Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Am J Cardiol ; 222: 20-22, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38663573

RESUMO

Transcatheter aortic valve implantation (TAVI) in native pure aortic regurgitation (AR) with off-label use of balloon-expandable valves (BEV) has been reported. However, there are scant data regarding optimal oversizing and its safety, and our study assessed BEV oversizing and outcomes of TAVI. Thirteen consecutive tricuspid aortic valve patients who underwent transfemoral TAVIs for pure AR with Sapien BEV at our center between 2019 and 2023 (69.2% males, mean age 80.8 years, Society of Thoracic Surgeons 4.0%) were divided into small annulus (SA) group (≤618 mm2) where ≥20% oversizing is achievable based on published data on BEV overexpansion, and larger annulus (LA) group (>618 mm2). Overexpansion and actual oversizing were measured on postprocedural computed tomography scan. Technical success was 92.3% with 1 valve embolization in the LA group. The postprocedural computed tomography showed a mean 28.3% oversizing, significantly higher in SA (31.2%) than in LA group (19.4%), p = 0.0092. Oversizing ≥20% was achieved in 100% SA versus 33.3% LA patients (p = 0.046). In conclusion, TAVI in pure AR with oversized Sapien BEV showed good procedural and short-term outcomes when ≥20% oversizing was predictably achievable.


Assuntos
Insuficiência da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Feminino , Insuficiência da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Idoso , Estudos Retrospectivos , Uso Off-Label , Resultado do Tratamento , Tomografia Computadorizada por Raios X
2.
JACC Cardiovasc Interv ; 16(4): 396-411, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36858659

RESUMO

BACKGROUND: The optimal access route in patients with severe peripheral artery disease (PAD) undergoing transcatheter aortic valve replacement (TAVR) remains undetermined. OBJECTIVES: This study sought to compare clinical outcomes with transfemoral access (TFA), transthoracic access (TTA), and nonthoracic transalternative access (TAA) in TAVR patients with severe PAD. METHODS: Patients with PAD and hostile femoral access (TFA impossible, or possible only after percutaneous treatment) undergoing TAVR at 28 international centers were included in this registry. The primary endpoint was the propensity-adjusted risk of 30-day major adverse events (MAE) defined as the composite of all-cause mortality, stroke/transient ischemic attack (TIA), or main access site-related Valve Academic Research Consortium 3 major vascular complications. Outcomes were also stratified according to the severity of PAD using a novel risk score (Hostile score). RESULTS: Among the 1,707 patients included in the registry, 518 (30.3%) underwent TAVR with TFA after percutaneous treatment, 642 (37.6%) with TTA, and 547 (32.0%) with TAA (mostly transaxillary). Compared with TTA, both TFA (adjusted HR: 0.58; 95% CI: 0.45-0.75) and TAA (adjusted HR: 0.60; 95% CI: 0.47-0.78) were associated with lower 30-day rates of MAE, driven by fewer access site-related complications. Composite risks at 1 year were also lower with TFA and TAA compared with TTA. TFA compared with TAA was associated with lower 1-year risk of stroke/TIA (adjusted HR: 0.49; 95% CI: 0.24-0.98), a finding confined to patients with low Hostile scores (Pinteraction = 0.049). CONCLUSIONS: Among patients with PAD undergoing TAVR, both TFA and TAA were associated with lower 30-day and 1-year rates of MAE compared with TTA, but 1-year stroke/TIA rates were higher with TAA compared with TFA.


Assuntos
Ataque Isquêmico Transitório , Doença Arterial Periférica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Resultado do Tratamento , Sistema de Registros
3.
J Cardiovasc Med (Hagerstown) ; 24(3): 167-171, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36753724

RESUMO

AIMS: Several causes have been reported for coronary artery ectasia (CAE), mostly atherosclerosis and tunica media abnormalities. The main aim of the present study was to investigate if CAE extension differs in distinct clinical settings. METHODS: Three hundred and forty-one patients with diagnosis of CAE were identified among 9659 coronary angiographies and divided into four groups according to the patient's admission diagnosis: stable or unstable angina (S-UA), myocardial infarction (MI), aortic disease, aortic valvular disease (AVD). S-UA and MI were subgrouped according to the presence of obstructive coronary artery disease (OCAD). Multivariable logistic regression was used to investigate the relationship between clinical diagnosis and CAE extension as expressed by Markis classification and number of coronary vessels affected by CAE. RESULTS: No significant differences in CAE extension were found among the four groups, in terms of vessels affected by CAE (P = 0.37) or Markis class (P = 0.33). CAE was not related to the extension of OCAD as assessed by the Gensini score, which was higher in MI and S-UA groups (P < 0.01). However, when ischemic patients were sub-divided on the basis of the presence of OCAD, MI without obstructive coronary artery disease (MINOCA) was associated with a higher extension of CAE in terms of Markis class 1 (OR 5.08, 95% CI 1.61-16.04; P < 0.01). CONCLUSION: The extension of CAE is comparable in patients referred to coronary angiography for different clinical scenarios, including S-UA, MI, aortic disease, and AVD; however, patients with MINOCA were associated with a higher extension of CAE.Graphical abstract: Difference in coronary artery ectasia extension in terms of Markis class severity, respectively, stratified by clinical presentation and obstructive coronary artery disease presence, http://links.lww.com/JCM/A519.


Assuntos
Aneurisma Coronário , Doença da Artéria Coronariana , Infarto do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Dilatação Patológica , MINOCA , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem
6.
Circ Cardiovasc Interv ; 15(11): 906-914, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36378738

RESUMO

BACKGROUND: Antiplatelet therapy deescalation has been suggested as an alternative to standard treatment with potent dual antiplatelet therapy (DAPT) for 1 year in low bleeding risk patients with acute coronary syndromes undergoing percutaneous coronary intervention to mitigate the increased risk of bleeding. Whether this strategy preserves the ischemic and survival benefits of potent DAPT is uncertain. METHODS: We performed a pairwise meta-analysis in patients with acute coronary syndrome undergoing percutaneous coronary intervention treated with either 1-year standard potent DAPT versus deescalation therapy (potent DAPT for 1-3 months followed by either reduced potency DAPT or ticagrelor monotherapy for up to 1 year). Randomized trials comparing standard DAPT versus deescalation therapy in patients with acute coronary syndrome undergoing percutaneous coronary intervention were searched through MEDLINE, EMBASE, Cochrane databases, and proceedings of international meetings. The primary end point was 1-year all-cause mortality. RESULTS: The meta-analysis included 6 trials in which 20 837 patients were randomized to potent DAPT for 1 to 3 months followed by deescalation therapy for up to 1 year (n=10 392) or standard potent DAPT for 1 year (n=10 445). Deescalation therapy was associated with lower 1-year rates of all-cause mortality compared with standard therapy (odds ratio, 0.75 [95% CI, 0.59-0.95]; P=0.02). Deescalation therapy was also associated with lower rates of major bleeding (odds ratio, 0.59 [95% CI, 0.48-0.72]; P<0.0001), with no significant difference in major adverse cardiac events (major adverse cardiovascular events; odds ratio, 0.89 [95% CI, 0.77-1.04]; P=0.14). CONCLUSIONS: In low bleeding risk patients with acute coronary syndrome undergoing percutaneous coronary intervention, compared with 1-year of potent DAPT, antiplatelet therapy deescalation therapy after 1 to 3 months was associated with decreased mortality and major bleeding with similar rates of major adverse cardiovascular events.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Humanos , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/tratamento farmacológico , Inibidores da Agregação Plaquetária , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Hemorragia , Quimioterapia Combinada , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Int J Cardiol ; 344: 226-229, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34655674

RESUMO

BACKGROUND: Coronary artery ectasia (CAE) is associated with ascending aortic (AA) ectasia. The purpose of this study is to evaluate the diagnostic performance of different echocardiographic parameters (EP) in predicting the presence of CAE. METHODS: Four hundred-eighteen patients with AA ectasia candidate to coronary angiography were identified and divided in two groups in respect of the presence of CAE. Receiver-operating characteristic curves areas (AUC) were used to assess the discrimination power of the following EP: aortic annulus diameter, sinuses of Valsalva (SV) diameter, sino-tubular junction (STJ) diameter, AA diameter, STJ to SV ratio (STJ-to-SV) and STJ to AA ratio (STJ-to-AA). All these parameters were indexed by body surface area. The relationship between the best EP and the presence of CAE was investigated by means of multivariable logistic regression. RESULTS: The rate of CAE in the study population was 32%. On univariable logistic regression, aortic annulus, STJ, STJ-to-SV and STJ-to-AA were associated with the presence of CAE after Bonferroni correction. STJ-to-SV emerged as the parameter with the best discrimination power (AUC = 0.81) compared to STJ (AUC = 0.69), STJ-to-AA (AUC = 0.68), aortic annulus (AUC = 0.59), AA (AUC = 0.56) and SV (AUC = 0.55); (p for comparison <0.01). An 89.6% value for STJ-to-SV ratio emerged as the best cut-off to diagnose CAE with a sensitivity = 75%, specificity = 82%, positive predictive value = 66% and negative predictive value = 88%. On multivariable analysis, STJ-to-SV was still associated with the presence of CAE (OR = 1.15;95%CI:1.11-1.19;p < 0.01). CONCLUSION: In patients with dilated aorta, STJ-to-SV sampled by transthoracic echocardiography shows a good diagnostic performance in predicting the presence of CAE.


Assuntos
Vasos Coronários , Seio Aórtico , Aorta/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Dilatação Patológica/diagnóstico por imagem , Ecocardiografia , Humanos , Seio Aórtico/diagnóstico por imagem
8.
Sensors (Basel) ; 21(3)2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33572922

RESUMO

In this work, the application in Radiofrequency Identification (RFID) of different additive manufacturing (AM) 3D-printing technologies is discussed. In particular, the well-known Fused Deposition Modeling (FDM) technology is compared with the promising Digital Light Processing (DLP), which is based on the photopolymerization of liquid resins. Based on the research activity of the authors on this topic, a brief introduction to the fundamentals of 3D-printing in electromagnetics as well as to the different applications of both FDM and DLP in realizing Radio Frequency (RF) devices, is firstly given. Then, a comparison of the two technologies is deeply faced. Finally, after evaluated the rugosity of substrates produced with both techniques to verify the potential impact on the design of electromagnetic structures, the two techniques are both exploited for the realization of the dielectric parts of a tunable RFID tag with unconventional shape. It consists of two elements interlinked one each other. The movement between them enables tuning of the resonance frequency as well as the impedance of the antenna. Despite the differences in terms of losses, rugosity, resolution, and dielectric constant, both techniques guaranteed satisfactory values of tag sensitivity, maximum reading range, and tunability. Nevertheless, the careful analysis of the results proposed at the end of the paper suggests how the selection of one technique over the other must be taken considering the specific application constraints.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA