Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Bioanalysis ; 11(12): 1129-1138, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31319683

RESUMO

The 12th GCC Closed Forum was held in Philadelphia, PA, USA, on 9 April 2018. Representatives from international bioanalytical Contract Research Organizations were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at the meeting included: critical reagents; oligonucleotides; certificates of analysis; method transfer; high resolution mass spectrometry; flow cytometry; recent regulatory findings and case studies involving stability and nonclinical immunogenicity. Conclusions and consensus from discussions of these topics are included in this article.


Assuntos
Certificação , Técnicas de Química Analítica , Citometria de Fluxo , Espectrometria de Massas , Oligonucleotídeos/análise , Controle Social Formal , Sociedades Científicas , Indicadores e Reagentes/química
2.
Bioanalysis ; 10(7): 433-444, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29701066

RESUMO

The 11th Global CRO Council Closed Forum was held in Universal City, CA, USA on 3 April 2017. Representatives from international CRO members offering bioanalytical services were in attendance in order to discuss scientific and regulatory issues specific to bioanalysis. The second CRO-Pharma Scientific Interchange Meeting was held on 7 April 2017, which included Pharma representatives' sharing perspectives on the topics discussed earlier in the week with the CRO members. The issues discussed at the meetings included cumulative stability evaluations, matrix stability evaluations, the 2016 US FDA Immunogenicity Guidance and recent and unexpected FDA Form 483s on immunogenicity assays, the bioanalytical laboratory's role in writing PK sample collection instructions, biosimilars, CRO perspectives on the use of chiral versus achiral methods, hybrid LBA/LCMS assays, applications of fit-for-purpose validation and, at the Global CRO Council Closed Forum only, the status and trend of current regulated bioanalytical practice in China under CFDA's new BMV policy. Conclusions from discussions of these topics at both meetings are included in this report.


Assuntos
Bioensaio/métodos , Biomarcadores/análise , Medicamentos Biossimilares/uso terapêutico , China , Humanos , Projetos de Pesquisa
3.
Bioanalysis ; 9(7): 505-516, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28339299

RESUMO

The 10th Global CRO Council (GCC) Closed Forum was held in Orlando, FL, USA on 18 April 2016. In attendance were decision makers from international CRO member companies offering bioanalytical services. The objective of this meeting was for GCC members to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues discussed at this closed forum included reporting data from failed method validation runs, GCP for clinical sample bioanalysis, extracted sample stability, biomarker assay validation, processed batch acceptance criteria, electronic laboratory notebooks and data integrity, Health Canada's Notice regarding replicates in matrix stability evaluations, critical reagents and regulatory approaches to counteract fraud. In order to obtain the pharma perspectives on some of these topics, the first joint CRO-Pharma Scientific Interchange Meeting was held on 12 November 2016, in Denver, Colorado, USA. The five topics discussed at this Interchange meeting were reporting data from failed method validation runs, GCP for clinical sample bioanalysis, extracted sample stability, processed batch acceptance criteria and electronic laboratory notebooks and data integrity. The conclusions from the discussions of these topics at both meetings are included in this report.


Assuntos
Biomarcadores/análise , Técnicas de Química Analítica/normas , Coleta de Dados/normas , Guias como Assunto , Preparações Farmacêuticas/análise , Estabilidade de Medicamentos , Regulamentação Governamental , Humanos , Relatório de Pesquisa
4.
Bioanalysis ; 8(6): 487-95, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26916197

RESUMO

The 9th GCCClosed Forum was held just prior to the 2015 Workshop on Recent Issues in Bioanalysis (WRIB) in Miami, FL, USA on 13 April 2015. In attendance were 58 senior-level participants, from eight countries, representing 38 CRO companies offering bioanalytical services. The objective of this meeting was for CRO bioanalytical representatives to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues selected at this year's closed forum include CAPA, biosimilars, preclinical method validation, endogenous biomarkers, whole blood stability, and ELNs. A summary of the industry's best practices and the conclusions from the discussion of these topics is included in this meeting report.


Assuntos
Biomarcadores/análise , Medicamentos Biossimilares/análise , Avaliação Pré-Clínica de Medicamentos/métodos , Biomarcadores/sangue , Registros Eletrônicos de Saúde , Laboratórios , Sociedades Médicas , Estudos de Validação como Assunto
5.
Bioanalysis ; 6(22): 2957-63, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25496252

RESUMO

The 8th GCC Closed Forum for Bioanalysis was held in Baltimore, MD, USA on 5 December 2013, immediately following the 2013 AAPS Workshop (Crystal City V): Quantitative Bioanalytical Methods Validation and Implementation--The 2013 Revised FDA Guidance. This GCC meeting was organized to discuss the contents of the draft revised FDA Guidance on bioanalytical method validation that was published in September 2013 and consolidate the feedback of the GCC members. In attendance were 63 senior-level participants, from seven countries, representing 46 bioanalytical CRO companies/sites. This event represented a unique opportunity for CRO bioanalytical experts to share their opinions and concerns regarding the draft FDA Guidance, and to build unified comments to be provided to the FDA.


Assuntos
Técnicas de Química Analítica/normas , Guias como Assunto , Estudos de Validação como Assunto , Biomarcadores/análise , Calibragem , Ligantes , Limite de Detecção , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Estados Unidos , United States Food and Drug Administration
6.
Bioanalysis ; 6(18): 2385-90, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25384591

RESUMO

The topic of incurred sample stability (ISS) has generated considerable discussion within the bioanalytical community in recent years. The subject was an integral part of the seventh annual Workshop on Recent Issues in Bioanalysis (WRIB) held in Long Beach, CA, USA, in April 2013, and at the Global CRO Council for Bioanalysis (GCC) meeting preceding it. Discussion at both events focused on the use of incurred samples for ISS purposes in light of results from a recent GCC survey completed by member companies. This paper reports the consensus resulting from these discussions and serves as a useful reference for depicting ISS issues and concerns, summarizing the GCC survey results and providing helpful recommendations on ISS in the context of bioanalytical method development and application.


Assuntos
Testes de Química Clínica , Coleta de Dados , Reprodutibilidade dos Testes
8.
Bioanalysis ; 4(17): 2117-26, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23013394

RESUMO

An open letter written by the Global CRO Council for Bioanalysis (GCC) describing the GCC survey results on stability data from co-administered and co-formulated drugs was sent to multiple regulatory authorities on 14 December 2011. This letter and further discussions at different GCC meetings led to subsequent recommendations on this topic of widespread interest within the bioanalytical community over the past 2 years.


Assuntos
Combinação de Medicamentos , Preparações Farmacêuticas/análise , Tecnologia Farmacêutica/normas , Biomarcadores/análise , Cromatografia Líquida de Alta Pressão/métodos , Estabilidade de Medicamentos , Regulamentação Governamental , Guias como Assunto , Humanos , Espectrometria de Massas em Tandem/métodos
10.
Bioanalysis ; 3(24): 2721-7, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22185271

RESUMO

The 3rd Global CRO Council Closed Forum was held on the 3rd and 4th July 2011 in Guildford, United Kingdom, in conjunction with the 19th International Reid Bioanalytical Forum. In attendance were 21 senior-level representatives from 19 CROs on behalf of nine European countries and, for many of the attendees, this occasion was the first time that they had participated in a GCC meeting. Therefore, this closed forum was an opportunity to increase awareness of the aim of the GCC and how it works, share information about bioanalytical regulations and audit findings from different agencies, their policies and procedures and also to discuss some topics of interest and aim to develop ideas and provide recommendations for bioanalytical practices at future GCC meetings in Europe.


Assuntos
Preparações Farmacêuticas/análise , Tecnologia Farmacêutica/organização & administração , Biomarcadores/análise , Cromatografia Líquida de Alta Pressão , Regulamentação Governamental , Hemólise , Humanos , Espectrometria de Massas em Tandem
12.
Arzneimittelforschung ; 55(4): 191-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15901041

RESUMO

An open-label, randomised, crossover single dose study, using 2 periods x 2 sequences, with a minimum washout period of 4 weeks, was conducted in order to assess the comparative bioavailability of two formulations of sertraline hydrochloride (CAS 79617-96-2) 100 mg tablets. Plasma samples were obtained at intake (baseline) and at +1 h, +2 h, +3 h, +4 h, +5 h, +6 h, +7 h, +8 h, +9 h, +12 h, +24 h, +48 h, +72 h and +96 h post administration. Sertraline plasma concentrations were determined by high pressure liquid chromatography with tandem mass detection (HPLC-MS/MS) and the lower limit of quantification was set at 100.15 pg/mL. Pharmacokinetic parameters used for bioequivalence assessment (AUClast, AUCinf and Cmax) were determined by non-compartmental analysis. Classical 90 % confidence intervals (90CI) were calculated for the overall sample, and for males and females separately, and gender effects were investigated using an appropriate model. The results showed that overall classical 90CI were 84.55-100.32 % for Cmax 86.96-98.68 % for AUClast, and 86.79-98.93 for AUCinf, that is, they were all within the predefined ranges for bioequivalence acceptance. Separate gender analysis showed very similar results for males and females when analysed independently, and no gender effects were detected in bioequivalence analysis (p > 0.05). It may be therefore concluded that the evaluated formulations are bioequivalent in terms of rate and extent of absorption.


Assuntos
Inibidores Seletivos de Recaptação de Serotonina/administração & dosagem , Inibidores Seletivos de Recaptação de Serotonina/farmacocinética , Sertralina/administração & dosagem , Sertralina/farmacocinética , Adolescente , Adulto , Área Sob a Curva , Disponibilidade Biológica , Calibragem , Química Farmacêutica , Estudos Cross-Over , Método Duplo-Cego , Feminino , Meia-Vida , Humanos , Masculino , Análise de Regressão , Inibidores Seletivos de Recaptação de Serotonina/efeitos adversos , Sertralina/efeitos adversos , Caracteres Sexuais , Equivalência Terapêutica
13.
Curr Ther Res Clin Exp ; 64(7): 401-11, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24944391

RESUMO

BACKGROUND: Paracetamol is often the analgesic or antipyretic of choice, especially for patients for whom salicylates or other nonsteroidal anti-inflammatory drugs are contraindicated. OBJECTIVE: The aim of this study was to compare the absorption rate of a new tablet formulation of paracetamol (500 mg) with a reference formulation of paracetamol at the same dose. METHODS: This was a single-center, Phase I, open-label, randomized, 2-period, crossover, single-dose, comparative bioavailability clinical trial. During both study periods, healthy volunteers were given a single oral dose of a more hydrophilic test formulation of paracetamol, or a reference formulation. Fifteen plasma samples were obtained to determine paracetamol concentrations and to calculate kinetic parameters. RESULTS: The study participants comprised 24 healthy volunteers (12 men, 12 women; mean [SD] age, 22.8 [1.5] years). The pharmacokinetic parameters calculated for the test versus the reference formulation were as follows: median time to maximum concentration (Tmax), 0.42 versus 0.75 hour; mean (SD) maximum plasma drug concentration (Cmax), 9.85 (2.40) µg/mL versus 8.33 (2.22) µg/mL; and mean (SD) area under the plasma concentration-time curve from time 0 to infinity (AUC0-∞), 30.16 (8.87) µg·h/mL versus 28.49 (8.57) µg · h/mL. The 90% CIs of the ratios were as follows: base e logarithm (Ln)-transformed Cmax, 105.08% to 137.59%; Ln-AUC0-∞, 102.02% to 110.43%; and the difference in Tmax, -0.375 to -0.085 hours. CONCLUSIONS: The speed of release and absorption was statistically significantly higher with the test formulation compared with the reference one (evaluated using Tmax, Cmax, and Cmax/AUC parameters). This speed is especially important for a rapid analgesic or antipyretic effect.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA