multiplex assay showed the test to be sensitive, specific and robust. Of the 692 samples, 139 were positive for HSV1, 136 for HSV2, 15 for syphilis, one for both syphilis and HSV1, and 401 were negative; the reference laboratory confirmed all T pallidum PCR-positive samples. The PCR test was more sensitive than both dark ground microscopy and serological testing for the diagnosis of primary syphilis. CONCLUSIONS: The introduction of this new test has led to a better turnaround time for the diagnosis of genital ulcer disease, better detection of primary syphilis infection, and the detection of unexpected cases of syphilis where the aetiological agent suspected was HSV.


Assuntos
Herpes Genital/diagnóstico , Herpesvirus Humano 1/isolamento & purificação , Herpesvirus Humano 2/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Sífilis/diagnóstico , Treponema pallidum/isolamento & purificação , Diagnóstico Precoce , Humanos , Sensibilidade e Especificidade
12.
PLoS One ; 5(5): e10675, 2010 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-20502691

RESUMO

BACKGROUND: The cause of severe disease in some patients infected with pandemic influenza A virus is unclear. METHODOLOGY/PRINCIPAL FINDINGS: We present the cellular immunology profile in the blood, and detailed clinical (and post-mortem) findings of three patients with rapidly progressive infection, including a pregnant patient who died. The striking finding is of reduction in natural killer (NK) cells but preservation of activated effector CD8 T lymphocytes; with viraemia in the patient who had no NK cells. Comparison with control groups suggests that the reduction of NK cells is unique to these severely ill patients. CONCLUSION/SIGNIFICANCE: Our report shows markedly reduced NK cells in the three patients that we sampled and raises the hypothesis that NK may have a more significant role than T lymphocytes in controlling viral burden when the host is confronted with a new influenza A virus subtype.


Assuntos
Linfócitos T CD8-Positivos/imunologia , Vírus da Influenza A Subtipo H1N1/imunologia , Influenza Humana/imunologia , Influenza Humana/virologia , Células Matadoras Naturais/imunologia , Adulto , Linfócitos T CD8-Positivos/virologia , Evolução Fatal , Feminino , Congelamento , Saúde , Humanos , Influenza Humana/sangue , Influenza Humana/diagnóstico por imagem , Células Matadoras Naturais/virologia , Pulmão/imunologia , Pulmão/patologia , Pulmão/virologia , Masculino , Pessoa de Meia-Idade , Mudanças Depois da Morte , Gravidez , RNA Viral/sangue , Radiografia Torácica , Adulto Jovem
13.
J Virol Methods ; 163(1): 17-24, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19638287

RESUMO

Acute respiratory tract infections are a major cause of morbidity and mortality worldwide and exert a considerable economic burden on healthcare systems. Acute respiratory tract infections of the upper and lower respiratory tract are caused by a wide variety of viral and bacterial pathogens, which require comprehensive laboratory investigations. Conventional serological and immunofluorescence-based diagnostic methods for acute respiratory tract infections lack sensitivity when compared to polymerase chain reaction (PCR)-based approaches and the development of new diagnostic methodologies is required, to provide accurate, sensitive and rapid diagnoses. In the present study, a PCR-based low density oligonucleotide microarray was developed for the detection of 16 viral and two atypical bacterial pathogens. The performance of this DNA microarray-based analysis exhibited comparable sensitivities and specificities to multiplex real-time reverse transcription polymerase chain reactions (rtPCRs) confirming the potential diagnostic utility of the method. In contrast to routine multiplex PCR, the microarray incorporates an intrinsic redundancy as multiple and non-identical probes per target on the array allow direct intra-assay confirmation of positives. This study demonstrates that microarray technology provides a viable alternative to conventional serological-based approaches and multiplex PCR for pathogen identification in acute respiratory tract infections.


Assuntos
Bactérias/isolamento & purificação , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Infecções Respiratórias/diagnóstico , Vírus/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Respiratórias/microbiologia , Infecções Respiratórias/virologia , Sensibilidade e Especificidade , Adulto Jovem
14.
J Clin Virol ; 45(3): 196-9, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19540799

RESUMO

BACKGROUND: A novel influenza A virus, subtype H1N1 of swine-lineage (H1N1 swl) has transmitted rapidly to many regions of the world with evidence of sustained transmission within some countries. Rapid detection and differentiation from seasonal influenza is essential to instigate appropriate patient and public health management and for disease surveillance. OBJECTIVES: To develop a rapid and sensitive real-time reverse transcriptase polymerase chain reaction (rtRT-PCR) for confirmation of H1N1 swl. STUDY DESIGN: A one-step rtRT-PCR approach was employed to target the matrix gene of the novel influenza A/H1N1 swl and validated against a panel of seasonal influenza A (H1N1 and H3N2), swine influenza A/H1N1 and avian influenza A/H5N1 viruses. The assay following validation was then used prospectively to detect H1N1 swl positive specimens from the recent outbreaks in the UK and the Republic of Ireland. RESULTS: The one-step H1N1 swl matrix rtRT-PCR successfully detected H1N1 swl clinical specimens and did not cross-react with seasonal influenza A, subtypes H1N1 and H3N2 viruses and swine influenza A (H1N1). The H1N1 swl matrix assay did cross react with H5N1. The H1N1 swl matrix assay was then compared to two other assays using a dilution series and a panel of untyped influenza A positive clinical samples. These experiments found the assay to have a comparable sensitivity to the established universal influenza A rtRT-PCR and was more sensitive than the H1N1 swl specific assay that targeted the H1 region. CONCLUSIONS: The results demonstrate that the rtRT-PCR is sensitive and should be used alongside existing universal influenza A assays to rapidly detect the novel H1N1 swl virus.


Assuntos
Surtos de Doenças , Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Influenza Humana/diagnóstico , Influenza Humana/virologia , Vírus Reordenados/isolamento & purificação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Animais , Humanos , Vírus da Influenza A Subtipo H1N1/genética , Influenza Humana/epidemiologia , Irlanda/epidemiologia , Dados de Sequência Molecular , RNA Viral/genética , Vírus Reordenados/genética , Sensibilidade e Especificidade , Análise de Sequência de DNA , Suínos , Reino Unido/epidemiologia , Proteínas da Matriz Viral/genética
16.
J Clin Virol ; 43(4): 367-71, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18823817

RESUMO

Nucleic acid amplification technique (NAT)-based assays are replacing traditional diagnostic methods in clinical laboratories. However, many of these assays are developed in-house and the lack of standardised reference materials has hindered assay implementation and control. Consequently, in the UK, the Clinical Virology Network (CVN), the National Institute for Biological Standards and Control (NIBSC), and the Health Protection Agency (HPA), are working in collaboration to develop working standards or 'run controls' for diagnostic NAT-based assays, particularly real-time PCR. These run controls are intended for use in microbiology laboratories and are designed to be extracted and amplified in the same way as clinical samples and included in each assay run. The aim is to enable clinical laboratories to continuously monitor the performance of their diagnostic NAT assays on a run-by-run basis allowing inter-laboratory comparisons, and ultimately improving the consistency of results. At present, eight candidate run controls representing clinically relevant viral targets have been prepared for evaluation by CVN laboratories. Data have been returned on the performance of each run control in routine diagnostic assays. Preliminary results presented here indicate a high level of variability in intra- and inter-assay detection of these targets, highlighting the need for standardisation of assays within molecular diagnostics.


Assuntos
Técnicas de Diagnóstico Molecular/normas , Técnicas de Amplificação de Ácido Nucleico/normas , Virologia/normas , Viroses/diagnóstico , Vírus/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Padrões de Referência , Reino Unido , Virologia/métodos
17.
J Med Virol ; 80(9): 1615-23, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18649324

RESUMO

Most human cytomegalovirus (HCMV) genes are highly conserved in sequence among strains, but some exhibit a substantial degree of variation. Two of these genes are UL146, which encodes a CXC chemokine, and UL139, which is predicted to encode a membrane glycoprotein. The sequences of these genes were determined from a collection of 184 HCMV samples obtained from Africa, Australia, Asia, Europe, and North America. UL146 is hypervariable throughout, whereas variation in UL139 is concentrated in a sequence encoding a potentially highly glycosylated region. The UL146 sequences fell into 14 genotypes, as did all previously reported sequences. The UL139 sequences grouped into 8 genotypes, and all previously reported sequences fell into a subset of these. There were minor differences among continents in genotypic frequencies for UL146 and UL139, but no clear geographical separation, and identical nucleotide sequences were represented among communities distant from each other. The frequent detection of multiple genotypes indicated that mixed infections are common. For both genes, the degree of divergence was sufficient to preclude reliable sequence alignments between genotypes in the most variable regions, and the mode of evolution involved in generating the genotypes could not be discerned. Within genotypes, constraint appears to have been the predominant mode, and positive selection was detected marginally at best. No evidence was found for linkage disequilibrium. The emerging scenario is that the HCMV genotypes developed in early human populations (or even earlier), becoming established via founder or bottleneck effects, and have spread, recombined and mixed worldwide in more recent times.


Assuntos
Quimiocinas CXC/genética , Citomegalovirus/genética , Glicoproteínas de Membrana/genética , Polimorfismo Genético , Proteínas Virais/genética , África , Sequência de Aminoácidos , Ásia , Austrália , Citomegalovirus/classificação , Citomegalovirus/isolamento & purificação , Infecções por Citomegalovirus/virologia , Europa (Continente) , Evolução Molecular , Genótipo , Humanos , Dados de Sequência Molecular , América do Norte , Filogenia , Alinhamento de Sequência , Análise de Sequência de DNA
18.
J Clin Virol ; 38(2): 153-6, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17142100

RESUMO

BACKGROUND: In Scotland there has been an outbreak of mumps with over 4000 confirmed cases in the last 2 years. As laboratory diagnosis is usually requested on patients with symptoms, a prompt diagnosis early in the illness is required. OBJECTIVES: To assess the performance of the five different commercial IgM-ELISAs used in Scottish Virus laboratories. STUDY DESIGN: The Specialist Virology Laboratory (SVC) Edinburgh distributed a serum panel to all Scottish laboratories that diagnose mumps by IgM-ELISA. The panel consisted of 45 sera from patients with confirmed mumps (date of onset known for 44/45) and 11 sera from patients with alternative diagnoses. Each laboratory performed their own commercial IgM-ELISAs blindly and reported results to the SVC Edinburgh. RESULTS: Sensitivity ranged from 24% to 51%. Assays performed better on samples taken later than 10 days after onset of symptoms. Specificity was about 82% for most assays. CONCLUSION: The sensitivity of commercial mumps IgM-ELISAs varied greatly. The Microimmune mumps-IgM ELISA had the best overall sensitivity in acute serum specimens. Diagnostic laboratories should be developing the means to perform direct detection of mumps virus for acute presentation and requesting convalescent bloods, if acute blood samples have no detectable IgM.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina M/sangue , Caxumba/imunologia , Adulto , Humanos , Imunoglobulina M/imunologia , Caxumba/sangue , Caxumba/diagnóstico , Sensibilidade e Especificidade
20.
World J Gastroenterol ; 12(33): 5368-74, 2006 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-16981270

RESUMO

AIM: To investigate the reactivity of a panel of 8 mouse anti-hepatitis B surface antigen (HBsAg) monoclonal antibodies (mAbs) using a collection of 9 recombinant HBsAg mutants with a variety of amino acid substitutions mostly located within the "a" region. METHODS: The entire HBs genes previously cloned into a mammalian expression vector were transiently transfected into COS7 cells. Two standard unmutated sequences of the ayw and adw subtypes served as controls. Secreted mutant proteins were collected and measured by three commercial diagnostic immunoassays to assess transfection efficiency. Reactivity of anti-HBs mAbs with mutated HBsAgs was determined by sandwich enzyme-linked immunosorbent assay (ELISA). RESULTS: Reactivity of anti-HBs mAbs with mutated HBsAgs revealed different patterns. While three mutants reacted strongly with all mAbs, two mutants reacted weakly with only two mAbs and the remaining proteins displayed variable degrees of reactivity towards different mAbs. Accordingly, four groups of mAbs with different but overlapping reactivity patterns could be envisaged. One group consisting of two mAbs (37C5-S7 and 35C6-S11) was found to recognize stable linear epitopes conserved in all mutants. Mutations outside the "a" determinant at positions 120 (P-->S), 123(T-->N) and 161 (M-->T) were found to affect reactivity of these mAbs. CONCLUSION: Our findings could have important implications for biophysical studies, vaccination strategies and immunotherapy of hepatitis B virus (HBV) mutants.


Assuntos
Anticorpos Monoclonais/química , Anticorpos Anti-Hepatite B/química , Antígenos de Superfície da Hepatite B/química , Animais , Antígenos Virais/química , Fenômenos Biofísicos , Biofísica , Células COS , Chlorocebus aethiops , Ensaio de Imunoadsorção Enzimática , Epitopos , Antígenos de Superfície da Hepatite B/imunologia , Imunoensaio , Imunoterapia/métodos , Camundongos , Plasmídeos/metabolismo , Coelhos , Proteínas Recombinantes/química , Transfecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA