Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Pract Radiat Oncol ; 5(6): e689-95, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26209122

RESUMO

PURPOSE: Stereotactic radiation therapy is an established treatment technique for intracranial malignancies. We evaluated a new intracranial immobilization system with an emphasis on determining the intrafraction motion and the correlation of this motion with treatment time. METHODS AND MATERIALS: Patients were immobilized using the trUpoint ARCH fixation system (CIVCO Medical Solutions). We collected data from 85 lesions in 73 patients treated between November 2011 and December 2013. Sixty-nine of 73 patients (95%) used the complete mask system; for the remaining 4 patients, the system had to be adapted. Patients were treated using volumetric modulated arc therapy stereotactic radiation therapy on a TrueBeam linear accelerator (Varian Medical Systems, Palo Alto, CA). Fraction doses of 2-8 Gy were applied in 4-30 fractions. Daily cone beam computed tomography imaging was performed before the treatment and was matched to the reference computed tomography using a 6-degrees-of-freedom automatching procedure. Additionally, posttreatment cone beam computed tomography scans were performed to assess intrafraction motion for 67 patients (375 fractions). RESULTS: The average 3-dimensional setup error was 2.1 ± 2.9 mm. The mean pitch and roll was -0.1 ± 0.7° and 0.2 ± 0.7°. A total of 98.0% of the pitch values and 98.9% of the roll values were <1.5°. Mean intrafractional motion was 0.51 mm (±0.27) and mean treatment time was 10.1 minutes (±1.4). The maximum intrafractional motion was 2.0 mm in the longitudinal direction; 95% of the total shifts were <1.4 mm. The linear regression showed a weak but significant influence (R(2) = 0.26, P = .01) of the treatment time on the total intrafractional shift. CONCLUSIONS: The new intracranial immobilization system appears to be robust in terms of setup accuracy, intrafraction motion, and repositioning of the mask system.


Assuntos
Neoplasias Encefálicas/radioterapia , Imobilização/métodos , Neoplasias/radioterapia , Posicionamento do Paciente , Radiocirurgia , Erros de Configuração em Radioterapia/prevenção & controle , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/secundário , Fracionamento da Dose de Radiação , Humanos , Pessoa de Meia-Idade , Neoplasias/patologia , Aceleradores de Partículas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Respiração , Carga Tumoral
2.
Radiother Oncol ; 106(2): 255-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23395063

RESUMO

PURPOSE: To investigate the clinical application of flattening filter free (FFF) beams at maximum dose rate for stereotactic body radiotherapy (SBRT). METHODS AND MATERIALS: Patients with tumors in the lung or abdomen were subjected to SBRT using 6 MV FFF or 10 MV FFF beams. For each patient, three plans were calculated using 6 MV flattened, 6 MV FFF, and 10 MV FFF beams. Treatment times were recorded and analyzed, and tumor displacements were assessed by pre- and post-treatment cone beam computed tomography (CBCT). RESULTS: Altogether, 26 patients (16 lung, 10 abdominal tumors) were treated. The average dose rate per patient ranged from 442 to 1860 MU/min. Beam-on time was on average 1.6 min (1SD=0.6 min), with the total treatment times recorded at 18.5 min (1SD=3.5 min). The time advantage of using FFF beams was dose-dependent and started at 4 Gy for 6 MV FFF and at 10 Gy for 10 MV FFF beams. The average of the tumor displacements during treatment was 2.0mm (1SD = 1.0mm). CONCLUSIONS: SBRT using FFF beams is time efficient and associated with excellent patient stability. According to Van Herk's formula, ITV-PTV margins of 6mm are sufficient in our patient cohort. Further studies are necessary to assess clinical outcome and toxicity.


Assuntos
Neoplasias Abdominais/cirurgia , Neoplasias Pulmonares/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Abdominais/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada de Feixe Cônico , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Pessoa de Meia-Idade , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA