Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
J Orthop Traumatol ; 22(1): 2, 2021 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-33464425

RESUMO

The treatment of severe glenoid bone loss in shoulder arthroplasty represents a challenge, and the results of current prosthetic designs with only glenoid fixation still remain unsatisfactory. In the past decade, customized glenoid prostheses have been developed to address severe glenoid arthritis and in the revision setting. In this review, we analyzed the current surgical options, the classification limits, past literature evidence, and our preliminary results of 6 patients (3 male, 3 female) treated with a reverse implant and custom-made glenoid implant (ProMade; LimaCorporate, Italy). Computer analysis of the residual shape and the amount of glenoid bone stock in association with new classifications could help the surgeon to obtain good clinical and radiological outcomes. The development of navigation systems could improve the adequacy of the implant and, thus, the reliability and longevity of the implant itself.


Assuntos
Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Humanos , Radiografia , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Articulação do Ombro/diagnóstico por imagem
2.
J Orthop Traumatol ; 20(1): 27, 2019 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-31317280

RESUMO

The advancement of technologies in orthopaedic surgery should provide the surgeon with precise and trustworthy support for pre-operative planning, intra-operative guidance and post-operative follow-up. The request for greater accuracy, predictable results and fewer complications, is the engine of digital evolution in pre-operative planning and computer-assisted surgery (CAS). It is an evolution rather than a revolution, and in the last few years these developments have begun to involve shoulder replacement surgery, too.


Assuntos
Artroplastia do Ombro/métodos , Artropatias/cirurgia , Articulação do Ombro/cirurgia , Cirurgia Assistida por Computador/métodos , Humanos , Articulação do Ombro/diagnóstico por imagem
3.
Bone Joint J ; 101-B(4): 435-442, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30929494

RESUMO

AIMS: The purpose of this multicentre observational study was to investigate the association between intraoperative component positioning and soft-tissue balancing on short-term clinical outcomes in patients undergoing robotic-arm assisted unicompartmental knee arthroplasty (UKA). PATIENTS AND METHODS: Between 2013 and 2016, 363 patients (395 knees) underwent robotic-arm assisted UKAs at two centres. Pre- and postoperatively, patients were administered Knee Injury and Osteoarthritis Score (KOOS) and Forgotten Joint Score-12 (FJS-12). Results were stratified as "good" and "bad" if KOOS/FJS-12 were more than or equal to 80. Intraoperative, post-implantation robotic data relative to CT-based components placement were collected and classified. Postoperative complications were recorded. RESULTS: Following exclusions and losses to follow-up, 334 medial robotic-arm assisted UKAs were assessed at a mean follow-up of 30.0 months (8.0 to 54.9). None of the measured parameters were associated with overall KOOS outcome. Correlations were described between specific KOOS subscales and intraoperative, post-implantation robotic data, and between FJS-12 and femoral component sagittal alignment. Three UKAs were revised, resulting in 99.0% survival at two years (95% confidence interval (CI) 97.9 to 100.0). CONCLUSION: Although little correlation was found between intraoperative robotic data and overall clinical outcome, surgeons should consider information regarding 3D component placement and soft-tissue balancing to improve patient satisfaction. Reproducible and precise placement of components has been confirmed as essential for satisfactory clinical outcome. Cite this article: Bone Joint J 2019;101-B:435-442.


Assuntos
Artroplastia do Joelho/métodos , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Robótica/instrumentação , Idoso , Desenho de Equipamento , Feminino , Fêmur/diagnóstico por imagem , Seguimentos , Humanos , Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico , Satisfação do Paciente , Estudos Prospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
BMC Musculoskelet Disord ; 19(1): 364, 2018 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-30305070

RESUMO

BACKGROUND: Distal biceps tendon rupture occurs more often in middle-aged male population, involving the dominant arm. In this retrospective study, it's been described the occurrence of the most frequent adverse events and the clinical outcomes of patients undergoing surgical repair of distal biceps tendon rupture with the modified Morrey's double-incision approach, to determine better indications for patients with acute tendon injury. METHODS: Sixty-three patients with acute distal biceps tendon rupture treated with a modified double-incision technique between 2003 and 2015 were retrospectively evaluated at a mean 24 months of follow-up. Clinical evaluation including range of motion (ROM) and isometric strength recovery compared to the healthy contralateral side assessment, together with documentation of nerve injury, was performed. Patients were asked to answer DASH, OES and MEPS scores. RESULTS: The ROM recovery showed excellent results compared to the healthy contralateral side. The reported major complications included: one case of proximal radio-ulnar synostosis, 3 cases of posterior interosseous nerve (PIN) palsy and one case of a-traumatic tendon re-rupture. Concerning minor complications, intermittent pain, ROM deficiency < 30° in flexion/extension and pronation/supination, isometric flexion strength deficiency < 30% and isometric supination strength deficiency < 60%, lateral antebrachial cutaneous nerve (LACBN) injury, were observed. The average DASH score was 8.5; the average OES was 41.5 and the MEPS was 96.3. CONCLUSION: The Morrey modified double-incision technique finds its indication in young and active patients if performed within 2 weeks from injury. If performed by experienced surgeons, the advantages can exceed the drawbacks of possible complications.


Assuntos
Traumatismos do Braço/cirurgia , Articulação do Cotovelo/cirurgia , Procedimentos Ortopédicos/métodos , Reimplante , Traumatismos dos Tendões/cirurgia , Adulto , Idoso , Traumatismos do Braço/diagnóstico por imagem , Traumatismos do Braço/fisiopatologia , Fenômenos Biomecânicos , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Força Muscular , Procedimentos Ortopédicos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Reimplante/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos dos Tendões/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Lesões no Cotovelo
5.
Musculoskelet Surg ; 101(2): 189-193, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28236247

RESUMO

BACKGROUND: The humerus shaft is one of the sites with the largest probability of developing pseudoarthrosis after fracture. We present the results of nine patients with atrophic pseudoarthrosis of humeral shaft treated with angular stability plate associated with allograft and platelet-rich plasma (PRP), after a first treatment with intramedullary nail to correct the fracture. MATERIAL AND METHODS: From January 2012 to December 2014, nine patients were treated for atrophic pseudoarthrosis (PSA) of humeral shaft treated previously using intramedullary nail; seven humeral diaphysis fractures were located in the middle-proximal third and two in the middle third. In one case, a reverse shoulder prosthesis implant was associated to treat a co-existent rotator cuff massive lesion. The mean time between injury and treatment of non-union was 32 weeks (min 16-max 180); all patients were evaluated with Constant, DASH and UCLA score. RESULTS: At the final follow-up (23.7 months), the mean Dash score was 22.25 pt, the Constant score was 64 pt, and the UCLA score value was 27 pt. The average pain value was 2 for the arm interested and 0 into PSA focus. Radiographic healing was obtained at 7 months. CONCLUSIONS: The humeral shaft non-union is an invalidating problem which affects the daily living. Our treatment with plate, cortical bone graft, and PRP can build a high-stability structure that can help healing and graft integration.


Assuntos
Pinos Ortopédicos , Fixação Intramedular de Fraturas , Fraturas do Úmero/cirurgia , Pseudoartrose/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Orthop Traumatol Surg Res ; 103(2): 183-189, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27940249

RESUMO

BACKGROUND: Radial head fractures make up approximately 3% of all fractures and they are the most common elbow fracture in adults. Replacement through arthroplasty is the recommended treatment in the context of unstable elbow injury and comminuted radial head fracture. The midterm clinical, functional, and radiographic results in patients treated with anatomic radial head arthroplasty for a Mason type III radial head fracture are presented. MATERIAL AND METHODS: We performed a retrospective search of our facility's prospective trauma database to identify all skeletally mature patients who were treated by primary radial head replacement or open reduction and internal fixation following an acute radial head fracture. Inclusion criteria were Mason type III fractures and anatomic radial head arthroplasty (RHA). All the patients included were evaluated using a standard postoperative protocol including clinical and radiographic evaluation at 1, 3 and 12 months of follow-up. All the patients were reviewed clinically at an average of 30 months' follow-up. RESULTS: Forty-one subjects (32 Mason type III and 9 Mason IV fractures) were treated with anatomic RHA (Acumed, Hillsboro, OR, USA). Of these, two patients (1 Mason type III and 1 Mason type IV) were excluded from the analysis because severe cognitive impairment. Moreover, we decided to exclude the subjects with a Mason type IV fracture to obtain a more homogeneous sample. Therefore, 31 patients with a Mason type III fracture were included in this study. Based on the Mayo Elbow Performance Score, excellent results were obtained in 24 (77%) patients, good in 3 (10%) and fair in 4 (13%) patients. Heterotopic ossification was reported in 8 patients (26% of cases). The final elbow flexion-extension range of motion was of 112°, with a mean flexion of 125°. The final forearm rotational range of motion was 134° with a mean pronation of 68° and a mean supination of 66°. DISCUSSION: Anatomic radial head replacement leads to a good functional recovery, even in the presence of severe instability, such as coronoid fractures and LUCL injury. However, patients should be informed of the high number of adverse events (mainly heterotopic ossification) following this treatment. LEVEL OF EVIDENCE: Therapeutic IV.


Assuntos
Artroplastia de Substituição do Cotovelo/métodos , Articulação do Cotovelo/cirurgia , Fraturas Cominutivas/cirurgia , Fraturas do Rádio/cirurgia , Rádio (Anatomia)/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Substituição do Cotovelo/efeitos adversos , Articulação do Cotovelo/fisiopatologia , Epífises/cirurgia , Feminino , Antebraço/fisiopatologia , Fixação Interna de Fraturas , Humanos , Masculino , Pessoa de Meia-Idade , Redução Aberta , Ossificação Heterotópica/etiologia , Pronação , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Estudos Retrospectivos , Supinação , Resultado do Tratamento , Adulto Jovem
7.
Knee Surg Sports Traumatol Arthrosc ; 25(9): 2841-2848, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26704807

RESUMO

PURPOSE: In the present study, the precision of two patient-specific instrumentation (PSI) systems for total knee arthroplasty (TKA) was evaluated by comparing bony resection thicknesses of the pre-operative PSI planning and intra-operative measurements by a vernier calliper. It was hypothesized that the data provided by pre-operative planning were accurate within ±2 mm of the bone resection thickness measured intra-operatively. METHODS: Forty-one patient-specific TKAs were examined: 25 performed with Visionaire® technology and 16 with OtisMed® system. PSI accuracy was analysed comparing the resected bone thicknesses in the femoral and tibial cuts with pre-operatively planned resections. To determine pre-operative planning precision, the thickness values reported by the PSI planning were subtracted from the values reported intra-operatively by the calliper. RESULTS: The mean absolute differences between pre-operatively planned resections and corresponding intra-operative thickness measurements ranged from a minimum of 2.6 mm (SD 0.8) to a maximum of 3.6 mm (SD 1.3) in all three anatomical planes in both groups. In every plane, the mean absolute discrepancies between planned resections and measured cuts differed significantly from zero (p < 0.0001). The proportion of differences within ±2 mm between intra-operative measured resections and planned PSI cuts occurred in more than 90 % of the cohort for femoral distal resections. Less precision was reported for the femoral posterior medial cuts (70.7 % within ±2 mm) and the tibial cuts (70.7 % on the medial, 75.6 % on the lateral side). Prosthetic component alignment on the coronal and transverse planes resulted in considerable deviations from the pre-operative planning. CONCLUSION: The two examined PSI technologies were accurate in femoral distal cuts, determining acceptable femoral component placement on the coronal plane. Posterior femoral and tibial cuts were less precise. Deviations from the pre-operative resection planning were reported in every plane. Inaccuracy was explained by ambiguous custom-made jigs placement on the bony surface. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho/métodos , Artroplastia do Joelho/normas , Fêmur/anatomia & histologia , Fêmur/cirurgia , Prótese do Joelho , Tíbia/anatomia & histologia , Tíbia/cirurgia , Idoso , Feminino , Humanos , Masculino , Cirurgia Assistida por Computador/métodos
8.
Musculoskelet Surg ; 100(Suppl 1): 105-110, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27900709

RESUMO

BACKGROUND: Distal humeral malunions are uncommon injuries, often associated with limited elbow motion, pain, instability, weakness, and sometimes ulnar neuritis. The complex anatomy of the elbow joint makes this condition one of the most complex elbow injuries to treat. MATERIALS AND METHODS: Four patients were treated by the same surgeon between 2011 and 2013 using a double-locking precontoured plating system for malunited intra-articular or extra-articular fractures of the distal end of the humerus. RESULTS: At a mean 3 years of follow-up, a significant improvement in the elbow motion and functional outcome, evaluated with the Mayo Elbow Performance Index and the Disability of the Arm, Shoulder, and Hand, were observed. Articular reduction obtained after the surgery was maintained in all patients without evidence of avascular necrosis. No other complications (i.e., infection, nervous iatrogenic lesions) were reported. CONCLUSIONS: Corrective osteotomy using double-locking precontoured plating system preceded by preoperative planning using a CT scan allowed an improvement in the functional outcome and elbow motion, without complications.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fraturas Mal-Unidas/cirurgia , Fraturas do Úmero/cirurgia , Adulto , Feminino , Seguimentos , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Osteotomia/métodos , Estudos Prospectivos , Desenho de Prótese , Amplitude de Movimento Articular , Resultado do Tratamento
9.
Musculoskelet Surg ; 99(3): 217-23, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26514141

RESUMO

BACKGROUND: Coronal shear fractures of the distal humerus are uncommon injuries and are not exempt from complications. The aim of this research is to evaluate the possible advantages and drawbacks using cannulated compression headless screws. MATERIALS AND METHODS: We performed a prospective study including all the consecutive patients who were treated with cannulated screws for coronal shear fractures of the distal humerus between 2010 and 2013. Following the Dubberley's classification, three patients were type 1A, one patient was 1B, three patients were 2B, and one patient was 3B. The mean follow-up was 30 months. The clinical and radiological evaluation included analysis of passive range of motion, functional outcome, radiological evaluation of fracture healing and reduction maintenance, and the occurrence of possible adverse events. RESULTS: All fractures healed, and radiographic union was observed at an average of 3 months. The average elbow range of motion was 125°, with 125° of flexion and 20 of extension. According to the Broberg and Morrey score, there were four excellent and four good results. Using the Mayo Elbow Performance Index, five cases achieved excellent scores and three reported good results. Adverse events reported in three cases were as follows: heterotopic ossification, complex regional pain syndrome and delayed lateral collateral ligament disruption. CONCLUSIONS: The use of cannulated compression headless screws has given satisfactory results, allowing a strong inter-fragmentary compression, early mobilization, with high union rates and good elbow function. However, patients should be counseled about the high proportion of adverse events following these injuries.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas do Úmero/cirurgia , Amplitude de Movimento Articular , Adulto , Feminino , Seguimentos , Humanos , Fraturas do Úmero/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
10.
Musculoskelet Surg ; 99 Suppl 1: S1-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25962808

RESUMO

BACKGROUND: Locking plate fixation is a reliable treatment for many displaced proximal humeral fractures. Carbon fiber-reinforced-poly-ether-ether-ketone (CFR-PEEK) plates have recently been introduced as an alternative to traditional metallic plates. METHODS: In a multicenter study involving the Orthopedic Services of 6 Italian hospitals, 182 patients with a proximal humeral fracture were treated with a Diphos H (Lima Corporate, San Daniele del Friuli, Italy) CFR-PEEK plate, 160 of whom were followed clinically and radiographically for 2 years or more. Fractures were classified by Neer's system. The functional results were assessed by Constant and DASH scores. RESULTS: The average time to radiographic healing was 5.6 months in 158 of 160 cases. Mean Constant score was 76, and mean DASH score was 28 at 2 years. There were two nonunions (one septic and one aseptic) and 13 cases of partial (9) or massive (4) humeral head necrosis. In three of the 78 patients treated with the first-generation plates, hardware breakage happened during the operation and the plate was replaced. There was no failure among the cases treated with the thicker second-generation plate. In eight cases, there was a perforation of the humeral head by the cephalic screws. CONCLUSIONS: CFR-PEEK plates proved as reliable as metallic plates in the treatment of proximal humeral fractures. The advantages of these new devices include a better visualization of fracture reduction during intraoperative fluoroscopic assessment and easy hardware removal due to the absence of screw-plate cold fusion.


Assuntos
Placas Ósseas , Carbono , Fixação Interna de Fraturas/métodos , Fraturas do Ombro/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibra de Carbono , Feminino , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Radiografia , Fraturas do Ombro/diagnóstico por imagem , Fatores de Tempo , Adulto Jovem
11.
Musculoskelet Surg ; 99 Suppl 1: S9-15, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25957545

RESUMO

BACKGROUND: The risk of post-traumatic humeral head avascular necrosis (AVN), regardless of the treatment, has a high reported incidence. In 2004, Hertel et al. stated that the most relevant predictors of ischemia after intracapsular fracture treated with osteosynthesis are the calcar length, medial hinge integrity and some specific fracture types. Based on Hertel's model, the purpose of this study is to evaluate both its reliability and weaknesses in our series of 267 fractures, assessing how the anatomical configuration of fracture, the quality of reduction and its maintenance were predictive of osteonecrosis development, and so to suggest a treatment choice algorithm. MATERIALS AND METHODS: A retrospective study, level of evidence IV, was conducted to duly assess the radiographic features of 267 fractures treated from 2004 to 2010 following Hertel's criteria treated with open reduction and internal fixation by angular stability plates and screws. The average age was 65.2 years. The average follow-up was 28.3 ± 17.0 months. The percentage of AVN, the quality and maintenance of reduction obtained during surgery were evaluated. RESULTS: The AVN incidence was 3.7 %. No significant correlation with gender, age and fracture type was found. At the last follow-up X-ray, only 30 % presented all Hertel's good predictors in the AVN group, 4.7 % in the non-AVN group (p < 0.05). About quality of reduction in the AVN group, it was poor in 50 %; while in the non-AVN group, it was poor in 3.4 % (p < 0.05). Four patients with AVN were symptomatic, and three needed a second surgery. CONCLUSIONS: Hertel's criteria are important in the surgical planning, but they are not sufficient: an accurate evaluation of the calcar area fracture in three planes is required. All fractures involving calcar area should be studied with CT.


Assuntos
Fixação Interna de Fraturas/métodos , Osteonecrose/etiologia , Complicações Pós-Operatórias/etiologia , Fraturas do Ombro/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Úmero/irrigação sanguínea , Incidência , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Osteonecrose/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Radiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fraturas do Ombro/diagnóstico por imagem
12.
Thyroid ; 25(5): 538-50, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25747526

RESUMO

BACKGROUND: Thyroid nodules are a common finding in the general population, and their detection is increasing with the widespread use of ultrasound (US). Thyroid cancer is found in 5-15% of cases depending on sex, age, and exposure to other risk factors. Some US parameters have been associated with increased risk of malignancy. However, no characteristic seems sufficiently reliable in isolation to diagnose malignancy. The objective of this meta-analysis was to evaluate the diagnostic performance of US features for thyroid malignancy in patients with unselected thyroid nodules and nodules with indeterminate fine-needle aspiration (FNA) cytology. METHODS: Electronic databases were reviewed for studies published prior to July 2012 that evaluated US features of thyroid nodules and reported postoperative histopathologic diagnosis. A manual search of references of review and key articles, and previous meta-analyses was also performed. A separate meta-analysis was performed including only nodules with indeterminate cytology. Analyzed features were solid structure, hypoechogenicity, irregular margins, absence of halo, microcalcifications, central vascularization, solitary nodule, heterogeneity, taller than wide shape, and absence of elasticity. RESULTS: Fifty-two observational studies (12,786 nodules) were included. Nine studies included nodules with indeterminate cytology as a separate category, comprising 1851 nodules. In unselected nodules, all US features were significantly associated with malignancy with an odds ratio varying from 1.78 to 35.7, and microcalcifications, irregular margins, and a taller than wide shape had high specificities (Sp; 87.8%, 83.1%, 96.6%) and positive likelihood ratios (LHR; 3.26, 2.99, 8.07). Absence of elasticity was the single feature with the best diagnostic performance (sensitivity 87.9%, Sp 86.2%, and positive LHR 6.39). The presence of central vascularization was the most specific US feature in nodules with indeterminate cytology (Sp 96% and positive LHR 2.13). CONCLUSIONS: US features in isolation do not provide reliable information to select nodules that should have a FNA performed. A combination of US characteristics with higher likelihood ratios and consequently with higher post-test probabilities of malignancy-microcalcifications, or a taller than wide shape, or irregular margins, or absence of elasticity-will probably identify nodules with an increased risk for malignancy. Further studies are required to standardize elastography techniques and evaluate outcomes, especially in nodules with an indeterminate cytology.


Assuntos
Carcinoma/diagnóstico por imagem , Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Diagnóstico Diferencial , Humanos , Risco , Ultrassonografia
13.
Knee Surg Sports Traumatol Arthrosc ; 23(7): 2074-80, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24682516

RESUMO

PURPOSE: Concerns exist regarding prosthetic positioning and post-operative limb alignment in unicompartmental knee arthroplasty (UKA). In this study, we hypothesized deviations of the post-op anatomical femoro-tibial angle (aFTA) and the tibial component alignment to be factors influencing UKA survivorship. Moreover, by a comparison between all-poly and metal back UKAs, we hypothesized that prosthetic design plays a role in implant survivorship. METHODS: One hundred ninety-five medial UKAs were performed on 176 patients by two experienced surgeons and one low-UKA user. One hundred and forty-seven UKAs were included in the study: 72 all-poly and 75 metal back. Measurements were performed on radiographs: mechanical femoro-tibial angle, Cartier angle, aFTA and tibial posterior slope (PS) on pre-op radiographs; femoral and tibial component varus/valgus, aFTA and tibial component PS on post-op radiographs. RESULTS: At an average follow-up of 61 months (min. 30, max. 107), 147 UKAs were evaluated: The reported survivorship rate was 93.1 %. Eleven implants underwent revision: ten all-poly and one metal back. No differences were reported between the two groups in the radiographic measurements. Significant radiographic differences were reported between revised and not revised UKAs: Revised UKAs were associated with overcorrection of the pre-op Cartier angle and under correction of pre-op aFTA. Most of revised UKAs were performed by the low-volume UKA surgeon. CONCLUSIONS: Surgeon's experience is essential to achieve good results in UKA: Preserving the tibial epiphyseal axis and avoiding excessive or insufficient corrections of the pre-operative limb alignment are predictor of successful replacement, while prosthetic designs, models and fixation geometry do not affect UKA outcome. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia do Joelho/instrumentação , Competência Clínica , Prótese do Joelho , Desenho de Prótese , Idoso , Artroplastia do Joelho/métodos , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Masculino , Metais , Polietilenos , Radiografia , Reoperação , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
14.
Knee Surg Sports Traumatol Arthrosc ; 22(8): 1805-11, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24817110

RESUMO

PURPOSE: Although several anatomical landmarks have been proposed to obtain adequate femoral component alignment in total knee arthroplasty (TKA), there is still no consensus regarding the best way to correctly position the prosthetic component on the horizontal plane. A previous computed tomography (CT)-based study has demonstrated anatomical transepicondylar axis (aTEA) to be externally rotated relative to surgical transepicondylar axis (sTEA) of approximately 4.5°. In this study, it is described a new methodological approach to femoral component rotational positioning through the use of previously reported CT scan information and navigation. METHODS: Eight consecutive patients scheduled for navigated TKA were selected. Rotational placement of the femoral component was performed using navigation system. The femoral component was implanted setting 4.5° of internal rotation relative to the aTEA. Within 1 week from surgery, all patients underwent a CT scan, and the posterior condylar angle (PCA) was measured. A PCA of 0.0°, meaning component placement parallel to sTEA, was set as femoral rotational alignment target. Clinical evaluation was performed at a mean 14.3 months of follow-up with KOOS questionnaire. RESULTS: The mean PCA measured on post-operative CT images was 0.4° (SD 1.3°), meaning that the femoral component was averagely implanted with 0.4° of internal rotation relative to the sTEA. Seven out of eight cases (87.5 %) resulted to have within 1° deviation from the rotational alignment target. All patients but one reported good clinical results. CONCLUSIONS: Relevant finding of the present study was that the use of navigation and aTEA as a reference demonstrated to be accurate to set up femoral component rotational positioning on the horizontal plane in TKA. Further study should be performed to confirm this conclusion.


Assuntos
Artroplastia do Joelho , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/diagnóstico por imagem , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Rotação , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X
15.
Musculoskelet Surg ; 98 Suppl 1: 19-25, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24659199

RESUMO

PURPOSE: To compare functional and radiographic results of reverse prosthesis versus hemiarthroplasty after complex displaced proximal humeral fractures in elderly patients when adequate ORIF cannot be achieved and prosthetic shoulder replacement is required. METHODS: From 2008 to 2012, 67 patients were treated with hemiarthroplasty or reverse arthroplasty. We evaluated 53 cases with an average follow-up of 27.5 months (range 12-64). Twenty-eight patients with an average age of 71.4 years were treated with a hemiarthroplasty and 25 patients with an average age of 77.3 years with a reverse prosthesis. All patients were assessed before and after surgery by Constant-ASES-DASH score, strength in abduction, ER1, ER2, and X-rays. RESULTS: In hemiarthroplasty group, we observed a mean Constant score of 42.3 pt, ASES score 51.3 pt, and DASH score 46.1, with an average strength of 1.3 lb in abduction and of 3.7 lb in ER1 and 1.8 lb in ER2. In reverse arthroplasty group, we measured a mean Constant of 56.2 pt, ASES 69.3 pt, and DASH score 40.4, with an average strength of 4.3 lb in abduction and of 3.3 lb in ER1 and 3.2 lb in ER2. Radiographically, it is interesting to observe that greater tuberosity healing rate was 37 % in hemiarthroplasty group compared to 84 % in reverse arthroplasty group. About complications, the highest rate was recorded in the hemiarthroplasty group. CONCLUSION: Reverse shoulder arthroplasty indication is steadily increasing in acute displaced proximal humeral fracture. Pain and articular movement results appear better than those with hemiarthroplasty. Our data are similar to the international literature.


Assuntos
Artroplastia de Substituição , Radiografia , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Idoso , Artroplastia de Substituição/métodos , Seguimentos , Hemiartroplastia/métodos , Humanos , Radiografia/métodos , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
16.
Clin Biomech (Bristol, Avon) ; 29(4): 429-33, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24530155

RESUMO

BACKGROUND: The transosseous approach has been well known for a long time as a valid repair approach. Over time, various criticisms have been raised over this technique principally classifiable in two main categories: technical difficulty and related reproducibility in an arthroscopic environment, and repair stability (in the suture-bone contact area). About cyclic performance, several authors have conceived test setups with the aim of simulating a real environment in dynamic load conditions. The aim of this study was to monitor gap formation in a cyclic test setup. METHODS: The performance (measured as gap formation) has been monitored as a function of bone density to verify the effect of the latter. The test blocks have been shaped using sawbones® test bricks (Malmo, Sweden) of different densities, and the following values have been tested: 10, 15, 20, 30 and 40pcf. FINDINGS: The comparison has been made between the two groups: traditional transosseous and new approach with an interposed device. Regarding the traditional transosseous approach in a 10-pcf environment, not even the first loading cycle was completed, the whole bone bridge was destroyed in the first loading ramp and no further loading capability was present in the repair. By increasing the block density, the surface damage in the suture-block contact decreased. INTERPRETATION: With this work, it has been demonstrated how the traditional transosseous approach is strongly influenced by the bone quality up to the point where, in certain conditions, a safe and reliable repair is not guaranteed.


Assuntos
Densidade Óssea , Manguito Rotador/cirurgia , Técnicas de Sutura , Artroscopia/métodos , Fenômenos Biomecânicos , Modelos Biológicos , Reprodutibilidade dos Testes , Manguito Rotador/fisiopatologia , Suporte de Carga/fisiologia
17.
Musculoskelet Surg ; 97 Suppl 1: 57-61, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23588826

RESUMO

PURPOSE: Today, in rotator cuff tear repair, the transosseous sutures are considered superior from a biological and biomechanical point of view. Our purpose is to present the early clinical and biomechanical data of a new arthroscopic rotator cuff tear transosseous repair system: the Sharc-FT®. MATERIALS AND METHODS: A total of 34 patients with rotator cuff tear affecting supraspinatus and infraspinatus, 1 to 3 cm wide, were treated and evaluated from 2010 to 2013. The average age was 63.2 years. Mean follow-up was 18.6 months. All patients were assessed through Constant score in the preoperative step and at 3-, 6-, and 12-month follow-up, performing an MRI 6 months after surgery. RESULTS: The patients have shown a mean preoperative Constant score of 24.5 pt that constantly increases after surgery, until a mean value of 86.9 at 12 months. Regarding complications two cases of adhesive capsulitis were recorded. CONCLUSIONS: This device permits to obtain transosseous sutures with cortical fixation; to greatly reduce the problems of lack of bone resistance; to decrease motion at tendon-footprint interface improving fatigue resistance; to make the stress-load distribution homogeneous at the footprint, thus optimizing biological healing. A later evaluation will be necessary, especially for the incidence of retears.


Assuntos
Artroscópios , Lesões do Manguito Rotador , Manguito Rotador/cirurgia , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ruptura
18.
Injury ; 44 Suppl 1: S16-20, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23351864

RESUMO

INTRODUCTION: There are several surgical options to restore a wide osteochondral defect in the knee. Fresh osteochondral allografts are usually considered a poor alternative due to their difficulties in surgical application. The aim of this work is first to present our experience including the surgical technique and the functional results of patients receiving fresh osteochondral allograft to restore major knee lesions, then, to compare our results with other results presented in literature. METHODS: Between 2006 and 2011, we treated 11 patients with osteochondral lesion of the knee (Outerbridge IV°). The average lesion size was 10.3 cm(2) (range 3-20 cm(2)). The average age was 34 years (range 18-66). Patients were followed from 12 to 55 months (average of 26.5) through clinical examination, X-ray film and MRI every 3 months for the first year, then every 6 months. RESULTS: The treatment was successful in 10 patients showing pain regression and mean IKDC subjective score improvements from 27.3 to 58.7. The IKDC objective score also improved of at least one class for each patient except the who failed. The radiographs show good osteointegration in all cases but one. CONCLUSIONS: Fresh allograft is an effective therapy for osteochondral defects repair because it allows functional recovery in a considerable number of patients. This technique obtains better results in lesion smaller than 8 cm(2). However larger lesion show good results. LEVEL OF EVIDENCE: Therapeutic study, Level IV.


Assuntos
Transplante Ósseo/métodos , Cartilagem Articular/patologia , Cartilagem Articular/cirurgia , Traumatismos do Joelho/cirurgia , Articulação do Joelho/cirurgia , Adulto , Idoso , Cartilagem Articular/lesões , Feminino , Sobrevivência de Enxerto , Humanos , Artropatias/cirurgia , Traumatismos do Joelho/patologia , Traumatismos do Joelho/fisiopatologia , Articulação do Joelho/patologia , Articulação do Joelho/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Medição da Dor , Índice de Gravidade de Doença , Transplante Homólogo , Índices de Gravidade do Trauma , Resultado do Tratamento
20.
Knee Surg Sports Traumatol Arthrosc ; 21(10): 2331-7, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23184086

RESUMO

PURPOSE: There is a lot of inter-individual variation in the rotational anatomy of the distal femur. This study was set up to define the rotational anatomy of the distal femur in the osteo-arthritic knee and to investigate its relationship with the overall coronal alignment and gender. METHODS: CT-scans of 231 patients with end-stage knee osteo-arthritis prior to TKA surgery were obtained. This represents the biggest series published on rational geometry of the distal femur in literature so far. RESULTS: The posterior condylar line (PCL) was on average 1.6° (SD 1.9) internally rotated relative to the surgical transepicondylar axis (sTEA). The perpendicular to trochlear anteroposterior axis (⊥TRAx) was on average 4.8° (SD 3.3°) externally rotated relative to the sTEA. The relationship between the PCL and the sTEA was statistically different in the different coronal alignment groups (p < 0.001): 1.0° (SD 1.8°) in varus knees, 2.1° (SD 1.8°) in neutral knees and 2.6° (SD 1.8°) in valgus knees. The same was true for the ⊥TRAx in these 3 groups (p < 0.02).There was a clear linear relationship between the overall coronal alignment and the rotational geometry of the distal femur. For every 1° in coronal alignment increment from varus to valgus, there is a 0.1° increment in posterior condylar angle (PCL vs sTEA). CONCLUSION: The PCL was on average 1.6° internally rotated relative to the sTEA in the osteo-arthritic knee. The relationship between the PCL and the sTEA was statistically different in the different coronal alignment groups. LEVEL OF EVIDENCE: III.


Assuntos
Anteversão Óssea/patologia , Retroversão Óssea/patologia , Fêmur/patologia , Articulação do Joelho/patologia , Osteoartrite do Joelho/patologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho , Anteversão Óssea/complicações , Anteversão Óssea/diagnóstico por imagem , Anteversão Óssea/cirurgia , Retroversão Óssea/complicações , Retroversão Óssea/diagnóstico por imagem , Retroversão Óssea/cirurgia , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos , Rotação , Fatores Sexuais , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA