Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 30(25): 45676-45693, 2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36522968

RESUMO

We propose a new architecture of phase sensitive optical frequency converter based on dual-pump phase sensitive amplification in a highly nonlinear fiber. This frequency converter allows generation of extra tones through nonlinear four-wave mixing between two strong pumps and an input tone. The frequency channel to which the input tone is converted can be chosen by adjusting the phase of the input signal. The conversion efficiency and extinction ratio of this frequency converter are predicted and optimized and its noise figure is calculated using a numerical approach based on the nonlinear Schrödinger equation. A semi-classical noise figure calculation for this approach was used and validated using an analytical fully quantum calculation based on the multi-wave model.

2.
Opt Express ; 26(20): 26217-26226, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30469712

RESUMO

We report a fully-correlated multi-mode pumping architecture optimized for dramatic noise reduction of a class-A dual-frequency Vertical External Cavity Surface Emitting Laser (VECSEL). Thanks to amplitude division of a laser diode, the two orthogonally polarized modes emitted by the VECSEL oscillating at 852 nm are separately pumped by two beams exhibiting fully in-phase correlated intensity noises. This is shown to lead to very strong and in-phase correlations between the two lasing modes intensities. As a result, the phase noise power spectral density of the RF beat note generated by the two modes undergoes a drastic reduction of about 10 to 20 dB throughout the whole frequency range from 10 kHz to 20 MHz and falls below the detection floor above a few MHz. A good agreement is found with a model which uses the framework of rate equations coupled by cross-saturation. The remaining phase noise is attributed to thermal effects and additional technical noises and lies mainly within the bandwidth of a phase-locked-loop.

3.
Opt Lett ; 43(18): 4546-4549, 2018 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-30211912

RESUMO

We experimentally investigate the evolution of the direct detection noise figure of a nondegenerate phase-sensitive amplifier based on a nonlinear fiber, as a function of the relative phase between the signal, idler, and pump, all other parameters remaining fixed. The use of a fiber with a high stimulated Brillouin scattering threshold permits us to investigate the full range of phase-sensitive gain and noise figure without pump dithering. Good agreement is found with theory, both for signal only and combined signal and idler direct detections.

4.
ACS Appl Mater Interfaces ; 8(27): 17127-37, 2016 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-27331869

RESUMO

Bioactive nanomaterials, namely, gallium oxyhydroxide GaO(OH), also surface-conjugated GaO(OH) with a giant sugar molecule ß-cyclodextrin (CD), have been prepared through a simple wet chemical route such that the same could be suitably used in biomedical diagnostics as well as therapeutic applications. Several physical methods were used for their characterization: powder X-ray diffraction pattern of GaO(OH) NPs for their grain size determination, optical spectroscopic absorption (UV-vis and FT-IR), and fluorescence properties of these NPs to ascertain surface conjugation and also their wide band-gap properties. Besides these, morphological properties of these NPs were studied by transmission electron microscopic (TEM) investigation, justifying the elemental constitution through energy dispersive X-ray analysis (EDX). Further, biological cellular uptake of these nanoparticles have been demonstrated on cancerous HeLa cells and reported with total fetal effect after 72 h, with CD templated GaO(OH) nanoparticles, a fact that has not been reported so far.


Assuntos
Nanopartículas Metálicas , Gálio , Células HeLa , Humanos , Espectroscopia de Infravermelho com Transformada de Fourier , beta-Ciclodextrinas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA