Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 129(13): 132701, 2022 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-36206440

RESUMO

The ^{13}C(α,n)^{16}O reaction is the main neutron source for the slow-neutron-capture process in asymptotic giant branch stars and for the intermediate process. Direct measurements at astrophysical energies in above-ground laboratories are hindered by the extremely small cross sections and vast cosmic-ray-induced background. We performed the first consistent direct measurement in the range of E_{c.m.}=0.24 to 1.9 MeV using the accelerators at the China Jinping Underground Laboratory and Sichuan University. Our measurement covers almost the entire intermediate process Gamow window in which the large uncertainty of the previous experiments has been reduced from 60% down to 15%, eliminates the large systematic uncertainty in the extrapolation arising from the inconsistency of existing datasets, and provides a more reliable reaction rate for the studies of the slow-neutron-capture and intermediate processes along with the first direct determination of the alpha strength for the near-threshold state.

2.
J Colloid Interface Sci ; 313(2): 630-7, 2007 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-17540394

RESUMO

The nonionic APG/n-butanol/cyclohexane/water microemulsions with different microstructure, which is induced by the variation of water contents, are investigated by the dielectric spectroscopy. An appropriate dielectric theory, Hanai theory and the corresponding analytical method are applied to obtain the internal properties of the constituent phases of microemulsions, such as the relative permittivity and conductivity of continuous and dispersed phases and the volume fraction of dispersed phase. Using these parameters, the distribution of n-butanol in constituent phases, which is of important in the study field of the microstructure of microemulsion, is obtained quantitatively. It is found that the n-butanol molecules not only distribute in the interfacial APG layer but also in the continuous and dispersed phases. In addition, the percolation threshold is interpreted by using the dynamic percolation model. The structural and dynamic information are obtained, for instance, the critical volume fraction of water when percolation occurs and the characteristic time for the rearrangement of clusters. These parameters are intimately related to the properties of microemulsions, especially the characteristics of the interfacial layer.

3.
Radiology ; 210(3): 605-10, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10207456

RESUMO

PURPOSE: To assess the usefulness of magnetic resonance (MR) cholangiopancreatography (MRCP) in the evaluation of disease in patients with acute or chronic pancreatitis. MATERIALS AND METHODS: MR imaging was performed at 1.5 T in 39 patients with chronic (n = 30) or acute (n = 9) pancreatitis. The patients underwent a pancreas MR imaging protocol that included an MRCP sequence. Comparison was made with findings at endoscopic retrograde cholangiopancreatography (ERCP), performed within 30 days. Three blinded readers used a scoring system to evaluate nine segments of the pancreatic and biliary ducts as depicted on the ERCP and MRCP images. MRCP image quality was also evaluated. RESULTS: Of 196 segments analyzed, 17 were not seen at MRCP (sensitivity, 91%). Of the segments visualized at MRCP, 14 were incorrectly characterized (accuracy, 92%). At MRCP, segments not detected or mischaracterized were either normal, slightly dilated, or narrowed. At ERCP, 42 segments in 19 patients were not visualized. MRCP findings were considered useful in all those cases. MRCP image quality was not interpretable in two cases due to artifacts. CONCLUSION: Very good correlation between ERCP and MRCP findings was demonstrated. Both modalities failed to depict pathologic conditions depicted by the alternative method. MRCP may obviate ERCP, particularly in patients who cannot undergo ERCP or in whom ERCP has been unsuccessful.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Imageamento por Ressonância Magnética , Pancreatite/diagnóstico , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Ductos Biliares/patologia , Doença Crônica , Constrição Patológica/diagnóstico , Constrição Patológica/diagnóstico por imagem , Dilatação Patológica/diagnóstico , Dilatação Patológica/diagnóstico por imagem , Feminino , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Ductos Pancreáticos/diagnóstico por imagem , Ductos Pancreáticos/patologia , Pancreatite/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Estudos Retrospectivos , Sensibilidade e Especificidade , Método Simples-Cego
4.
AJR Am J Roentgenol ; 162(5): 1063-6, 1994 May.
Artigo em Inglês | MEDLINE | ID: mdl-8165982

RESUMO

CT is the most sensitive radiologic method for the detection of differences in radiographic density in chest lesions. Areas of high attenuation (visually as opaque as bony structures) in an abnormality on CT scans can be an important clue to the correct diagnosis. The high attenuation is most often caused by calcification, but may also be due to iodine, barium, or radiopaque foreign bodies. This essay illustrates the patterns of high attenuation associated with chest diseases on unenhanced CT scans.


Assuntos
Calcinose/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Amiodarona/efeitos adversos , Meios de Contraste , Humanos , Fibrose Pulmonar/induzido quimicamente , Fibrose Pulmonar/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA