Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 937
Filtrar
1.
Int J Tuberc Lung Dis ; 28(2): 73-80, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38303039

RESUMO

BACKGROUND: The importance of early intravenous (IV) antibiotic use for Mycobacterium abscessus complex lung diseases (MABC-LD) treatment remains unknown. METHODS: A retrospective multi-centre observational study was conducted in Taiwan. Patients who were diagnosed with and received treatment for MABC-LD from January 2007 to April 2021 were included. Treatment outcome was defined as modified microbiological cure of MABC-LD.RESULTS: Of the 89 enrolled patients, 34 (38.2%) received IV antibiotics as part of the treatment regimen. The median time to IV initiation was 1 day (IQR 1???49); 24 (70.6%) of these patients received IV agents within 4 weeks, defined as early-use. Forty-two (47.2%) patients achieved modified microbiological cure. In the multivariable logistic analysis, early IV antibiotic use was an independent factor associated with modified microbiological cure (aOR 5.32, 95% CI 1.66???17.00), whereas high radiological score (aOR 0.86, 95% CI 0.73???1.00) demonstrated negative association.CONCLUSIONS: In the present study, early use of effective IV antibiotic was prescribed in a low percentage (27%) for MABC-LD. By contrast, early IV antibiotic use was correlated with higher microbiological cure than were late or non-use. Future larger and prospective studies are needed to validate the association.


Assuntos
Pneumopatias , Infecções por Mycobacterium não Tuberculosas , Mycobacterium abscessus , Humanos , Antibacterianos/uso terapêutico , Infecções por Mycobacterium não Tuberculosas/tratamento farmacológico , Infecções por Mycobacterium não Tuberculosas/microbiologia , Pneumopatias/tratamento farmacológico , Pneumopatias/microbiologia , Estudos Prospectivos , Estudos Retrospectivos
2.
Opt Lett ; 48(15): 3877-3880, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37527072

RESUMO

An LED-side-pumped Nd:YAG/Cr4+:YAG passively Q-switched (PQS) laser containing an extracavity optical parametric oscillator (EOPO) is demonstrated. As far as we know, it is the first LED-pumped eye-safe laser. The Nd:YAG pump module is optimized to increase the PQS pulse energy to 24 mJ at 1064 nm. By using a single-pass EOPO design, the output energy of the signal pulse at 1573 nm is 7.44 mJ with a pulse width of 16 ns, the peak power is 434 kW, and the pump-to-signal conversion efficiency is 31%. For double-pass EOPO operation, the pump-to-signal conversion efficiency increases to 45.8%, the output energy of signal pulse is up to 10.98 mJ with a pulse width of 23.5 ns, and the peak power is 459 kW.

3.
Eur J Radiol ; 155: 110466, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35986988

RESUMO

PURPOSE: To prospectively assess the rate of clot resolution from CT pulmonary angiography (CTPA) in patients with acute pulmonary embolism (PE). MATERIALS AND METHODS: This prospective cohort study included 290 patients (136 men, 154 women; mean age, 51.9 years) with acute PE. All patients had a CTPA at the presentation and had at least one follow-up within 6 months (mean 72.7 days). Sixty-four percent of patients had follow-up scans for research purposes within a pre-determined period (between 28 and 184 days; mean, 78.27 days) and 36 % had (between 2 and 184 days; mean, 62.78 days) for a clinical indication. The volume of each clot was measured using a semi-automated quantification program. The resolution rate was evaluated by interval-censored analysis. RESULTS: The overall estimated probability of complete resolution was 42 % at 7 days, 56 % at 10 days, and 71 % at 45 days. Achieving complete resolution was significantly faster in patients with peripheral clots (HR: 1.78; CI: 1.05-3.03, p = 0.032) but slower in patients with consolidation and history of venous thromboembolism (VTE), (HR: 0.37; CI: 0.18-0.79, p = 0.01 and HR: 0.57; CI: 0.35-0.91, p = 0.019, respectively). Although the patients with cancer showed a faster resolution rate (HR: 1.67; CI: 1.05-2.68, p = 0.032), the mortality rate was significantly higher than non-cancer patients. CONCLUSION: The resolution rate of clot burden in acute PE was associated with patients' clinical presentation variables and CTPA imaging biomarkers. This information may be incorporated into designing a prediction rule and determining the appropriate duration of anticoagulation therapy in patients with acute PE.


Assuntos
Embolia Pulmonar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Aguda , Angiografia/métodos , Anticoagulantes/uso terapêutico , Biomarcadores , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Embolia Pulmonar/diagnóstico por imagem
4.
Rev Sci Instrum ; 93(6): 063105, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35778029

RESUMO

A hyperspectral imaging system (HIS) is a helpful tool that acquires spatial and spectral information from a target. This study developed a coaxial heterogeneous HIS (CHHIS) to collect spectral images with wavelengths ranging from 400 to 1700 nm. In this system, a visible (VIS) spectrometer and a short-wave infrared (SWIR) spectrometer are combined with a coaxial optical path to share the same field of view. This structure reduces the complexity of spatial registration and maintains the scanning duration of two spectrometers as that of a single spectrometer. The spectrometers are also replaceable for extending the detecting spectral range of the system. The calibration methodologies, including spatial correction, spectral calibration, and reflectance calibration, were developed for this system. The signal-to-noise ratio of VIS and SWIR spectrometers in the CHHIS was up to 40 and 60 dB when the exposure time of the VIS and SWIR imaging sensors was 1000 and 10 ms, respectively. When the target distance was at 600 mm, the spatial error of VIS and SWIR images in the scanning direction was less than 1 pixel; these results proved that the system was stable.


Assuntos
Diagnóstico por Imagem , Imageamento Hiperespectral , Calibragem
5.
J Appl Crystallogr ; 55(Pt 2): 340-352, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35497659

RESUMO

Recent developments in the instrumentation and data analysis of synchrotron small-angle X-ray scattering (SAXS) on biomolecules in solution have made biological SAXS (BioSAXS) a mature and popular tool in structural biology. This article reports on an advanced endstation developed at beamline 13A of the 3.0 GeV Taiwan Photon Source for biological small- and wide-angle X-ray scattering (SAXS-WAXS or SWAXS). The endstation features an in-vacuum SWAXS detection system comprising two mobile area detectors (Eiger X 9M/1M) and an online size-exclusion chromatography system incorporating several optical probes including a UV-Vis absorption spectrometer and refractometer. The instrumentation and automation allow simultaneous SAXS-WAXS data collection and data reduction for high-throughput biomolecular conformation and composition determinations. The performance of the endstation is illustrated with the SWAXS data collected for several model proteins in solution, covering a scattering vector magnitude q across three orders of magnitude. The crystal-model fittings to the data in the q range ∼0.005-2.0 Å-1 indicate high similarity of the solution structures of the proteins to their crystalline forms, except for some subtle hydration-dependent local details. These results open up new horizons of SWAXS in studying correlated local and global structures of biomolecules in solution.

8.
J Synchrotron Radiat ; 28(Pt 6): 1954-1965, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34738951

RESUMO

The optical design and performance of the recently opened 13A biological small-angle X-ray scattering (SAXS) beamline at the 3.0 GeV Taiwan Photon Source of the National Synchrotron Radiation Research Center are reported. The beamline is designed for studies of biological structures and kinetics in a wide range of length and time scales, from angstrom to micrometre and from microsecond to minutes. A 4 m IU24 undulator of the beamline provides high-flux X-rays in the energy range 4.0-23.0 keV. MoB4C double-multilayer and Si(111) double-crystal monochromators (DMM/DCM) are combined on the same rotating platform for a smooth rotation transition from a high-flux beam of ∼4 × 1014 photons s-1 to a high-energy-resolution beam of ΔE/E ≃ 1.5 × 10-4; both modes share a constant beam exit. With a set of Kirkpatrick-Baez (KB) mirrors, the X-ray beam is focused to the farthest SAXS detector position, 52 m from the source. A downstream four-bounce crystal collimator, comprising two sets of Si(311) double crystals arranged in a dispersive configuration, optionally collimate the DCM (vertically diffracted) beam in the horizontal direction for ultra-SAXS with a minimum scattering vector q down to 0.0004 Å-1, which allows resolving ordered d-spacing up to 1 µm. A microbeam, of 10-50 µm beam size, is tailored by a combined set of high-heat-load slits followed by micrometre-precision slits situated at the front-end 15.5 m position. The second set of KB mirrors then focus the beam to the 40 m sample position, with a demagnification ratio of ∼1.5. A detecting system comprising two in-vacuum X-ray pixel detectors is installed to perform synchronized small- and wide-angle X-ray scattering data collections. The observed beamline performance proves the feasibility of having compound features of high flux, microbeam and ultra-SAXS in one beamline.


Assuntos
Fótons , Síncrotrons , Espalhamento a Baixo Ângulo , Taiwan , Difração de Raios X , Raios X
9.
J Dent Res ; 100(10): 1109-1117, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34334009

RESUMO

To establish an ideal microenvironment for regenerating maxillofacial defects, recent research interests have concentrated on developing scaffolds with intricate configurations and manipulating the stiffness of extracellular matrix toward osteogenesis. Herein, we propose to infuse a degradable RGD-functionalized alginate matrix (RAM) with osteoid-like stiffness, as an artificial extracellular matrix, to a rigid 3D-printed hydroxyapatite scaffold for maxillofacial regeneration. The 3D-printed hydroxyapatite scaffold was produced by microextrusion technology and showed good dimensional stability with consistent microporous detail. RAM was crosslinked by calcium sulfate to manipulate the stiffness, and its degradation was accelerated by partial oxidation using sodium periodate. The results revealed that viability of bone marrow stem cells was significantly improved on the RAM and was promoted on the oxidized RAM. In addition, the migration and osteogenic differentiation of bone marrow stem cells were promoted on the RAM with osteoid-like stiffness, specifically on the oxidized RAM. The in vivo evidence revealed that nonoxidized RAM with osteoid-like stiffness upregulated osteogenic genes but prevented ingrowth of newly formed bone, leading to limited regeneration. Oxidized RAM with osteoid-like stiffness facilitated collagen synthesis, angiogenesis, and osteogenesis and induced robust bone formation, thereby significantly promoting maxillofacial regeneration. Overall, this study supported that in the stabilized microenvironment, oxidized RAM with osteoid-like stiffness offered requisite mechanical cues for osteogenesis and an appropriate degradation profile to facilitate bone formation. Combining the 3D-printed hydroxyapatite scaffold and oxidized RAM with osteoid-like stiffness may be an advantageous approach for maxillofacial regeneration.


Assuntos
Osteogênese , Alicerces Teciduais , Regeneração Óssea , Diferenciação Celular , Oligopeptídeos , Impressão Tridimensional
10.
J Synchrotron Radiat ; 28(Pt 3): 977-986, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33950006

RESUMO

We report on the development of a high-resolution and highly efficient beamline for soft X-ray resonant inelastic X-ray scattering (RIXS) located at the Taiwan Photon Source. This beamline adopts an optical design that uses an active grating monochromator (AGM) and an active grating spectrometer (AGS) to implement the energy compensation principle of grating dispersion. Active gratings are utilized to diminish defocus, coma and higher-order aberrations, as well as to decrease the slope errors caused by thermal deformation and optical polishing. The AGS is mounted on a rotatable granite platform to enable momentum-resolved RIXS measurements with scattering angles over a wide range. Several high-precision instruments developed in-house for this beamline are described briefly. The best energy resolution obtained from this AGM-AGS beamline was 12.4 meV at 530 eV, achieving a resolving power of 4.2 × 104, while the bandwidth of the incident soft X-rays was kept at 0.5 eV. To demonstrate the scientific impact of high-resolution RIXS, we present an example of momentum-resolved RIXS measurements on a high-temperature superconducting cuprate, i.e. La2-xSrxCuO4. The measurements reveal the A1g buckling phonons in superconducting cuprates, opening a new opportunity to investigate the coupling between these phonons and charge-density waves.

11.
Science ; 371(6525)2021 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-33414190

RESUMO

Phillips et al (Reports, 25 October 2019, p. 480) incorrectly conclude that tropical earthworm communities are less diverse and abundant than temperate communities. This result is an artifact generated by some low-quality datasets, lower sampling intensity in the tropics, different patterns in richness-area relationships, the occurrence of invasive species in managed soils, and a focus on local rather than regional richness.


Assuntos
Oligoquetos , Animais , Solo
15.
Bone Joint Res ; 8(4): 179-188, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31069072

RESUMO

OBJECTIVES: Prosthetic joint infection (PJI) diagnosis is a major challenge in orthopaedics, and no reliable parameters have been established for accurate, preoperative predictions in the differential diagnosis of aseptic loosening or PJI. This study surveyed factors in synovial fluid (SF) for improving PJI diagnosis. METHODS: We enrolled 48 patients (including 39 PJI and nine aseptic loosening cases) who required knee/hip revision surgery between January 2016 and December 2017. The PJI diagnosis was established according to the Musculoskeletal Infection Society (MSIS) criteria. SF was used to survey factors by protein array and enzyme-linked immunosorbent assay to compare protein expression patterns in SF among three groups (aseptic loosening and first- and second-stage surgery). We compared routine clinical test data, such as C-reactive protein level and leucocyte number, with potential biomarker data to assess the diagnostic ability for PJI within the same patient groups. RESULTS: Cut-off values of 1473 pg/ml, 359 pg/ml, and 8.45 pg/ml were established for interleukin (IL)-16, IL-18, and cysteine-rich with EGF-like domains 2 (CRELD2), respectively. Receiver operating characteristic curve analysis showed that these factors exhibited an accuracy of 1 as predictors of PJI. These factors represent potential biomarkers for decisions associated with prosthesis reimplantation based on their ability to return to baseline values following the completion of debridement. CONCLUSION: IL-16, IL-18, and CRELD2 were found to be potential biomarkers for PJI diagnosis, with SF tests outperforming blood tests in accuracy. These factors could be useful for assessing successful debridement based on their ability to return to baseline values following the completion of debridement.Cite this article: M-F. Chen, C-H. Chang, L-Y. Yang, P-H. Hsieh, H-N. Shih, S. W. N. Ueng, Y. Chang. Synovial fluid interleukin-16, interleukin-18, and CRELD2 as novel biomarkers of prosthetic joint infections. Bone Joint Res 2019;8:179-188. DOI: 10.1302/2046-3758.84.BJR-2018-0291.R1.

16.
J Pharmacol Exp Ther ; 368(3): 514-523, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30606762

RESUMO

Thiazolidinediones (TZDs) are peroxisome proliferator-activated receptor γ (PPARγ) agonists that represent an effective class of insulin-sensitizing agents; however, clinical use is associated with weight gain and peripheral edema. To elucidate the role of PPARγ expression in endothelial cells (ECs) in these side effects, EC-targeted PPARγ knockout (Pparg ΔEC) mice were placed on a high-fat diet to promote PPARγ agonist-induced plasma volume expansion, and then treated with the TZD rosiglitazone. Compared with Pparg-floxed wild-type control (Pparg f/f) mice, Pparg ΔEC treated with rosiglitazone are resistant to an increase in extracellular fluid, water content in epididymal and inguinal white adipose tissue, and plasma volume expansion. Interestingly, histologic assessment confirmed significant rosiglitazone-mediated capillary dilation within white adipose tissue of Pparg f/f mice, but not Pparg ΔEC mice. Analysis of ECs isolated from untreated mice in both strains suggested the involvement of changes in endothelial junction formation. Specifically, compared with cells from Pparg f/f mice, Pparg ΔEC cells had a 15-fold increase in focal adhesion kinase, critically important in EC focal adhesions, and >3-fold significant increase in vascular endothelial cadherin, the main component of focal adhesions. Together, these results indicate that rosiglitazone has direct effects on the endothelium via PPARγ activation and point toward a critical role for PPARγ in ECs during rosiglitazone-mediated plasma volume expansion.


Assuntos
Tecido Adiposo/metabolismo , Células Endoteliais/metabolismo , Hipoglicemiantes/farmacologia , PPAR gama/deficiência , Rosiglitazona/farmacologia , Remodelação Vascular/fisiologia , Tecido Adiposo/irrigação sanguínea , Tecido Adiposo/efeitos dos fármacos , Animais , Células Endoteliais/efeitos dos fármacos , Deleção de Genes , Masculino , Camundongos , Camundongos Transgênicos , PPAR gama/genética , Volume Plasmático/efeitos dos fármacos , Volume Plasmático/fisiologia , Remodelação Vascular/efeitos dos fármacos
17.
Transplant Proc ; 50(9): 2645-2647, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30401367

RESUMO

BACKGROUND: To evaluate the effect of dextrose contained in banked blood products on the changes of blood glucose levels in adult living donor liver transplantation patients retrospectively. METHODS: Four hundred seventy-seven patients were divided into a non-blood transfusion (BT) group (G1) and a BT group (G2). The changes in blood glucose levels during the operation were compared using a Mann-Whitney U test, and a P value less than .05 was regarded as significant. RESULTS: No significant changes were detected in blood glucose levels after anesthesia, during dissection phase, in the anhepatic phase, or after reperfusion between the groups. Estimated blood loss for G1 (n = 89) and G2 (n = 388) were 718 ± 514 and 5804 ± 877 mL respectively, G1 had no blood transfusion but G2 had received 4350 ± 6230 mL leukocyte-poor red blood cell transfusion, the pre- and end operation hemoglobin for G1 and G2 were 13.2 ± 2.0, 10.2 ± 1.9 and 10.1 ± 1.6, 10.2 ± 1.9 mg/dL respectively, indicating that they were not under or over transfused. CONCLUSION: When banked blood products are used to replace ongoing blood loss, the dextrose contained in citrate-phosphate-dextrose-adenine seems to have no effect on the changes in the blood glucose levels of the recipients.


Assuntos
Glicemia/análise , Transfusão de Sangue/estatística & dados numéricos , Hemostasia Cirúrgica/métodos , Transplante de Fígado/métodos , Adulto , Bancos de Sangue , Citratos/sangue , Feminino , Glucose , Humanos , Doadores Vivos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Estatísticas não Paramétricas
18.
Mol Phylogenet Evol ; 124: 60-70, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29501375

RESUMO

Pontoscolex corethrurus is the most widespread earthworm species in tropical and sub-tropical zones and one of the most studied in soil science. Although, ecological interactions of P. corethrurus with its environment are well documented, the taxonomic status of the species remains unclear. In this study, we investigated phylogenetic relationships within the genus Pontoscolex, in particular focusing on morphologically indistinguishable (i.e., cryptic) lineages. A total of 792 specimens collected from 25 different countries and islands all over the world were analyzed using two mitochondrial (COI and 16S rDNA) and two nuclear (internal transcribed spacers 2 and 28S rDNA) markers, and a total of 11 morphological characters both internal and external were investigated in all genetically characterized lineages. A large-scale multilocus sequence data matrix was also obtained for Pontoscolex spp. specimens using the Anchored Hybrid Enrichment (AHE) method. Multilocus phylogenetic and phylogenomic analyses, combined with species delimitation methods; including single locus (mPTP, ABGD) and multilocus (BPP) approaches, revealed congruent results. Four cryptic species were supported within the P. corethrurus species complex, and four potentially new species within the genus Pontoscolex. One widespread lineage (L1), within P. corethrurus complex was observed in the current population of Fritz Müller's garden where P. corethrurus was first described in 1856. Cryptic lineages were observed in sympatry at several localities. This, in combination with observed heteroplasmy in COI gene in one population raises an important question of reproductive isolation between these species.


Assuntos
Oligoquetos/classificação , Animais , Teorema de Bayes , Marcadores Genéticos , Geografia , Haplótipos/genética , Oligoquetos/anatomia & histologia , Filogenia , Especificidade da Espécie , Simpatria
19.
Environ Pollut ; 236: 71-81, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29414376

RESUMO

Due to their systemic character and high efficacy to insect controls, neonicotinoid insecticides (neonics) have been widely used in global agriculture since its introduction in early 1990. Recent studies have indicated that neonics may be ubiquitous, have longer biological half-lives in the environment once applied, and therefore implicitly suggested the increasing probability for human exposure to neonics. Despite of neonics' persistent characters and widespread uses, scientific literature in regard of pathways in which human exposure could occur is relatively meager. In this review, we summarized results from peer-reviewed articles published prior to 2017 that address potential human exposures through ingestion and inhalation, as well as results from human biomonitoring studies. In addition, we proposed the use of relative potency factor approach in order to facilitate the assessment of concurrent exposure to a mixture of neonics with similar chemical structures and toxicological endpoints. We believe that the scientific information that we presented in this review will aid to future assessment of total neonic exposure and subsequently human health risk characterization.


Assuntos
Exposição Ambiental/efeitos adversos , Inseticidas/toxicidade , Neonicotinoides/toxicidade , Agricultura , Monitoramento Ambiental , Humanos , Inseticidas/química , Neonicotinoides/química
20.
J Child Orthop ; 12(6): 629-634, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30607211

RESUMO

PURPOSE: Little data is available on the efficiency of different implants for epiphysiodesis. The purpose of this study is to compare the efficacy between plates and staples in decreasing leg-length discrepancy. METHODS: A retrospective review of 19 children who underwent temporary epiphysiodesis of the legs was conducted, with a minimum of two years of follow-up. The bone length and length ratio to the short side were measured at six months, one year and two years postoperatively. The change in discrepancy was compared between staples and plates by an independent t-test, and the shortest time to a significant decrease in discrepancy was determined using a paired t-test. RESULTS: Ten patients underwent 13 staple procedures in nine femurs and four tibias for a 2.8-cm discrepancy at age 11.8 years, and nine patients underwent 14 plate procedures in seven femurs and seven tibias for a 3.1-cm discrepancy at age 12.4 years. Patients were followed up to skeletal maturity, except two. The use of staples decreased the discrepancy in the bone ratio from +4.8% to +1.2% in two years, and the use of plates decreased this ratio from +5.1% to +3.3% in two years. The change in the length ratio was significantly greater after stapling. Six months were required after stapling before the first significant decrease in discrepancy; it took two years after plating. CONCLUSIONS: This study showed a significantly lower efficacy for decreasing leg-length discrepancy by tension band plating. Orthopaedic surgeons should be aware of the limitations of using plates for suppressing bone growth. LEVEL OF EVIDENCE: III.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA