Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
J Mater Chem B ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38953113

RESUMO

In this paper, we explore the development of a multi-functional surface designed to tackle the challenges posed by Staphylococcus aureus (S. aureus), a common opportunistic pathogen. Infections caused by S. aureus during surgical procedures highlight the need for effective strategies to inhibit its adhesion, growth, and colonization, particularly on the surfaces of invasive medical devices. Until now, most existing research has focused on nanopillar structures (positive topographies). Uniform nanopillar arrays have been shown to control bacterial behavior based on the spacing between nanopillars. However, nanopillar structures are susceptible to external friction, impact, and force, making it challenging to maintain their antibacterial properties. Therefore, in this study, we investigate the antibacterial behavior of nanohole structures, which offer relatively superior mechanical robustness compared to nanopillars. Moreover, for applications in medical devices such as laparoscopes, there is a pressing need for surfaces that are not only transparent and flexible (or curved) but are also equipped with antibacterial properties. Our study introduces a scalable multi-functional surface that synergistically combines antibacterial and anti-fog properties. This is achieved by fabricating thin films with variously sized holes (ranging from 0.3 µm to 4 µm) using polyurethane acrylate (PUA). We assessed the activity of S. aureus on these surfaces and found that a 1 µm-diameter-hole pattern significantly reduced the presence of live S. aureus, without any detection of dead S. aureus. This bacteriostatic effect is attributed to the restricted proliferation due to the confined area provided by the hole pattern. However, the persistence of some live S. aureus on the surface necessitates further measures to minimize bacterial adhesion and enhance antibacterial effectiveness. To address this challenge, we coated the zwitterionic polymer 2-methacryloyloxyethyl phosphorylcholine (MPC) onto the nanohole pattern surface to reduce S. aureus adhesion. Moreover, in long-term experiments on surfaces, the MPC-coated effectively inhibited the colonization of S. aureus (18 h; 82%, 7 days; 83%, and 14 days; 68% antibacterial rate). By integrating PUA, MPC, and nanohole architectures into a single, flexible platform, we achieved a multi-functional surface catering to transparency, anti-fogging, and anti-biofouling requirements. This innovative approach marks a significant advancement in surface engineering, offering a versatile solution applicable in various fields, particularly in preventing S. aureus contamination in invasive medical devices like laparoscopes. The resultant surface, characterized by its transparency, flexibility, and antibacterial functionality, stands out as a promising candidate for mitigating S. aureus-related risks in medical applications.

2.
Polymers (Basel) ; 16(3)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38337228

RESUMO

In the field of bone tissue engineering, which is being developed for the ideal restoration of bone defects, researchers are exploring the improvement of the bone regeneration efficacy of scaffolds through various approaches involving osteoconductive, osteoinductive, and angiogenic factors. In the current trend of research, there is also a suggestion that the topological factors of recent scaffolds may influence the attachment, migration, proliferation, and differentiation of bone cells. Building upon experimental confirmation of the effect of scaffold conformity with the defect site on enhanced bone regeneration in previous studies, we conducted this research to experimentally investigate the relationship between contact area with the defect site and bone regeneration efficacy. The results demonstrated that as the contact area of the scaffold increased, not only did the resistance to bone tissue growth increase, more significant bone regeneration also occurred, as evidenced through histological analysis and micro-CT analysis. This research confirms that the contact area between the scaffold and the defect site is a critical variable affecting bone regeneration efficacy, emphasizing its importance when designing customized scaffolds. This finding holds promising implications for future studies and applications in the field.

3.
Bioact Mater ; 31: 590-602, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37876874

RESUMO

To date, several off-the-shelf products such as artificial blood vessel grafts have been reported and clinically tested for small diameter vessel (SDV) replacement. However, conventional artificial blood vessel grafts lack endothelium and, thus, are not ideal for SDV transplantation as they can cause thrombosis. In addition, a successful artificial blood vessel graft for SDV must have sufficient mechanical properties to withstand various external stresses. Here, we developed a spontaneous cellular assembly SDV (S-SDV) that develops without additional intervention. By improving the dragging 3D printing technique, SDV constructs with free-form, multilayers and controllable pore size can be fabricated at once. Then, The S-SDV filled in the natural polymer bioink containing human umbilical vein endothelial cells (HUVECs) and human aorta smooth muscle cells (HAoSMCs). The endothelium can be induced by migration and self-assembly of endothelial cells through pores of the SDV construct. The antiplatelet adhesion of the formed endothelium on the luminal surface was also confirmed. In addition, this S-SDV had sufficient mechanical properties (burst pressure, suture retention, leakage test) for transplantation. We believe that the S-SDV could address the challenges of conventional SDVs: notably, endothelial formation and mechanical properties. In particular, the S-SDV can be designed simply as a free-form structure with a desired pore size. Since endothelial formation through the pore is easy even in free-form constructs, it is expected to be useful for endothelial formation in vascular structures with branch or curve shapes, and in other tubular tissues such as the esophagus.

4.
Colloids Surf B Biointerfaces ; 234: 113729, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38160475

RESUMO

Biofilms formed owing to the attachment of bacteria to surfaces have caused various problems in industries such as marine transportation/logistics and medicine. In response, many studies have been conducted on bactericidal surfaces, and nanostructured surfaces mimicking cicada and dragonfly wings are emerging as candidates for mechano-bactericidal surfaces. In specific circumstances involving mechano-bactericidal activity, certain nanostructured surfaces could exhibit their bactericidal effects by directly deforming the membranes of bacteria that adhere to these nanostructures. Additionally, in most cases, debris of bacterial cells may accumulate on these nanostructured surfaces. Such accumulation poses a significant challenge: it diminishes the mechano-bactericidal effectiveness of the surface, as it hinders the direct interaction between the nanostructures and any new bacteria that attach subsequently. In specific circumstances involving mechano-bactericidal activity, certain nanostructured surfaces could exhibit their bactericidal effects by directly deforming the membranes of bacteria that adhere to these nanostructures. Additionally, in most cases, debris of bacterial cells may accumulate on these nanostructured surfaces. Such accumulation poses a significant challenge: it diminishes the mechano-bactericidal effectiveness of the surface, as it hinders the direct interaction between the nanostructures and any new bacteria that attach subsequently.In other words, there is a need for strategies to remove the accumulated bacterial debris in order to sustain the mechano-bactericidal effect of the nanostructured surface. In this study, hierarchical micro/nano-structured surface (echinoid-shaped nanotextures were formed on Al micro-particle's surfaces) was fabricated using a simple pressure-less sintering method, and effective bactericidal efficiency was shown against E. coli (97 ± 3.81%) and S. aureus (80 ± 9.34%). In addition, thermal cleaning at 500 °C effectively eliminated accumulated dead bacterial debris while maintaining the intact Al2O3 nanostructure, resulting in significant mechano-bactericidal activity (E. coli: 89 ± 6.86%, S. aureus: 75 ± 8.31%). As a result, thermal cleaning maintains the intact nanostructure and allows the continuance of the mechano-bactericidal effect. This effect was consistently maintained even after five repetitive use (E. coli: 80 ± 16.26%, S. aureus: 76 ± 12.67%).


Assuntos
Nanoestruturas , Odonatos , Animais , Staphylococcus aureus/fisiologia , Escherichia coli , Nanoestruturas/química , Bactérias , Antibacterianos/farmacologia , Antibacterianos/química , Propriedades de Superfície
6.
Polymers (Basel) ; 14(24)2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36559894

RESUMO

In the use of the medical devices, it is essential to prevent the attachment of bacteria to the device surface or to kill the attached bacteria. To kill bacteria, many researchers have used antibiotics or studied nanostructure-based antibacterial surfaces, which rely on mechanical antibacterial methods. Several polymers are widely used for device fabrication, one of which is polycaprolactone (PCL). PCL is biocompatible, biodegradable, easy to fabricate using 3D printing, relatively inexpensive and its quality is easily controlled; therefore, there are various approaches to its use in bio-applications. In addition, it is an FDA-approved material, so it is often used as an implantable material in the human body. However, PCL has no inherent antibacterial function, so it is necessary to develop antibacterial functions in scaffold or film-based PCL medical devices. In this study, process parameters for nanopillar fabrication were established through a simple thermal imprinting method with PCL. Finally, a PCL film with a flexible and transparent nanopillar structure was produced, and the mechano-bactericidal potential was demonstrated using only one PCL material. PCL with nanopillars showed bactericidal ability against Escherichia coli (E. coli) and Bacillus subtilis (B. subtilis) bacteria cultured on its surface that resulted in membrane damage and death due to contact with nanopillars. Additionally, bacteriostatic results were shown to inhibit bacterial growth and activity of Staphylococcus aureus (S. aureus) on PCL nanostructured columns. The fabricated nanopillar structure has confirmed that mechanically induced antibacterial function and can be applied to implantable medical devices.

7.
Eur J Radiol ; 157: 110598, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36399872

RESUMO

OBJECTIVES: To evaluate tumor feeders, image quality, and performance of cone-beam computed tomography (CBCT) renal arteriography for renal tumor embolization. METHODS: Fifty-four patients with renal tumors were included in this study. The performance of CBCT renal arteriography was classified into three groups: group A, all tumor feeders could be confirmed solely based on the CBCT maximum intensity projection (MIP); group B, all feeders were detected in CBCT MIP, but there were some possible feeders which needed to be confirmed with selective digital subtraction angiography (DSA); and group C, tumor feeders were not detected in CBCT MIP, hence, the feeder was detected based on selective DSA. Tumor size, location, and enhancement on pre-procedure CT and tumor identification, overall image quality, breathing motion and opacification of the renal collecting system on CBCT MIP were also evaluated. RESULTS: There were 32 (59.2%) patients in group A, 15 (27.8%) patients in group B, and 7 (13.0%) patients in group C. Significant determining factors for performance of CBCT renal arteriography were age, tumor identification, overall image quality, and breathing motion (all p < 0.05). In six out of seven cases in group C, overall image quality deteriorated due to breathing motion (significant blurring of renal artery branches with difficulty in identifying the interlobar artery level). CONCLUSION: In most cases, CBCT renal arteriography was sufficient to detect tumor feeders for renal tumor embolization. However, additional selective DSA is required when the overall image quality deteriorates owing to the patient's motion.


Assuntos
Neoplasias Renais , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Tomografia Computadorizada de Feixe Cônico , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/terapia , Angiografia Digital , Artéria Renal
8.
ACS Appl Bio Mater ; 5(6): 3006-3012, 2022 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-35609304

RESUMO

Antibacterial surfaces are one of the most important surfaces in the medical and marine industries. Many researchers are studying antibacterial surfaces to kill bacteria or prevent adhesions. Various materials and structures are applied to the surface to inhibit the adhesion of bacteria or kill the adhered bacteria. Nowadays, a dual strategy is preferred rather than a single strategy. In this study, nanopillar structures were fabricated using polyethylene glycol dimethacrylate (PEGDMA), which has an antifouling effect. Afterward, the fabricated nanostructured PEGDMA was assessed to confirm the intrinsic antibacterial effect and mechanically induced antibacterial functions. The adhesion of Gram-negative and Gram-positive bacteria can be effectively reduced by the PEG hydration layer formation, steric repulsion, and flexible chain, and the nanostructure can damage the bacterial membrane. In addition, we performed antibacterial experiments on a nanopillar-structured surface made of PEGDMA. Furthermore, we revealed that the mechanical robustness of the nanopillared surface was superior to that of the nanocone-structured surface using computational analysis. Nanopillar structures fabricated using PEGDMA are promising candidates for antifouling and antibacterial surfaces and can be applied in various industries.


Assuntos
Aderência Bacteriana , Nanoestruturas , Antibacterianos/farmacologia , Bactérias , Metacrilatos , Nanoestruturas/química , Polietilenoglicóis/farmacologia , Propriedades de Superfície
9.
Sci Rep ; 12(1): 3732, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-35260689

RESUMO

The role of the gut microbiome in the development of renal stone diseases has not been well characterized. This study focused on the taxonomic and functional profiles of gut microbiomes according to the prevalence and incidence of nephrolithiasis. Stool samples from 915 Korean adults were collected at baseline. Participants were followed for a median of 4.0 years. We evaluated the biodiversity of the gut microbiota and taxonomic profiles associated with nephrolithiasis status, using 16S rRNA gene sequencing. Nephrolithiasis status was categorized into three groups: control (no-stone at both baseline and follow-up visits), incidental nephrolithiasis, and prevalent nephrolithiasis. Compared to the control and incidental nephrolithiasis, the prevalent nephrolithiasis showed a reduced evenness in alpha diversity. Nephrolithiasis was associated with a reduced abundance of some key taxa involved in short-chain fatty acid production. Moreover, the abundance of Bifidobacterium, which possess oxalate-degrading ability, was higher in the control. Conversely, there was no significant difference in the bacterial composition between the incidental and prevalent nephrolithiasis. In our study with repeated nephrolithiasis measurements, prevalent renal stones were associated with an altered gut microbiota composition compared to the control. Besides the known oxalate degradation pathway, other functional pathways inferred in this study require further investigation.


Assuntos
Microbioma Gastrointestinal , Cálculos Renais , Adulto , Feminino , Microbioma Gastrointestinal/genética , Humanos , Incidência , Cálculos Renais/metabolismo , Masculino , Oxalatos , Prevalência , RNA Ribossômico 16S/genética
10.
J Biomed Mater Res B Appl Biomater ; 110(5): 1103-1112, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34874103

RESUMO

This study evaluated 3D printed polycaprolactone (PCL) composite scaffold and recombinant human bone morphogenetic protein-2 (rhBMP-2), loaded either onto a PCL composite scaffold or implant surface, for vertical bone augmentation with implant placement. Three-dimensional printed PCL frames were filled with powdered PCL, hydroxyapatite, and ß-tricalcium phosphate. RhBMP-2 was loaded to the PCL composite scaffolds and implant surfaces, and rhBMP-2 release was quantified for 21 days. Experimental implants were placed bilaterally on 20 rabbit calvaria, and the PCL composite scaffolds were vertically augmented. The randomly allocated experimental groups were divided by carrier and rhBMP-2 dosage as no rhBMP-2 (control), 5 µg rhBMP-2 loaded to PCL composite (Scaffold/rhBMP-2[5 µg]), 5 µg rhBMP-2 loaded to implant (Implant/rhBMP-2[5 µg]), 30 µg rhBMP-2 loaded to PCL composite (Scaffold/rhBMP-2[30 µg]), and 30 µg rhBMP-2 loaded to implant (Implant/rhBMP-2[30 µg]). Histologic and histometric analyses were conducted after 8 weeks. In both scaffold-loading and implant-loading, rhBMP-2 released initially rapidly, then slowly and constantly. Released rhBMP-2 totaled 23.02 ± 1.03% and 24.69 ± 1.14% in the scaffold-loaded and implant-loaded groups, respectively. There were no significant differences in histologic bone-implant contact (%). Peri-implant bone density (%) was significantly higher in the Scaffold/rhBMP-2(30 µg) and Implant/rhBMP-2(30 µg) groups. Total bone density (%) was not significantly different between the Scaffold/rhBMP-2(5 µg), Implant/rhBMP-2(5 µg), and control groups, or between the Scaffold/rhBMP-2(30 µg) and Implant/rhBMP-2(30 µg) groups, but was significantly higher in the Scaffold/rhBMP-2(30 µg) and Implant/rhBMP-2(30 µg) groups than in the controls. Three-dimensional printed PCL composite scaffold with rhBMP-2 produced vertical osteogenesis and osseointegration, regardless of rhBMP-2 loading to the PCL composite scaffold or implant surface.


Assuntos
Proteína Morfogenética Óssea 2 , Fator de Crescimento Transformador beta , Animais , Humanos , Coelhos , Proteína Morfogenética Óssea 2/farmacologia , Regeneração Óssea , Osseointegração , Osteogênese , Poliésteres , Impressão Tridimensional , Proteínas Recombinantes/farmacologia , Crânio , Fator de Crescimento Transformador beta/farmacologia
11.
Int Neurourol J ; 26(4): 259-260, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36599333
12.
Polymers (Basel) ; 13(12)2021 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-34201327

RESUMO

The meniscus has poor intrinsic regenerative capability, and its injury inevitably leads to articular cartilage degeneration. Although there are commercialized off-the-shelf alternatives to achieve total meniscus regeneration, each has its own shortcomings such as individualized size matching issues and inappropriate mechanical properties. We manufactured a polycaprolactone-based patient-specific designed framework via a Computed Tomography scan images and 3D-printing technique. Then, we completed the hybrid-scaffold by combining the 3D-printed framework and mixture micro-size composite which consists of polycaprolactone and sodium chloride to create a cell-friendly microenvironment. Based on this hybrid-scaffold with an autograft cell source (fibrochondrocyte), we assessed mechanical and histological results using the rabbit total meniscectomy model. At postoperative 12-week, hybrid-scaffold achieved neo-meniscus tissue formation, and its shape was maintained without rupture or break away from the knee joint. Histological and immunohistochemical analysis results showed obvious ingrowth of the fibroblast-like cells and chondrocyte cells as well as mature lacunae that were embedded in the extracellular matrix. Hybrid-scaffolding resulted in superior shape matching as compared to original meniscus tissue. Histological analysis showed evidence of extensive neo-meniscus cell ingrowth. Additionally, the hybrid-scaffold did not induce osteoarthritis on the femoral condyle surface. The 3D-printed hybrid-scaffold may provide a promising approach that can be applied to those who received total meniscal resection, using patient-specific design and autogenous cell source.

13.
Biomed Mater ; 16(5)2021 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-34181586

RESUMO

The onlay-graft, one of the most difficult graft conditions, is used for diverse clinical conditions, including plastic and dental surgery. The graft should withstand continuous pressure from overlying tissues and have excellent bone formation capability in a limited bone contact situation. We recently developed a 3D printed Kagome-structured polycaprolactone (PCL) scaffold that has a stronger mechanical property. This study evaluated the clinical feasibility of this scaffold for onlay-graft use. The value of the scaffold containing recombinant human bone morphogenetic protein-2 in a hyaluronate-based hydrogel (rhBMP-2/HA) to enhance bone regeneration was also assessed. 3D-printed Kagome-PCL scaffolds alone (n= 12, group I) or loaded with rhBMP-2/HA (n= 12, group II) were grafted using a rat calvarial onlay-graft model. Following sacrifice at 2, 4, and 8 weeks, all 3D-printed Kagome-PCL scaffolds were accurately positioned and firmly integrated to the recipient bone. Micro-computed tomography and histology analyses revealed a constant height of the scaffolds over time in all animals. New bone grew into the scaffolds in both groups, but with greater volume in group II. These results suggest the promising clinical feasibility of the 3D-printed Kagome-PCL scaffold for onlay-graft use and it could substitute the conventional onlay-graft in the plastic and dental reconstructive surgery in the near future.


Assuntos
Proteína Morfogenética Óssea 2 , Ácido Hialurônico , Poliésteres , Impressão Tridimensional , Alicerces Teciduais/química , Fator de Crescimento Transformador beta , Animais , Proteína Morfogenética Óssea 2/química , Proteína Morfogenética Óssea 2/farmacologia , Regeneração Óssea/efeitos dos fármacos , Ácido Hialurônico/química , Ácido Hialurônico/farmacologia , Hidrogéis/química , Hidrogéis/farmacologia , Masculino , Poliésteres/química , Poliésteres/farmacologia , Ratos , Ratos Sprague-Dawley , Proteínas Recombinantes/química , Proteínas Recombinantes/farmacologia , Fator de Crescimento Transformador beta/química , Fator de Crescimento Transformador beta/farmacologia
14.
Int Neurourol J ; 25(1): 1-2, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33819960
15.
Polymers (Basel) ; 13(9)2021 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-33923079

RESUMO

In this study, we investigated the dual-pore kagome-structure design of a 3D-printed scaffold with enhanced in vitro cell response and compared the mechanical properties with 3D-printed scaffolds with conventional or offset patterns. The compressive modulus of the 3D-printed scaffold with the proposed design was found to resemble that of the 3D-printed scaffold with a conventional pattern at similar pore sizes despite higher porosity. Furthermore, the compressive modulus of the proposed scaffold surpassed that of the 3D-printed scaffold with conventional and offset patterns at similar porosities owing to the structural characteristics of the kagome structure. Regarding the in vitro cell response, cell adhesion, cell growth, and ALP concentration of the proposed scaffold for 14 days was superior to those of the control group scaffolds. Consequently, we found that the mechanical properties and in vitro cell response of the 3D-printed scaffold could be improved by kagome and dual-pore structures through DfAM. Moreover, we revealed that the dual-pore structure is effective for the in vitro cell response compared to the structures possessing conventional and offset patterns.

17.
Acta Radiol ; 62(9): 1229-1237, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32854526

RESUMO

BACKGROUND: Intractable bladder hemorrhage from pelvic malignancy can be potentially life-threatening and its management can be a challenging clinical problem. PURPOSE: To evaluate safety, efficacy, and clinical outcome of superselective vesical artery embolization for the control of intractable bladder hemorrhage from pelvic malignancy. MATERIAL AND METHODS: Between January 2010 and September 2018, 20 patients underwent superselective vesical artery embolization for intractable hematuria secondary to pelvic malignancy arising from or invading the bladder. Treatment details and clinical outcomes were obtained. RESULTS: There were 12 men and 8 women (mean age = 77 years). Bilateral embolization was performed in 10 patients and unilateral approach in 10 patients. Two patients died within four days after embolization due to underlying heart failure and systemic metastasis, respectively. The remaining 18 patients had a follow-up of >30 days. Bleeding was controlled after the first embolization in 17/18 patients and after a repeat embolization in the remaining one patient. The mean follow-up period of 18 patients was 10.6 months (range = 1-77 months). Late recurrent hemorrhage (≥ 30 days after embolization) was reported in 6 (33.3%) patients. Five of these six patients underwent repeat embolization. There were no major complications related to embolization. CONCLUSION: Palliative superselective vesical artery embolization is a feasible, effective, and safe procedure to control intractable hematuria in patients with pelvic malignancy.


Assuntos
Embolização Terapêutica/métodos , Hemorragia/etiologia , Hemorragia/terapia , Neoplasias Pélvicas/complicações , Bexiga Urinária/irrigação sanguínea , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Artérias/diagnóstico por imagem , Feminino , Hemorragia/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Bexiga Urinária/diagnóstico por imagem
18.
Int Neurourol J ; 24(Suppl 2): 104-110, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33271007

RESUMO

PURPOSE: Neurogenic bladder (NB) associated with spinal cord injury (SCI) is a serious health problem. However, no effective treatment has been developed for SCI patients with NB. Phosphatase and tensin homolog deleted on chromosome 10 (PTEN) inhibitors have been proposed as a promising option for inducing neural regeneration. Therefore, we investigated the effects of a tissue gene nerve (TGN), PTEN inhibitor, on voiding function, motor function, and the expression of growth factors after SCI. METHODS: In this experiment, female rats were randomly divided into 3 groups (n=10 in each group): the sham-operation group, the SCI-induced group, and the SCI-induced and TGN-treated group. Cystometry; the Basso, Beattie, and Bresnahan (BBB) scale test; the ladder walking test; hematoxylin and eosin staining; and Western blotting for brain-derived neurotrophic factor (BDNF), vascular endothelial growth factor (VEGF), and nerve growth factor (NGF) were performed to evaluate functional and molecular changes. RESULTS: After SCI, the rats exhibited decreased walking ability according to the BBB scale test and impaired coordinative function according to the ladder walking test. The PTEN inhibitor promoted enhanced walking ability and coordinative function. Cystometry showed voiding impairment after SCI and improved voiding function was observed after PTEN treatment. Overexpression of VEGF, BDNF, and NGF were observed after SCI. Administration of PTEN inhibitors significantly attenuated the overexpression of growth factors due to SCI. CONCLUSION: PTEN inhibitor treatment diminished the overexpression of growth factors and promoted the repair of damaged tissue. PTEN inhibitor-treated rats also showed improved motor function and improved voiding function. Therefore, we suggest TGN as a new therapeutic agent that can be applied after SCI.

19.
Int Neurourol J ; 24(3): 189-190, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33017889
20.
Polymers (Basel) ; 12(10)2020 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-32992820

RESUMO

Among 3D-printed composite scaffolds for bone tissue engineering, researchers have been attracted to the use of zinc ions to improve the scaffold's anti-bacterial activity and prevent surgical site infection. In this study, we assumed that the concentration of zinc ions released from the scaffold will be correlated with the thickness of the zinc oxide coating on 3D-printed scaffolds. We investigated the adequate thickness of zinc oxide coating by comparing different scaffolds' characteristics, antibacterial activity, and in vitro cell response. The scaffolds' compressive modulus decreased as the zinc oxide coating thickness increased (10, 100 and 200 nm). However, the compressive modulus of scaffolds in this study were superior to those of other reported scaffolds because our scaffolds had a kagome structure and were made of composite material. In regard to the antibacterial activity and in vitro cell response, the in vitro cell proliferation on scaffolds with a zinc oxide coating was higher than that of the control scaffold. Moreover, the antibacterial activity of scaffolds with 100 or 200 nm-thick zinc oxide coating on Escherichia coli was superior to that of other scaffolds. Therefore, we concluded that the scaffold with a 100 nm-thick zinc oxide coating was the most appropriate scaffold to use as a bone-regenerating scaffold, given its mechanical property, its antibacterial activity, and its in vitro cell proliferation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA