Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Intensive Care Med ; 42(11): 1753-1765, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27734108

RESUMO

PURPOSE: To describe all post-insertion complications involving most used intravascular access, and to determine whether the use of a new-generation transparent dressing (3M™ IV Advanced) might reduce their number and impact on ICU patient outcomes. METHODS: Patients older than 18, with an expected length of stay ≥48 h and requiring at least one central venous catheter (CVC), arterial catheter (AC), haemodialysis catheter (HDC), pulmonary arterial catheters (PAC) or peripheral venous catheter (PVC) were randomized into two groups: a new-generation transparent dressing, or the hospital's classical transparent dressing, and were followed daily for any infectious and non-infectious complications. Complications were graduated for severity by an independent international multicentre multidisciplinary panel of practitioners using a Delphi process. RESULTS: We included 628 patients, 2214 catheters (873 PVCs, 630 CVCs, 512 ACs and 199 HDCs and PACs) and 4836 dressings. Overall incidence rate was of 60.9/1000 catheter-days. The most common complication was dysfunction (34.6/1000 catheter-days), mainly for PVCs (16/1000 catheter-days) and ACs (12.9/1000 catheter-days). Infectious complications incidence rate in CVCs and ACs was of 14.5/1000, mostly due to colonization (14.2/1000 catheter-days). Thrombosis incidence was of 3.8/1000 catheter-days with severe and very severe complications in 16 cases (1.8/1000 catheter-days) and one thrombosis-related death. 3M™ IV Advanced dressing did not decrease the rate of catheters with at least a minor complication [57.37/1000 vs. 57.52/1000 catheter-days, HR 1.03, CI (0.84-1.27), p = 0.81]. Incidence rates for each single complication remained equivalent: infectious [HR 0.93 (0.62-1.40), p = 0.72], deep thrombosis [HR 0.90 (0.39-2.06), p = 0.80], extravasation and phlebitis [HR 1.40 (0.69-2.82), p = 0.35], accidental removal [1.07 (0.56-2.04), p = 0.84] and dysfunction [HR 1.04 (0.80-1.35), p = 0.79]. CONCLUSION: The ADVANCED study showed the overall risk of complications to intravascular catheters in ICU patients being dysfunction, infection and thrombosis. The 3M™ IV Advanced dressing did not decrease complication rates as compared to standard dressings.


Assuntos
Bandagens , Infecções Relacionadas a Cateter/etiologia , Cateterismo Periférico/efeitos adversos , Cateteres de Demora/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Trombose/etiologia , Adulto , Técnica Delphi , Falha de Equipamento , Feminino , Humanos , Incidência , Unidades de Terapia Intensiva , Análise de Intenção de Tratamento , Tempo de Internação , Masculino , Estudos Prospectivos , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA