Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 19(16)2019 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-31434228

RESUMO

In order to cut down influence on the uncertainty disturbances of a linear motion single axis robot machine, such as the external load force, the cogging force, the column friction force, the Stribeck force, and the parameters variations, the micrometer backstepping control system, using an amended recurrent Gottlieb polynomials neural network and altered ant colony optimization (AACO) with the compensated controller, is put forward for a linear motion single axis robot machine drive system mounted on the linear-optical ruler with 1 um resolution. To achieve high-precision control performance, an adaptive law of the amended recurrent Gottlieb polynomials neural network based on the Lyapunov function is proposed to estimate the lumped uncertainty. Besides this, a novel error-estimated law of the compensated controller is also proposed to compensate for the estimated error between the lumped uncertainty and the amended recurrent Gottlieb polynomials neural network with the adaptive law. Meanwhile, the AACO is used to regulate two variable learning rates in the weights of the amended recurrent Gottlieb polynomials neural network to speed up the convergent speed. The main contributions of this paper are: (1) The digital signal processor (DSP)-based current-regulation pulse width modulation (PWM) control scheme being successfully applied to control the linear motion single axis robot machine drive system; (2) the micrometer backstepping control system using an amended recurrent Gottlieb polynomials neural network with the compensated controller being successfully derived according to the Lyapunov function to diminish the lumped uncertainty effect; (3) achieving high-precision control performance, where an adaptive law of the amended recurrent Gottlieb polynomials neural network based on the Lyapunov function is successfully applied to estimate the lumped uncertainty; (4) a novel error-estimated law of the compensated controller being successfully used to compensate for the estimated error; and (5) the AACO being successfully used to regulate two variable learning rates in the weights of the amended recurrent Gottlieb polynomials neural network to speed up the convergent speed. Finally, the effectiveness of the proposed control scheme is also verified by the experimental results.

2.
Ultrasonics ; 48(2): 91-7, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18221977

RESUMO

This paper investigates design, fabrication and test of thin disc piezoelectric transformers (PTs) based on piezoelectric buzzers with gap circles at different diameters of the gap circles. The performance test is focused on characteristics of voltage gains, including maximum voltage gains and maximum-gain frequencies, for each piezoelectric transformer under different load conditions. Both a piezoelectric buzzer and a gap circle on a silver electrode of the buzzer are needed to build any type of the PTs. Here, the gap circle is used to form a ring-shaped input electrode and a circle-shaped output electrode for each piezoelectric transformer. To do so, both structure and connection of a PT are first expressed. Then, operating principle of a PT and its related vibration mode observed by a carbon-power imaging technique are described. Moreover, an experimental setup for characterizing each piezoelectric transformer is constructed. Finally, effects of diameters of the gap circles on characteristics of voltage gains at different load resistances are discussed.


Assuntos
Desenho Assistido por Computador , Eletrônica/instrumentação , Transferência de Energia , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Vibração
3.
Artigo em Inglês | MEDLINE | ID: mdl-17225805

RESUMO

This paper investigates electrical transient characteristics of a Rosen-type piezoelectric transformer (PT), including maximum voltages, time constants, energy losses and average powers, and their improvements immediately after turning OFF. A parallel resistor connected to both input terminals of the PT is needed to improve the transient characteristics. An equivalent circuit for the PT is first given. Then, an open-circuit voltage, involving a direct current (DC) component and an alternating current (AC) component, and its related energy losses are derived from the equivalent circuit with initial conditions. Moreover, an AC power control system, including a DC-to-AC resonant inverter, a control switch and electronic instruments, is constructed to determine the electrical characteristics of the OFF transient state. Furthermore, the effects of the parallel resistor on the transient characteristics at different parallel resistances are measured. The advantages of adding the parallel resistor also are discussed. From the measured results, the DC time constant is greatly decreased from 9 to 0.04 ms by a 10 k(omega) parallel resistance under open output.


Assuntos
Acústica/instrumentação , Desenho Assistido por Computador , Eletroquímica/instrumentação , Eletrônica , Microeletrodos , Modelos Teóricos , Transdutores , Simulação por Computador , Impedância Elétrica , Eletroquímica/métodos , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento
4.
Artigo em Inglês | MEDLINE | ID: mdl-16285452

RESUMO

This paper investigates the characteristics of voltage transient response, such as the maximum voltage, direct current (DC) time constant, alternating current (AC) time constant and oscillation frequency, and their applications for a Rosen-type piezoelectric transformer (PT). The transient response is induced immediately after an AC voltage connected to the PT is switched off. For the applications, the maximum voltage is used to elucidate how to cause an electrical shock for users of the PT under open-circuit operation. The DC time constant and the AC time constant are used to estimate the equivalent resistance of the mechanical loss and the dielectric resistance of the dielectric loss, respectively. Also, the AC time constant is used to estimate the quality factor of the PT. Additionally, the oscillation frequency is used as an antiresonant frequency of the PT. In order to verify the above characteristics and applications, both an equivalent circuit with initial conditions and a drive system with a control switch interposed between the PT and its AC voltage source are adopted to derive the transient response and measure its characteristics. Effects of the load resistance of the PT and the switching-off time of the voltage source on the transient response are measured and discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA