Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Oper Dent ; 48(3): 294-303, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36656317

RESUMO

This study aimed to compare the fracture toughness of molars with wide mesio-occlusal-distal (MOD) cavities restored with regular and flowable bulk-fill resin composite and a conventional resin composite after 250,000 mechanical cycles of chewing simulation. Thirty-two extracted mandibular third molars were selected and class II MOD cavities involving 2/3 of the intercuspal width and 4 mm depth were prepared. Teeth were divided into four groups based on resin composite type and insertion technique (n=8): (1) CT, unprepared teeth (control); (2) CV, conventional resin composite (Tetric N-Ceram, Ivoclar Vivadent) with incremental technique; (3) R-BF, regular bulk-fill resin composite (Tetric N-Ceram Bulk Fill, Ivoclar Vivadent) with a single increment; and (4) F-BF, flowable bulk-fill resin composite (Tetric N-Flow Bulk Fill, Ivoclar Vivadent) with a single increment, except for a 1-mm-thick layer at the occlusal surface, restored with conventional resin composite (Tetric N-Ceram). All specimens were evaluated to detect the presence and propagation of enamel cracks using a LED transilluminator before and after 250,000 mechanical cycles (SD Mechatronic GmbH). After a chewing simulation, they were subjected to a compressive force in a universal testing machine (DL-2000, EMIC) until fracture. The maximum fracture load of the specimens was measured (N) and the fracture patterns were classified based on the fracture site (above or below the cementoenamel junction [CEJ]). Data were statistically analyzed with one-way ANOVA. All specimens survived after 250,000 mechanical cycles, and no statistically significant differences among groups were observed regarding the fracture toughness (p<0.05). The fracture analysis demonstrated that failures below the CEJ were more common in CV (75%), while CT, R-BF, and F-BF showed this type of failure in 38%, 63%, and 63% of the specimens, respectively. The results of the crack analysis showed that the occurrence of new cracks and crack propagation was also higher in CV (33.3%), followed by R-BF, F-BF, and CT (14%, 14%, and 11% of the specimens, respectively). Teeth restored with regular and flowable bulk-fill composites showed similar fracture toughness after the chewing simulation compared to those restored with the conventional resin composite and unprepared teeth. Furthermore, teeth restored with both regular and flowable bulk-fill composites showed a lower incidence of enamel cracks and fractures below the CEJ compared to those restored with the conventional resin composite.


Assuntos
Resinas Compostas , Mastigação , Resinas Compostas/uso terapêutico , Resinas Acrílicas , Poliuretanos , Dente Molar , Teste de Materiais , Restauração Dentária Permanente/métodos
2.
J Mech Behav Biomed Mater ; 123: 104690, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34385065

RESUMO

OBJECTIVE: To characterize the effects of aging on the nanomechanical properties and 3D surface topographical parameters of an experimental Zirconia Toughened Alumina (ZTA) composite compared to its respective individual counterpart materials. METHODS: Disk-shaped specimens comprised of three material groups were processed: 1) ZTA 70/30 (70% alumina reinforced with 30% second-generation 3Y-TZP); 2) Zpex (Second-generation 3Y-TZP), and; 3) Al2O3 (High purity Alumina) (n = 10/material, 12 × 1 mm). After synthesis, ceramic powders were pressed, the green-body samples were sintered and polished. Nanoindentation testing was performed to record elastic modulus (E) and hardness (H). Interferometry was utilized to assess 3D surface roughness parameters (Sa, Sq), while X-ray diffraction (XRD) and scanning electron microscope (SEM) assessed the crystalline content and microstructure. All tests were performed before and after simulated aging (134°C, 2.2 bar, 20 h). Statistical analyses were performed using linear mixed-model and least square difference pos-hoc tests (α = 5%). RESULTS: XRD spectra indicated increase of monoclinic peaks for Zpex (~18%) relative to ZTA 70/30 (~2.5%) after aging. Additionally, aging did not affect the surface roughness parameters of ZTA 70/30 and Al2O3, although a significant increase in Sa was recorded for Zpex following aging (~90 nm) (p < 0.001). Al2O3 yielded the highest H and E values (H:21 GPa, E: 254 GPa), followed by ZTA 70/30 (H: 13 GPa, E: 214 GPa) and Zpex (H:11 GPa, E: 167 GPa), all significantly different (p < 0.03). CONCLUSION: ZTA 70/30 and Al2O3 presented high hydrothermal stability with respect to all evaluated variables, where artificial aging significantly increased the monoclinic content and surface roughness of Zpex.


Assuntos
Óxido de Alumínio , Ítrio , Cerâmica , Materiais Dentários , Teste de Materiais , Propriedades de Superfície , Zircônio
3.
Dent Mater ; 36(12): e365-e374, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32943230

RESUMO

OBJECTIVE: To evaluate the effect of aging on the microstructural, mechanical, and optical properties of an experimental zirconia-toughened alumina composite with 80%Al2O3 and 20%ZrO2 (ZTA Zpex) compared to a translucent zirconia (Zpex) and Alumina. METHODS: Disc-shaped specimens were obtained by uniaxial and isostatic pressing the synthesized powders (n = 70/material). After sintering and polishing, half of the specimens underwent aging (20 h, 134 °C, 2.2 bar). Crystalline content and microstructure were evaluated using X-ray diffraction and scanning electron microscopy, respectively. Specimens underwent biaxial flexural strength testing to determine the characteristic stress, Weibull modulus, and reliability. Translucency parameter (TP) and Contrast ratio (CR) were calculated to characterize optical properties. RESULTS: ZTA Zpex demonstrated a compact surface with a uniform dispersion of zirconia particles within the alumina matrix, and typical alumina and zirconia crystalline content. ZTA Zpex and alumina exhibited higher CR and lower TP than Zpex. ZTA Zpex and Zpex showed significantly higher characteristic stress relative to alumina. While aging did not affect optical and mechanical properties of ZTA Zpex and alumina, Zpex demonstrated a significant increase in translucency, as well as a in characteristic stress. Alumina reliability was significantly lower than others at 300 MPa, ZTA Zpex and Zpex reliability decreased at 800 MPa, except for aged Zpex. SIGNIFICANCE: While aging did not affect the mechanical nor the optical properties of ZTA Zpex and alumina, it did alter both properties of Zpex. The results encourage further investigations to engineer ZTA as a framework material for long span fixed dental prostheses specially where darkened substrates, such as titanium implant abutments or endodontically treated teeth, demand masking.


Assuntos
Óxido de Alumínio , Zircônio , Cerâmica , Materiais Dentários , Teste de Materiais , Reprodutibilidade dos Testes , Propriedades de Superfície
4.
J Mech Behav Biomed Mater ; 104: 103659, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32174417

RESUMO

PURPOSE: To synthesize a zirconia-toughened alumina (ZTA) composite with 85% alumina matrix reinforced by 15% zirconia and to characterize its optical and mechanical properties before and after artificial aging, to be compared with a conventional dental zirconia (3Y-TZP). MATERIAL AND METHODS: After syntheses, ZTA and 3Y-TZP powders were uniaxially and isostatically pressed. Green-body samples were sintered and polished to obtain 80 disc-shaped specimens per group (12 × 1 mm, ISO 6872:2015). The crystalline content and microstructure were characterized by X-ray diffraction (XRD) and scanning electron microscope (SEM). Optical properties were determined by the calculation of contrast ratio (CR) and translucency parameter (TP) using reflectance data. Mechanical properties were assessed by Vickers hardness, fracture toughness and biaxial flexural strength test (BFS). All analyses were conducted before and after artificial aging (20h, 134 °C, 0.22 MPa). Optical parameters and microhardness differences were evaluated through repeated-measures analysis of variance (p < 0.05). BFS data were analyzed using Weibull statistics (95% CI). RESULTS: The synthesis of the experimental ZTA composite was successful, with 98% of theoretical density, as shown in the SEM images. XRD patterns revealed typical zirconia and alumina crystalline phases. ZTA optical properties parameters showed no effect of aging, with a high CR and low TP values denoting a high masking-ability. 3Y-TZP presented lower masking-ability and aging significantly affected its optical properties. ZTA Vickers hardness, fracture toughness and Weibull parameters, including characteristic stress and Weibull modulus were not influenced by aging, while 3Y-TZP presented a significant decrease in characteristic stress and increase in fracture toughness after aging. The ZTA probability of survival for missions of 300 and 500 MPa was estimated at ~99% validating its use for 3-unit posterior fixed dental prostheses (FDP), and no different from conventional 3Y-TZP. At high-stress mission (800 MPa) a significant decrease in probability of survival was observed for aged 3Y-TZP (84%) and for immediate and aged ZTA (73 and 82% respectively). CONCLUSION: The ZTA composite presented a dense microstructure, with preservation of the crystalline content, optical and mechanical properties after artificial aging, which encourages future research to validate its potential use for large span FDP.


Assuntos
Óxido de Alumínio , Prótese Dentária , Cerâmica , Materiais Dentários , Teste de Materiais , Propriedades de Superfície , Ítrio , Zircônio
5.
Oper Dent ; 43(3): E119-E128, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29676981

RESUMO

PURPOSE: This study compared monolithic zirconia with conventional ones based on mean roughness (Ra), Vickers hardness (VHN), topography, transmittance, grain size, flexural strength (FS), Weibull modulus, and fractographic behavior. METHODS AND MATERIALS: One monolithic (Prettau Zircon [PR group]) and two conventional (ICE Zirkon Transluzent [IZ group] and BloomZir [BL group]) zirconias were used. Specimens were tested using a profilometer, a microhardness tester, a scanning electron microscope, a spectrophotometer, and a Universal Testing Machine (EMIC DL 2000). Ra, VHN, grain size, and transmittance were analyzed using the Kruskal-Wallis test associated with Dunn test (α=0.05). FS was analyzed using one-way analysis of variance with the Tukey honestly significant difference test (α=0.05). RESULTS: Means and standard deviations of roughness, after sintering (Ra, in µm) and VHN, were, respectively, 0.11 ± 0.01, 1452.16 ± 79.49, for the PR group; 0.12 ± 0.02, 1466.72 ± 91.76, for the IZ group; and 0.21 ± 0.08, 1516.06 ± 104.02, for the BL group. BL was statistically rougher ( p<0.01) than PR and IZ. Hardness was statistically similar ( p=0.30) for all groups. Means and standard deviations of FS (in MPa) were 846.65 ± 81.97 for the PR group, 808.88 ± 117.99 for the IZ group, and 771.81 ± 114.43 for the BL group, with no statistical difference ( p>0.05). Weibull moduli were 12.47 for the PR group, 7.24 for the IZ group, and 6.31 for the BL group, with no statistical differences. The PR and BL groups had higher transmittance values and grain sizes than the IZ group ( p<0.05). Although the BL group had some fractures that originated in the center of the tensile surface, fractographic analyses showed the same fracture pattern. CONCLUSIONS: All tested zirconia showed similar VHN, and the monolithic zirconia had similar roughness compared to one of the conventional zirconias. In addition, the monolithic zirconia showed similar flexural strength and Weibull modulus compared to the others even though its mean grain size was larger. The total transmittance of monolithic zirconia was higher than only one of the conventional zirconias tested.


Assuntos
Porcelana Dentária , Zircônio , Análise do Estresse Dentário , Dureza , Humanos , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Resistência à Tração
6.
J Dent Res ; 97(9): 1003-1009, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29608862

RESUMO

This investigation aimed at developing micropatterned silica thin films (MSTFs) containing nanohydroxyapatite (nano-HA) microaggregates that were not completely covered by silica so that they could directly interact with the surrounding cells. The objectives were 1) to evaluate the effect of the presence of 2 films (MSTF with or without nano-HA addition) on the characteristic strength (σ0) and Weibull modulus ( m) of a yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) and 2) to evaluate the effect of these 2 films, as applied onto the Y-TZP surface, on the morphology, orientation, and proliferation of MG63 cells. Sol-gel process and soft lithography were used to apply the MSTF onto the Y-TZP specimens. Three experimental groups were produced: Y-TZP, Y-TZP + MSTF, and Y-TZP + MSTF + sprayed nano-HA. All surfaces were characterized by scanning electron microscopy and energy-dispersive X-ray spectroscopy and tested for 4-point flexural strength ( n = 30) in water at 37 °C. Weibull analysis was used to determine m and σ0 (maximum likelihood method). In vitro biological behavior was performed with human osteoblast-like cells (MG63). Y-TZP was successfully coated with MSFT and MSFT + nano-HA. Scanning electron microscopy micrographs indicated that the microaggregates of nano-HA were not entirely covered by the silica. There was no statistically significant difference among the experimental groups for σ0 and m. In the groups containing the films, the cells were elongated and aligned along the lines. The MSFT + nano-HA group showed significantly higher cell metabolic activity than that obtained for the Y-TZP group at day 7. This investigation was successful in producing an MSTF containing nano-HA microaggregates that remained exposed to the environment. The developed films did not jeopardize the structural reliability of a commercial Y-TZP, as confirmed by the Weibull statistics. The MG63 cells seeded over the films became elongated and aligned along the films' micropatterned lines. Y-TZP specimens coated with MSTF and nano-HA showed a higher cell metabolic activity and proliferation after 7 d of culture when compared with uncoated Y-TZP.


Assuntos
Materiais Dentários/química , Nanoestruturas/química , Osteoblastos/efeitos dos fármacos , Dióxido de Silício/química , Ítrio/química , Zircônio/química , Proliferação de Células/efeitos dos fármacos , Resistência à Flexão , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Espectrometria por Raios X , Propriedades de Superfície
7.
Dent Mater ; 33(11): 1192-1204, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29017761

RESUMO

BACKGROUND: Clinical failure of dental ceramics is usually reported as partial fracture of the restoration (chipping) or as catastrophic fracture of the whole structure. In contrast to metals, ceramics are linear-elastic, brittle materials exhibiting extremely low damage tolerance to failure. Well documented clinical and lab reports have shown this fracture event often occurs at loads far below their fracture strength due to intrinsic fatigue degradation via slow crack growth or cyclic fatigue mechanisms. The presence and development of surface flaws have a dominant role in damage accumulation and lifetime reduction of ceramic structures. AIMS: This ADM guidance document aims to summarize the aspects related to fatigue degradation of dental ceramics, reviewing the concepts of fatigue testing and furthermore aims to provide practical guidance to young scientists entering into fatigue related research. The description of fatigue strength is always accompanied by a clear understanding of the underlying fracture mechanisms.


Assuntos
Cerâmica/química , Porcelana Dentária/química , Falha de Restauração Dentária , Análise do Estresse Dentário , Materiais Dentários/química , Teste de Materiais , Estresse Mecânico , Propriedades de Superfície
8.
Oper Dent ; 41(6): 634-641, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27820687

RESUMO

The aim of this study was to evaluate the influence of finishing and polishing systems and toothbrush abrasion on transmittance (T) and surface roughness (Ra) of three composite resins (Filtek Z350 XT, Tetric N-Ceram, and IPS Empress Direct). Eighteen resin disks (10 mm diameter × 2 mm thick) finished by polyester strips had initial surface smoothness recorded, representing phase 1 (P1). Specimens were divided into three groups (n=6) according to the finishing/polishing instrument used (OneGloss, TopGloss, and Sof-Lex) to compose phase 2 samples (P2). Then specimens were subjected to 514 cycles of toothbrush simulation using a toothpaste slurry, with a constant load applied to soft bristles, and were then washed (phase 3=P3). After each phase, the specimens were examined by an optical profiler and spectrophotometer to measure Ra and T. Data were analyzed by analysis of variance, Tukey and Pearson tests. T values were statistically influenced by composite resin ( p=0.000) and phase of measurement ( p=0.000) factors, while the finishing/polishing system used ( p=0.741) did not affect T. On the other hand, Ra values were statistically affected by the factor finishing/polishing system ( p=0.000), but not by composite resin ( p=0.100) and phase of measurement ( p=0.451). Tetric N-Ceram and Empress Direct presented higher values of roughness when polished by OneGloss, while TopGloss and Sof-Lex showed a lower roughness. It can be concluded that composite resins transmitted more light after dental abrasion. Transmittance of composite resins was not modified by the distinct roughness created by finishing/polishing instruments.


Assuntos
Resinas Compostas , Polimento Dentário , Análise de Variância , Teste de Materiais , Propriedades de Superfície , Escovação Dentária
9.
Oper Dent ; 41(4): E102-17, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27455117

RESUMO

This study aimed to evaluate the bond strength between dentin and five different ceramic inlays in permanent maxillary premolars, with and without mechanical cycling. One hundred permanent maxillary premolars were prepared and divided into 10 groups (n=10) according to the ceramic system (IPS e.Max Press; IPS e.Max CAD; Vita PM9; Vita Mark II; and Vita VM7) and the mechanical cycling factor (with and without [100 N, 2 Hz, 1.2×10(6) cycles]). The inlays were adhesively cemented, and all of the specimens were cut into microbars (1×1 mm, nontrimming method), which were tested under microtensile loading. The failure mode was classified and contact angle, roughness, and microtopographic analyses were performed on each ceramic surface. The mechanical cycling had a significant effect (p=0.0087) on the bond strength between dentin and IPS e.max Press. The Vita Mark II group had the highest bond strength values under both conditions, with mechanical cycling (9.7±1.8 MPa) and without (8.2±1.9 MPa), while IPS e.Max CAD had the lowest values (2.6±1.6 and 2.2±1.4, respectively). The adhesive failure mode at the ceramic/cement interface was the most frequent. Vita Mark II showed the highest value of average roughness. IPS e.max Press and Vita Mark II ceramics presented the lowest contact angles. In conclusion, the composition and manufacturing process of ceramics seem to have an influence on the ceramic surface and resin cement bond strength. Mechanical cycling did not cause significant degradation on the dentin and ceramic bond strength under the configuration used.


Assuntos
Cerâmica , Colagem Dentária , Porcelana Dentária , Restaurações Intracoronárias , Dentina , Humanos , Teste de Materiais , Cimentos de Resina , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
10.
Oper Dent ; 41(5): E118-E130, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26918927

RESUMO

Monolithic zirconia crowns have many favorable properties and may potentially be used to solve dental problems such as chipping. However, monolithic zirconia crown resistance can be affected by its phase transformation when subjected to low temperatures, humidity, and stress. This study evaluated the fracture load and phase transformation of monolithic zirconia crowns submitted to different thermal and mechanical aging tests. Seventy monolithic zirconia crowns were randomly divided into the following five groups: control, no treatment; hydrothermal aging at 122°C, two bar for one hour; thermal fatigue, 104 cycles between 5°C and 55°C, dwell time, 30 seconds; and mechanical fatigue, 106 cycles with a load of 70 N, sliding of 1.5 mm at 1.4 Hz; and combination of mechanical plus thermal fatigue. Fracture load was measured with a universal testing machine. Surface changes and fracture mode and origin were examined with a scanning electron microscope. Monoclinic phase content was evaluated by x-ray diffraction. The fracture load was analyzed using one-way analysis of variance at a level of 5%, and Weibull distribution was performed. No statistically significant differences were observed in the mean fracture load and characteristic fracture load among the groups (p>0.05). The Weibull modulus ranged from 6.2 to 16.6. The failure mode was similar for all groups with the crack origin located at the contact point of the indenter. Phase transformation was shown at different surfaces of the crown in all groups (1.9% to 8.9%). In conclusion, monolithic zirconia crowns possess high fracture load, structural reliability, and low phase transformation.

11.
J Mech Behav Biomed Mater ; 45: 183-92, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25746851

RESUMO

This study evaluated the effects of low-temperature aging on the surface topography, phase transformation, biaxial flexural strength, and structural reliability of a ground Y-TZP ceramic. Disc-shaped specimens were manufactured and divided according to two factors: "grinding" - without grinding (as-sintered, Ctrl), grinding with an extra-fine diamond bur (25 µm Xfine) and coarse diamond bur (181 µm Coarse); and "low-temperature-aging" (absence or presence). Grinding was performed using a contra-angle handpiece under water-cooling. Aging was performed in an autoclave at 134 °C, under 2 bar, over a period of 20 h. Surface topography analysis showed an increase in roughness based on grit-size (Coarse>Xfine>Ctrl), and aging promoted different effects on roughness (Ctrl AgCoarse). Grinding and aging promoted an increase in the amount of m-phase, although different susceptibilities to degradation were observed. Weibull analysis showed an increase in characteristic strength after grinding (Coarse=Xfine>Ctrl); however, distinct effects were observed for aging (CtrlCoarse Ag). Weibull moduli were statistically similar. Grinding promoted an increase in characteristic strength as a result of an increase in m-phase content; when the Y-TZP surface was ground by coarse diamond burs followed by aging, characteristic strength was reduced, meaning the low-temperature degradation appeared to intensify for rougher Y-TZP surfaces.


Assuntos
Fenômenos Mecânicos , Temperatura , Ítrio , Zircônio , Transição de Fase , Propriedades de Superfície , Fatores de Tempo , Ítrio/química , Zircônio/química
12.
Oper Dent ; 40(3): 247-54, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25268041

RESUMO

This work tested CO2 laser as a glazing agent and investigated the effects of irradiation on the porosity, translucency, and mechanical properties of veneering porcelain. Sixty discs (diameter 3.5 × 2.0 mm) of veneering porcelain for Y-TZP frameworks (VM9, VITA Zahnfabrik) were sintered and had one of their faces mirror polished. The specimens were divided into six groups (n=10/group) according to surface treatment, as follows: no treatment-control; auto-glaze in furnace following manufacturer's instructions (G); and CO2 laser (45 or 50 W/cm(2)) applied for four or five minutes (L45/4, L45/5, L50/4, L50/5). Optical microscopy (Shimadzu, 100×) was conducted and the images were analyzed with Image J software for the determination of the following porosity parameters: area fraction, average size, and Feret diameter. The translucency parameter studied was masking ability, determined by color difference (ΔE) over black and white backgrounds (CM3370d, Konica Minolta). Microhardness and fracture toughness (indentation fracture) were measured with a Vickers indenter (HMV, Shimadzu). Contact atomic force microscopy (AFM) (50 × 50 µm(2), Nanoscope IIIA, Veeco) was performed at the center of one sample from each group, except in the case of L45/5. With regard to porosity and translucency parameters, auto-glazed and laser-irradiated specimens presented statistical similarity. The area fraction of the surface pores ranged between 2.4% and 5.4% for irradiated specimens. Group L50/5 presented higher microhardness when compared to the G group. The higher (1.1) and lower (0.8) values for fracture toughness (MPa.m(1/2)) were found in laser-irradiated groups (L50/4 and L45/4, respectively). AFM performed after laser treatment revealed changes in porcelain surface profile at a submicrometric scale, with the presence of elongated peaks and deep valleys.


Assuntos
Porcelana Dentária/efeitos da radiação , Facetas Dentárias , Lasers de Gás/uso terapêutico , Porcelana Dentária/normas , Análise do Estresse Dentário , Facetas Dentárias/normas , Dureza , Humanos , Microscopia de Força Atômica , Porosidade , Propriedades de Superfície
13.
Oper Dent ; 40(1): E1-E10, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25162722

RESUMO

This study evaluated the effect of the cement type (adhesive resin, self-adhesive, glass ionomer, and zinc phosphate) on the retention of crowns made of yttria-stabilized polycrystalline tetragonal zirconia (Y-TZP). Therefore, 108 freshly extracted molars were embedded in acrylic resin, perpendicular to their long axis, and prepared for full crowns: the crown preparations were removed and reconstructed using composite resin plus fiber posts with dimensions identical to the prepared dentin. The preparations were impressed using addition silicone, and Y-TZP copings were produced, which presented a special setup for the tensile testing. Cementation was performed with two adhesive resin cements (Multilink Automix, Ivoclar-Vivadent; RelyX ARC, 3M ESPE, St Paul, MN, USA), one self-adhesive resin cement (RelyX U100, 3M ESPE), one glass ionomer based cement (RelyX Luting, 3M ESPE), and one zinc phosphate cement (Cimento de Zinco, SS White, Rio de Janeiro, Brazil). For the resin cement groups, the inner surfaces of the crowns were subjected to three surface treatments: cleaning with isopropyl alcohol, tribochemical silica coating, or application of a thin low-fusing glass porcelain layer plus silanization. After 24 hours, all groups were subjected to thermocycling (6000 cycles) and included in a special device for tensile testing in a universal testing machine to test the retention of the infrastructure. After testing, the failure modes of all samples were analyzed under a stereomicroscope. The Kruskal-Wallis test showed that the surface treatment and cement type (α=0.05) affected the tensile retention results. The Multilink cement presented the highest tensile retention values, but that result was not statistically different from RelyX ARC. The surface treatment was statistically relevant only for the Multilink cement. The cement choice was shown to be more important than the crown surface treatment for cementation of a Y-TZP crown to a composite resin substrate.


Assuntos
Coroas , Cimentos de Resina/uso terapêutico , Ítrio/uso terapêutico , Zircônio/uso terapêutico , Bis-Fenol A-Glicidil Metacrilato/uso terapêutico , Coroas/normas , Corrosão Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro/uso terapêutico , Humanos , Fosfatos/uso terapêutico , Polietilenoglicóis/uso terapêutico , Ácidos Polimetacrílicos/uso terapêutico , Resinas Sintéticas/uso terapêutico , Resistência à Tração , Compostos de Zinco/uso terapêutico
14.
J Mech Behav Biomed Mater ; 37: 133-40, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24905180

RESUMO

This study compared the effects of grinding on the surface micromorphology, phase transformation (t→m), biaxial flexural strength and structural reliability (Weibull analysis) of a Y-TZP (Lava) ceramic using diamond-discs and -burs. 170 discs (15×1.2mm) were produced and divided into 5 groups: without treatment (Ctrl, as-sintered), and ground with 4 different systems: extra-fine (25µm, Xfine) and coarse diamond-bur (181µm, Coarse), 600-grit (25µm, D600) and 120-grit diamond-disc (160µm, D120). Grinding with burs was performed using a contra-angle handpiece (T2-Revo R170, Sirona), while for discs (Allied) a Polishing Machine (Ecomet, Buehler) was employed, both under water-cooling. Micromorphological analysis showed distinct patterns generated by grinding with discs and burs, independent of grit size. There was no statistical difference for characteristic strength values (MPa) between smaller grit sizes (D600 - 1050.08 and Xfine - 1171.33), although they presented higher values compared to Ctrl (917.58). For bigger grit sizes, a significant difference was observed (Coarse - 1136.32>D120 - 727.47). Weibull Modules were statistically similar between the tested groups. Within the limits of this study, from a micromorphological point-of-view, the treatments performed did not generate similar effects, so from a methodological point-of-view, diamond-discs should not be employed to simulate clinical abrasion performed with diamond-burs on Y-TZP ceramics.


Assuntos
Cerâmica/química , Diamante/química , Fenômenos Mecânicos , Ítrio/química , Zircônio/química , Relação Estrutura-Atividade , Propriedades de Superfície
15.
Oper Dent ; 39(6): 619-26, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24809542

RESUMO

This study evaluated the effect of the core substrate type (dentin and composite resin) on the retention of crowns made of yttrium oxide stabilized tetragonal zirconia polycrystal (Y-TZP), submitted to three inner surface conditionings. For this purpose, 72 freshly extracted molars were embedded in acrylic resin, perpendicular to the long axis, and prepared for full crowns: 36 specimens had crown preparations in dentin; the remaining 36 teeth had the crowns removed, and crown preparations were reconstructed with composite resin plus fiber posts with dimensions identical to the prepared dentin. The preparations were impressed using addition silicone, and 72 Y-TZP copings for the tensile test were produced. Cementation was performed with a dual-cured cement containing phosphate monomers. For cementation, the crown preparation (dentin or resin) was conditioned with the adhesive system, and the ceramic was subjected to one of three surface treatments: isopropyl alcohol, tribochemical silica coating, or thin low-fusing glassy porcelain layer application plus silanization. After 24 hours, all specimens were submitted to thermocycling (6000 cycles) and placed in a special tensile testing device in a universal testing machine to determine failure loads. The failure modes of all samples were analyzed under a stereomicroscope. Two-way analysis of variance showed that the surface treatment and substrate type (α=0.05) affected the tensile retention results. The dentin substrate presented the highest tensile retention values, regardless of the surface treatment. When the substrate was resin, the tribochemical silica coating and low-fusing glaze application plus silanization groups showed the higher retention values.


Assuntos
Coroas , Teste de Materiais , Resistência à Tração , Propriedades de Superfície
16.
Dent Mater ; 30(2): 105-11, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24238558

RESUMO

OBJECTIVES: The residual stress profile developed within the veneering ceramic during the manufacturing process is an important predicting factor in chipping failures, which constitute a well-known problem with yttria-tetragonal-zirconia polycrystal (Y-TZP) based restorations. The objectives of this study are to measure and to compare the residual stress profile in the veneering ceramic layered on three different polycrystalline ceramic framework materials: Y-TZP, alumina polycrystal (AL) and zirconia toughened alumina (ZTA). METHODS: The stress profile was measured with the hole-drilling method in bilayered disk samples of 19 mm diameter with a 0.7 mm thick Y-TZP, AL or ZTA framework and a 1.5mm thick layer of the corresponding veneering ceramic. RESULTS: The AL samples exhibited increasing compressive stresses with depth, while compressive stresses switching into interior tensile stresses were measured in Y-TZP samples. ZTA samples exhibited compressive stress at the ceramic surface, decreasing with depth up to 0.6mm from the surface, and then becoming compressive again near the framework. SIGNIFICANCE: Y-TZP samples exhibited a less favorable stress profile than those of AL and ZTA samples. Results support the hypothesis of the occurrence of structural changes within the Y-TZP surface in contact with the veneering ceramic to explain the presence of tensile stresses. Even if the presence of Y-TZP in the alumina matrix seems to negatively affect the residual stress profiles in ZTA samples in comparison with AL samples, the registered profiles remain positive in terms of veneer fracture resistance.


Assuntos
Óxido de Alumínio/química , Cerâmica , Facetas Dentárias , Estresse Mecânico , Ítrio/química , Zircônio/química , Microscopia Eletrônica de Varredura
17.
Oper Dent ; 37(4): 370-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22816499

RESUMO

OBJECTIVES: This study evaluated the degree of conversion (DC) and working time (WT) of two commercial, dual-cured resin cements polymerized at varying temperatures and under different curing-light accessible conditions, using Fourier transformed infrared analysis (FTIR). MATERIALS AND METHODS: Calibra (Cal; Dentsply Caulk) and Variolink II (Ivoclar Vivadent) were tested at 25°C or preheated to 37°C or 50°C and applied to a similar-temperature surface of a horizontal attenuated-total-reflectance unit (ATR) attached to an infrared spectrometer. The products were polymerized using one of four conditions: direct light exposure only (600 mW/cm(2)) through a glass slide or through a 1.5- or 3.0-mm-thick ceramic disc (A2 shade, IPS e.max, Ivoclar Vivadent) or allowed to self-cure in the absence of light curing. FTIR spectra were recorded for 20 min (1 spectrum/s, 16 scans/spectrum, resolution 4 cm(-1)) immediately after application to the ATR. DC was calculated using standard techniques of observing changes in aliphatic-to-aromatic peak ratios precuring and 20-min postcuring as well as during each 1-second interval. Time-based monomer conversion analysis was used to determine WT at each temperature. DC and WT data (n=6) were analyzed by two-way analysis of variance and Tukey post hoc test (p=0.05). RESULTS: Higher temperatures increased DC regardless of curing mode and product. For Calibra, only the 3-mm-thick ceramic group showed lower DC than the other groups at 25°C (p=0.01830), while no significant difference was observed among groups at 37°C and 50°C. For Variolink, the 3-mm-thick ceramic group showed lower DC than the 1-mm-thick group only at 25°C, while the self-cure group showed lower DC than the others at all temperatures (p=0.00001). WT decreased with increasing temperature: at 37°C near 70% reduction and at 50°C near 90% for both products, with WT reduction reaching clinically inappropriate times in some cases (p=0.00001). CONCLUSION: Elevated temperature during polymerization of dual-cured cements increased DC. WT was reduced with elevated temperature, but the extent of reduction might not be clinically acceptable.


Assuntos
Cimentos de Resina/química , Bis-Fenol A-Glicidil Metacrilato/química , Cerâmica/química , Lâmpadas de Polimerização Dentária , Materiais Dentários/química , Fluoretos/química , Vidro/química , Temperatura Alta , Humanos , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Metacrilatos/química , Polietilenoglicóis/química , Polimerização , Ácidos Polimetacrílicos/química , Poliuretanos/química , Autocura de Resinas Dentárias , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Temperatura , Fatores de Tempo , Itérbio/química
18.
Oper Dent ; 29(2): 212-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15088734

RESUMO

The objectives of this study include comparing the cement thickness and microleakage of Class II ceramic inlays built with three ceramic systems and verifying whether there was a correlation between those two variables. The ceramic systems used include: 1) Heat-pressed (IPS-Empress); 2) CAD-CAM (CEREC 2) and 3) Sintered (Colorlogic). Standardized MOD Class II inlay cavities with one proximal box extending below and the other extending above the cement-enamel junction (CEJ) were prepared in 30 extracted human molars and randomly assigned to three groups. The ceramic inlays were constructed according to manufacturer's instructions and cemented using a dual-cure resin cement (Variolink II). All teeth were mechanically cycled (100,000 cycles, 78N) and thermocycled (700 cycles, 5 degrees C-55 degrees C). After immersion in silver nitrate, the inlays were sectioned mesial-distally and evaluated with an optical microscope (40x). The cement thickness obtained by the Colorlogic system (enamel: 113 +/- 25 microm; dentin: 118 +/- 23 microm) was significantly higher than that obtained by CEREC (enamel: 78 +/- 14 microm; dentin: 87 +/- 13 microm) and Empress (enamel: 65 +/- 15 microm; dentin: 89 +/- 14 microm). Regarding dye penetration, there was no statistical difference among the three ceramic systems in enamel. At the dentin margins, the Colorlogic system resulted in a significantly higher penetration depth compared to CEREC and Empress, which had similar average values. No correlation was found between cement thickness and microleakage either in enamel or dentin for any of the ceramic systems.


Assuntos
Cimentação , Infiltração Dentária , Porcelana Dentária , Restaurações Intracoronárias/métodos , Cimentos de Resina , Silicatos de Alumínio , Cerâmica , Preparo da Cavidade Dentária , Infiltração Dentária/prevenção & controle , Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Humanos , Dente Molar , Distribuição Aleatória
19.
J Oral Rehabil ; 29(3): 257-62, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11896842

RESUMO

Dual-cured cements have been studied in terms of the hardness or degree of conversion achieved with different curing modes. However, little emphasis is given to the influence of the curing method on other mechanical properties. This study investigated the flexural strength, flexural modulus and hardness of four proprietary resin cements. Materials tested were: Enforce and Variolink II (light-, self- and dual-cured), RelyX ARC (self- and dual-cured) and C & B (self-cured). Specimens were fractured using a three-point bending test. Pre-failure loads corresponding to specific displacements of the cross-head were used for flexural modulus calculation. Knoop hardness (KHN) was measured on fragments obtained after the flexural test. Tests were performed after 24 h storage at 37 degrees C. RelyX ARC dual-cured showed higher flexural strength than the other groups. RelyX ARC and Variolink II depended upon photo-activation to achieve higher hardness values. Enforce showed similar hardness for dual- and self-curing modes. No correlation was found between flexural strength and hardness, indicating that other factors besides the degree of cure (e.g. filler content and monomer type) affect the flexural strength of composites. No statistical difference was detected in the flexural modulus among the different groups.


Assuntos
Cimentos de Resina/química , Análise de Variância , Bis-Fenol A-Glicidil Metacrilato/química , Compostos de Boro/química , Resinas Compostas/química , Elasticidade , Dureza , Humanos , Luz , Teste de Materiais , Metacrilatos/química , Metilmetacrilatos/química , Maleabilidade , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Estatística como Assunto , Estresse Mecânico , Propriedades de Superfície , Temperatura , Fatores de Tempo
20.
J Prosthet Dent ; 86(3): 289-96, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11552166

RESUMO

STATEMENT OF PROBLEM: Fracture resistance, elastic modulus, and hydrolytic degradation resistance are important properties of indirect composite restorations. Composite systems developed specifically for indirect application are said to have enhanced mechanical properties due to their elevated monomer conversion. PURPOSE: This study evaluated the influence of shade and the effect of 30-day water storage on the flexural strength, flexural modulus, and hardness of 4 commercially available indirect composite systems and 1 composite used with the direct technique. MATERIAL AND METHODS: A variety of commercially available indirect resin composites (Artglass, Belleglass, Sculpture, and Targis) and 1 directly placed composite (Z100, control) were used. Specimens made with either incisal or dentin shade (n = 10) were fractured with a 3-point bending test. Pre-failure loads corresponding to specific displacements of the crosshead were used for flexural modulus calculation. Knoop hardness was measured on fragments (n = 3) obtained after the flexural test. Tests were performed after 24 hours and after a 30-day water storage at 37 degrees C. Flexural strength data were analyzed with the Weibull distribution. Flexural modulus and Knoop hardness data were analyzed with 3-way ANOVA and Tukey's post-hoc test (alpha=0.05). RESULTS: In general, the directly placed composite (Z100) demonstrated flexural strength similar to that of Artglass, Targis, and Sculpture. Belleglass presented the highest flexural strength (221.7 MPa for incisal shade after 24 hours storage; 95% confidence interval: 208.3-235.4). Z100 demonstrated the highest flexural modulus (range: 10.9 +/- 0.6 to 12.0 +/- 0.9 GPa) and Targis the lowest (range: 5.1 +/- 0.5 to 5.9 +/- 0.9 GPa). Sculpture was the only material that showed differences in flexural strength with respect to shade (incisal-24 hours: 149.8 MPa; incisal-30 days: 148.7 MPa; dentin-24 hours: 200.0 MPa; dentin-30 days: 177.9 MPa). The flexural modulus and hardness of the dentin shade of Sculpture were higher than those of the incisal shade after 30 days. Belleglass also showed a significant difference in flexural modulus (dentin-24 hours: 11.1 GPa; incisal-24 hours: 9.6 GPa). The effect of water storage was more evident on hardness since all composite systems softened after 30 days. Prolonged water storage decreased flexural strength only for Artglass-dentin and Z100, both incisal and dentin shades. Water aging did not affect the flexural modulus of any composite tested. CONCLUSION: In general, indirect composites did not show enhanced mechanical properties compared to the directly placed composite. Property differences due to shade were more evident for Sculpture. Prolonged water storage had a deleterious effect on the hardness of all composites tested. However, water storage did not affect the flexural strength of most of the indirect composites or the flexural modulus of any composite tested.


Assuntos
Resinas Compostas/química , Restauração Dentária Permanente/métodos , Zircônio , Análise de Variância , Compostos de Bário/química , Cor , Intervalos de Confiança , Elasticidade , Cimentos de Ionômeros de Vidro/química , Dureza , Humanos , Hidrólise , Metacrilatos/química , Maleabilidade , Cimento de Policarboxilato/química , Cimento de Silicato/química , Dióxido de Silício/química , Estatística como Assunto , Estresse Mecânico , Temperatura , Fatores de Tempo , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA