Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Nat Cell Biol ; 3(7): 613-8, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11433291

RESUMO

Specific recognition of phosphoinositides is crucial for protein sorting and membrane trafficking. Protein transport to the yeast vacuole depends on the Vam7 t-SNARE and its phox homology (PX) domain. Here, we show that the PX domain of Vam7 targets to vacuoles in vivo in a manner dependent on phosphatidylinositol 3-phosphate generation. A novel phosphatidylinositol-3-phosphate-binding motif and an exposed loop that interacts with the lipid bilayer are identified by nuclear magnetic resonance spectroscopy. Conservation of key structural and binding site residues across the diverse PX family indicates a shared fold and phosphoinositide recognition function.


Assuntos
Proteínas Fúngicas/metabolismo , Proteínas de Membrana/metabolismo , Proteínas do Tecido Nervoso/metabolismo , Fosfatos de Fosfatidilinositol/metabolismo , Proteínas de Transporte Vesicular , Sequência de Aminoácidos , Sítios de Ligação , Proteínas Fúngicas/química , Membranas Intracelulares/química , Membranas Intracelulares/metabolismo , Proteínas de Membrana/química , Membranas Artificiais , Microscopia de Fluorescência , Dados de Sequência Molecular , Ressonância Magnética Nuclear Biomolecular , Fosfatos de Fosfatidilinositol/química , Fosfatos de Fosfatidilinositol/fisiologia , Ligação Proteica , Estrutura Terciária de Proteína , Transporte Proteico/fisiologia , Proteínas Qc-SNARE , Proteínas SNARE , Saccharomyces cerevisiae , Proteínas de Saccharomyces cerevisiae , Alinhamento de Sequência , Proteína 25 Associada a Sinaptossoma , Vacúolos/fisiologia , Vacúolos/ultraestrutura
2.
J Anal Toxicol ; 25(3): 190-7, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11327351

RESUMO

Two types of immunoassays, radioimmunoassay (RIA) and microplate enzyme immunoassay (EIA), were compared for their ability to detect and quantitate cocaine and metabolites or heroin and metabolites in extracts of sweat patches. Experiments used sweat patches that had been fortified with cocaine, benzoylecgonine (BE), and ecgonine methyl ester (EME) or 6-acetylmorphine (6-AM), heroin, and morphine. Assays were first evaluated for sensitivity in detection of the analyte(s) known to be excreted in sweat (cocaine >> BE and EME; 6-AM > heroin > morphine). The cocaine metabolite RIA had cross-reactivity for cocaine > BE > EME, and the cocaine metabolite EIA had cross-reactivity for BE > cocaine >> EME. The RIA, having greater sensitivity for COC, was studied further. Optimal linearity was 4 to 200 ng/patch, and quantitation within these limits at 4, 75, and 150 ng/patch had intrarun %CVs within 7.8% and percent targets within 15% and inter-run %CVs within 13.5% and % targets within 13%. The opiate RIA had cross-reactivities for morphine >> 6-AM and heroin. The opiate EIA had cross-reactivities for 6-AM and heroin of 42 and 28% relative to morphine, respectively. The EIA, having greater sensitivity for 6-AM and heroin, was studied further. The limits of detection ranged from 1.7 to 24.7 ng/patch, and the lower limits of quantitation ranged from 7.3 ng/patch to beyond the linear range. The assay, however, had consistently good precision at 4 and 5 ng/patch, and optimal linearity was established from 4 to 100 ng/patch. With controls at 5, 25, and 90 ng/patch, both intrarun and inter-run precision were acceptable. Quantitation was accurate at 5 and 25 ng/patch, but the 90 ng/patch controls were consistently < 70% of target. Because our studies focused on the assays that had greater sensitivity for the analytes excreted in sweat, we did not fully evaluate the cocaine metabolite EIA or the RIA opiate screen and therefore cannot make any comment on the usefulness of these assays for detecting analytes in extracts of sweat patches beyond predicting that they will have less sensitivity. Both the cocaine metabolite RIA and opiate EIA had the ability to detect analytes known to be extracted from sweat patches.


Assuntos
Cocaína/análogos & derivados , Cocaína/análise , Heroína/análise , Entorpecentes/análise , Detecção do Abuso de Substâncias/métodos , Suor/química , Humanos , Técnicas Imunoenzimáticas , Morfina/análise , Derivados da Morfina/análise , Radioimunoensaio
3.
Mol Interv ; 1(3): 150-9, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-14993348

RESUMO

When the outside of cell is stimulated,the inside generates a flurry of signals. Phosphates are sprinkled over lipids and proteins,where they are recognized within diverse signaling pathways. The kinases that congregate beneath the cell surface to provide the phosphate tags that mediate signaling have become major targets of new wave of drug design. Phosphoinositide signaling presents a particularly intriguing network whose many mysteries are now being unlocked. Research into protein domains that specifically recognize phosphoinositides have established the ENTH, FYVE,Phox,and pleckstrin homology domains s four cornerstones of phosphoinositide signaling.


Assuntos
Fosfatidilinositóis/metabolismo , Transdução de Sinais , 1-Fosfatidilinositol 4-Quinase/metabolismo , Animais , Humanos , Modelos Moleculares , Fosfatidilinositóis/química , Monoéster Fosfórico Hidrolases/metabolismo , Fosforilação , Estrutura Terciária de Proteína
4.
J Anal Toxicol ; 23(6): 452-9, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10517550

RESUMO

A clinical study was designed to determine if there was a predictable relationship between saliva and plasma codeine concentrations. Drug-free volunteers (n = 17) were administered a 30-mg dose of liquid codeine phosphate. Plasma and saliva specimens were collected at various times for 24 h after administration. Plasma and saliva were analyzed for codeine and morphine by positive-ion chemical ionization gas chromatography-mass spectrometry. The plasma codeine concentrations peaked between 30 min and 2 h after administration and ranged from 19 to 74 ng/mL with a mean of 46 ng/mL. Despite decontamination procedures, elevated saliva codeine concentrations were detected at the early collection times because of contamination of the oral cavity from the liquid codeine. Codeine concentrations in the 15 min specimens ranged from 690 ng/mL to over 15,000 ng/mL. After the initial 2-h period, the mean codeine saliva concentrations declined at a rate similar to that observed in the plasma, but remained 3 to 4 times greater than the plasma concentrations. During the elimination phase, half-life estimates for codeine in plasma and saliva were found to be equivalent, 2.6 and 2.9 h, respectively. However, the area under the curve (AUC) estimate for codeine in saliva was 13 times greater than the plasma AUC. Contamination of the saliva resulted in elevated saliva/plasma (S/P) concentration ratios for the first 1 to 2 h after drug administration. Consequently, S/P ratios in specimens collected in the first 15 to 30 min ranged from 75 to 2580. However, after the absorption phase, a significant correlation between saliva and plasma concentrations was observed (r = 0.809, p < 0.05) and mean S/P ratios remained constant (mean = 3.7). Although small changes in saliva pH were predicted to produce profound changes in the S/P ratios for codeine, this was not observed in the current study. Therefore, saliva codeine concentrations could be used to estimate plasma concentrations through the use of the S/P ratio once the oral contamination has been eliminated. However, these estimates should be made cautiously. One must ensure that oral contamination is not a factor. Also, as with blood-drug concentrations, considerable intersubject variability was observed.


Assuntos
Codeína/análise , Codeína/metabolismo , Saliva/química , Administração Oral , Codeína/sangue , Relação Dose-Resposta a Droga , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Concentração de Íons de Hidrogênio , Fatores de Tempo
5.
J Anal Toxicol ; 23(6): 500-5, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10517557

RESUMO

l-Alpha-acetylmethadol (LAAM) was recently approved as a substitute for methadone. LAAM, methadone, and their common metabolite, methadol, are extensively N-demethylated. The structural similarities of LAAM and its metabolites to methadone suggest that they may cross-react in methadone immunoassays. To test this hypothesis, drug-free urine was fortified with LAAM, norLAAM, dinorLAAM, methadol, normethadol, dinormethadol, methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), or 2-ethyl-5-methyl-3,3-diphenylpyrroline (EMDP) at 12 concentrations (0.03 to 100 microg/mL). Samples were analyzed using two enzyme immunoassays (Behring Diagnostics, EIA-b; Diagnostic Reagents, EIA-d); a fluorescent polarization immunoassay (Abbott, FPIA); two enzyme-linked immunosorbant immunoassays (Diagnostix, ELISA-d; STC Technologies, ELISA-s); a kinetic microparticles in solution immunoassay (Roche Diagnostic Systems, KIMS); and a radioimmunoassay (Diagnostic Products, RIA). LAAM had high cross-reactivity with ELISA-d (318.3%), RIA (249.5%), EIA-d (100.8%), KIMS (91.1%), and ELISA-s (75.3%). Methadol also displayed relatively high cross-reactivity as follows: EIA-d (97.8%), KIMS (85.4%), ELISA-d (70.3%), and FPIA (37.7%). Successive N-demethylations of LAAM and methadol were associated with loss of cross-reactivity. The methadone metabolites EDDP and EMDP showed little cross-reactivity. These findings suggest that LAAM use could result in positive immunoassay test results when using many of the commercially available methadone immunoassay kits and that confirmation of LAAM and its metabolites should be considered.


Assuntos
Metadona/urina , Acetato de Metadil/urina , Urina/química , Reações Cruzadas , Relação Dose-Resposta a Droga , Imunoensaio de Fluorescência por Polarização , Humanos , Técnicas Imunoenzimáticas , Técnicas de Imunoadsorção , Técnicas In Vitro , Metadona/metabolismo , Acetato de Metadil/metabolismo , Radioimunoensaio
6.
Hear Res ; 134(1-2): 9-15, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10452371

RESUMO

The CBA/CaJ (CB) and C57BL/6J (B6) inbred strains of mice were exposed for 1 h to noise intensities between 98 and 119 dB SPL. Previous studies indicated that the B6 mice exhibited permanent threshold shifts (PTS) after 1h exposure to 110 dB, whereas the CB mice did not exhibit any PTS. These differences in susceptibility to noise-induced hearing loss (NIHL) appear to be due to a gene for age-related hearing loss (AHL). The current study was designed to determine dose-response curves for NIHL over the ranges of intensities of noise that would characterize the B6 and CB inbred strains of mice. Because of the considerable differences in sensitivity to NIHL, the noise exposures for the two strains overlapped only at 110 and 113 dB. Nevertheless, the two strains exhibited two different dose-response curves, offset and with different slopes. We postulate that the B6 strain of mice exhibits a more linear increase for PTS from 98-113 dB, consistent with incremental effects on some metabolic physiological mechanism(s); the abrupt transition in NIHL between 113 and 116 dB for the CB mice is consistent with an ototraumatic structural injury.


Assuntos
Predisposição Genética para Doença , Perda Auditiva Provocada por Ruído/genética , Camundongos Endogâmicos C57BL/genética , Camundongos Endogâmicos CBA/genética , Animais , Limiar Auditivo/fisiologia , Relação Dose-Resposta à Radiação , Camundongos , Modelos Biológicos , Especificidade da Espécie
7.
J Forensic Sci ; 43(1): 35-40, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9456522

RESUMO

This study was designed to compare results obtained from two separate on-site drug testing kits (ONTRAK TESTCUP and Abuscreen ONTRAK) with those obtained from laboratory based immunoassay and GC/MS. Abuscreen ONLINE immunoassay was used to select 250 negative samples and 100 presumptive-positive samples each for cocaine/metabolites, opiates and cannabinoids. Presumptive-positive samples were selected if the immunoassay response was > or = 300 ng/mL for cocaine/metabolites (BZE), > or = 300 ng/mL for opiates or > or = 50 ng/mL for cannabinoids (THC-COOH). GC/MS was used to confirm that each selected sample contained > or = 150 ng/mL BZE, > or = 300 ng/mL morphine/codeine or > or = ng/mL THC-COOH. TESTCUP results had a 100% agreement with GC/MS and a > 99% agreement with ONLINE when testing negative samples. The agreement between TESTCUP and ONLINE results for samples containing opiates was 100%. Results of testing samples containing BZE with TESTCUP demonstrated a 98% agreement with both GC/MS and ONLINE. Both discrepant samples contained BZE at concentrations < or = 300 ng/mL. The least agreement between TESTCUP and ONLINE results was found when testing samples containing THC-COOH. The agreement with ONLINE and GC/MS was 92% and all discrepant samples had GC/MS determined THC-COOH concentrations less than 50 ng/mL. A 100% agreement was obtained between expected and recorded TESTCUP results for QC samples fortified to contained BZE, morphine or THC-COOH at concentrations within 120% of the screening cutoffs. ONTRAK had a 100% agreement with both GC/MS and ONLINE when testing negative samples and samples that contained opiates. ONTRAK had a 91% agreement with GC/MS and ONLINE for testing of samples that contained BZE. The least agreement between ONTRAK and ONLINE results was found when testing samples that contained THC-COOH. The agreement was 89%, however, all discrepant samples contained GC/MS concentrations of THC-COOH less that the 50 ng/mL cutoff. With ONTRAK, a 100% agreement was obtained between expected and recorded results QC samples that contained morphine or THC-COOH and a 97.7% agreement was obtained between expected and recorded results on QC samples that contained BZE.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/normas , Imunoensaio/normas , Detecção do Abuso de Substâncias/normas , Urinálise/métodos , Canabinoides/urina , Cocaína/urina , Medicina Legal/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Imunoensaio/métodos , Morfina/urina , Entorpecentes/urina , Controle de Qualidade , Sensibilidade e Especificidade , Detecção do Abuso de Substâncias/métodos , Toxicologia/métodos , Urinálise/instrumentação , Urinálise/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA