Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Transplant Proc ; 56(3): 494-498, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38342747

RESUMO

The deficiency of organ donors remains a barrier to kidney transplantation. Living donor kidney transplantation (LDKT) can overcome graft shortage, resulting in better outcomes. Many efforts are being made to expand the donor pool, such as hepatitis B surface antigen (HBsAg)-positive donors to negative recipients and anatomically complicated donor kidneys with size discrepancies. We report a case in which we overcame various problems in LDKT. The recipient was a 56-year-old, 106-kg, HBsAg negative male with diabetic nephropathy. The donor was a 63-year-old female, 56-kg, hepatitis B virus (HBV) carrier with dual renal arteries. Preoperative antiviral medication was provided to the donor for negative conversion of HBV-DNA. The recipient was given HBV vaccination (antihepatitis B antibody: 2.25-36.16 mIU/mL). Anti-HBV immunoglobulin was intraoperatively administered to prevent transmission. The donor and recipient had an absolute weight difference (50 kg). In addition, the donor's kidney had a main and an accessory artery in the upper pole, which were anastomosed to the recipient's right external iliac and inferior epigastric artery, respectively. Follow-up serum creatinine levels decreased. Doppler ultrasonography showed good vascular flow within the reference range of the resistive index. The recipient's follow-up HBV-DNA titer was negative with antiviral medication. We successfully performed LDKT from an HBV-positive donor to a negative recipient by perioperative antiviral treatment and overcame a significant size discrepancy and anatomic challenges by preserving even a small portion of the kidney graft.


Assuntos
Antígenos de Superfície da Hepatite B , Transplante de Rim , Doadores Vivos , Humanos , Pessoa de Meia-Idade , Feminino , Masculino , Antígenos de Superfície da Hepatite B/sangue , Hepatite B/cirurgia , Tamanho do Órgão , Rim/virologia
2.
Clin Transplant Res ; 38(1): 52-56, 2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38282513

RESUMO

To address a donor kidney shortage, marginal grafts have been applied in deceased donor kidney transplantation (DDKT). These grafts exhibit comparatively unfavorable outcomes, particularly when cold ischemia time (CIT) is prolonged. Hypothermic machine perfusion (HMP) has been investigated to mitigate the effects of prolonged CIT during graft transport. The present case involved successful management of the longest CIT recorded in Korea by employing HMP in DDKT. The donor was a 54-year-old man (Korean Kidney Donor Profile Index, 82%) with diabetes. The recipient, a 51-year-old man on peritoneal dialysis, had end-stage renal disease secondary to diabetic nephropathy. Following procurement, the left kidney was preserved using HMP. Inclement weather delayed graft transportation; consequently, the total CIT was 28 hours and 6 minutes, with the kidney preserved by HMP for 22 hours and 35 minutes. Postoperative graft function gradually recovered, and urine output was satisfactory. Delayed graft function was not observed, and the patient was discharged on postoperative day 13 without significant complications. Five months after surgery, his serum creatinine level was 1.7 mg/dL. Successful DDKT with a marginal donor graft via HMP, despite the longest CIT yet observed in Korea, underscores the usefulness of HMP in enhancing graft quality and preserving function.

3.
Korean J Transplant ; 37(2): 129-134, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37435149

RESUMO

To overcome the shortage of donor grafts in kidney transplantation (KT), the use of marginal grafts has evolved. However, prolonged cold ischemic time (CIT) is especially critical when using marginal grafts. Recently, hypothermic machine perfusion (HMP) has been used to overcome the negative effects of prolonged CIT, and we report the first use of HMP in Korea. The donor was a 58-year-old man with severe hypoxia (PaO2 <60 mmHg, FiO2 100%) for 9 hours prior to procurement. The patient's kidneys were the only organs accepted for transplantation, and both kidneys were assigned to Jeju National University Hospital. After procurement, the right kidney was preserved using HMP immediately, and the left kidney was directly transplanted into a patient with a CIT of 2 hours 31 minutes. The second operation was performed following the first, using the right kidney graft that had been preserved by HMP for 10 hours and 30 minutes. Although postoperative graft function gradually recovered in both patients, the serum creatinine level decreased faster in the HMP patient. Neither patient showed signs of delayed graft function, and both were discharged without significant complications. The short-term outcomes in this transplantation of mate kidney grafts demonstrated that graft function can be safely preserved using HMP, and that HMP is beneficial in overcoming the negative effects of prolonged CIT.

4.
World J Clin Cases ; 10(31): 11561-11566, 2022 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-36387812

RESUMO

BACKGROUND: Lymphangiomas are rare benign tumors most commonly found in children under 2 years of age; adult cases are extremely rare. Retroperitoneal lymphangiomas represent less than 1% of all lymphangiomas. Because of their benign nature and possibility of spontaneous resolution, lymphangiomas are sometimes left untreated for long periods of time. However, if they grow large enough to compress surrounding structures, retroperitoneal lymphangiomas may cause symptoms such as abdominal pain, nausea or vomiting. We report a case of a rapidly growing retroperitoneal lymphangioma in an adult, treated with complete surgical excision. CASE SUMMARY: A 60-year-old female who was diagnosed with an intra-abdominal cystic mass (11 cm × 9.5 cm) seven years ago presented to our hospital with symptoms of early satiety, nausea, and intermittent abdominal pain. Computed tomography (CT) scan confirmed interval enlargement to a 24 cm × 22 cm-sized huge left retroperitoneal mass, causing left hydronephrosis by external compression. Laparotomy was done via long midline incision. Due to severe adhesion between the aorta and the medial border of the mass, the cyst was intentionally opened for fluid aspiration and size reduction. After suture closure of the opening, we proceeded carefully with dissection. Aspiration showed light yellowish serous fluid. The mass was excised completely, and the pathology was consistent with cystic lymphangioma. The post-operative period was uneventful, and the patient was discharged without complications. Follow-up CT scan one month after surgery confirmed complete removal of the mass and decreased left hydronephrosis. CONCLUSION: Excision of the huge retroperitoneal cystic mass resulted in relief of the patient's symptoms, originally caused by external compression, and also ruled out the possibility of malignancy.

5.
Korean J Transplant ; 36(3): 231-235, 2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-36275993

RESUMO

To overcome the shortage of kidney donors, diverse methods have been utilized, including living donor kidney transplantation (LDKT) and extended criteria for deceased donor grafts. Currently, LDKT is a major treatment option. However, in Jeju, deceased donor kidney transplantation (DDKT) has been restricted due to the prolonged cold ischemia time (CIT) caused by the island's geographic disadvantages and transportation limitations. We report the first LDKT in Jeju, which demonstrates a means of overcoming prolonged CIT. A 67-year-old male patient with diabetic nephropathy underwent a preemptive ABO compatible LDKT (ABO type O+) from his 62-year-old wife. The operation was uneventful, using anti-thymocyte globulin based on the recipient's medical and immunologic risks. The patient recovered without significant complications and was discharged on postoperative day 15. Follow-up Doppler ultrasonography showed good blood flow to the kidney, and his serum creatinine levels steadily decreased and remained stable. The first successful LDKT in Jeju was significant in that kidney transplantation was implemented by compensating for its geographic limitations. In addition, we review machine perfusion as another method of avoiding prolonged CIT.

6.
Korean J Transplant ; 36(1): 67-72, 2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35769426

RESUMO

Short donor renal vessels during donor nephrectomy represent a technical challenge. The allograft of vessels from deceased donors can be an option for reconstruction; however, cryopreserved vessels are not routinely prepared for living donor kidney transplantation (LDKT). We report a reconstruction of the damaged short renal artery (RA) in LDKT using a polytetrafluoroethylene (PTFE) graft. A 45-year-old male patient underwent ABO-incompatible LDKT from his wife. After donor nephrectomy, we detected a hematoma surrounding the proximal RA of the allograft. The injured segment of the RA was transected, and the short RA was connected to the right external artery of the recipient; however, the blood flow was interrupted by the graft location. Once the arterial anastomosis was removed, the graft was flushed with cold saline, and a PTFE graft was used for the reconstruction of the short RA. Immediate blood flow to the renal graft was excellent without sign of parenchymal infarction until fascial closure. Renal graft Doppler on postoperative day 7 and 3 months showed good blood flow. In this patient, the use of PTFE graft presented no additional morbidity to the kidney transplantation, and no postoperative complications related to its use were noted.

7.
Ann Surg Treat Res ; 94(2): 106-111, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29441341

RESUMO

Since multiport laparoscopic cholecystectomy has become a standard treatment for gallbladder (GB) disease, a single incision laparoscopic surgical technique has been tried to decrease the surgical site pain and achieve a better cosmetic out come in selected patients. The development of devices dedicated for single incision laparoscopic cholecystectomy (SILC) is expanding the indication of this single incision laparoscopic technique to more complicated GB diseases. Mirizzi syndrome (MS) is one of the complex uncommon gallstone diseases in patients undergoing cholecystectomy. Because the laparoscopic procedure has become a routine treatment for cholecystectomy, several studies have reported their experience with the laparoscopic technique for the treatment of MS with a comparable outcome in Csendes type I or II. Because the indication for SILC cholecystectomy is expanded to more complicated GB conditions, and the desire of patients for a less painful, better cosmetic surgical outcome has increased, our medical center used this single incision laparoscopic surgical technique for MS Csendes types I and II patients. Here, we report 2 successful cases of SILC for patients with MS types I and II without significant morbidity.

8.
ASAIO J ; 56(4): 369-76, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20467298

RESUMO

Data from early in vivo experiments demonstrated that the child-size Jarvik heart was capable of providing partial to nearly complete circulatory support with acceptable adverse effects on blood. However, bearing thrombosis was responsible for device malfunction in most cases. To overcome this problem, original pin bearings were replaced with novel conical bearings. This study evaluated chronic in vivo performance of the modified child-size Jarvik heart in the pediatric setting. Six juvenile sheep were implanted with the modified child-size Jarvik heart. Cardiac and pump output were measured daily. Serial blood samples were drawn to evaluate hematology, biocompatibility, and end-organ function. End-organ damage and device thrombosis were examined at necropsy. No device malfunction occurred during animal experiments up to 70 days. Mean cardiac output of the animals was 3.4 L/min. The child-size Jarvik heart was able to deliver a blood flow ranging from 1.4 to 2.5 L/min at speed from 10,000 rpm to 14,000 rpm. Mean plasma-free hemoglobin was 9.8 +/- 5.6 mg/dl, indicating no hemolysis. Acute elevation occurred in some organ function tests after the implant surgery but returned to normal range thereafter. These indices and necropsy showed no end-organ damage. No device thrombosis was observed. The current in vivo experience shows that the modified child Jarvik 2000 heart retained its hemodynamic function and excellent biocompatibility, and the conical bearings permitted it to remain free of thrombus.


Assuntos
Coração Artificial , Hemodinâmica/fisiologia , Animais , Desenho de Equipamento , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA