Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Neonatal Perinatal Med ; 17(2): 241-246, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38701165

RESUMO

 Recent studies showed that COVID-19 infection can affect cochleo-vestibular system. The possibility of a vertical transmission is controversial. Some studies suggested that it is possible but unlikely, others find no evidence of vertical transmission. The objective of this study was to investigate whether exposure to COVID-19 during pregnancy or at birth has an impact on the hearing of the offspring. As part of the national hearing screening program, we performed in all newborns between January 2022 and February 2023, TEOAEs (Transient Evoked Otoacoustic Emissions) at birth and at 3 months. For those "REFER" at the third month test, we performed aABR (Automatic Auditory Brainstem Response) at 6 months. We analysed separately result between infants born to COVID-positive mothers during pregnancy and those born to COVID-negative mothers. To statistical verify differences we performed "Chi-square test". We enrolled a total of 157 infants, of whom 16 were born to mothers who had a molecular PCR test positive for COVID-19. In the latter we tested a total of 32 ears and only 1 ear (3,1%) resulted "REFER". On the other hand, in the control group we tested a total of 282 ears and 22 (7,8%) were found to be "REFER". Our study showed no significant differences in audiological assessment between newborns exposed to COVID-19 infection during pregnancy or at birth compared to the unexposed group. However, further studies with a larger patient's sample will be necessary for a more comprehensive evaluation.


Assuntos
COVID-19 , Transmissão Vertical de Doenças Infecciosas , Complicações Infecciosas na Gravidez , SARS-CoV-2 , Humanos , Feminino , COVID-19/diagnóstico , COVID-19/fisiopatologia , COVID-19/transmissão , Gravidez , Recém-Nascido , Complicações Infecciosas na Gravidez/fisiopatologia , Complicações Infecciosas na Gravidez/diagnóstico , Emissões Otoacústicas Espontâneas/fisiologia , Potenciais Evocados Auditivos do Tronco Encefálico , Triagem Neonatal/métodos , Masculino , Adulto , Lactente , Testes Auditivos/métodos
2.
Eur Phys J C Part Fields ; 81(10): 959, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34790033

RESUMO

We report the results of a search for a new vector boson ( A ' ) decaying into two dark matter particles χ 1 χ 2 of different mass. The heavier χ 2 particle subsequently decays to χ 1 and an off-shell Dark Photon A ' ∗ → e + e - . For a sufficiently large mass splitting, this model can explain in terms of new physics the recently confirmed discrepancy observed in the muon anomalous magnetic moment at Fermilab. Remarkably, it also predicts the observed yield of thermal dark matter relic abundance. A detailed Monte-Carlo simulation was used to determine the signal yield and detection efficiency for this channel in the NA64 setup. The results were obtained re-analyzing the previous NA64 searches for an invisible decay A ' → χ χ ¯ and axion-like or pseudo-scalar particles a → γ γ . With this method, we exclude a significant portion of the parameter space justifying the muon g-2 anomaly and being compatible with the observed dark matter relic density for A ' masses from 2 m e up to 390 MeV and mixing parameter ε between 3 × 10 - 5 and 2 × 10 - 2 .

3.
J Biomech ; 99: 109547, 2020 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-31831138

RESUMO

Workers in mining, mills, construction and some types of manufacturing are exposed to vibration that enters the body through the feet. Exposure to foot-transmitted vibration (FTV) is associated with an increased risk of developing vibration-induced white foot (VIWFt). VIWFt is a vascular and neurological condition of the lower limb, leading to blanching in the toes and numbness and tingling in the feet, which can be disabling for the worker. This paper presents a two-dimensional dynamic model describing the response of the foot-ankle system to vibration using four segments and eight Kelvin-Voigt models. The parameters of the model have been obtained by minimizing the quadratic reconstruction error between the experimental and numerical curves of the transmissibility and the apparent mass of participants standing in a neutral position. The average transmissibility at five locations on the foot has been optimized by minimizing the difference between experimental data and the model prediction between 10 and 100 Hz. The same procedure has been repeated to fit the apparent mass measured at the driving point in a frequency range between 2 and 20 Hz. Monte Carlo simulations were used to assess how the variability of the mass, stiffness and damping matrices affect the overall data dispersion. Results showed that the 7°-of-freedom model correctly described the transmissibility: the average transmissibility modulus error was 0.1. The error increased when fitting the transmissibility and apparent mass curves: the average modulus error was 0.3. However, the obtained values were reasonable with respect to the average inter-participant variability experimentally estimated at 0.52 for the modulus. Study results can contribute to the development of materials and equipment to attenuate FTV and, consequently, lower the risk of developing VIWFt.


Assuntos
Tornozelo/fisiologia , Pé/fisiologia , Modelos Biológicos , Vibração , Adulto , Humanos , Masculino , Posição Ortostática , Adulto Jovem
4.
Rev Sci Instrum ; 88(7): 073506, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28764505

RESUMO

Future fusion reactors are foreseen to be heated by the energetic alpha particles produced in fusion reactions. For this to happen, it is important that the energetic ions are sufficiently confined. In present day fusion experiments, energetic ions are primarily produced using external heating systems such as neutral beam injection and ion cyclotron resonance heating. In order to diagnose these fast ions, several different fast-ion diagnostics have been developed and implemented in the various experiments around the world. The velocity-space sensitivities of fast-ion diagnostics are given by so-called weight functions. Here instrument-specific weight functions are derived for neutron emission spectrometry detectors at the tokamaks JET and ASDEX Upgrade for the 2.45 MeV neutrons produced in deuterium-deuterium reactions in deuterium plasmas. Using these, it is possible to directly determine which part of velocity space each detector observes.

5.
Rev Sci Instrum ; 87(11): 11D823, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910604

RESUMO

A Single-crystal Diamond (SD) detector prototype was installed at Joint European Torus (JET) in 2013 and the achieved results have shown its spectroscopic capability of measuring 2.5 MeV neutrons from deuterium plasmas. This paper presents measurements of the SD response function to monoenergetic neutrons, which is a key point for the development of a neutron spectrometer based on SDs and compares them with Monte Carlo simulations. The analysis procedure allows for a good reconstruction of the experimental results. The good pulse height energy resolution (equivalent FWHM of 80 keV at 2.5 MeV), gain stability, insensitivity to magnetic field, and compact size make SDs attractive as compact neutron spectrometers of high flux deuterium plasmas, such as for instance those needed for the ITER neutron camera.

6.
Rev Sci Instrum ; 86(10): 103501, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26520949

RESUMO

Neutron spectroscopy measurements with a single crystal diamond detector have been carried out at JET, for the first time in an experiment aimed at accelerating deuterons to MeV energies with radio frequency heating at the third harmonic. Data are interpreted by means of the expected response function of the detector and are used to extract parameters of the highly non-Maxwellian distribution function generated in this scenario. A comparison with observations using a time of flight and liquid scintillator neutron spectrometers is also presented. The results demonstrate the capability of diamond detectors to contribute to fast ion physics studies at JET and are of more general relevance in view of the application of such detectors for spectroscopy measurements in the neutron camera of next step tokamak devices.

7.
Injury ; 45 Suppl 6: S80-4, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25457324

RESUMO

INTRODUCTION: Dislocated radial neck fractures of the third and fourth degree, according to the Judet classification, are rare events in children. These fractures account for 1% of all paediatric fractures. Their relatively low incidence is inversely proportional to the serious morphofuntional alterations that can follow without treatment. MATERIALS AND METHODS: Nine paediatric patients with an average age of 9.1 years (range 6-12 years), with radial neck fractures of the third and fourth degree, according to the Judet classification, were treated between 2010 and 2011. All patients underwent percutaneous reduction and fixation using only one K-wire by the same surgeon in a surgery time of 20 min (range 15-25 min). The average follow-up was 26.6 months (range 12-36 months), with X-rays and clinical evaluations conducted at four time points. The results were assessed radiologically (Métaizeau classification) and clinically (Mayo Clinic Elbow Performance Score). RESULTS: X-ray results (according to Métaizeau) were excellent in eight cases and good in one case. Clinical results were excellent in all cases. There was only one minor complication: a superficial skin infection that was treated with an oral antibiotic. DISCUSSION: The purpose of this study was to evaluate the results achieved in our hospital with a percutaneous reduction and fixation technique using only one K-wire in children with dislocated radial neck fractures of the third and fourth degree. The results obtained indicate that a single percutaneous surgery act that circumvents further operations is the best option for these patients. CONCLUSION: Although the number of patients in the study was small, the results are encouraging and support the continued use of this one-step percutaneous reduction and fixation technique.


Assuntos
Fios Ortopédicos , Fixação Interna de Fraturas , Consolidação da Fratura , Fraturas do Rádio/cirurgia , Criança , Feminino , Seguimentos , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Radiografia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/fisiopatologia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Resultado do Tratamento
8.
Rev Sci Instrum ; 85(11): 11E101, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430280

RESUMO

Single crystal Diamond Detectors (SDD) are being increasingly exploited for neutron diagnostics in high power fusion devices, given their significant radiation hardness and high energy resolution capabilities. The geometrical efficiency of SDDs is limited by the size of commercially available crystals, which is often smaller than the dimension of neutron beams along collimated lines of sight in tokamak devices. In this work, we present the design and fabrication of a 14 MeV neutron spectrometer consisting of 12 diamond pixels arranged in a matrix, so to achieve an improved geometrical efficiency. Each pixel is equipped with an independent high voltage supply and read-out electronics optimized to combine high energy resolution and fast signals (<30 ns), which are essential to enable high counting rate (>1 MHz) spectroscopy. The response function of a prototype SDD to 14 MeV neutrons has been measured at the Frascati Neutron Generator by observation of the 8.3 MeV peak from the (12)C(n, α)(9)Be reaction occurring between neutrons and (12)C nuclei in the detector. The measured energy resolution (2.5% FWHM) meets the requirements for neutron spectroscopy applications in deuterium-tritium plasmas.

9.
Rev Sci Instrum ; 85(11): 11E108, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430287

RESUMO

A matrix of Silicon Photo Multipliers has been developed for light readout from a large area 1 in. × 1 in. LaBr3 crystal. The system has been characterized in the laboratory and its performance compared to that of a conventional photo multiplier tube. A pulse duration of 100 ns was achieved, which opens up to spectroscopy applications at high counting rates. The energy resolution measured using radioactive sources extrapolates to 3%-4% in the energy range Eγ = 3-5 MeV, enabling gamma-ray spectroscopy measurements at good energy resolution. The results reported here are of relevance in view of the development of compact gamma-ray detectors with spectroscopy capabilities, such as an enhanced gamma-ray camera for high power fusion plasmas, where the use of photomultiplier is impeded by space limitation and sensitivity to magnetic fields.

10.
Rev Sci Instrum ; 85(4): 043506, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24784606

RESUMO

First simultaneous measurements of deuterium-deuterium (DD) and deuterium-tritium neutrons from deuterium plasmas using a Single crystal Diamond Detector are presented in this paper. The measurements were performed at JET with a dedicated electronic chain that combined high count rate capabilities and high energy resolution. The deposited energy spectrum from DD neutrons was successfully reproduced by means of Monte Carlo calculations of the detector response function and simulations of neutron emission from the plasma, including background contributions. The reported results are of relevance for the development of compact neutron detectors with spectroscopy capabilities for installation in camera systems of present and future high power fusion experiments.

11.
Rev Sci Instrum ; 84(12): 123505, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24393076

RESUMO

Measurements of the response of LaBr3(Ce) to 2.5 MeV neutrons have been carried out at the Frascati Neutron Generator and at tokamak facilities with deuterium plasmas. The observed spectrum has been interpreted by means of a Monte Carlo model. It is found that the main contributor to the measured response is neutron inelastic scattering on (79)Br, (81)Br, and (139)La. An extrapolation of the count rate response to 14 MeV neutrons from deuterium-tritium plasmas is also presented. The results are of relevance for the design of γ-ray diagnostics of fusion burning plasmas.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA