1.
Respir Med Case Rep ; 49: 102005, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38576859

RESUMO

This case report presents a numerical evaluation of respiration in terms of biomechanical parameters of chest motion. This experimental evaluation is performed with RESPIRholter, a wearable device specifically developed to monitor the movement in the ribcage through the motion of the sixth rib whose characteristic motion is considered as representative of the motion of the thorax. Here we present test results acquired with a RESPIRholter device in a 6-h acquisition. These results characterize respiration biomechanics for diagnostic purposes in a chest surgery patient, highlighting the diagnostic utility of RESPIRholter in the identification of post-operation respiratory problem.

2.
Biosensors (Basel) ; 14(2)2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38391991

RESUMO

One of the main challenges to be faced in deep space missions is to protect the health and ensure the maximum efficiency of the crew by preparing methods of prevention and in situ diagnosis. Indeed, the hostile environment causes important health problems, ranging from muscle atrophy, osteopenia, and immunological and metabolic alterations due to microgravity, to an increased risk of cancer caused by exposure to radiation. It is, therefore, necessary to provide new methods for the real-time measurement of biomarkers suitable for deepening our knowledge of the effects of space flight on the balance of the immune system and for allowing the monitoring of the astronaut's health during long-term missions. APHRODITE will enable human space exploration because it fills this void that affects both missions in LEO and future missions to the Moon and Mars. Its scientific objectives are the design, production, testing, and in-orbit demonstration of a compact, reusable, and reconfigurable system for performing the real-time analysis of oral fluid samples in manned space missions. In the frame of this project, a crew member onboard the ISS will employ APHRODITE to measure the selected target analytes, cortisol, and dehydroepiandrosterone sulfate (DHEA-S), in oral fluid, in four (plus one additional desired session) separate experiment sessions. The paper addresses the design of the main subsystems of the analytical device and the preliminary results obtained during the first implementations of the device subsystems and testing measurements on Earth. In particular, the system design and the experiment data output of the lab-on-chip photosensors and of the front-end readout electronics are reported in detail along with preliminary chemical tests for the duplex competitive CL-immunoassay for the simultaneous detection of cortisol and DHEA-S. Different applications also on Earth are envisaged for the APHRODITE device, as it will be suitable for point-of-care testing applications (e.g., emergency medicine, bioterrorism, diagnostics in developing countries, etc.).


Assuntos
Técnicas Biossensoriais , Voo Espacial , Humanos , Hidrocortisona , Desenho de Equipamento , Desidroepiandrosterona
3.
Cyborg Bionic Syst ; 4: 0046, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37681017

RESUMO

On-orbit assembly has become a crucial aspect of space operations, where the manipulator frequently and directly interacts with objects in a complex assembly process. The traditional manipulator control has limitations in adapting to diverse assembly tasks and is vulnerable to vibration, leading to assembly failure. To address this issue, we propose a human-like variable admittance control method based on the variable damping characteristics of the human arm. By collecting the velocity and contact force of human arm operations in assembly, we analyze the damping change of human arm and establish the active compliance model based on S-type damping variation rule in assembly. Furthermore, 3 passive contact models are proposed between the end of the human arm and the environment: one-sided bevel contact, both sides bevel contact, and pin-hole contact. On the basis of these active and passive models, a typical space assembly task for a robot is designed, and a human-like variable admittance controller is established and simulated. Finally, we build a ground verification platform and complete different assembly tasks, thereby successfully verifying the safety, robustness, and adaptability of the human-like variable admittance control method.

4.
Clin Biomech (Bristol, Avon) ; 100: 105769, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36228417

RESUMO

BACKGROUND: Existing devices detect main breathing data and none is aimed to monitor biomechanics of ventilation motions with small wearable device. METHODS: The used device has been designed for noninvasive wearing to detect main motion parameters of a rib during ventilation in an experimental campaign with 218 subjects. Experimental activity is carried out by testing in vivo with human volunteers for an experimental characterization of ventilation motions as related to normal breathing, maximal breathing and coughing. FINDINGS: Findings can be summarized from a numerical analysis of experimental results in terms of statistical values of ventilation motion parameters in rotation and acceleration as function of age and sex of the tested subjects. The discussed campaign reporting results on healthy patients was carried out with the aim to build a reference database of normal conditions against which the status of patients with both thoracic and ventilation problems can then be judged. Females showed significantly larger lateral-to-lateral movements during basal breathing and lateral-to-lateral Z-axis movements during maximal breathing and cough. Males demonstrated wider antero-posterior Y-axis and cranio-caudal X-axis movements during maximal breathing, while antero-posterior movements prevailed during cough. Older participants demonstrated larger lateral-to-lateral Z-axis and antero-posterior Y-axis movements during basal breathing. Young participants showed more significant increments along antero-posterior Y-axis from basal to maximal breathing and basal to cough, demonstrating a more efficient muscular activity. INTERPRETATION: The ventilation motion during ventilation act is useful to detect the status of ventilation and can give indications for diagnostics and medical solutions even in thoracic surgery.


Assuntos
Voluntários Saudáveis , Humanos
5.
Micromachines (Basel) ; 13(9)2022 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-36144171

RESUMO

In this paper, laboratory experiments of LARMbot torso V1 are reported in the third mode, thereby providing a testing characterization. Sensors were used to measure parameters including the contact force between the shoulder and cables, linear acceleration, angles of the torso body, and power consumption. The results showed that the LARMbot torso V1 can bend successfully to the desired angles, and that it is able to complete a full motion smoothly. The LARMbot torso V1 can mimic human-like motiaons. Based on our analysis of the test results, improvements are suggested, and new designs are considered.

6.
Artigo em Inglês | MEDLINE | ID: mdl-35329101

RESUMO

Chest compression is a parameter of injury criteria assessment for human beings. Additionally, it is used to find the external compression response as a result of vehicle crashes, falls, or sporting impacts. This behavioral feature is described by many deterministic models related to specific experimental tests, hindering distinct scenarios. The present study evaluates the energy absorbed as a function of rib compression. The proposed model was obtained from three different computed tomography (CT) studies. The anthropometric values are interpolated to obtain a parametric curve for a human rib's average size. The computed results are compared against an STL-DICOM® file used to obtain a virtual reconstruction of one rib. A numerical model of the behavior of the thorax displacement expressed injury in the human rib model's stiffness. The proposed model is used to determine the correlation of the input payload versus the numerical stiffness value. The outcome is confirmed by numerical analyses applied to a virtual human rib reconstruction.


Assuntos
Reanimação Cardiopulmonar , Traumatismos Torácicos , Humanos , Caixa Torácica , Tórax/diagnóstico por imagem , Tórax/fisiologia , Tomografia Computadorizada por Raios X
7.
Sensors (Basel) ; 22(4)2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-35214460

RESUMO

The paper examines the problem of respiration monitoring with easily wearable instrumentation by using a smart device that is properly designed and implemented with small and light components. The practical implementation is presented both in practical aspects and from experimental results by following a properly defined method with a medical-like protocol and specific procedure of testing. The results of a statistically significant campaign of experimental tests are reported with the characteristic data from the angles and acceleration components of a sensed rib both to validate the smart device and the procedure for respiration monitoring.


Assuntos
Cirurgia Torácica , Dispositivos Eletrônicos Vestíveis , Aceleração , Humanos , Monitorização Fisiológica , Respiração
8.
Life (Basel) ; 12(2)2022 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-35207600

RESUMO

This paper describes a new solution for an articulated low-cost artificial neck with sensors to assess the effects of head impacts. This prototype is designed as a new solution to evaluate the neck's response after suffering the head impact. An overview of existing solutions is reported to evaluate the advantages and disadvantages of each one briefly. Problems and requirements for prototype design are outlined to guide to a solution with commercial components. A prototype is developed, and its operating performance is evaluated through a lab test. Several tests are worked out considering the biomechanics involved in the most common accidents of head-neck impacts. Results show a response on the prototype similar to an actual human neck. Future improvements are also outlined for better accurate responses considering the results from the lab test.

9.
Sensors (Basel) ; 21(15)2021 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-34372386

RESUMO

An experimental characterization is presented for an improved version of a wearable assistive device for elbow motion. The design is revised with respect to requirements for elbow motion assistance, looking at applications both in rehabilitation therapies and exercising of elderly people. A laboratory prototype is built with lightweight, portable, easy-to-use features that are verified with test results, whose discussion is also provided as a characterization of operating performance.


Assuntos
Articulação do Cotovelo , Robótica , Tecnologia Assistiva , Idoso , Cotovelo , Desenho de Equipamento , Humanos , Amplitude de Movimento Articular
10.
Biomimetics (Basel) ; 6(1)2021 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-33803439

RESUMO

This paper presents a biomimetic prototype of a mobile robot that can be used to inspect the subdrainage conditions of pipelines located along different highways in Mexico. Computer-aided design tools have been used to size each of the prototype components as inspired by anatomical spider structure. Springs are integrated to generate proper contact pressure against the pipe walls. The robot locomotion system is implemented with adaptable behaviour for the irregularities of pipelines along its journey. The robot prototype is manufactured in 3D printing with the advantage of having its spare parts easily replaceable. Reported results show internal pipe status through a mini video camera on the top of the robot.

11.
Sensors (Basel) ; 19(3)2019 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-30696120

RESUMO

The muscles of the lower limbs directly influence leg motion, therefore, lower limb muscle exercise is important for persons living with lower limb disabilities. This paper presents a medical assistive robot with leg exoskeletons for locomotion and leg muscle exercises. It also presents a novel pedal-cycling actuation method with a crank-rocker mechanism. The mechanism is driven by a single motor with a mechanical structure that ensures user safety. A control system is designed based on a master-slave control with sensor fusion method. Here, the intended motion of the user is detected by pedal-based force sensors and is then used in combination with joystick movements as control signals for leg-exoskeleton and wheelchair motions. Experimental data is presented and then analyzed to determine robotic motion characteristics as well as the assistance efficiency with attached electromyogram (EMG) sensors. A typical muscle EMG signal analysis shows that the exercise efficiency for EMG activated amplitudes of the gluteus medius muscles approximates a walking at speed of 3 m/s when cycling at different speeds (i.e., from 16 to 80 r/min) in a wheelchair. As such, the present wheelchair robot is a good candidate for enabling effective gluteus medius muscle exercises for persons living with gluteus medius muscle disabilities.


Assuntos
Técnicas Biossensoriais/métodos , Terapia por Exercício , Músculo Esquelético/fisiologia , Robótica/métodos , Adulto , Nádegas/fisiologia , Eletromiografia/métodos , Exoesqueleto Energizado/normas , Estudos de Viabilidade , Pé/fisiologia , Humanos , Masculino , Contração Muscular/fisiologia , Força Muscular/fisiologia , Caminhada/fisiologia , Cadeiras de Rodas
12.
Appl Bionics Biomech ; 2018: 4357602, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30250502

RESUMO

This work presents the design of a low-cost prosthetic device for shoulder disarticulation. A proper design of the mechanisms has been addressed to obtain a prototype that presents 7 degrees of freedom. Shoulder movement is achieved by means of a spherical parallel manipulator, elbow movement is performed by a six-bar mechanism, and the wrist movement is implemented by a spherical parallel manipulator. A set of dynamic simulations was performed in order to assess the functionality of the design. The prototype was built using 3D printing techniques and implementing low-cost actuators. An experimental evaluation was carried out to characterize this device. The result of this work is a prototype that weighs 1350 g that is able to perform movements related to activities of daily living.

13.
J Healthc Eng ; 2018: 9303282, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30057735

RESUMO

This paper presents an experimental characterization of NURSE, a device for arm motion guidance. The laboratory setup and testing modes are presented to explain the experimental procedure. Two exercises for the upper limb exercise are used to test the NURSE behaviour, and successful results are presented. Trajectories and linear accelerations are tested when the device performs the two exercises without and with load. In addition, torque and power consumption are considered to check the NURSE behaviour.


Assuntos
Braço/fisiologia , Movimento (Física) , Reabilitação/instrumentação , Tecnologia Assistiva , Aceleração , Fenômenos Biomecânicos , Articulação do Cotovelo , Desenho de Equipamento , Terapia por Exercício , Humanos , Modelos Lineares , Músculo Esquelético , Análise de Regressão , Reabilitação/métodos , Reprodutibilidade dos Testes , Robótica , Articulação do Ombro , Torque