Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Sep Sci ; 47(9-10): e2400142, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38726732

RESUMO

Catechins, renowned for their antioxidant properties and health benefits, are commonly present in beverages, particularly tea and wine. An efficient and cost-effective salting-out assisted liquid-liquid extraction (SALLE) method has been developed and validated for the simultaneous determination of six catechins and caffeine in tea and wine samples using high-performance liquid chromatography-ultraviolet (HPLC-UV). This method demonstrates outstanding performance: linearity (1-120 µg/mL, r2 > 0.999), accuracy (96.5%-103.4% recovery), and precision (≤14.7% relative standard deviation), meeting validation requirements set by the US Food and Drug Administration. The reduced sample size (0.1 g) minimizes matrix interferences and costs without compromising sensitivity. All analytes were detected in Camellia sinensis teas, with green tea displaying the highest total catechin content (47.5-100.1 mg/mL), followed by white and black teas. Analysis of wine samples reveals the presence of catechin in all red and white wines, and epigallocatechin gallate in all red wine samples, highlighting the impact of winemaking processes on catechin content. The SALLE-HPLC-UV approach represents a green alternative by eliminating organic waste, surpassing conventional dilution methods in specificity and sensitivity for catechin determination. AGREEprep assessment emphasizes the strengths of the SALLE procedure, including material reusability, throughput efficiency, minimal sample requirements, low energy consumption, and the absence of organic waste generation.


Assuntos
Cafeína , Catequina , Extração Líquido-Líquido , Chá , Vinho , Cromatografia Líquida de Alta Pressão/métodos , Vinho/análise , Cafeína/análise , Catequina/análise , Chá/química , Extração Líquido-Líquido/métodos , Espectrofotometria Ultravioleta , Raios Ultravioleta
2.
Anal Chim Acta ; 1288: 342164, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38220296

RESUMO

Infant formulae are the only possible alternative to breastfeeding during the first year of life, so it is crucial to assure their innocuousness. Infant formula undergoes heat treatments to ensure safety and shelf life. However, such processes impact health as they lead to the formation of malondialdehyde, acrolein, and α-dicarbonyl compounds, related to Maillard reaction. Thus, there is a need for improved analytical methods to ensure the safety, quality, and nutritional value of infant formulae, and also exploring the potential of specific compounds as indicators for quality control and monitoring purposes. We developed and validated a novel, efficient, and cost-effective method using gas-diffusion microextraction for the simultaneous quantification of carbonyl compounds in infant formula. Malondialdehyde, acrolein, glyoxal, methylglyoxal, and diacetyl were detected as o-phenylenediamine derivatives using HPLC with UV detection. Parameters influencing extraction efficiency were studied using an asymmetric screening design. The validated method has shown excellent linearity, sensitivity, accuracy, and precision. It was applied to analyze 26 infant formula samples, including starter, follow-up, and special formulated powdered infant formula. Methylglyoxal was found in all samples (0.201-3.153 µg mL-1), while malondialdehyde was present only in certain starter formulas (1.033-1.802 µg mL-1). Acrolein (0.510-3.246 µg mL-1), glyoxal (0.109-1.253 µg mL-1), and diacetyl (0.119-2.001 µg mL-1) were detected in various sample types. Principal components and hierarchical cluster analyses have showcased distinct sample clustering based on analyte contents. This study presents a novel methodology for the analysis of markers of thermal treatment and oxidative stability in infant formula. It contributes to the characterization of the products' composition and quality control of infant formulae, thereby enhancing their safety and nutritional adequacy. This study also presents the first reported quantification of acrolein in infant formula and introduces the application of the acrolein-o-phenylenediamine derivative for food analysis.


Assuntos
Fórmulas Infantis , Fenilenodiaminas , Aldeído Pirúvico , Lactente , Humanos , Aldeído Pirúvico/análise , Fórmulas Infantis/química , Cromatografia Líquida de Alta Pressão/métodos , Acroleína/análise , Diacetil , Glioxal/análise , Malondialdeído , Estresse Oxidativo
3.
Anal Chim Acta ; 1239: 340712, 2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36628717

RESUMO

A simple, fast and effective direct method based on HPLC-APCI-QqQ-MS/MS has been developed to simultaneously determine four 3-monochloropropane-1,2-diol monoesters (3-MCPDE) esterified with palmitic, linoleic, stearic, and oleic acid, and two glycidyl esters (GE) with palmitic and oleic acid in margarine and olive oil using a QuEChERS approach. Factors affecting the efficiency of the extraction process were assessed, including type and amount of salt, extraction solvent, test portion amount, and clean-up sorbent. The analytical method was validated according to Food and Drug Administration (FDA) guidelines using matrix-matched calibration with internal standards and showed good results in terms of linearity (r2 > 0.9992), accuracy (80

Assuntos
Espectrometria de Massas em Tandem , alfa-Cloridrina , Espectrometria de Massas em Tandem/métodos , alfa-Cloridrina/análise , Margarina/análise , Ésteres/análise , Ácido Oleico/análise , Azeite de Oliva/análise , Óleos de Plantas/análise , Contaminação de Alimentos/análise
4.
Food Chem ; 403: 134423, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36183472

RESUMO

A novel, fast, and cost-effective indirect enzymatic method was successfully developed to assess the total 3-monochloropropane-1,2-diol (3-MCPD) in canned food's oil fraction by the action of Burkholderia cepacia lipase. The total 3-MCPD were derivatized with n-Heptafluorobutyrylimidazole (HFBI) for GC-MS analysis during dispersive liquid-liquid microextraction (DLLME). An asymmetrical 2213//8 screening design was used to study the influence of critical factors on the method's effectiveness. The analytical features of the proposed method were assessed following Food and Drug Administration (FDA) guidelines using extra virgin olive oil (EVOO) as a blank sample. Outstanding results were achieved in terms of linearity (r2 = 0.9995), sensitivity, precision (2.1 % to 10.4 % RSD), and accuracy (98.7 % ≤ recovery ≤ 101.9 %). Method efficacy was tested by comparing the results of 10 edible oils for total 3-MCPD with those reported in previous works. A total of 41 samples were analyzed. The lowest 3-MCPD content was found in samples of albacore canned in EVOO oil, while the highest amounts were found in albacore, mackerel, and Atlantic saury samples, all preserved in refined sunflower oil.


Assuntos
alfa-Cloridrina , alfa-Cloridrina/análise , Ésteres/análise , Azeite de Oliva/análise , Cromatografia Gasosa-Espectrometria de Massas , Óleos de Peixe , Óleos de Plantas/análise
5.
J Chromatogr A ; 1663: 462768, 2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-34974368

RESUMO

New psychoactive substances (NPS) continue to emerge in the drug market every year, becoming a global threat to public health and safety. These compounds are mostly synthetic cannabinoids and designer cathinones. However, synthetic opioids have appeared on the recreational drug markets in recent years, particularly fentanyl and its derivatives ("fentanyls"). Fentanyl and its analogs are related to harmful intoxications and an increase in opioid-related mortality in many countries, such as in the United States and Europe in the last years. Taking the drug related global crisis into consideration, this work developed and validated an effective and sensitive method based on fabric phase sorptive extraction (FPSE) followed by gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of 11 fentanyl analogs in oral fluid samples. The extraction was carried out using a sol-gel Carbowax 20 M sorbent immobilized on 100% cellulose fabric substrate and using ethyl acetate as the desorption solvent. The limits of detection (LODs) and quantification (LOQs) ranged from 1 to 15 ng mL-1 and 5 to 50 ng mL-1, respectively. Intra-day and inter-day precision were found within 8.2% and 8.6%, respectively, while accuracy ranged from -5.5 to 9.1%, in accordance with the established criteria. The absolute recovery values were in the range of 94.5%-109.1%. The validated method demonstrated its great potential to detect and quantify fentanyl analogs in possible forensic work and off-site analysis in road traffic cases.


Assuntos
Analgésicos Opioides , Drogas Ilícitas , Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção , Têxteis
6.
Carbohydr Polym ; 220: 43-52, 2019 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-31196549

RESUMO

An environmentally friendly and low-cost material based on cellulose filter paper modified with ß-cyclodextrin (ß-CD) was designed to uptake and elute drugs for water purification. To carry out the work, a ß-CD derivative was first obtained through reaction of ß-CD with N-(hydroxymethyl) acrylamide (NMA), and then ß-CD-NMA was grafted on cellulose by means of the Fenton's reaction. The CD-grafted cellulose paper was characterized by ATR-FTIR analysis, SEM images, and mechanical properties. CD-functionalized (F1) and non-functionalized (NF) papers were tested in aqueous media containing an antibiotic (ciprofloxacin) or a non-steroidal anti-inflammatory drug (diclofenac) covering a wide range of salinity levels. Ciprofloxacin was similarly adsorbed by both papers through ionic interactions, while diclofenac was selectively and remarkably captured by the CD-functionalized filter (up to 25 mg g-1 from saline medium under biorelevant conditions; ca. 60 mg g-1 Langmuir isotherm model). Effects of diclofenac concentration, volume of medium, and incubation time on the amount adsorbed were investigated in detail. Elution tests involved the combination of several organic solvents and alkaline solutions and revealed that acetonitrile:NaOH 10 mM aq. solution (50:50, v/v) allows for an effective recovery of the previously trapped diclofenac. Application of ultrasounds shortened the process to 10 min. Reusability of F1 papers was also evaluated. Overall, the CD-grafted cellulose paper appears as a suitable material for bioremediation and analytical purposes.


Assuntos
Anti-Inflamatórios não Esteroides/isolamento & purificação , Celulose/análogos & derivados , Ciclodextrinas/química , Diclofenaco/isolamento & purificação , Filtração/instrumentação , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/instrumentação , Água/análise , Anti-Inflamatórios não Esteroides/química , Biodegradação Ambiental , Ciprofloxacina/química , Ciprofloxacina/isolamento & purificação , Diclofenaco/química , Salinidade , Poluentes Químicos da Água/química
7.
J Sep Sci ; 42(11): 2053-2061, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30945416

RESUMO

The growing use of antidepressants in recent years has led to their increasing presence in forensic analyses. In this work, microextraction by packed sorbent followed by ultra-performance liquid chromatography with photodiode array detection provided a fast method for determining the antidepressants mirtazapine, venlafaxine, escitalopram, fluoxetine, fluvoxamine, and sertraline in human urine. The microextraction conditions (viz., type of sorbent, number of draw-eject extraction cycles or strokes, sample volume and pH, and type and volume of washing solution and eluent) were optimized by using an experimental design. The ensuing analytical method was validated in terms of linearity (25-1000 ng/mL urine), limit of detection (lower than 7.1 ng/mL), limit of quantification (25 ng/mL), precision (4.7-15.1% as relative standard deviation), and accuracy (80.4-126.1% as mean recovery for four replicate determinations). The proposed method allowed the six target antidepressants to be determined at concentrations from therapeutic to toxic levels. The application to small volumes (300 µL) of urine afforded fast extraction of the analytes and provided results on a par with those of existing clinical and forensic alternatives.


Assuntos
Antidepressivos/isolamento & purificação , Antidepressivos/urina , Microextração em Fase Líquida/métodos , Cromatografia Líquida de Alta Pressão , Fluoxetina/análise , Fluoxetina/isolamento & purificação , Humanos , Limite de Detecção
8.
Anal Bioanal Chem ; 409(11): 2885-2892, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28190107

RESUMO

In this work, a simple methodology was developed for the extraction and determination of free formaldehyde content in cork agglomerate samples. For the first time, gas-diffusion microextraction was used for the extraction of volatile formaldehyde directly from samples, with simultaneous derivatization with acetylacetone (Hantzsch reaction). The absorbance of the coloured solution was read in a spectrophotometer at 412 nm. Different extraction parameters were studied and optimized (extraction temperature, sample mass, volume of acceptor solution, extraction time and concentration of derivatization reagent) by means of an asymmetric screening. The developed methodology proved to be a reliable tool for the determination of formaldehyde in cork agglomerates with the following suitable method features: low LOD (0.14 mg kg-1) and LOQ (0.47 mg kg-1), r 2 = 0.9994, and intraday and interday precision of 3.5 and 4.9%, respectively. The developed methodology was applied to the determination of formaldehyde in different cork agglomerate samples, and contents between 1.9 and 9.4 mg kg-1 were found. Furthermore, formaldehyde was also determined by the standard method EN 717-3 for comparison purposes; no significant differences between the results of both methods were observed. Graphical abstract Representation of the GDME system and its main components.

9.
Anal Bioanal Chem ; 408(24): 6845-56, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27488280

RESUMO

Polymers for recovery/removal of the antimicrobial agent oxytetracycline (OTC) from aqueous media were developed with use of computational design and molecular imprinting. 2-Hydroxyethyl methacrylate, 2-acrylamide-2-methylpropane sulfonic acid (AMPS), and mixtures of the two were chosen according to their predicted affinity for OTC and evaluated as functional monomers in molecularly imprinted polymers and nonimprinted polymers. Two levels of AMPS were tested. After bulk polymerization, the polymers were crushed into particles (200-1000 µm). Pressurized liquid extraction was implemented for template removal with a low amount of methanol (less than 20 mL in each extraction) and a few extractions (12-18 for each polymer) in a short period (20 min per extraction). Particle size distribution, microporous structure, and capacity to rebind OTC from aqueous media were evaluated. Adsorption isotherms obtained from OTC solutions (30-110 mg L(-1)) revealed that the polymers prepared with AMPS had the highest affinity for OTC. The uptake capacity depended on the ionic strength as follows: purified water > saline solution (0.9 % NaCl) > seawater (3.5 % NaCl). Polymer particles containing AMPS as a functional monomer showed a remarkable ability to clean water contaminated with OTC. The usefulness of the stationary phase developed for molecularly imprinted solid-phase extraction was also demonstrated. Graphical Abstract Selection of functional monomers by molecular modeling renders polymer networks suitable for removal of pollutants from contaminated aqueous environments, under either dynamic or static conditions.


Assuntos
Antibacterianos/isolamento & purificação , Impressão Molecular/métodos , Oxitetraciclina/isolamento & purificação , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água/métodos , Acrilamidas/química , Adsorção , Alcanossulfonatos/química , Água Subterrânea/análise , Metacrilatos/química , Modelos Moleculares , Polimerização
10.
J Sep Sci ; 38(19): 3428-34, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26205350

RESUMO

Chloropropanols are processing toxicants with a potential risk to human health due to the increased intake of processed foods. A rapid and efficient method for the determination of three chloropropanols in human plasma was developed using ultrasound-assisted dispersive liquid-liquid microextraction. The method involved derivatization and extraction in one step followed by gas chromatography with tandem mass spectrometry analysis. Parameters affecting extraction, such as sample pH, ionic strength, type and volume of dispersive and extraction solvents were optimized by response surface methodology using a pentagonal design. The linear range of the method was 5-200 ng/mL for 1,3-dichloro-2-propanol, 10-200 ng/mL for 2,3-dichloro-2-propanol and 10-400 ng/mL for 3-chloropropane-1,2-diol with the determination coefficients between 0.9989 and 0.9997. The limits of detection were in the range of 0.3-3.2 ng/mL. The precision varied from 1.9 to 10% relative standard deviation (n = 9). The recovery of the method was between 91 and 101%. Advantages such as low consumption of organic solvents and short time of analysis make the method suitable for the biomonitoring of chloropropanols.

11.
Anal Bioanal Chem ; 407(17): 4927-48, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25910881

RESUMO

This review focuses on the fundamentals of stimuli-responsive materials and their applications to three common separation techniques, namely extraction, chromatography, and electrophoresis. Although still little investigated, materials that switch their affinity for the analyte on and off as a function of tiny changes in physical and biochemical variables offer relevant advantages for analyte extraction, concentration, and separation. Temperature and/or pH-responsive polymers in the form of chains or networks, which are dispersed in the sample as free entities or after being grafted onto beads (which may incorporate magnetic cores), enable quantitative capture and/or elution of the analyte under mild conditions and without needing organic solvents. Regarding liquid-chromatography separation, responsive stationary phases enable the implementation of "all-in-water" procedures in which retention times are modulated by means of temperature or pH gradients. Other stimuli that can be externally applied, for example light or magnetic fields, can also be used for efficient extraction or separation of the target substance without altering the composition of the sample matrix. Moreover, stimuli-responsiveness enables straightforward recycling of solid and/or stationary phases for a prolonged lifetime. Improved understanding of the phase transitions of stimuli-responsive materials and design of suitable formats for analytical applications should enable wider and more successful application of stimuli-responsive materials in analytical separations.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Eletroforese Capilar/métodos , Polímeros/química , Extração em Fase Sólida/métodos , Concentração de Íons de Hidrogênio , Impressão Molecular/métodos
12.
J Chromatogr A ; 1296: 214-25, 2013 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-23714360

RESUMO

Pressurized liquid extraction (PLE) is an exhaustive technique used for the extraction of analytes from solid samples. Temperature, pressure, solvent type and volume, and the addition of other reagents notably influence the efficiency of the extraction. The analytical applications of this technique can be improved by coupling with appropriate derivatization reactions. The aim of this review is to discuss the recent applications of the sequential combination of PLE with derivatization and the approaches that involve simultaneous extraction and in situ derivatization. The potential of the latest developments to the trace analysis of environmental, food and biological samples is also analyzed.


Assuntos
Extração Líquido-Líquido/métodos , Compostos Orgânicos/química , Compostos Orgânicos/análise , Compostos Orgânicos/isolamento & purificação , Pressão , Temperatura
13.
J Sep Sci ; 36(8): 1446-54, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23505248

RESUMO

The performance of microwave-assisted extraction and HPLC with photodiode array detection method for determination of six analgesic and anti-inflammatory drugs from plasma and urine, is described, optimized, and validated. Several parameters affecting the extraction technique were optimized using experimental designs. A four-factor (temperature, phosphate buffer pH 4.0 volume, extraction solvent volume, and time) hybrid experimental design was used for extraction optimization in plasma, and three-factor (temperature, extraction solvent volume, and time) Doehlert design was chosen to extraction optimization in urine. The use of desirability functions revealed the optimal extraction conditions as follows: 67°C, 4 mL phosphate buffer pH 4.0, 12 mL of ethyl acetate and 9 min, for plasma and the same volume of buffer and ethyl acetate, 115°C and 4 min for urine. Limits of detection ranged from 4 to 45 ng/mL in plasma and from 8 to 85 ng/mL in urine. The reproducibility evaluated at two concentration levels was less than 6.5% for both specimens. The recoveries were from 89 to 99% for plasma and from 83 to 99% for urine. The proposed method was successfully applied in plasma and urine samples obtained from analgesic users.


Assuntos
Analgésicos/isolamento & purificação , Anti-Inflamatórios/isolamento & purificação , Micro-Ondas , Analgésicos/sangue , Analgésicos/urina , Anti-Inflamatórios/sangue , Anti-Inflamatórios/urina , Cromatografia Líquida de Alta Pressão , Humanos , Espectrofotometria Ultravioleta , Propriedades de Superfície
14.
Anal Chim Acta ; 767: 88-96, 2013 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-23452791

RESUMO

A simple and efficient ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) method has been developed for the determination of seven benzodiazepines (alprazolam, bromazepam, clonazepam, diazepam, lorazepam, lormetazepam and tetrazepam) in human plasma samples. Chloroform and methanol were used as extractant and disperser solvents, respectively. The influence of several variables (e.g., type and volume of dispersant and extraction solvents, pH, ultrasonic time and ionic strength) was carefully evaluated and optimized, using an asymmetric screening design 3(2)4(2)//16. Analysis of extracts was performed by ultra-performance liquid chromatography coupled with photodiode array detection (UPLC-PDA). Under the optimum conditions, two reversed-phases, Shield RP18 and C18 columns were successfully tested, obtaining good linearity in a range of 0.01-5µgmL(-1), with correlation coefficients r>0.996. Quantification limits ranged between 4.3-13.2ngmL(-1) and 4.0-14.8ngmL(-1), were obtained for C18 and Shield RP18 columns, respectively. The optimized method exhibited a good precision level, with relative standard deviation values lower than 8%. The recoveries studied at two spiked levels, ranged from 71 to 102% for all considered compounds. The proposed method was successfully applied to the analysis of seven benzodiazepines in real human plasma samples.


Assuntos
Benzodiazepinas/sangue , Microextração em Fase Líquida , Raios Ultravioleta , Cromatografia Líquida de Alta Pressão/instrumentação , Humanos , Microextração em Fase Líquida/instrumentação
15.
J Appl Toxicol ; 33(8): 740-5, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22337121

RESUMO

A simple method is presented for the simultaneous determination of morphine, 6-acetylmorphine, codeine, cocaine, benzoylecgonine, cocaethylene, methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) in vitreous humor by high-performance liquid chromatography with photodiode array detector after solid-phase extraction with Oasis® HLB cartridges and dichloromethane as eluent. The chromatographic process was carried out using an XTerra® RP8 column (250 × 4.6 mm i.d., 5 µm particle size) and a mobile phase composed of acetonitrile and pH 6.5 phosphate buffer in gradient mode. A linear response from the detector was obtained within the concentration range of 0.1-4 µg ml(-1) , with correlation coefficients higher than 0.99. The limits of detection were lower than 30 ng ml(-1) for all the drugs studied, the coefficients of variation fluctuated between 0.1 and 12.4%, and the average recoveries were higher than 78% for all the drugs except for EDDP, with a value of 66.4%. Finally, the proposed method was applied to 15 vitreous humor samples coming from individuals who had died from opiate and/or cocaine overdose, showing consumption of cocaine in 14 cases, methadone in five cases and heroin in three cases. Average concentrations of 0.30 µg ml(-1) for morphine, 0.24 µg ml(-1) for 6-acetylmorphine, 0.10 µg ml(-1) for codeine, 0.81 µg ml(-1) for cocaine, 1.26 µg ml(-1) for benzoylecgonine, 0.15 µg ml(-1) for cocaethylene, 0.11 µg ml(-1) for methadone and 0.68 µg ml(-1) for EDDP were obtained.


Assuntos
Drogas Ilícitas/isolamento & purificação , Extração em Fase Sólida/métodos , Corpo Vítreo/química , Cromatografia Líquida de Alta Pressão/métodos , Cocaína/análogos & derivados , Cocaína/isolamento & purificação , Codeína/isolamento & purificação , Humanos , Derivados da Morfina/isolamento & purificação , Pirrolidinas/isolamento & purificação , Reprodutibilidade dos Testes
16.
J Sep Sci ; 35(21): 2866-74, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23034871

RESUMO

Chemicals are widely used in aquaculture and one of the main recipients of these analytes is the aquatic environment. The aim of this work was to develop and validate a simple and sensitive method for the determination of multiclass chemotherapeutic agents in farmed fish and shellfish using matrix solid-phase dispersion and liquid chromatography-tandem mass spectrometry. Residues of azamethiphos, three avermectins, two carbamates, and two benzoylureas were extracted from samples using silica gel as clean-up adsorbent and 0.5% acetic acid in acetonitrile as elution solvent. The extraction conditions were investigated and optimized using an experimental design. Mass spectrometry detection was carried out in positive electrospray ionization mode with multiple-reaction monitoring scan (except for benzoylurea family). Matrix-matched standards were used for the drugs quantification. Good linearity (R(2) ≥ 0.996) was observed in the range of 5-500 µg kg(-1). Limits of detection were in the range of 1.5-3.7 µg kg(-1). Recoveries from salmon samples spiked with veterinary drugs were in the range 84.9-118%. Precision was satisfactory since relative standard deviations were lower than 10.6%. The method can be successfully applied for the analysis of fish and shellfish from aquaculture.


Assuntos
Cromatografia Líquida/métodos , Praguicidas/análise , Alimentos Marinhos/análise , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Drogas Veterinárias/análise , Animais , Doenças dos Peixes/tratamento farmacológico , Peixes , Contaminação de Alimentos/análise , Limite de Detecção , Praguicidas/isolamento & purificação , Frutos do Mar/análise , Drogas Veterinárias/isolamento & purificação , Drogas Veterinárias/uso terapêutico , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação
17.
J Sep Sci ; 34(19): 2697-704, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21818849

RESUMO

A sensitive and rapid derivatization method for the simultaneous determination of 1,3-dichloro-2-propanol (1,3-DCP) and 3-chloropropane-1,2-diol (3-MCPD) in water samples has been developed. The aim was to research the optimal conditions of the derivatization process for two selected reagents. A central composite design was used to determine the influence of derivatization time, derivatization temperature and reagent volume. A global desirability function was applied for multi-response optimization. The analysis was performed by gas chromatography-mass spectrometry. During the optimization of the extraction procedure, four different types of solid-phase extraction (SPE) columns were tested. It was demonstrated that the Oasis HLB cartridge produced the best recoveries of the target analytes. The pH value and the salinity were investigated using a Doehlert design. The best results for the SPE of both analytes were obtained with 1.5 g of NaCl and pH 6. The proposed method provides high sensitivity, good linearity (R(2)≥0.999) and repeatability (relative standard deviations % between 2.9 and 3.4%). Limits of detection and quantification were in the range of 1.4-11.2 ng/mL and 4.8-34.5 ng/mL, respectively. Recoveries obtained for water samples were ca. 100% for 1,3-DCP and 3-MCPD. The method has been successfully applied to the analysis of different samples including commercially bottled water, an influent and effluent sewage.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Glicerol/análogos & derivados , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , alfa-Cloridrina/análogos & derivados , Glicerol/análise , Glicerol/isolamento & purificação , Esgotos/química , alfa-Cloridrina/análise , alfa-Cloridrina/isolamento & purificação
18.
Anal Bioanal Chem ; 401(7): 2177-86, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21822971

RESUMO

Robust and simple validated analytical methods are required in postmortem toxicology to confirm immunoassay screening analysis of drugs of abuse. In this work, microwave-assisted extraction (MAE) was evaluated as an alternative method for extraction of target compounds such as cocaine, benzoylecgonine, cocaethylene, morphine, codeine, 6-monoacetylmorphine, methadone, and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine from vitreous humor. The MAE procedure parameters, namely, extraction temperature, time, and solvent volume, were optimized using a central composite design and applying desirability functions. The optimal conditions for extraction were 80 °C, 8 min, and 15 mL of dichloromethane solvent. The MAE-high-performance liquid chromatography-diode-array detection method was validated, showing its capability for the detection of concentrations in the range from 33 to 76 ng mL(-1) and recoveries in the range from 87 to 99.3% for all drugs. The MAE-based method was tested for 15 vitreous humor samples from forensic cases and its performance was compared with that of a solid-phase extraction method previously developed by our group. In general, better recovery and precision were achieved with the use of the MAE-based procedure.


Assuntos
Drogas Ilícitas/análise , Micro-Ondas , Derivados da Morfina/análise , Corpo Vítreo/química , Corpo Vítreo/efeitos dos fármacos , Cromatografia Líquida de Alta Pressão , Humanos , Extração em Fase Sólida , Solventes , Transtornos Relacionados ao Uso de Substâncias
19.
Int J Mol Sci ; 12(7): 4327-47, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21845081

RESUMO

Template removal is a critical step in the preparation of most molecularly imprinted polymers (MIPs). The polymer network itself and the affinity of the imprinted cavities for the template make its removal hard. If there are remaining template molecules in the MIPs, less cavities will be available for rebinding, which decreases efficiency. Furthermore, if template bleeding occurs during analytical applications, errors will arise. Despite the relevance to the MIPs performance, template removal has received scarce attention and is currently the least cost-effective step of the MIP development. Attempts to reach complete template removal may involve the use of too drastic conditions in conventional extraction techniques, resulting in the damage or the collapse of the imprinted cavities. Advances in the extraction techniques in the last decade may provide optimized tools. The aim of this review is to analyze the available data on the efficiency of diverse extraction techniques for template removal, paying attention not only to the removal yield but also to MIPs performance. Such an analysis is expected to be useful for opening a way to rational approaches for template removal (minimizing the costs of solvents and time) instead of the current trial-and-error methods.


Assuntos
Impressão Molecular , Polímeros/química , Adsorção , Hemoglobinas/química , Hemoglobinas/metabolismo , Humanos , Micro-Ondas , Solventes/química , Sonicação
20.
J Sep Sci ; 31(15): 2882-90, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18666180

RESUMO

A sensitive and efficient solid-phase microextraction (SPME) method for the determination of organophosphorous (OPPs) and pyrethroid pesticides (Pyrs) in aquaculture-seawater samples by using GC with MS/MS (GC-MS/MS) was developed. Dichlorvos and chlorpyrifos (OPPs); permethrin, alpha-cypermethrin and deltamethrin (Pyrs) were selected according to their use as chemotherapeutants in the aquaculture industry. Different parameters affecting extraction efficiency such as fibre coating, agitation, pH and extraction time profiles were investigated. An experimental central composite design (alpha = 1) and desirability functions were used for the simultaneous optimization of extraction temperature and sample volume. Finally, a method based on direct SPME in 40 min at 75 degrees C using 100-microm-thick poly(dimethyl)siloxane (PDMS) fibre and 20 mL of sample volume is proposed. The method was validated, exhibiting good linearity, precision and accuracy parameters with picogram per millilitre LODs. The proposed methodology was applied to determine the ultratrace levels of OPPs and Pyrs in aquaculture-seawater samples by the standard addition approach, which proved to be reliable and sensitive, in addition to requiring only small amounts of sample.


Assuntos
Antiprotozoários/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Água do Mar/química , Microextração em Fase Sólida/métodos , Aquicultura , Clorpirifos/análise , Diclorvós/análise , Dimetilpolisiloxanos/química , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Concentração de Íons de Hidrogênio , Estrutura Molecular , Nitrilas/análise , Permetrina/análise , Piretrinas/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Microextração em Fase Sólida/instrumentação , Estereoisomerismo , Propriedades de Superfície , Temperatura , Fatores de Tempo , Poluentes Químicos da Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA