Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Clin Neurophysiol ; 33(4): 328-32, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27482790

RESUMO

This EEG Guideline incorporates the practice of structuring a report of results obtained during routine adult electroencephalography. It is intended to reflect one of the current practices in reporting an EEG and serves as a revision of the previous guideline entitled "Writing an EEG Report." The goal of this guideline is not only to convey clinically relevant information, but also to improve interrater reliability for clinical and research use by standardizing the format of EEG reports. With this in mind, there is expanded documentation of the patient history to include more relevant clinical information that can affect the EEG recording and interpretation. Recommendations for the technical conditions of the recording are also enhanced to include post hoc review parameters and type of EEG recording. Sleep feature documentation is also expanded upon. More descriptive terms are included for background features and interictal discharges that are concordant with efforts to standardize terminology. In the clinical correlation section, examples of common clinical scenarios are now provided that encourages uniformity in reporting. Including digital samples of abnormal waveforms is now readily available with current EEG recording systems and may be beneficial in augmenting reports when controversial waveforms or important features are encountered.


Assuntos
Eletroencefalografia/normas , Prontuários Médicos/normas , Neurofisiologia/normas , Guias de Prática Clínica como Assunto/normas , Sociedades Médicas/normas , Humanos , Estados Unidos
2.
J Clin Neurophysiol ; 33(4): 320-3, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27482791

RESUMO

This revision to the EEG Guidelines is an update incorporating the current electroencephalography technology and practice. It was previously published as Guideline 2. Similar to the prior guideline, it delineates the aspects of Guideline 1 that should be modified for neonates and young children. Recording conditions for photic stimulation and hyperventilation are revised to enhance the provocation of epileptiform discharges. Revisions recognize the difficulties involved in performing an EEG under sedation in young children. Recommended neonatal EEG montages are displayed for the reduced set of electrodes only since the montages in Guideline 3 should be used for a 21-electrode 10-20 system array. Neonatal documentation is updated to use current American Academy of Pediatrics term "postmenstrual age" rather than "conceptional age." Finally, because therapeutic hypothermia alters the prognostic value of neonatal EEG, the necessity of documenting the patient's temperature at the time of recording is emphasized.


Assuntos
Eletroencefalografia/normas , Neurofisiologia/normas , Pediatria/normas , Guias de Prática Clínica como Assunto/normas , Sociedades Médicas/normas , Criança , Humanos , Estados Unidos
3.
J Clin Neurophysiol ; 33(4): 308-11, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27482794

RESUMO

This revision to the EEG Guidelines is an update incorporating current electroencephalography technology and practice and was previously published as Guideline 5. While the 10-10 system of electrode position nomenclature has been accepted internationally for almost two decades, it has not been used universally. The reasons for this and clinical scenarios when the 10-10 system provides additional localizing information are discussed in this revision. In addition, situations in which AF1/2, AF5/6, PO1/2 and PO5/6 electrode positions may be utilized for EEG recording are discussed.


Assuntos
Eletroencefalografia/normas , Neurofisiologia/normas , Guias de Prática Clínica como Assunto/normas , Sociedades Médicas/normas , Eletrodos , Eletroencefalografia/instrumentação , Humanos , Estados Unidos
4.
Neurodiagn J ; 56(4): 285-293, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28436792

RESUMO

This EEG Guideline incorporates the practice of structuring a report of results obtained during routine adult electroencephalography. It is intended to reflect one of the current practices in reporting an EEG and serves as a revision of the previous guideline entitled "Writing an EEG Report." The goal of this guideline is not only to convey clinically relevant information, but also to improve interrater reliability for clinical and research use by standardizing the format of EEG reports. With this in mind, there is expanded documentation of the patient history to include more relevant clinical information that can affect the EEG recording and interpretation. Recommendations for the technical conditions of the recording are also enhanced to include post hoc review parameters and type of EEG recording. Sleep feature documentation is also expanded upon. More descriptive terms are included for background features and interictal discharges that are concordant with efforts to standardize terminology. In the clinical correlation section, examples of common clinical scenarios are now provided that encourages uniformity in reporting. Including digital samples of abnormal waveforms is now readily available with current EEG recording systems and may be beneficial in augmenting reports when controversial waveforms or important features are encountered.


Assuntos
Documentação/normas , Eletroencefalografia/normas , Humanos , Neurofisiologia , Sociedades Médicas , Estados Unidos
5.
Neurodiagn J ; 56(4): 245-252, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28436791

RESUMO

This revision to the EEG Guidelines is an update incorporating current electroencephalography technology and practice and was previously published as Guideline 5. While the 10-10 system of electrode position nomenclature has been accepted internationally for almost two decades, it has not been used universally. The reasons for this and clinical scenarios when the 10-10 system provides additional localizing information are discussed in this revision. In addition, situations in which AF1/2, AF5/6, PO1/2 and PO5/6 electrode positions may be utilized for EEG recording are discussed.


Assuntos
Eletrodos , Eletroencefalografia/métodos , Padrões de Referência , Terminologia como Assunto , Humanos , Neurofisiologia , Sociedades Médicas , Estados Unidos
6.
Neurodiagn J ; 56(4): 266-275, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28436801

RESUMO

This revision to the EEG Guidelines is an update incorporating the current electroencephalography technology and practice. It was previously published as Guideline 2. Similar to the prior guideline, it delineates the aspects of Guideline 1 that should be modified for neonates and young children. Recording conditions for photic stimulation and hyperventilation are revised to enhance the provocation of epileptiform discharges. Revisions recognize the difficulties involved in performing an EEG under sedation in young children. Recommended neonatal EEG montages are displayed for the reduced set of electrodes only since the montages in Guideline 3 should be used for a 21-electrode 10-20 system array. Neonatal documentation is updated to use current American Academy of Pediatrics term "postmenstrual age" rather than "conceptional age." Finally, because therapeutic hypothermia alters the prognostic value of neonatal EEG, the necessity of documenting the patient's temperature at the time of recording is emphasized.


Assuntos
Eletroencefalografia/normas , Temperatura Corporal , Criança , Pré-Escolar , Eletrodos/normas , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Equipamentos e Provisões/normas , Humanos , Hipotermia Induzida , Lactente , Recém-Nascido , Neurofisiologia , Estimulação Luminosa , Sociedades Médicas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA