Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Pulm Med ; 24(1): 466, 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-39304863

RESUMO

BACKGROUND: Most malignant peripheral pulmonary lesions (PPLs) are situated in the peripheral region of the lung. Although the ultrathin bronchoscope (UTB) can access these areas, a robust navigation system is essential for precise localisation of these small peripheral PPLs. Since many UTB procedures rely on automated virtual bronchoscopic navigation (VBN), this study aims to determine the accuracy and diagnostic yield of the manual bronchial branch tracing (BBT) navigation in UTB-guided radial endobronchial ultrasound (rEBUS) procedures. METHODS: Single-centre retrospective study of UTB-rEBUS patients with PPLs smaller than 3 cm over a two year period. RESULTS: Our cohort consisted of 47 patients with a mean age of 61.6 (SD 9.53) years and a mean target size of 1.91 (SD 0.53) cm. Among these lesions, 46.8% were located in the 6th airway generation, and 78.7% exhibited a direct bronchus sign. Navigation success using BBT was 91.5% based on positive rEBUS identification. The index diagnostic yield was 82.9%, increasing to 91.5% at 12 months of follow-up. Malignant lesions accounted for 65.1% of cases, while 34.9% were non-malignant. The presence of a direct bronchus sign was the sole factor associated with higher navigation success and diagnostic yield. Cryobiopsy outperformed forceps biopsy in non-concentric rEBUS lesions (90.9% vs. 50.0%, p < 0.05), but not in concentric orientated lesions. One pneumothorax occurred in our cohort. CONCLUSIONS: BBT as an exclusive navigation method for small PPLs in UTB-rEBUS procedures has proved to be safe and feasible. Combination of UTB with cryobiopsy remains efficient for eccentric and adjacently oriented rEBUS lesions.


Assuntos
Broncoscopia , Endossonografia , Neoplasias Pulmonares , Humanos , Pessoa de Meia-Idade , Broncoscopia/métodos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Endossonografia/métodos , Nódulo Pulmonar Solitário/patologia , Nódulo Pulmonar Solitário/diagnóstico por imagem , Brônquios/patologia , Brônquios/diagnóstico por imagem
2.
Artigo em Inglês | MEDLINE | ID: mdl-39119870

RESUMO

BACKGROUND: Transbronchial cryobiopsy is a promising technique for biopsy of peripheral pulmonary lesions (PPL). However, cryobiopsy specimen retrieval can pose problems due to the risk of bleeding during the blind period when the bronchoscope and cryoprobe are removed en bloc. Artificial airways and prophylactic balloon placement are risk-reducing measures, but the latter is challenging in upper lobe PPL. Specimen retrieval through standard guide sheath (GS) system without the need for bronchoscope removal may now be feasible with the ultrathin cryoprobe. METHODS: Retrospective review of radial endobronchial ultrasound (rEBUS)-guided transbronchial cryobiopsy for PPL cases in which cryobiopsy specimen was retrieved through the GS over a 6-month period. RESULTS: Twenty patients were included with an overall median age of 66.50 (IQR: 53.0 to 76.7). The median procedural time was 30 (IQR: 25.0 to 33.7) minutes. Median target size was 3.20 (IQR: 2.17 to 4.84) cm with 85% of lesions demonstrated "within" rEBUS orientation. Overall technical feasibility was 85% with median cryoactivation of 4.0 (IQR: 3.0 to 4.0) seconds. No specimen was retrieved in 3 patients. The diagnostic yield for forceps and cryobiopsy was 70% and 60%, respectively, and the combined diagnostic yield was 85% (P<0.01 vs. forceps biopsy). Median aggregate size for forceps and cryobiopsy was 8.0 (IQR: 5.3 to 10.0) and 4.5 (IQR: 2.3 to 7.0) mm respectively (P<0.01). No pneumothorax was reported and mild self-limiting bleeding was encountered in 30% of cases. CONCLUSION: Retrieval of cryoprobe through standard GS appears to be a safe and feasible method that can simplify the transbronchial cryobiopsy procedure and complement forceps biopsy in specific cases.


Assuntos
Broncoscopia , Criocirurgia , Estudos de Viabilidade , Humanos , Idoso , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Feminino , Broncoscopia/métodos , Broncoscopia/instrumentação , Criocirurgia/métodos , Criocirurgia/instrumentação , Biópsia/métodos , Biópsia/instrumentação , Pulmão/patologia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Manejo de Espécimes/métodos
3.
Respirol Case Rep ; 12(8): e01450, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39130086

RESUMO

Bleeding mitigation is an important part of any transbronchial lung cryobiopsy (TBLC) procedure, either for interstitial lung disease (ILD) or peripheral pulmonary lesions (PPL). The two-scope technique has been previously described for ILD and PPL-TBLC, but it has its own limitations and technical and logistical complexities. In this case series, we describe a modified two-scope technique that enhances the conventional two-scope technique by maintaining a small equipment footprint and longer bronchoscopic vision without the need for intra-procedure switching of bronchoscopes. Three cases of PPLs were navigated by standard radial endobronchial ultrasound and biopsied with the 1.1 mm flexible ultrathin cryoprobe. All cases achieved a conclusive diagnosis with adequate specimens for immunohistochemical staining and molecular analysis; only Grade 1 bleeding reported in two cases. The challenges and limitations of this modified two-scope technique were also explored in this series.

4.
Sci Rep ; 14(1): 18653, 2024 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-39134712

RESUMO

EBUS-guided transbronchial mediastinal cryobiopsy (TBMC) has emerged as a promising biopsy tool for diagnosing hilar and mediastinal pathologies. However, several fundamental technical aspects of TBMC remain unexplored. This study aims to determine the optimal number of cryo-passes and freezing time of the ultrathin cryoprobe in EBUS-TBMC concerning specimen size and procedural diagnostic yield. We conducted a retrospective chart review of patients with mediastinal and hilar lesions who underwent EBUS-TBMC between January 2021 and April 2023 across three hospitals in Malaysia. A total of 129 EBUS-TBMC procedures were successfully completed, achieving an overall diagnostic yield of 88.4%. Conclusive TBMC procedures were associated with larger specimen sizes (7.0 vs. 5.0 mm, p < 0.01). Specimen size demonstrated a positive correlation with diagnostic yield (p < 0.01), plateauing at specimen size of 4.1-6.0 mm. A significant positive correlation was also observed between the number of cryo-passes and both specimen size (p < 0.01) and diagnostic yield (p < 0.05). Diagnostic yield plateaued after 2-3 cryo-passes. In contrast, longer freezing times trended towards smaller specimens and lower diagnostic yield, though not reaching statistical significance. The highest diagnostic yield was recorded at the 3.1-4.0 s freezing time. The safety profile of TBMC remains favourable, with one case (0.8%) of pneumothorax and nine cases (7%) of self-limiting bleeding. In our cohort, TBMC performance with 2-3 cryo-passes and a 3.1-4.0 s freezing time to achieve a total aggregate specimen size of 4.1-6.0 mm appeared optimal. Further prospective studies are needed to validate these findings.


Assuntos
Criocirurgia , Congelamento , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Criocirurgia/métodos , Criocirurgia/instrumentação , Mediastino/patologia , Adulto , Broncoscopia/métodos , Broncoscopia/instrumentação
5.
ERJ Open Res ; 10(1)2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38259810

RESUMO

In PPL-TBLC, quality of tissue matters more than quantity for accurate diagnosis. Comparable diagnostic yield with 1.1-mm cryoprobe can potentially be achieved in 6 s of freezing and three or more passes. https://bit.ly/49cbmbW.

7.
J Thorac Dis ; 15(11): 6072-6083, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38090299

RESUMO

Background: Peripheral pulmonary lesions (PPLs) in tuberculous endemic regions present a unique diagnostic challenge, as tuberculous PPL can mimic malignancy and potentially delay diagnosis for both conditions without a confirmatory investigation. While bronchoscopic biopsy using radial endobronchial ultrasound (rEBUS) guidance is becoming more common among pulmonologists, it is often performed with additional automation technology such as virtual bronchoscopic and electromagnetic navigation. This study aimed to evaluate the performance of rEBUS without such automation technology over a 6-year period in our institution. Methods: Retrospective chart review of all adult patients undergoing rEBUS-guided transbronchial biopsy for PPL in our institution over 6 years duration (October 2016 to December 2022). Results: A total of 551 PPLs were included with median target lesion size of 2.70 (interquartile range, 2.10-3.70) cm. In total, 84.2% of lesion demonstrated direct bronchus sign with 46.3% demonstrating concentric rEBUS orientation. The overall diagnostic yield was 78.8% [95% confidence interval (CI): 75.1-82.1%], with 1.1% rate of pneumothorax. Among the conclusive cases, 62.7% were malignant while 37.3% were tuberculous. Bronchus sign [adjusted odds ratio (adj. OR): 2.268] and concentric rEBUS orientation (adj. OR: 3.426) are independent predictors for conclusive procedure. The sensitivity of rEBUS for malignant and tuberculous disease was 85.27% (95% CI: 80.89-88.97%) and 71.77% (95% CI: 62.99-79.49%) respectively. A significant improving trend of diagnostic yield over time with reduction of median PPL size was observed with introduction of cryobiopsy and thin bronchoscopy into rEBUS service. Conclusions: rEBUS without automation technology remains relevant and useful in this era. rEBUS provides a rapid and safe diagnosis of PPL which may translate into better patient care.

9.
Respir Investig ; 61(4): 473-477, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37182371

RESUMO

Peripheral transbronchial needle aspiration (pTBNA) allows the access of pulmonary nodules without bronchus sign but is limited to cytological examination. A 39-year-old man with left parotid carcinoma presented with an incidental lung nodule. Target localisation was performed with manual airway mapping, virtual bronchoscopic navigation, and pTBNA. Direct target validation using radial endobronchial ultrasound (rEBUS) was performed through the puncture defect. Targeted pinpoint biopsy with a 1.1 mm cryoprobe through the pTBNA puncture defect confirmed metastatic adenoid cystic carcinoma. Guided pTBNA with rEBUS validation followed by cryobiopsy of lung nodules without bronchus sign is potentially feasible for histological and molecular analyses.


Assuntos
Broncoscopia , Neoplasias Pulmonares , Masculino , Humanos , Adulto , Brônquios/diagnóstico por imagem , Brônquios/patologia , Biópsia por Agulha Fina , Neoplasias Pulmonares/patologia , Pulmão/diagnóstico por imagem , Pulmão/patologia
11.
Respirol Case Rep ; 10(10): e01029, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36090018

RESUMO

Point-of-care ultrasound (POCUS) leads to efficient real-time diagnosis in a wide range of medical specialties. We describe the use of cardiac, lung and lower limb POCUS to rapidly diagnose massive pulmonary embolism and deep vein thrombosis in a 64-year-old patient presenting with acute dyspnea prior to elective bronchoscopy. Left femoral vein thrombus and features of increased right heart pressure on POCUS led to the decision to administer fibrinolytic therapy, with subsequent CT pulmonary angiogram confirming bilateral PE. The use of POCUS allowed for rapid imaging and interpretation leading to a rapid diagnosis of PE, thus fast-tracking lifesaving anticoagulation, especially in an outpatient setting.

12.
Clin Med (Lond) ; 21(1): e114-e115, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33479093

RESUMO

Percutaneous vertebroplasty (PV) involves injection of polymethylmethacrylate bone cement into vertebral body for relief of pain and strengthening of bone in symptomatic vertebral compression fractures.Passage of bone cement into vertebral venous plexus and then into the lungs is a rare and serious complication of PV. The reported incidence up to 26%.We present an incidental finding of pulmonary cement embolism (PCE) after PV. A 68-year-old woman with history of PV 3 years previously for T11 osteoporotic fracture presented to us with cough for 3 weeks following choking on a fish bone.Chest X-ray showed left lower zone consolidation and a high-density opacity in a tubular branching pattern, corresponding to pulmonary arterial distribution. Contrasted computed tomography of the thorax showed segmental pulmonary cement embolism of both lungs and left lower lobe consolidation.She underwent bronchoscopy with findings of a purulent secretion from the left lower lobe. Her symptoms resolved after 2 weeks of antibiotics. She was managed conservatively for the PCE as she remained asymptomatic.This case highlights the need for a standard post-PV chest X-ray, as patients with cement embolisms can be completely asymptomatic. Measures to minimise the risk of pulmonary cement embolisms during PV need to be taken.


Assuntos
Fraturas por Compressão , Fraturas por Osteoporose , Embolia Pulmonar , Fraturas da Coluna Vertebral , Vertebroplastia , Idoso , Cimentos Ósseos/efeitos adversos , Feminino , Humanos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/etiologia , Resultado do Tratamento
13.
Clin Respir J ; 15(6): 595-603, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33113256

RESUMO

BACKGROUND: Although radial endobronchial ultrasound (rEBUS) is an important verification tool in guided bronchoscopy, a navigational route was not provided. Manual airway mapping allows the bronchoscopist to translate the bronchial branching in computed tomography (CT) into a comparable bronchoscopic road map. We aimed to explore the feasibility of this technique in navigating conventional rEBUS bronchoscopy in the localisation of peripheral pulmonary lesion by determining navigation success and diagnostic yield. METHODS: Retrospective review of consecutive rEBUS bronchoscopy performed with a 6.2 mm conventional bronchoscope navigated via manual bronchial branch reading technique over 18 months. RESULTS: Ninety-eight target lesions were included. Median lesion size was 2.67 cm (IQR 2.22-3.38) with 96.9% demonstrating positive CT bronchus sign. Majority (86.7%) of lesions were situated in between the third and fifth airway generations. Procedure was performed with endotracheal intubation in 43.9% and fluoroscopy in 72.4%. 98.9% of lesions were successfully navigated and verified by rEBUS following the pre-planned airway road map. Bidirectional guiding device was employed in 29.6% of cases. Clinical diagnosis was secured in 88.8% of cases, majority of which were malignant disease. The discrepancy between navigation success and diagnostic yield was 10.1%. Target PPL located within five airway generations was associated with better diagnostic yield (95.1% vs. 58.8%, P < 0.001). There was 1 (1.0%) pneumothorax in our cohort. CONCLUSIONS: Manual bronchial branch reading technique in combination with conventional rEBUS is feasible in localisation of PPL, especially for lesions located within the first five airway generations.


Assuntos
Broncoscopia , Neoplasias Pulmonares , Brônquios , Endossonografia , Estudos de Viabilidade , Humanos , Leitura , Estudos Retrospectivos
14.
BMC Pulm Med ; 20(1): 158, 2020 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-32493437

RESUMO

BACKGROUND: Lung cancer is frequently situated peripherally in the upper lobes of the lung. Acquiring adequate tissue from this difficult-to-reach area remains a challenge. Transbronchial cryobiopsy (TBCB) has the ability to acquire larger specimens, but the rigidity of the standard 1.9 mm and 2.4 mm cryoprobes frequently poses challenges when used with a guide sheath (GS). The novel 1.1 mm cryoprobe, being both smaller and more flexible, may address this limitation. We describe the usage of this 1.1 mm flexible cryoprobe with GS in the biopsy of solitary pulmonary nodules (SPN) in the apical segment of the upper lobe in two cases. CASE REPORT: Both procedures were conducted with advanced airway under total intravenous anaesthesia. 2.6 mm GS was used in combination with a 2.2 mm rEBUS probe, using a therapeutic bronchoscope. Case 1 describes a SPN in the apical segment of the right upper lobe that was inconclusive by forceps biopsy due to GS displacement and inadequate biopsy depth. A steerable GS combined with the novel cryoprobe subsequently overcame this issue. Case 2 describes a SPN in the apical segment of the left upper lobe in which the standard cryoprobe failed to advance through the GS due to steep angulation. It also highlights with shorter activation time, the novel cryoprobe enable biopsied tissue to be retrieved through the GS while the bronchoscope-GS remains wedgend in the airway segment. There were no bleeding or pneumothorax complications in both cases, and histopathological examination confirmed adenocarcinoma of the lung. CONCLUSION: The 1.1 mm flexible cryoprobe in combination with GS and therapeutic bronchoscope offers an option to acquire adequate tissue in difficult-to-reach regions in the lung such as the apical segment of upper lobes. Further prospective series to evaluate its performance and safety in SPN biopsy is highly anticipated.


Assuntos
Broncoscopia/instrumentação , Criocirurgia/instrumentação , Neoplasias Pulmonares/patologia , Nódulo Pulmonar Solitário/patologia , Idoso , Biópsia/instrumentação , Feminino , Humanos , Instrumentos Cirúrgicos
15.
Respirol Case Rep ; 8(5): e00562, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32313656

RESUMO

Bronchopleural fistula (BPF) can complicate necrotizing pneumonia. Surgery would be indicated in patients who fail conservative management, yet this group is often of poor pulmonary function and general condition. Bronchial occlusion with endobronchial Watanabe spigots (EWS) can be a potential alternative treatment when the culprit bronchi can be isolated. In this case report, we describe a middle-aged gentleman who presented with necrotizing pneumonia complicated with pyopneumothorax with right upper lobe BPF, and who had failed to respond to chest drainage and antibiotics. EWS bronchial occlusion finally led to cessation of air leak, allowing removal of chest tube. EWS were removed uneventfully six months later. This case highlights the role of EWS in the management of BPF in patients with high surgical risk.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA