Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur Respir Rev ; 33(173)2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39293856

RESUMO

BACKGROUND: With recent advancements in bronchoscopic procedures, data on the best modality to sample peripheral pulmonary lesions (PPLs) is lacking, especially comparing bronchoscopy with computed tomography-guided transthoracic biopsy or needle aspiration (CT-TBNA). METHODS: We performed a meta-analysis, pairwise meta-analysis and network meta-analysis on studies reporting diagnostic yield and complications with the use of CT-TBNA, radial endobronchial ultrasound (rEBUS), virtual bronchoscopy (VB), electromagnetic navigation (EMN) or robot-assisted bronchoscopy (RAB) to sample PPLs. The primary outcome was diagnostic yield and the secondary outcome was complications. We estimated the relative risk ratios using a random-effects model and used the frequentist approach for the network meta-analysis. We performed extensive analysis to assess the heterogeneity including reporting bias, publication bias, subgroup and meta-regressional analysis. We assessed the quality of the studies using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) and QUADAS-Comparative (QUADAS-C). RESULTS: We included 363 studies. The overall pooled diagnostic yield was 78.1%, the highest with CT-TBNA (88.9%), followed by RAB (84.8%) and the least with rEBUS (72%). In the pairwise meta-analysis, only rEBUS showed inferiority to CT-TBNA. The network meta-analysis ranked CT-TBNA as likely the most effective approach followed by VB, EMN and RAB, while rEBUS was the least effective, with a low-GRADE certainty. CT-TBNA had the highest rate of complications. CONCLUSION: Although CT-TBNA is the most effective approach to sample PPLs, RAB has a comparable diagnostic yield with a lesser complication rate. Further prospective studies are needed comparing CT-TBNA and RAB.


Assuntos
Broncoscopia , Metanálise em Rede , Valor Preditivo dos Testes , Humanos , Broncoscopia/efeitos adversos , Reprodutibilidade dos Testes , Pneumopatias/diagnóstico , Pneumopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Fatores de Risco , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso
2.
J Thorac Dis ; 16(8): 5422-5434, 2024 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-39268090

RESUMO

Background and Objective: Robotic-assisted bronchoscopy (RAB) has emerged as an advanced technology for lung cancer diagnosis. This review explores the three approved robotic bronchoscopy systems: Ion™ Endoluminal (Intuitive Surgical, Sunnyvale, CA, USA), Monarch™ (Johnson & Johnson, Redwood City, CA, USA), and Galaxy System™ (Noah Medical, San Carlos, CA, USA), and their different operational systems. This narrative review aims to summarize their findings and outcomes for sampling peripheral pulmonary lesions (PPL) suspected of lung cancer. Methods: A search in PubMed and Google Scholar databases was conducted for articles and abstracts published between January 2018 to May 2024 using the terms "robotic bronchoscopy" or "robotic-assisted bronchoscopy" for biopsy of PPL. Key Content and Findings: Lung cancer is the leading cause of cancer-related mortality. The introduction of RAB aims to improve the feasibility and safety of sampling PPL. Current literature describes high diagnostic yields with low risk of complications, allowing concurrent hilar and mediastinal staging within the same procedure. RAB can potentially improve early diagnosis and treatment of pulmonary malignancies and survival rate in long term, while progressing towards therapeutic applications in the near future. Conclusions: As RAB evolves, its potential as a "one-stop shop" for diagnosis, staging, and treatment can positively impact lung cancer detection, focusing on improved patient-centered outcomes and reducing multiple diagnostic and therapeutic procedures.

3.
Cureus ; 16(4): e57414, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38694634

RESUMO

Purpose The increasing use of computed tomography (CT) imaging has led to the detection of more ground-glass nodules (GGNs) and subsolid nodules (SSNs), which may be malignant and require a biopsy for proper diagnosis. Approximately 75% of persistent GGNs can be attributed to adenocarcinoma in situ or minimally invasive adenocarcinoma. A CT-guided biopsy has been proven to be a reliable procedure with high diagnostic performance. However, the diagnostic accuracy and safety of a CT-guided biopsy for GGNs and SSNs with solid components ≤6 mm are still uncertain. The aim of this study is to assess the diagnostic accuracy of a CT-guided core needle biopsy (CNB) for GGN and SSNs with solid components ≤6 mm. Methods This is a retrospective study of patients who underwent CT-guided CNB for the evaluation of GGNs and SSNs with solid components ≤6 mm between February 2020 and January 2023. Biopsy findings were compared to the final diagnosis determined by definite histopathologic examination and clinical course. Results A total of 22 patients were enrolled, with a median age of 74 years (IQR: 68-81). A total of 22 nodules were assessed, comprising 15 (68.2%) SSNs with a solid component measuring ≤6 mm and seven (31.8%) pure GGNs. The histopathological examination revealed that 12 (54.5%) were diagnosed as malignant, nine (40.9%) as benign, and one (4.5%) as non-diagnostic. The overall diagnostic accuracy and sensitivity for malignancy were 86.36% and 85.7%, respectively. Conclusion A CT-guided CNB for GGNs and SSNs with solid components measuring ≤6 mm appears to have a high diagnostic accuracy.

4.
BMJ Case Rep ; 17(4)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38670566

RESUMO

A woman in her late 60s with severe chronic obstructive pulmonary disease (COPD) and emphysema underwent bronchoscopic lung volume reduction (BLVR) with endobronchial valves (EBV) to address hyperinflation. The initial EBV placement has led to partial lobar atelectasis of the left lower lobe and resulted in significant improvement in the patient's symptoms and lung function. However, valve migration occurred later due to pneumothorax unrelated to valves, leading to suboptimal clinical improvement. The patient achieved delayed full lobar atelectasis 21 months after EBV placement, which led to a significant clinical improvement. The patient decided to be delisted from the lung transplant list due to the improvement. This case highlights the importance of considering delayed atelectasis as a possible outcome of EBV placement and suggests the need for further exploration of the long-term implications and associations of this procedure.


Assuntos
Broncoscopia , Pneumonectomia , Atelectasia Pulmonar , Doença Pulmonar Obstrutiva Crônica , Humanos , Atelectasia Pulmonar/etiologia , Atelectasia Pulmonar/diagnóstico por imagem , Feminino , Broncoscopia/métodos , Pneumonectomia/métodos , Doença Pulmonar Obstrutiva Crônica/cirurgia , Doença Pulmonar Obstrutiva Crônica/complicações , Enfisema Pulmonar/cirurgia , Enfisema Pulmonar/diagnóstico por imagem , Pessoa de Meia-Idade , Próteses e Implantes , Resultado do Tratamento
5.
Respiration ; 103(5): 280-288, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38471496

RESUMO

INTRODUCTION: Lung cancer remains the leading cause of cancer death worldwide. Subsolid nodules (SSN), including ground-glass nodules (GGNs) and part-solid nodules (PSNs), are slow-growing but have a higher risk for malignancy. Therefore, timely diagnosis is imperative. Shape-sensing robotic-assisted bronchoscopy (ssRAB) has emerged as reliable diagnostic procedure, but data on SSN and how ssRAB compares to other diagnostic interventions such as CT-guided transthoracic biopsy (CTTB) are scarce. In this study, we compared diagnostic yield of ssRAB versus CTTB for evaluating SSN. METHODS: A retrospective study of consecutive patients who underwent either ssRAB or CTTB for evaluating GGN and PSN with a solid component less than 6 mm from February 2020 to April 2023 at Mayo Clinic Florida and Rochester. Clinicodemographic information, nodule characteristics, diagnostic yield, and complications were compared between ssRAB and CTTB. RESULTS: A total of 66 nodules from 65 patients were evaluated: 37 PSN and 29 GGN. Median size of PSN solid component was 5 mm (IQR: 4.5, 6). Patients were divided into two groups: 27 in the ssRAB group and 38 in the CTTB group. Diagnostic yield was 85.7% for ssRAB and 89.5% for CTTB (p = 0.646). Sensitivity for malignancy was similar between ssRAB and CTTB (86.4% vs. 88.5%; p = 0.828), with no statistical difference. Complications were more frequent in CTTB with no significant difference (8 vs. 2; p = 0.135). CONCLUSION: Diagnostic yield for SSN was similarly high for ssRAB and CTTB, with ssRAB presenting less complications and allowing mediastinal staging within the same procedure.


Assuntos
Broncoscopia , Biópsia Guiada por Imagem , Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Procedimentos Cirúrgicos Robóticos , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Broncoscopia/métodos , Idoso , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/diagnóstico por imagem , Biópsia Guiada por Imagem/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Nódulos Pulmonares Múltiplos/patologia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico , Nódulo Pulmonar Solitário/patologia , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico
6.
Respiration ; 102(10): 899-904, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37619549

RESUMO

BACKGROUND: Ground-glass pulmonary nodules (GGNs) are most commonly sampled by percutaneous transthoracic biopsy. Diagnostic yield for ground-glass nodules using robotic-assisted bronchoscopy has been scarcely described, with a reported yield of 70.6%. OBJECTIVES: The aim of this study is to assess diagnostic yield for GGNs using shape-sensing robotic-assisted bronchoscopy (ssRAB). METHOD: A retrospective study of patients who underwent ssRAB for evaluation of GGNs, from September 2021 to April 2023. Primary outcome was diagnostic yield of ssRAB for GGNs, secondary outcomes were sensitivity for malignancy, and complications that required admission or intervention. RESULTS: A total of 23 nodules were biopsied from 22 patients. Median age was 71 years (IQR 66-81), 63.6% were female, and 40.9% had a previous history of cancer. Forty-three percent of nodules were in the right upper lobes, and the median lesion size was 1.8 × 1.21. Twelve were subsolid nodules (SSNs), and 11 were pure GGNs. Overall diagnostic yield was 87%, with a sensitivity for malignancy of 88.9%. Adenocarcinoma was the most common malignancy diagnosed (70%). No procedure-related complications were reported. CONCLUSION: The use of ssRAB shows a high diagnostic yield for diagnosing GGN and SSN with less than 6 mm solid component with a low risk for complications.


Assuntos
Neoplasias Pulmonares , Procedimentos Cirúrgicos Robóticos , Nódulo Pulmonar Solitário , Humanos , Feminino , Idoso , Masculino , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Broncoscopia , Tomografia Computadorizada por Raios X , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/patologia
7.
Respirol Case Rep ; 11(7): e01176, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37303308

RESUMO

Lung cancer is the deadliest cancer worldwide, therefore, early and prompt diagnosis is essential for better patient outcomes. It is known to have a high predilection for metastasis to the adrenal glands; however, two-thirds of adrenal masses in patients with lung cancer will turn out to be benign, so timely detection is crucial. We present a case of a lung squamous cell carcinoma diagnosed by shape-sensing robotic-assisted bronchoscopy (ssRAB), negative mediastinal and hilar staging with endobronchial ultrasound (EBUS) and transbronchial needle aspiration (TBNA), and a pheochromocytoma diagnosed through endoscopic ultrasound with bronchoscope (EUS-B) fine needle aspiration (FNA) all in the same endoscopic procedure.

8.
Respiration ; 102(6): 449-453, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37105143

RESUMO

Bronchoscopic biopsy of peripheral pulmonary nodules has evolved in recent years with the emergence of new technologies such as shape-sensing robotic-assisted bronchoscopy. The use of three-dimensional (3D) fluoroscopy for intraoperative visualization of the biopsy tool in relation to the target nodule aims to overcome computed tomography-to-body divergence encountered during the procedure and allows for more accurate sampling to improve adequacy and diagnostic performance. Until recently, the robotic-assisted navigation plan and 3D imaging function as separate systems. We present a case where intraoperative 3D fluoroscopy images were integrated to the robotic bronchoscopy navigation system, resulting in a single, dynamic, real-time 3D virtual plan showing readjusted paths toward the lesion displayed in the robotic bronchoscopy navigation system, allowing in this case, biopsying two bilateral pulmonary nodules, resulting in different diagnosis within the same endoscopic procedure.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Procedimentos Cirúrgicos Robóticos , Humanos , Broncoscopia/métodos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/cirurgia , Tomografia Computadorizada por Raios X , Fluoroscopia/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA