Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Front Bioeng Biotechnol ; 12: 1412136, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38952671

RESUMO

Introduction: Clinics increasingly require readily deployable tubular substitutes to restore the functionality of structures like ureters and blood vessels. Despite extensive exploration of various materials, both synthetic and biological, the optimal solution remains elusive. Drawing on abundant literature experiences, there is a pressing demand for a substitute that not only emulates native tissue by providing requisite signals and growth factors but also exhibits appropriate mechanical resilience and behaviour. Methods: This study aims to assess the potential of porcine ureters by characterizing their biomechanical properties in their native configuration through ring and membrane flexion tests. In order to assess the tissue morphology before and after mechanical tests and the eventual alteration of tissue microstructure that would be inserted in material constitutive description, histological staining was performed on samples. Corresponding computational analyses were performed to mimic the experimental campaign to identify the constitutive material parameters. Results: The absence of any damages to muscle and collagen fibres, which only compacted after mechanical tests, was demonstrated. The experimental tests (ring and membrane flexion tests) showed non-linearity for material and geometry and the viscoelastic behaviour of the native porcine ureter. Computational models were descriptive of the mechanical behaviour ureteral tissue, and the material model feasible. Discussion: This analysis will be useful for future comparison with decellularized tissue for the evaluation of the aggression of cell removal and its effect on microstructure. The computational model could lay the basis for a reliable tool for the prediction of solicitation in the case of tubular substitutions in subsequent simulations.

2.
Updates Surg ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38954375

RESUMO

The relatively recent adoption of Endoscopic Sleeve Gastroplasty (ESG) amongst obese patients has gained approval within the surgical community due to its notable benefits, including significant weight loss, safety, feasibility, repeatability, and potential reversibility. However, despite its promising clinical outcomes and reduced invasiveness, there is still a lack of standardised procedures for performing ESG. Multiple suture patterns and stitching methods have been proposed over time, yet rational tools to quantify and compare their effects on gastric tissues are absent. To address this gap, this study proposed a computational approach. The research involved a case study analyzing three distinct suture patterns (C-shaped, U-shaped and Z-shaped) using a patient-specific computational stomach model generated from magnetic resonance imaging. Simulations mimicked food intake by placing wire features in the intragastric cavity to replicate sutures, followed by applying a linearly increasing internal pressure up to 15 mmHg. The outcomes facilitated comparisons between suture configurations based on pressure-volume behaviours and the distribution of maximum stress on biological tissues, revealing the U-shaped as the more effective in terms of volume reduction, even if with reduced elongation strains and increased tissues stresses, whereas the Z-shaped is responsible of the greatest stomach shortness after ESG. In summary, computational biomechanics methods serve as potent tools in clinical and surgical settings, offering insights into aspects that are challenging to explore in vivo, such as tissue elongation and stress. These methods allow for mechanical comparisons between different configurations, although they might not encompass crucial clinical outcomes.

3.
Artif Organs ; 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38895983

RESUMO

BACKGROUND: The standard artificial urinary sphincter (AUS) is an implantable device for the treatment of urinary incontinence by applying a pressure loading around the urethra through an inflatable cuff, often inducing no-physiological stimulation up to tissue degenerative phenomena. A novel in silico approach is proposed to fill the gap of the traditional procedures by providing tools to quantitatively assess AUS reliability and performance based on AUS-urethra interaction. METHODS: The approach requires the development of 3D numerical models of AUS and urethra, and experimental investigations to define their mechanical behaviors. Computational analyses are performed to simulate the urethral lumen occlusion by AUS inflation under different pressures, and the lumen opening by applying an intraluminal pressure progressively increased under the AUS action (Abaqus Explicit solver). The AUS reliability is evaluated in terms of tissue stimulation by the mechanical fields potentially responsible for vasoconstriction and tissue damage, while the performance by the intraluminal pressure that causes the lumen opening for a specific occlusive pressure, showing the maximum urethral pressure for which continence is guaranteed. RESULTS: The present study implemented the procedure considering the gold standard AMS 800 and a novel patented AUS. Results provided the comparison between two sphincteric devices and the evaluation of the influence of different building materials and geometrical features on the AUS functionality. CONCLUSIONS: The approach was developed for the AUS, but it could be adapted also to artificial sphincters for the treatment of other anatomical dysfunctions, widening the analyzable device configurations and reducing experimental and ethical efforts.

4.
Phys Eng Sci Med ; 47(2): 403-441, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38598066

RESUMO

Healthy cornea guarantees the refractive power of the eye and the protection of the inner components, but injury, trauma or pathology may impair the tissue shape and/or structural organization and therefore its material properties, compromising its functionality in the ocular visual process. It turns out that biomechanical research assumes an essential role in analysing the morphology and biomechanical response of the cornea, preventing pathology occurrence, and improving/optimising treatments. In this review, ex vivo, in vivo and in silico methods for the corneal mechanical characterization are reported. Experimental techniques are distinct in testing mode (e.g., tensile, inflation tests), samples' species (human or animal), shape and condition (e.g., healthy, treated), preservation methods, setup and test protocol (e.g., preconditioning, strain rate). The meaningful results reported in the pertinent literature are discussed, analysing differences, key features and weaknesses of the methodologies adopted. In addition, numerical techniques based on the finite element method are reported, incorporating the essential steps for the development of corneal models, such as geometry, material characterization and boundary conditions, and their application in the research field to extend the experimental results by including further relevant aspects and in the clinical field for diagnostic procedure, treatment and planning surgery. This review aims to analyse the state-of-art of the bioengineering techniques developed over the years to study the corneal biomechanics, highlighting their potentiality to improve diagnosis, treatment and healing process of the corneal tissue, and, at the same, pointing out the current limits in the experimental equipment and numerical tools that are not able to fully characterize in vivo corneal tissues non-invasively and discourage the use of finite element models in daily clinical practice for surgical planning.


Assuntos
Simulação por Computador , Córnea , Córnea/fisiologia , Humanos , Fenômenos Biomecânicos , Animais , Análise de Elementos Finitos , Modelos Biológicos
5.
BMC Vet Res ; 20(1): 153, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659026

RESUMO

BACKGROUND: Melting corneal ulcers are a serious condition that affects a great number of animals and people around the world and it is characterised by a progressive weakening of the tissue leading to possible severe ophthalmic complications, such as visual impairment or blindness. This disease is routinely treated with medical therapy and keratoplasty, and recently also with alternative regenerative therapies, such as cross-linking, amniotic membrane transplant, and laser. Plasma medicine is another recent example of regenerative treatment that showed promising results in reducing the microbial load of corneal tissue together with maintaining its cellular vitality. Since the effect of helium plasma application on corneal mechanical viscoelasticity has not yet been investigated, the aim of this study is first to evaluate it on ex vivo porcine corneas for different exposition times and then to compare the results with previous data on cross-linking treatment. RESULTS: 94 ex vivo porcine corneas divided into 16 populations (healthy or injured, fresh or cultured and treated or not with plasma or cross-linking) were analysed. For each population, a biomechanical analysis was performed by uniaxial stress-relaxation tests, and a statistical analysis was carried out considering the characteristic mechanical parameters. In terms of equilibrium normalised stress, no statistically significant difference resulted when the healthy corneas were compared with lesioned plasma-treated ones, independently of treatment time, contrary to what was obtained about the cross-linking treated corneas which exhibited more intense relaxation phenomena. CONCLUSIONS: In this study, the influence of the Helium plasma treatment was observed on the viscoelasticity of porcine corneas ex vivo, by restoring in lesioned tissue a degree of relaxation similar to the one of the native tissue, even after only 2 min of application. Therefore, the obtained results suggest that plasma treatment is a promising new regenerative ophthalmic therapy for melting corneal ulcers, laying the groundwork for further studies to correlate the mechanical findings with corneal histology and ultrastructural anatomy after plasma treatment.


Assuntos
Córnea , Hélio , Gases em Plasma , Animais , Suínos , Córnea/efeitos dos fármacos , Gases em Plasma/farmacologia , Gases em Plasma/uso terapêutico , Fenômenos Biomecânicos , Álcalis , Pressão Atmosférica , Úlcera da Córnea/veterinária , Úlcera da Córnea/terapia
6.
Comput Methods Programs Biomed ; 238: 107594, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37207463

RESUMO

BACKGROUND AND OBJECTIVE: In the field of urology, the pressure-flow study (PFS) is an essential urodynamics practise which requires the patient's transurethral catheterization during the voiding phase of micturition to evaluate the functionality of the lower urinary tract (LUT) and reveal the pathophysiology of its dysfunctionality. However, the literature evidences confusion regarding the interference of the catheterization on the urethral pressure-flow behaviour. METHODS: The present research study represents the first Computational Fluid-Dynamics (CFD) approach to this urodynamics issue, analysing the influence of a catheter in the male LUT through case studies which included the inter-individual and intra-individual dependence. A set of four three dimensional (3D) models of the male LUT, different in urethral diameters, and a set of three 3D models of the transurethral catheter, diverse in calibre, were developed leading to 16 CFD non-catheterized either catheterized configurations, to describe the typical micturition scenario considering both urethra and catheter characteristics. RESULTS: The developed CFD simulations showed that the urine flow field during micturition was influenced by the urethral cross-sectional area and each catheter determined a specific decrease in flow rate if compared to the relative free uroflow. CONCLUSIONS: In-silico methods allow to analyse relevant urodynamics aspects, which could not be investigated in vivo, and may support the clinical PFS to reduce uncertainty on urodynamic diagnosis.


Assuntos
Uretra , Bexiga Urinária , Humanos , Masculino , Micção/fisiologia , Catéteres , Urodinâmica/fisiologia
7.
Comput Methods Programs Biomed ; 231: 107409, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36780716

RESUMO

BACKGROUND AND OBJECTIVES: Gastro-oesophageal reflux disease (GERD) consists in the passage of gastric acid content from the stomach to the oesophagus, causing burns and deteriorating the quality of life. Laparoscopic Sleeve Gastrectomy (LSG) could induce de novo GERD and worsen pre-existing GERD because of the higher gastric pressurisation, reduction of stomach volume and a wider His-angle. In the proposed work, various computational gastric 2D models were developed to understand the effects of variables such as the His-angle, the antral dimension, and the bolus viscosity on the reflux increase. METHODS: Fluid-Structure Interaction (FSI) computational models which couple the solid mechanics of the gastric wall, and the fluid domain of the bolus, have been developed to shed light on biomechanical aspects of GERD after LSG. A closure was imposed to the lower oesophageal sphincter (LES) mimicking what happens physiologically after food intake. RESULTS: Results showed that the configuration prone to higher reflux flow was the post-surgical 65° model with a staple line starting directly from the pylorus without antral preservation, for all considered viscosities. Increasing viscosity, reflux flow decreased. Post-surgical refluxes were higher than pre-ones and decreased with increasing antrum preservation. CONCLUSIONS: These results could be a starting point for analysis of anatomical features, bariatric surgery and GERD occurrence. Further studies based on 3D geometries need to be performed.


Assuntos
Refluxo Gastroesofágico , Laparoscopia , Obesidade Mórbida , Humanos , Qualidade de Vida , Obesidade Mórbida/complicações , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Refluxo Gastroesofágico/epidemiologia , Refluxo Gastroesofágico/etiologia , Refluxo Gastroesofágico/cirurgia , Gastrectomia/efeitos adversos , Gastrectomia/métodos , Laparoscopia/métodos , Resultado do Tratamento , Estudos Retrospectivos
8.
Bioengineering (Basel) ; 10(2)2023 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-36829669

RESUMO

Hollow organs are visceral organs that are hollow tubes or pouches (such as the intestine or the stomach, respectively) or that include a cavity (such as the heart) and which subserve a vital function [...].

9.
Bioengineering (Basel) ; 10(2)2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36829719

RESUMO

Human Fascia Lata (FL) is a connective tissue with a multilayered organization also known as aponeurotic fascia. FL biomechanics is influenced by its composite structure formed by fibrous layers (usually two) separated by loose connective tissue. In each layer, most of the collagen fibers run parallel in a distinct direction (with an interlayer angle that usually ranges from 75-80°), mirroring the fascia's ability to adapt and withstand specific tensile loads. Although FL is a key structure in several musculoskeletal dysfunctions and in tissue engineering, literature still lacks the evidence that proves tissue anisotropy according to predominant collagen fiber directions. For this purpose, this work aims to analyze the biomechanical properties of ex-vivo FL (collected from fresh-frozen human donors) by performing uniaxial tensile tests in order to highlight any differences with respect to loading directions. The experimental outcomes showed a strong anisotropic behavior in accordance with principal collagen fibers directions, which characterize the composite structure. These findings have been implemented to propose a first constitutive model able to mimic the intra- and interlayer interactions. Both approaches could potentially support surgeons in daily practices (such as graft preparation and placement), engineers during in silico simulation, and physiotherapists during musculoskeletal rehabilitation, to customize a medical intervention based on each specific patient and clinical condition.

10.
Artif Organs ; 47(4): 617-639, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36374175

RESUMO

Artificial sphincters (ASs) are used to replace the function of the biological sphincters in case of severe urinary and fecal incontinence (UI and FI), and gastroesophageal reflux disease (GERD). The design of ASs is established on different mechanisms, e.g., magnetic forces or hydraulic pressure, with the final goal to achieve a implantable and durable AS. In clinical practice, the implantation of in-commerce AS is considered a reasonable solution, despite the sub-optimal clinical outcomes. The failure of these surgeries is due to the malfunction of the devices (between 46 and 51%) or the side effects on the biological tissues (more than 38%), such as infection and atrophy. Concentrating on this latter characteristic, particular attention has been given to the interaction between the biological tissues and AS, pointing out the closing mechanism around the duct and the effect on the tissues. To analyze this aspect, an overview of existing commercial/ready-on-market ASs for GERD, UI, and FI, together with the clinical outcomes available from the in-commerce AS, is given. Moreover, this invited review discusses ongoing developments and future research pathways for creating novel ASs. The application of engineering principles and design concepts to medicine enhances the quality of healthcare and improves patient outcomes. In this context, computational methods represent an innovative solution in the design of ASs, proving data on the occlusive force and pressure necessary to guarantee occlusion and avoid tissue damage, considering the coupling between different device sizes and individual variability.


Assuntos
Incontinência Fecal , Incontinência Urinária , Esfíncter Urinário Artificial , Humanos , Incontinência Fecal/cirurgia , Próteses e Implantes , Incontinência Urinária/cirurgia
11.
Bioengineering (Basel) ; 11(1)2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-38247919

RESUMO

Plantar adipose tissue is a connective tissue whose structural configuration changes according to the foot region (rare or forefoot) and is related to its mechanical role, providing a damping system able to adsorb foot impact and bear the body weight. Considering this, the present work aims at fully describing the plantar adipose tissue's behaviour and developing a proper constitutive formulation. Unconfined compression tests and indentation tests have been performed on samples harvested from human donors and cadavers. Experimental results provided the initial/final elastic modulus for each specimen and assessed the non-linear and time-dependent behaviour of the tissue. The different foot regions were investigated, and the main differences were observed when comparing the elastic moduli, especially the final elastic ones. It resulted in a higher level for the medial region (89 ± 77 MPa) compared to the others (from 51 ± 29 MPa for the heel pad to 11 ± 7 for the metatarsal). Finally, results have been used to define a visco-hyperelastic constitutive model, whose hyperelastic component, which describes tissue non-linear behaviour, was described using an Ogden formulation. The identified and validated tissue constitutive parameters could serve, in the early future, for the computational model of the healthy foot.

12.
Ann Biomed Eng ; 50(12): 1911-1922, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35879583

RESUMO

Mechanical stimuli are fundamental in the development of organs and tissues, their growth, regeneration or disease. They influence the biochemical signals produced by the cells, and, consequently, the development and spreading of a disease. Moreover, tumour cells are usually characterized by a decrease in the cell mechanical properties that may be directly linked to their metastatic potential. Thus, recently, the experimental and computational study of cell biomechanics is facing a growing interest. Various experimental approaches have been implemented to describe the passive response of cells; however, cell variability and complex experimental procedures may affect the obtained mechanical properties. For this reason, in-silico computational models have been developed through the years, to overcome such limitations, while proposing valuable tools to understand cell mechanical behaviour. This being the case, we propose a combined continuous-tensegrity finite element (FE) model to analyse the mechanical response of a cell and its subcomponents, observing how every part contributes to the overall mechanical behaviour. We modelled both Atomic Force Microscopy (AFM) indentation and micropipette aspiration techniques, as common mechanical tests for cells and elucidated also the role of cell cytoplasm and cytoskeleton in the global cell mechanical response.


Assuntos
Condrócitos , Citoesqueleto , Fenômenos Biomecânicos , Microscopia de Força Atômica , Condrócitos/fisiologia , Simulação por Computador , Estresse Mecânico , Modelos Biológicos
13.
Biomedicines ; 10(6)2022 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-35740391

RESUMO

Several studies have investigated cartilage degeneration and inflammatory subchondral bone and synovial membrane changes using magnetic resonance (MR) in osteoarthritis (OA) patients. Conversely, there is a paucity of data exploring the role of knee ligaments, infrapatellar fat pad (IFP), and suprapatellar fat pad (SFP) in knee OA compared to post-traumatic cohorts of patients. Therefore, the aim of this study was to analyze the volumetric and morphometric characteristics of the following joint tissues: IFP (volume, surface, depth, femoral and tibial arch lengths), SFP (volume, surface, oblique, antero−posterior, and cranio−caudal lengths), anterior (ACL) and posterior cruciate ligament (PCL) (volume, surface, and length), and patellar ligament (PL) (volume, surface, arc, depth, and length). Eighty-nine MR images were collected in the following three groups: (a) 32 patients with meniscal tears, (b) 29 patients with ACL rupture (ACLR), and (c) 28 patients affected by end-stage OA. Volume, surface, and length of both ACL and PCL were determined in groups a and c. A statistical decrease of IFP volume, surface, depth, femoral and tibial arch lengths was found in end-stage OA compared to patients with meniscal tear (p = 0.002, p = 0.008, p < 0.0001, p = 0.028 and p < 0.001, respectively) and patients with ACLR (p < 0.0001, p < 0.0001, p = 0.008 and p = 0.011, respectively). An increment of volume and surface SFP was observed in group b compared to both groups a and c, while no differences were found in oblique, antero−posterior, and cranio−caudal lengths of SFP among the groups. No statistical differences were highlighted comparing volume, surface, arc, and length of PL between the groups, while PL depth was observed to be decreased in end-OA patients compared with meniscal tear patients (p = 0.023). No statistical differences were observed comparing ACL and PCL lengths between patients undergoing meniscectomy and TKR. Our study confirms that IFP MR morphometric characteristics are different between controls and OA, supporting an important role of IFP in OA pathology and progression in accordance with previously published studies. In addition, PL depth changes seem to be associated with OA pathology. Multivariate analysis confirmed that OA patients had a smaller IFP compared to patients with meniscal tears, confirming its involvement in OA.

14.
Surg Endosc ; 36(11): 7998-8011, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35451669

RESUMO

BACKGROUND: Obesity has become a global epidemic. Bariatric surgery is considered the most effective therapeutic weapon in terms of weight loss and improvement of quality of life and comorbidities. Laparoscopic sleeve gastrectomy (LSG) is one of the most performed procedures worldwide, although patients carry a nonnegligible risk of developing post-operative GERD and BE. OBJECTIVES: The aim of this work is the development of computational patient-specific models to analyze the changes induced by bariatric surgery, i.e., the volumetric gastric reduction, the mechanical response of the stomach during an inflation process, and the related elongation strain (ES) distribution at different intragastric pressures. METHODS: Patient-specific pre- and post-surgical models were extracted from Magnetic Resonance Imaging (MRI) scans of patients with morbid obesity submitted to LSG. Twenty-three patients were analyzed, resulting in forty-six 3D-geometries and related computational analyses. RESULTS: A significant difference between the mechanical behavior of pre- and post-surgical stomach subjected to the same internal gastric pressure was observed, that can be correlated to a change in the global stomach stiffness and a minor gastric wall tension, resulting in unusual activations of mechanoreceptors following food intake and satiety variation after LSG. CONCLUSIONS: Computational patient-specific models may contribute to improve the current knowledge about anatomical and physiological changes induced by LSG, aiming at reducing post-operative complications and improving quality of life in the long run.


Assuntos
Laparoscopia , Obesidade Mórbida , Humanos , Qualidade de Vida , Fenômenos Biomecânicos , Gastrectomia/métodos , Obesidade Mórbida/cirurgia , Obesidade Mórbida/epidemiologia , Estômago/cirurgia , Complicações Pós-Operatórias/epidemiologia , Laparoscopia/métodos , Resultado do Tratamento
15.
Int J Mol Sci ; 23(5)2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35269969

RESUMO

Bladder cancer (BC) is among the most common malignancies in the world and a relevant cause of cancer mortality. BC is one of the most frequent causes for bladder removal through radical cystectomy, the gold-standard treatment for localized muscle-invasive and some cases of high-risk, non-muscle-invasive bladder cancer. In order to restore urinary functionality, an autologous intestinal segment has to be used to create a urinary diversion. However, several complications are associated with bowel-tract removal, affecting patients' quality of life. The present study project aims to develop a bio-engineered material to simplify this surgical procedure, avoiding related surgical complications and improving patients' quality of life. The main novelty of such a therapeutic approach is the decellularization of a porcine small intestinal submucosa (SIS) conduit to replace the autologous intestinal segment currently used as urinary diversion after radical cystectomy, while avoiding an immune rejection. Here, we performed a preliminary evaluation of this acellular product by developing a novel decellularization process based on an environmentally friendly, mild detergent, i.e., Tergitol, to replace the recently declared toxic Triton X-100. Treatment efficacy was evaluated through histology, DNA, hydroxyproline and elastin quantification, mechanical and insufflation tests, two-photon microscopy, FTIR analysis, and cytocompatibility tests. The optimized decellularization protocol is effective in removing cells, including DNA content, from the porcine SIS, while preserving the integrity of the extracellular matrix despite an increase in stiffness. An effective sterilization protocol was found, and cytocompatibility of treated SIS was demonstrated from day 1 to day 7, during which human fibroblasts were able to increase in number and strongly organize along tissue fibres. Taken together, this in vitro study suggests that SIS is a suitable candidate for use in urinary diversions in place of autologous intestinal segments, considering the optimal results of decellularization and cell proliferation. Further efforts should be undertaken in order to improve SIS conduit patency and impermeability to realize a future viable substitute.


Assuntos
Neoplasias da Bexiga Urinária , Animais , DNA , Humanos , Mucosa Intestinal , Intestino Delgado , Qualidade de Vida , Suínos , Engenharia Tecidual/métodos , Neoplasias da Bexiga Urinária/cirurgia
16.
J Mech Behav Biomed Mater ; 125: 104914, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34715641

RESUMO

Gastric diseases are one of the most relevant healthcare problems worldwide. Interventions and therapies definition/design mainly derive from biomedical and clinical expertise. Computational biomechanics, with particular regard to the finite element method, provides hard-to-measure quantities during in-vivo tests, such as strain and stress distribution, leading to a more comprehensive and promising approach to improve the effectiveness of many different clinical activities. However, reliable finite element models of biological organs require appropriate constitutive formulations of building tissues, whose parameters identification needs an experimental campaign consisting in different tests on human tissues and organs. The aim of the reported here research activities was the identification of mechanical properties of human gastric tissues. Human gastric specimens were tested at tissue, sub-structural and structural levels, by tensile, membrane indentation and inflation tests, respectively. On the other hand, animal experimentations on tissue layers from literature pointed out the mechanical response at sub-tissue level during tensile loading conditions. In detail, the analysis of experimental results at sub-tissue and tissue levels led to a fibre-reinforced visco-hyperelastic constitutive formulation and to the identification of gastric layers mechanical behaviour. Results from experimentations on human samples were coupled with data derived from animal models. Data from sub-structural and structural experimentations were exploited to upgrade and validate the constitutive formulations and parameters. The developed investigations led to a reliable constitutive framework of human gastric tissues that both describe stomach mechanical functionality and allow computational investigations. Indeed, the comparisons among average computational data and experimental medians provided the following RMSEs (Root Mean Square Errors): 0.89 N, 0.15 N for corpus and fundus during membrane indentation test, respectively, and 0.44 kPa during inflation test. Accounting for the magnitude of experimental and computational data, the RMSEs can be considered low and acceptable because they concerned biological samples. In fact, biological tissues and structures are affected by a high inherent inter-samples' variability, which is detectable in both the geometrical configuration and the mechanical behaviour. The specific values of the here reported RMSEs ensured the reliability of the achieved parameters and the quality of the overall developed procedure. Reliable computational models of the gastric district could become efficient clinical tools to find out the main crucial aspects of bariatric procedures, such as the mechanical stimulation of gastric mechano-receptors. Moreover, the methods of computational biomechanics will permit to run the preliminary tests of new and innovative bariatric procedures, on one hand, predicting the successful rate and the effectiveness, and, on other hand, reducing the use of animal testing.


Assuntos
Estômago , Fenômenos Biomecânicos , Biofísica , Humanos , Reprodutibilidade dos Testes
17.
J Biomech ; 131: 110931, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34972018

RESUMO

The infrapatellar fat pad (IFP) is an adipose tissue present in the knee that lies between the patella, femur, meniscus and tibia, filling the space between these structures. IFP facilitates the distribution of the synovial fluid and may act to absorb impulsive actions generated through the joint. IFP in osteoarthritis (OA) pathology undergoes structural changes characterized by inflammation, hypertrophy and fibrosis. The aim of the present study is to analyze the mechanical behavior of the IFP in patients affected by end-stage OA. A specific test fixture was designed and indentation tests were performed on IFP specimens harvested from OA patients who underwent total knee arthroplasty. Experiments allowed to assess the typical features of mechanical response, such as non-linear stress-strain behavior and time-dependent effects. Results from mechanical experimentations were implemented within the framework of a visco-hyperelastic constitutive theory, with the aim to provide data for computational modelling of OA IFP role in knee mechanics. Initial and final indentation stiffness were calculated for all subjects and statistical results reveled that OA IFP mechanics was not significantly influenced by gender, BMI and sample preparation. OA IFP mechanical behavior was also compared to that of other adipose tissues. OA IFP appeared to be a stiffer adipose tissue compared to subcutaneous, visceral adipose tissues and heel fat pads. It is reasonable that fibrosis induces a modification of the tissue destabilizing the normal distribution of forces in the joint during movement, causing a worsening of the disease.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Tecido Adiposo , Humanos , Articulação do Joelho , Patela
18.
BMC Vet Res ; 17(1): 340, 2021 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-34711207

RESUMO

BACKGROUND: Cornea is a composite tissue exhibiting nonlinear and time-dependent mechanical properties. Corneal ulcers are one of the main pathologies that affect this tissue, disrupting its structural integrity and leading to impaired functions. In this study, uniaxial tensile and stress-relaxation tests are developed to evaluate stress-strain and time-dependent mechanical behaviour of porcine corneas. RESULTS: The samples are split in two groups: some corneas are analysed in an unaltered state (healthy samples), while others are injured with alkaline solution to create an experimental ulcer (lesioned samples). Furthermore, within each group, corneas are examined in two conditions: few hours after the enucleation (fresh samples) or after 7 days in a specific culture medium for the tissue (cultured samples). Finally, another condition is added: corneas from all the groups undergo or not a cross-linking treatment. In both stress-strain and stress-relaxation tests, a weakening of the tissue is observed due to the imposed conditions (lesion, culture and treatment), represented by a lower stiffness and increased stress-relaxation. CONCLUSIONS: Alkali-induced corneal stromal melting determines changes in the mechanical response that can be related to a damage at microstructural level. The results of the present study represent the basis for the investigation of traditional and innovative corneal therapies.


Assuntos
Córnea/efeitos dos fármacos , Córnea/fisiologia , Úlcera da Córnea/veterinária , Técnicas de Cultura de Órgãos/veterinária , Doenças dos Suínos/patologia , Animais , Úlcera da Córnea/induzido quimicamente , Úlcera da Córnea/patologia , Suínos , Doenças dos Suínos/induzido quimicamente
19.
Updates Surg ; 73(6): 2253-2262, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33817769

RESUMO

LSG is one of the most performed bariatric procedures worldwide. It is a safe and effective operation with a low complication rate. Unsatisfactory weight loss/regain may occur, suggesting that the operation design could be improved. A bioengineering approach might significantly help in avoiding the most common complications. Computational models of the sleeved stomach after LSG were developed according to bougie size (range 27-54 Fr). The endoluminal pressure and the basal volume were computed at different intragastric pressures. At an inner pressure of 22.5 mmHg, the basal volume of the 54 Fr configuration was approximately 6 times greater than that of the 27 Fr configuration (57.92 ml vs 9.70 ml). Moreover, the elongation distribution of the gastric wall was assessed to quantify the effect on mechanoreceptors impacting satiety by differencing regions and layers. An increasing trend in elongation strain with increasing bougie size was observed in all cases. The most stressed region and layer were the antrum (approximately 25% higher stress than that in the corpus at 37.5 mmHg) and mucosa layer (approximately 7% higher stress than that in the muscularis layer at 22.5 mmHg), respectively. In addition, the pressure-volume behaviors were reported. Computational models and bioengineering methods can help to quantitatively identify some critical aspects of the "design" of bariatric operations to plan interventions, and predict and increase the success rate. Moreover, computational tools can support the development of innovative bariatric procedures, potentially skipping invasive approaches.


Assuntos
Cirurgia Bariátrica , Laparoscopia , Obesidade Mórbida , Gastrectomia , Humanos , Obesidade Mórbida/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Redução de Peso
20.
Bioengineering (Basel) ; 7(4)2020 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-33317122

RESUMO

BACKGROUND: The stomach is a hollow organ of the gastrointestinal tract, on which bariatric surgery (BS) is performed for the treatment of obesity. Even though BS is the most effective treatment for severe obesity, drawbacks and complications are still present because the intervention design is largely based on the surgeon's expertise and intraoperative decisions. Bioengineering methods can be exploited to develop computational tools for more rational presurgical design and planning of the intervention. METHODS: A computational mechanical model of the stomach was developed, considering the actual complexity of the biological structure, as the nonhomogeneous and multilayered configuration of the gastric wall. Mechanical behavior was characterized by means of an anisotropic visco-hyperelastic constitutive formulation of fiber-reinforced conformation, nonlinear elastic response, and time-dependent behavior, which assume the typical features of gastric wall mechanics. Model applications allowed for an analysis of the influence of BS techniques on stomach mechanical functionality through different computational analyses. RESULTS: Computational results showed that laparoscopic sleeve gastrectomy and endoscopic sleeve gastroplasty drastically alter stomach capacity and stiffness, while laparoscopic adjustable gastric banding modestly affects stomach stiffness and capacity. Moreover, the mean elongation strain values, which are correlated to the mechanical stimulation of gastric receptors, were elevated in laparoscopic adjustable gastric banding compared to other procedures. CONCLUSIONS: The investigation of stomach mechanical response through computational models provides information on different topics such as stomach capacity and stiffness and the mechanical stimulation of gastric receptors, which interact with the brain to control satiety. These data can provide reliable support to surgeons in the presurgical decision-making process.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA