Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38747022

RESUMO

PURPOSE: The purpose of this study was to investigate if patient's gender significantly affected the long-term outcome of patients undergoing total knee arthroplasty (TKA) and to provide a cross-gender comparison of a large patient sample from a single regional register. METHODS: The Registry of Prosthetic Orthopedic Implant of Emilia Romagna (RIPO) investigated all primary TKAs performed from July 2000 to December 2020 by collecting data of men and women separately. Primary bicompartmental and tricompartmental TKAs were included. The survival rates and the reasons for revision were assessed to check if any other factor could have influenced implant failure. RESULTS: In total, 66,032 TKAs were included and analysed, comprising 46,774 women and 19,258 men. The 15-year Kaplan-Meier survival percentage was 93.6% for women and 92.5% for men (p = 0.001). Men exhibited a higher revision risk following primary TKA (p = 0.012), particularly when the primary diagnosis was arthritis resulting from rheumatic disorders (p = 0.018) and arthritis following high-tibial osteotomy (p = 0.024). Failure risk was also higher for men below the age of 60 years (p = 0.038). CONCLUSION: The long-term outcome in TKA showed significant differences between men and women, with a significantly lower survival rate in men at 15 years, especially when they are under 60 years old or with a diagnosis of rheumatic disorders or arthritis following high-tibial osteotomy. It is necessary to design specific studies to have relevant data concerning gender differences in prosthetic surgery and to customise treatments to improve outcome and patient satisfaction. LEVEL OF EVIDENCE: Level III.

2.
ACS Omega ; 9(11): 13081-13085, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38524423

RESUMO

Using a commercially available potentiostat, the electrochemical synthesis of unnatural amino acids bearing heteroaromatics on the lateral chain has been accomplished. This strategy exploits the side-chain decarboxylative arylation of aspartic/glutamic acid, a reaction that becomes challenging with electron-rich coupling partners such as 5- and 6-membered heteroaromatics. These rings are underrepresented in unnatural amino acids, therefore allowing a wider exploration of the chemical space, given the abundance of the aryl bromides employable in this reaction.

3.
J Clin Med ; 13(2)2024 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-38276110

RESUMO

Cementless primary stems in revision hip arthroplasties may be conservative options to preserve bone stock and provide adequate reconstruction of the hip biomechanics. However, there is still little evidence about indications, limitations, and outcomes. This narrative review showed that conventional standard stems were adopted in different revision settings, up to Paprosky IIIA grade bone defects. In cases of acceptable metaphyseal bone stock, when a scratch fit of at least 4 cm can be achieved, a conventional cementless stem may be an adequate solution. Mid-term clinical and radiographic outcomes and survival rates were similar to long revision stems, whereas complications, surgical time, and costs were lower among conventional stems. However, unsuitable contexts for conventional stems included canal diameters larger than 18 mm and failed revision stems with cortical weakening. Even short stems can be considered in revisions, in order to preserve bone stock and stay proximal to femoral remodeling zones and bone/cement plugs. Short stems were successfully adopted up to Paprosky IIIA bone defects, achieving mid-term survival rates not inferior to long revision stems. Ageing, osteoporosis, and intraoperative femoral fractures were the main negative prognostic factors. In very select cases, a downsizing technique (from longer to shorter stems) may be adopted to simplify the procedure and reduce complications.

4.
J Clin Med ; 12(23)2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38068401

RESUMO

BACKGROUND: There is a paucity of data regarding the post-operative influence of total hip arthroplasty (THA) on the axial and coronal alignments of the ipsilateral knee. A CT study was designed to assess the post-THA changes in axial and coronal knee alignments in low-grade dysplastic hips. METHODS: Forty Crowe I-II dysplastic hips in 37 patients were assessed: a pre-operative CT scan from the fourth lumbar vertebra to the tibial plateaus was compared to a similar post-operative CT scan performed after a minimum of 2 years after THA. RESULTS: THA implantation caused significant post-operative changes in terms of the rotation height (2 mm lowering; p = 0.003); center of rotation medialization (10 mm medialization; p < 0.001); femoral offset (11 mm increase; p < 0.001); femoral antetorsion (22° internal rotation; p < 0.001), and hip internal rotation (9° internal rotation; p < 0.001). The femoral axis angle deviated in the valgus (5.5° ± 1.1°, p < 0.001) and the mechanical lateral distal femoral angle deviated in the varus (86° ± 2.7°, p = 0.001). The pelvic-tibial alignment changed from 88.2° ± 11.7° to 96° ± 9.3° (p < 0.001). Patellar alignment was not influenced. CONCLUSIONS: In conclusion, THA imposes significant changes in low-grade dysplastic hips: all the modifications tend to neutralize the coronal alignment and, mostly, the rotational alignment, without substantial and durable variations of the patellofemoral joint. Large clinical trials should confirm whether radiological changes impact anterior knee pain and patellar stability.

5.
J Pers Med ; 13(12)2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38138931

RESUMO

Little is known about dynamic changes of femoral anatomy after total hip arthroplasty (THA), in particular about sagittal femoral bowing (SFB). A 3D CT study was designed to evaluate the chronological changes of SFB after cementless femoral stem implantation for primary THA. Ten patients who underwent unilateral primary THA with a cementless femoral stem, with 2 consecutive CT scans (extending from the fourth lumbar vertebra to the tibial plateaus), performed before THA and at least 3 years after THA, were enrolled. The 3D models of femurs were created using image segmentation software. Using the two CT scans, SFB values of the proximal and middle thirds were calculated on the replaced and untreated sides by two different observers. Eight anatomical stems and two conical stems were involved. The post-operative CT was performed at an average follow-up of 6.5 years after THA (range: 3-12.5). The measurements performed by the two observers did not differ in the proximal and middle regions. A significant difference between the pre-operative and post-operative SFB compared to the untreated side was found in the proximal femur segment (p = 0.004). Use of a cementless stem in THA induced chronological changes in SFB of the proximal femur, after a minimum timespan of 3 years.

6.
Med Princ Pract ; 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37729888

RESUMO

OBJECTIVE: The purpose of this systematic review is to assess clinical and radiographic outcomes, complications rates, rates and reasons of re-revision of isolated femoral or tibial component revisions, comparing them with total knee revisions. METHODS: A review of the published literature was performed using Medline, Embase and Cochrane libraries. The terms "isolate" and "revision" and "knee arthroplasty" or "knee replacement" were together used as MESH terms. Partial knee replacement, non-English literature, case reports and papers published before 2000 were excluded. RESULTS: Out of 911 papers, six papers met the inclusion criteria. Mean MINORS scores achieved quite low values (13.33 and 13.67). No study encompassed revisions for septic loosening or infection. Total revisions performed for instability and wear achieved better clinical outcomes: in the other cases, partial and total revisions showed no differences in clinical outcomes. Both the cohorts showed similar radiographic features. Lesser bleeding and shorter operative times were observed in partial revisions compared to total revisions. The re-revision rates were similar in most of comparative studies: only one study noticed a significant difference in the failure rate between partial (25% at 3 years) and full (7% at 3.5 years) revisions. CONCLUSIONS: The poor quality of the studies precluded sound conclusions. Isolated tibial or femoral component revision is an option when the other component is well-fixed and positioned and in absence of chronic periprosthetic infection; nevertheless, it should be carefully evaluated when the reasons for revision are wear or instability.

7.
Medicina (Kaunas) ; 59(7)2023 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-37512023

RESUMO

Background and Objectives: Post-COVID-19 syndrome is commonly used to describe signs and symptoms that continue or develop after acute COVID-19 for more than 12 weeks. The study aimed to evaluate a treatment strategy in patients with adhesive capsulitis (phase 1) developed in post-COVID-19 syndrome. Materials and Methods: The method used was an interventional pilot study in which 16 vaccinated patients presenting with the clinical and ultrasound features of adhesive capsulitis (phase 1) developed during post-COVID-19 syndrome were treated with infiltrative hydrodistension therapy under ultrasound guidance associated with early rehabilitation treatment. Results: Sixteen patients with post-COVID-19 syndrome treated with ultrasound-guided infiltration and early rehabilitation treatment showed an important improvement in active joint ROM after 10 weeks, especially in shoulder elevation and abduction movements. The VAS mean score before the treatment was 6.9 ± 1.66. After 10 weeks of treatment, the VAS score was 1 ± 0.63. Conclusions: The study demonstrated that the management of adhesive capsulitis (phase 1) developed in post-COVID-19 syndrome, as conducted by physiotherapists in a primary care setting using hydrodistension and a rehabilitation protocol, represented an effective treatment strategy.


Assuntos
Bursite , COVID-19 , Humanos , Síndrome de COVID-19 Pós-Aguda , Projetos Piloto , COVID-19/complicações , Bursite/complicações , Bursite/terapia , Bursite/diagnóstico , Resultado do Tratamento , Amplitude de Movimento Articular , Ultrassonografia de Intervenção
8.
J Clin Med ; 12(14)2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37510814

RESUMO

INTRODUCTION: A modular head-neck adapter system may help surgeons restore the proximal hip biomechanics in revision hip arthroplasty. However, the clinical and radiographic 5-year outcomes of the system are still scarcely reported. The aim of this study is the assessment of (1) complications and survival rates, (2) clinical and (3) radiological outcomes of the modular head-neck adapter system with a ceramic head in revision hip arthroplasty at 5 years. METHODS: 32 revision hip arthroplasties using a modular head-neck adapter system and a ceramic head were retrospectively recorded. Preoperative demographic and implant features were collected. Clinical and radiographic outcomes, failures and reasons for re-revisions were recorded at the last follow-up. RESULTS: A mean follow-up of 59.8 ± 26 months was achieved. The survival rate was 90.6% at 5 years. Post-operative complications occurred in nine cases (28.1%): two dislocations (6.2%), one aseptic cup loosening (3.1%) requiring re-revision, one (3.1%) persistent pelvic pseudotumor requiring embolization. No mechanical failures of the adapter or ceramic head occurred. The mean post-operative HHS score was 84.4 points. Thirteen cases (40.6%) showed optimal radiographic cup osseointegration, and 17 hips (53.1%) showed valid stem osseointegration. The mean post-operative femoral offset was 48.84 mm, larger than the contralateral side (p = 0.02). The post-operative lateralization of the hip joint was 38.09 mm, close to the contralateral side (p = 0.4). CONCLUSIONS: In revisions, the modular head-neck adapter system with ceramic head provided good clinical outcomes and acceptable radiographic reconstruction of hip biomechanics, with a survival rate of 87.9% at 5 years.

9.
Arch Orthop Trauma Surg ; 143(10): 6315-6321, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37261480

RESUMO

INTRODUCTION: The role of secondary patellar resurfacing (SPR) in anterior knee pain (AKP) is still debated in literature. A regional arthroplasty registry was investigated, aiming to: (1) assess the survival rate of SPR; and (2) compare SPR to tricompartmental TKA. MATERIALS AND METHODS: The regional arthroplasty registry RIPO was investigated about all SPRs performed after bicompartmental arthroplasty. The survival rates and the reasons for revision were assessed as any other factor that could have influenced implants failure. SPR survivorship was compared to tricompartmental TKAs. RESULTS: 406 SPRs performed after bicompartmental arthroplasty were analyzed. The survival rates were 80.6% (CI 95% 75.9-84.5) at 5 years and 77.6% (CI 95% 72.4-82) at 7 years. Half of the SPRs was performed 0.9-2.4 years after the index bicompartmental arthroplasty. SPR achieved lower survival than tricompartmental TKA (80.6% vs 96.7%, p < 0.001), with an adjusted hazard ratio for failure of 5.5 (CI 95% 4.2-7.1, p < 0.001). SPRs performed within 2 years after primary implant had a significantly higher rates of failure when compared to tricompartmental TKA (HR: 6.4, CI 95% 4.8-8.4, p < 0.001). CONCLUSION: SPR after bicompartmental knee arthroplasty showed modest 5- and 7-year survival rates, worse than primary tricompartmental TKA. When SPRs are performed within 2 years after primary arthroplasty, a significant higher risk of failure should be expected, highlighting than appropriate pre-operative work-up and patient selection is crucial for SPR successful outcome. LEVEL OF EVIDENCE: III, therapeutic study.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Resultado do Tratamento , Articulação do Joelho/cirurgia , Patela/cirurgia , Reoperação , Osteoartrite do Joelho/cirurgia
10.
J Clin Med ; 12(3)2023 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-36769632

RESUMO

The impact of age and sex on femoral component choices in modular total hip arthroplasty (THA) is still unknown. A regional arthroplasty registry was interrogated about a modular stem in THA performed for primary osteoarthritis, with the aims to assess the influence of age and sex on stems sizes and neck choices. A total of 6830 THAs were included: all THAs had a modular stem (with 15 necks and 27 combinations per side). Patients were stratified by age in decades and sex. Necks were grouped according to the type of correction. The percentage of larger stem sizes increased in males and in elder patients (p < 0.001). Standard necks were overrepresented in males aged 40-59 and underrepresented in males aged 70 or older (p < 0.001). Half of the necks provided other corrections than standard or offset, especially in males aged 40-49 and females aged 70 or older (p < 0.001). Offset necks were predominant in elder patients (p < 0.001). Version-correcting necks were prevalent in younger males and older females (p < 0.001). Varus necks were implanted in one-third of the cases. The four commonest necks showed age and sex specific patterns. In the registry, age and sex impacted stem size and neck choices in THA performed for primary osteoarthritis.

11.
Arch Orthop Trauma Surg ; 143(9): 5909-5918, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36764965

RESUMO

INTRODUCTION: The current strategy for modular neck failures in total hip arthroplasty (THA) is calibrated on CrCo neck failures. Stem revision is usually required, but the procedure is challenging and achieves modest outcomes (up to 20% of re-revisions at short-term). No study reports revision strategies and outcomes after Ti neck failures. Aims of the study were to evaluate: (1) demographic and implant features of the cohort to be revised, (2) intra-operative findings and surgical revision strategies and (3) clinical and radiological post-revision outcomes. MATERIALS AND METHODS: Hospital database was enquired about revisions due to Ti neck failures in primary THAs. Sixty-five revisions were enrolled (all with the same modular system). Neck exchange was attempted as the first-line treatment. Patients were clinically and radiographically evaluated after revision. RESULTS: The revision cohort encompassed fatigue neck fractures occurred 4.4 ± 2.6 years after THA: patients < 65 years and/or > 80 kg (98.5%) were predominant. Fifty-three neck exchanges were performed (81.5%). Eleven failures required stem revisions (16.9%), generally due to demanding neck extraction. Six complications occurred after neck exchange (11.3%), among them 2 acute infections requiring surgery (3.8%). Among stem revisions, one aseptic loosening and one neck re-fracture (18.5%) required re-revisions. At a mean follow-up of 7.1 ± 4 years, the neck exchange cohort achieved a mean HHS of 89.1 ± 6.3 (stem revisions: 84.1 ± 10.9). CONCLUSIONS: Revisions for Ti neck failures were predominantly performed due to fatigue fractures. In case of failures, neck exchange is a feasible procedure in most of the cases, with good outcomes at 7 years. LEVEL OF EVIDENCE: Level IV, retrospective case series.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Titânio , Estudos Retrospectivos , Desenho de Prótese , Reoperação , Falha de Prótese , Resultado do Tratamento , Seguimentos
12.
J Arthroplasty ; 38(8): 1578-1583, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36764407

RESUMO

BACKGROUND: Five- to 10-year outcomes of a modular head-neck adapter system with ceramic heads in revision hip arthroplasty on large populations are still lacking. A registry study about modular adapter system with Delta ceramic head in revisions was designed, aiming to assess (1) the survival rates of the device, (2) the reasons for re-revisions of the device, and (3) a comparison to factory assembled titanium sleeve and Delta head cohort in revision hips. METHODS: Using a regional arthroplasty registry, we investigated the modular adapter system with a ceramic head in revision hips. Demographics, implant features, and reasons for revision were recorded. Survival rates and reasons for re-revision were assessed. The modular adapter system with the ceramic ball was compared to a factory-assembled ceramic titanium-sleeved head in revisions, acting as a control group. There were 354 revisions included at a mean follow-up of 5 years (range, 0 to 13). RESULTS: The 5- and 7-year survival rates were 87.9% and 86.9%, respectively. Dislocations (2.8%) and cup aseptic loosening (4.2%) were the 2 most frequent reasons for re-revision. No breakage of the adapter system or the ceramic head occurred. A femoral neck failed (0.3%). No implant features, offset (P = .088) or skirted (P = .870) tapers, impacted on failures. No differences between the 2 cohorts were found regarding survival rates (P = .696) and reasons for re-revision (dislocations, P = .983; cup aseptic loosening, P = .296). CONCLUSION: The modular head neck adapter system with a ceramic head seems to be a valid option in revisions at 5 and 7 years, without additional risk of implant breakage in this registry.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Titânio , Falha de Prótese , Desenho de Prótese , Reoperação , Sistema de Registros , Cerâmica
13.
J Orthop Traumatol ; 24(1): 5, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36725766

RESUMO

BACKGROUND: In total hip arthroplasty (THA), the outcomes of single taper (ST) and dual taper (DT) versions of the same stem design have been scarcely studied. A registry study comparing ST and DT versions of the same stem design was designed, aiming to assess: (1) the survival rates and the hazard ratios for failure; (2) the survival rates and the hazard ratios for failure using stem-focused endpoints. MATERIAL AND METHODS: A regional arthroplasty registry was interrogated about stem designs with ST and DT versions in cementless THAs performed for primary osteoarthritis. Only the same cup and ceramic-on-ceramic bearings were included: the DT stems had a titanium-on-titanium modularity. Demographic and implant features were recorded. Survival rates and hazard ratios were evaluated and compared. Stem-focused endpoints were also investigated. RESULTS: A total of 5359 THAs were included, with three stem designs. The two versions of every stem showed different demographics and implant-related features: ST versions were preferentially implanted in heavier young men. For each stem, the two versions had similar survival rates at 5 years (p = 0.076; p = 0.319; p = 0.616) and similar adjusted hazard ratios for failures (p = 0.084; p = 0.308; p = 0.729). When stem-focused endpoints were adopted, the ST and DT versions of the three stems achieved similar survival rates (p = 0.710; p = 0.784; p = 0.983) and similar adjusted hazard ratios (p = 0.647; p = 0.858; p = 0.787). Three neck breakages occurred (0.0007% of all the modular implants). CONCLUSIONS: ST and DT versions of the same stem design did not show any differences in terms of survival rates and hazard ratios for failures at 5 years. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteoartrite , Masculino , Humanos , Titânio , Falha de Prótese , Desenho de Prótese , Reoperação
14.
Int Orthop ; 47(3): 641-645, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36637462

RESUMO

PURPOSE: Computer-assisted arthroplasty supports the surgeons in planning, simulating, and performing the replacement procedure, using robotic or navigation technologies. However, the safety of the technology has not been widely ascertained. Food and Drug Administration (FDA) database was interrogated about software-related recalls in computer-assisted arthroplasty, aiming to assess: (1) the incidence, (2) the root causes, and (3) the actions taken due to recalls. METHODS: The Medical Device Recalls database was investigated about software-related recalls in computer-assisted hip and knee arthroplasty surgery, between 2017 and 2022. The incidence of the software-related recalls, the root causes according to FDA and manufacturers, and the corrective actions taken by firms were determined. RESULTS: Eighteen recall numbers could be identified (1.6%), corresponding to 11 recall events. A total of 4634 units were involved. The FDA determined root causes were: software design (66.6%), design change (22.2%), manufacturing deployment (1, 5.6%), and design manufacturing process (5.6%). Among the manufacturers' reasons for recalls, a specific error was declared in 16 cases (88.9%). In seven cases (43.8%), a coding error about lower limb alignment assessment was identified. Seventeen software-related recalls (94.4%) were classified as class 2; only one case was class 3 (5.6%). Return of the device was the main action taken by firms (8, 44.4%), followed by software update (7, 38.9%). CONCLUSION: Software-related recalls in computer-assisted hip and knee arthroplasty were quite uncommon among all the recalls, deemed non-life threatening and usually due to software design errors. The main actions taken by manufacturers were the return of the device or the software update.


Assuntos
Artroplastia do Joelho , Robótica , Cirurgia Assistida por Computador , Humanos , Artroplastia do Joelho/efeitos adversos , Software , Recall de Dispositivo Médico , Computadores
15.
J Clin Med ; 12(2)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36675535

RESUMO

Cup overhanging in total hip arthroplasty is a predisposing factor to iliopsoas impingement. In dysplastic hips, cup implantation was simulated in an anatomic hip center of rotation (AHCR) and in high hip center (HHCR). We sought to assess: (1) the percentage of prominent cups; (2) quantify the cup protrusion at different sites on frontal, axial and sagittal views. In 40 Crowe III-IV hips, using a 3D CT-based planning software, cup planning in AHCR and HHCR (CR height ≥ 20 mm) was performed for every hip. Cup prominence was assessed on every plane. HHCR cups were less anteverted (p < 0.01), less medialized (p < 0.001) and less caudal (p = 0.01) than AHCR sockets. AHCR cups were more frequently prominent on at least one plane (92.5% vs. 77.5%), with minimal agreement between the two configurations (k = 0.31, p = 0.07). AHCR cups protruded more than HHCR sockets in the sagittal (p = 0.02) and axial planes (p < 0.001). Axially, at the center of the cup, prominence 6−11 mm occurred in nine (22.5%) AHCR and one (2.5%) HHCR socket. In conclusion, while a routine high hip center should not be recommended, cup placement at a center of rotation height < 20 mm is associated with higher rates and magnitudes of anterior cup protrusion in severe dysplasia.

16.
Orthop Traumatol Surg Res ; 109(7): 103503, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36496161

RESUMO

INTRODUCTION: Conical tapered stems may be useful implants to manage the reconstruction of complex dysplastic anatomies. The aims of this paper were to assess: 1) the preoperative CT features of the dysplastic femurs; 2) survival rates, complications and reasons for revision; 3) the clinical outcomes; 4) the radiographic outcomes of single-taper conical stems in dysplasia (defined as center edge angle < 20°) at a long-term follow-up. HYPOTHESIS: Monoblock conical stem provides a 10-year survival rate of at least 95%, with excellent clinical outcomes and bony ingrowth. MATERIALS AND METHODS: In total, 100 THAs in 85 patients (15 bilateral cases) were enrolled. The average age of the patients at surgery was 50.9±11.5 years. Assessment of the native femoral morphology was performed using CT-scan, coronal (neck-shaft angle, offset, center of rotation position) and axial parameters (anteversion, mediolateral and anteroposterior femoral diameters). Clinical (HHS score) and radiological (osseointegration, subsidence and offset reconstruction) outcomes were evaluated at the last available follow-up. RESULTS: The mean follow-up was 9.34±5.61 years. Severely distorted anatomies from Crowe I to Crowe IV were included, with a mean canal flare of 4.3 and a mean femoral antetorsion of 34°. The survival rates were stable at long-term (98.9% at 10 and 15 years): no aseptic loosening occurred. The mean postoperative HHS was 89.8±6.8 points. Ninety-nine percent of the stems showed bone ingrowth, from 6 months to the last available follow-up. Subsidence occurred in 18% of the cases (mean value: 2.5mm, range: 1-6mm) in the first month, with subsequent stabilization. A mild proximal stress shielding occurred in 28% of the THAs. Radiolucent lines were detected in the 8% of the cases. There was a postoperative loss of offset in 12% of the cases. DISCUSSION: Conical stems in dysplastic hips achieved bony ingrowth at long-term outcome, even in complex anatomies. Subsidence, proximal stress shielding and imperfect offset restoration may occur with this implant. LEVEL OF PROOF: IV; retrospective study.


Assuntos
Artroplastia de Quadril , Displasia do Desenvolvimento do Quadril , Prótese de Quadril , Humanos , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Displasia do Desenvolvimento do Quadril/cirurgia , Osseointegração , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Desenho de Prótese , Seguimentos , Resultado do Tratamento , Reoperação
17.
Hip Int ; 33(5): 916-924, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36127850

RESUMO

INTRODUCTION: The routine use of proximal femoral modularity was discouraged in total hip arthroplasties (THAs). However, titanium dual-taper (DT) implants may provide some advantages over single-taper (ST) stems in cases of complex deformity. A registry study comparing ST and DT stems in dysplasia was designed, aiming to assess: (1) survival rates at long-term; (2) reasons for revision; (3) the profile of failed implants. METHODS: The arthroplasty registry RIPO was investigated for cementless THAs performed for dysplasia since 2000. ST implants were compared to titanium-on-titanium DT stems. Demographics and implant features were collected. Survival rates and reasons for revision were compared. The profile of DT stem failures in dysplasia was defined. RESULTS: 6429 implants were included in the study, 3642 ST and 2787 DT. The demographic and implant features of the 2 cohorts were not comparable. The DT cohort achieved higher survival rates at long-term (93.9% vs. 91.6%, p = 0.018). DT implants showed a higher rate of implant breakage (0.6%, p = 0.011) and a lower rate of aseptic loosening (p = 0.005). There were no differences in terms of revisions for dislocation. No metallosis occurred. There were more revisions in DT implants in males <65 years, with a 28-mm head size or smaller. CONCLUSIONS: Modularity did not result in lower survival rates in dysplastic patients and may even reduce the rate of aseptic loosening in comparison to ST stems. The rate of implant breakage is not negligible. Younger males are not good candidates for titanium DT stems.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Masculino , Humanos , Artroplastia de Quadril/efeitos adversos , Titânio , Falha de Prótese , Desenho de Prótese , Reoperação , Sistema de Registros
18.
Ann Jt ; 8: 14, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38529239

RESUMO

Background: The correct management and treatment of pseudotumors due to metal-on-metal (MOM) hip arthroplasty are still debated. The purpose of this study is to analyze the surgical treatment and the clinical and radiographic 3-year outcomes of MOM arthroplasty revisions due to pseudotumor treated with a strategy of excision and revision. Methods: Consecutive, retrospective series of 21 patients (8 males/13 females) with pseudotumor due to MOM hip arthroplasty was surgically treated at a single tertiary center. Demographic, clinical, radiological and implant-related features were collected pre-operatively. Post-revision clinical and radiographic parameters were evaluated. Chromium (Cr) and cobalt (Co) blood samples were collected before and after surgery. Results: Three patients (14.2%) with pseudotumor underwent a resection arthroplasty due to infection (perioperative finding) and could not be reimplanted due to septic relapses. Twenty (95.2%) pseudotumors were completely resected. Revisions [2 total hip reimplantations (11.1%) and 16 isolated component revisions (88.9%)] were performed with non-MOM couplings. A clinical improvement at a mean post-revision follow-up 3.3 years [standard deviation (SD), ±2.2 years] was observed, from 50.3 (SD, ±4.6) to 88.3 (SD, ±9.2) Harris hip score (HHS) points (P<0.001). Among revisions, there were 5 complications (23.8%): 1 dislocation, 1 psoas impingement, and 3 infections (14.2%). No re-revision was carried out. Three (14.2%) pseudotumors recurred: 1 was surgically treated, 1 was treated with selective arterial embolization, and 1 clinically followed. At the final follow-up, Cr and Co blood ions beyond the threshold decreased from 85.7% cases to 0% in the seven patients that could be evaluated. Conclusions: The one-stage strategy of radical excision and revision with non-MOM couplings in pseudotumors due to MOM hip arthroplasty achieved good 3-year outcomes. However, complications were frequent (23%). Recurrences were not rare (14%) and did not require implant re-revision.

19.
World J Orthop ; 13(10): 903-910, 2022 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-36312522

RESUMO

BACKGROUND: Periprosthetic joint infection (PJI) in primary total hip replacement (THR) is one of the most important threats in orthopedic surgery, so one important surgeon's target is to avoid or early diagnose a PJI. Although the incidence of PJI is very low (0.69%) in our department, with an average follow-up of 595 d, this infection poses a serious threat due to the difficulties of treatment and the lower functional outcomes after healing. AIM: To study the incidence of PJI in all operations occurring in the year 2016 in our department to look for predictive signs of potential infection. METHODS: We counted 583 THR for 578 patients and observed only 4 cases of infection (0.69%) with a mean follow-up of 596 d (min 30, max 1451). We reviewed all medical records to collect the data: duration and time of the surgery, presence, type and duration of the antibiotic therapy, preoperative diagnosis, blood values before and after surgery, transfusions, presence of preoperative drugs (in particularly anticoagulants and antiaggregant, corticosteroids and immunosuppressants), presence of some comorbidities (high body mass index, blood hypertension, chronic obstructive pulmonary disease, cardiac ischemia, diabetes, rheumatological conditions, previous local infections). RESULTS: No preoperative, intraoperative, or postoperative analysis showed a higher incidence of PJI. We did not find any class with evident major odds of PJI. In our study, we did not find any border value to predict PJI and all patients had similar values in both groups (non-PJI and PJI). Only some categories, such as female patients, showed more frequency of PJI, but this difference related to sex was not statistically significant. CONCLUSION: We did not find any category with a higher risk of PJI in THR, probably due to the lack of few cases of infection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA