Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 544
Filtrar
1.
J Neuroinflammation ; 21(1): 115, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698374

RESUMO

BACKGROUND: Macrophages play a pivotal role in the regulation of Japanese encephalitis (JE), a severe neuroinflammation in the central nervous system (CNS) following infection with JE virus (JEV). Macrophages are known for their heterogeneity, polarizing into M1 or M2 phenotypes in the context of various immunopathological diseases. A comprehensive understanding of macrophage polarization and its relevance to JE progression holds significant promise for advancing JE control and therapeutic strategies. METHODS: To elucidate the role of NADPH oxidase-derived reactive oxygen species (ROS) in JE progression, we assessed viral load, M1 macrophage accumulation, and cytokine production in WT and NADPH oxidase 2 (NOX2)-deficient mice using murine JE model. Additionally, we employed bone marrow (BM) cell-derived macrophages to delineate ROS-mediated regulation of macrophage polarization by ROS following JEV infection. RESULTS: NOX2-deficient mice exhibited increased resistance to JE progression rather than heightened susceptibility, driven by the regulation of macrophage polarization. These mice displayed reduced viral loads in peripheral lymphoid tissues and the CNS, along with diminished infiltration of inflammatory cells into the CNS, thereby resulting in attenuated neuroinflammation. Additionally, NOX2-deficient mice exhibited enhanced JEV-specific Th1 CD4 + and CD8 + T cell responses and increased accumulation of M1 macrophages producing IL-12p40 and iNOS in peripheral lymphoid and inflamed extraneural tissues. Mechanistic investigations revealed that NOX2-deficient macrophages displayed a more pronounced differentiation into M1 phenotypes in response to JEV infection, thereby leading to the suppression of viral replication. Importantly, the administration of H2O2 generated by NOX2 was shown to inhibit M1 macrophage polarization. Finally, oral administration of the ROS scavenger, butylated hydroxyanisole (BHA), bolstered resistance to JE progression and reduced viral loads in both extraneural tissues and the CNS, along with facilitated accumulation of M1 macrophages. CONCLUSION: In light of our results, it is suggested that ROS generated by NOX2 play a role in undermining the control of JEV replication within peripheral extraneural tissues, primarily by suppressing M1 macrophage polarization. Subsequently, this leads to an augmentation in the viral load invading the CNS, thereby facilitating JE progression. Hence, our findings ultimately underscore the significance of ROS-mediated macrophage polarization in the context of JE progression initiated JEV infection.


Assuntos
Macrófagos , Camundongos Endogâmicos C57BL , Camundongos Knockout , NADPH Oxidase 2 , Animais , Camundongos , Macrófagos/metabolismo , Macrófagos/imunologia , Macrófagos/virologia , NADPH Oxidase 2/metabolismo , NADPH Oxidase 2/genética , Encefalite Japonesa/imunologia , Espécies Reativas de Oxigênio/metabolismo , Vírus da Encefalite Japonesa (Espécie) , Doenças Neuroinflamatórias/metabolismo , Doenças Neuroinflamatórias/imunologia , Doenças Neuroinflamatórias/virologia , Polaridade Celular/efeitos dos fármacos , Polaridade Celular/fisiologia
2.
Radiology ; 311(1): e233114, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38563667

RESUMO

Background Noninvasive diagnostic guidelines for hepatocellular carcinoma (HCC) vary across different global geographic areas, especially regarding criteria about gadoxetic acid-enhanced MRI. Purpose To compare the diagnostic performance of four different international HCC diagnosis guidelines and readers' judgment in diagnosing HCC using gadoxetic acid-enhanced MRI in patients at high risk for HCC. Materials and Methods This retrospective study included patients who had not undergone treatment, were at risk for HCC, and who underwent gadoxetic acid-enhanced MRI from January 2015 to June 2018 from 11 tertiary hospitals in South Korea. Four radiologists independently reviewed focal liver lesions (FLLs) according to four guidelines: American Association for the Study of Liver Diseases (AASLD)/Liver Imaging Reporting and Data System (LI-RADS), Korean Liver Cancer Association-National Cancer Center (KLCA-NCC), European Association for the Study of the Liver (EASL), and Asian Pacific Association for the Study of the Liver (APASL). Reader judgment (HCC or not HCC) was also recorded. Malignant FLLs were confirmed at pathology, and histologic and clinical follow-up data were used for benign FLLs. The guidelines' diagnostic performance was compared using generalized estimating equations. Additionally, the diagnostic odds ratio was assessed. Results A total of 2445 FLLs (median size, 27.4 mm) were analyzed in 2237 patients (mean age, 59 years ± 11 [SD]; 1666 male patients); 69.3% (1694 of 2445) were HCCs. KLCA-NCC showed the highest accuracy (80.0%; 95% CI: 78.7, 81.2; P = .001), with high sensitivity in Eastern guidelines (APASL, 89.1% [95% CI: 87.8, 90.3]; KLCA-NCC, 78.2% [95% CI: 76.6, 79.7]) and high specificity in Western guidelines (AASLD/LI-RADS, 89.6% [95% CI: 87.8, 91.2]; EASL, 88.1% [95% CI: 86.2, 89.9]) (P = .001). The diagnostic odds ratios were 20.7 (95% CI: 17.0, 25.3) for AASLD/LI-RADS, 18.9 (95% CI: 15.8, 22.6) for KLCA-NCC, 16.8 (95% CI: 13.8, 20.4) for EASL, and 8.9 (95% CI: 7.4, 10.7) for APASL. The readers' judgment demonstrated higher accuracy than that of the guidelines (accuracy, 86.0%; 95% CI: 84.9, 86.9; P = .001). Conclusion Among four different international HCC diagnosis guidelines, Eastern guidelines demonstrated higher sensitivity, whereas Western guidelines displayed higher specificity. KLCA-NCC achieved the highest accuracy, and AASLD/LI-RADS exhibited the highest diagnostic odds ratio. © RSNA, 2024 Supplemental material is available for this article.


Assuntos
Carcinoma Hepatocelular , Gadolínio DTPA , Neoplasias Hepáticas , Humanos , Masculino , Pessoa de Meia-Idade , Carcinoma Hepatocelular/diagnóstico por imagem , Estudos Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética
4.
Vet Med (Praha) ; 69(1): 30-34, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38464999

RESUMO

This retrospective case series describes the signalments, clinical signs, diagnostic test results, and postoperative complications obtained from the medical records of 10 client-owned dogs that underwent treatment for grade IV tracheal collapse using double-wire woven nitinol stents between October 2017 and September 2021. Respiratory signs resolved in all dogs immediately after tracheal stent placement. Mild to moderate stent fractures were identified in five dogs, of which two showed concurrent respiratory distress necessitating re-stenting after several months. Minor complications, such as stent migration, were absent. The double-wire woven nitinol stent optimised for the canine trachea showed favourable outcomes and minimal complications.

5.
Sci Rep ; 14(1): 7178, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38531959

RESUMO

Polyhexamethylene guanidine phosphate (PHMG-p) is a major component in humidifier disinfectants, which cause life-threatening lung injuries. However, to our knowledge, no published studies have investigated associations between PHMG-p dose and lung damage severity with long-term follow-up. Therefore, we evaluated longitudinal dose-dependent changes in lung injuries using repeated chest computed tomography (CT). Rats were exposed to low (0.2 mg/kg, n = 10), intermediate (1.0 mg/kg, n = 10), and high (5.0 mg/kg, n = 10) doses of PHMG-p. All rats underwent repeated CT scans after 10 and 40 weeks following the first exposure. All CT images were quantitatively analyzed using commercial software. Inflammation/fibrosis and tumor counts underwent histopathological evaluation. In both radiological and histopathologic results, the lung damage severity increased as the PHMG-p dose increased. Moreover, the number, size, and malignancy of the lung tumors increased as the dose increased. Bronchiolar-alveolar hyperplasia developed in all groups. During follow-up, there was intergroup variation in bronchiolar-alveolar hyperplasia progression, although bronchiolar-alveolar adenomas or carcinomas usually increase in size over time. Thirty-three carcinomas were detected in the high-dose group in two rats. Overall, lung damage from PHMG-p and the number and malignancy of lung tumors were shown to be dose-dependent in a rat model using repeated chest CT scans during a long-term follow-up.


Assuntos
Carcinoma , Lesão Pulmonar , Neoplasias Pulmonares , Ratos , Animais , Seguimentos , Carcinógenos , Hiperplasia , Guanidinas , Carcinogênese
6.
Front Oncol ; 14: 1349632, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38352890

RESUMO

Purpose: The purpose of this study is to elucidate the patterns of recurrence of hepatocellular carcinoma and to analyze factors that can predict recurrence after complete response to radioembolization. Materials and methods: A total of 289 consecutive patients who underwent radioembolization for the treatment of hepatocellular carcinoma at a single tertiary center were retrospectively reviewed. Baseline characteristics were collected and compared between the group showing complete response and the group showing noncomplete response. Data on recurrence status, time to recurrence, and the patterns of recurrence among the patients who showed radiologic complete response were collected. The group that maintained complete response and the group that experienced recurrence were compared, and the risk factors affecting recurrence were evaluated by logistic regression analysis. Results: The complete response rate was 24.9% (73/289). Age, sex, tumor markers, maximum tumor diameter, multiplicity, presence of vascular invasion, and target radiation dose were significantly different between the complete response and noncomplete response groups. The recurrence rate after complete response was 38.4% (28/73), and 67.9% (19/28) of recurrences occurred by 8 months after complete response. Eight patients who underwent resection/transplantation after complete response experienced no recurrence. Multiple tumors and a lower target radiation dose were independent risk factors of recurrence after complete response in the multivariate logistic regression. Conclusion: Hepatocellular carcinoma recurrence following complete response after radioembolization is not uncommon and frequently occurs within 1 year after complete response. Multiple tumors and a lower target radiation dose may be risk factors for recurrence.

7.
Vet Anim Sci ; 23: 100341, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38389862

RESUMO

This study aimed to evaluate fatigue of three stent designs when various forces are applied and perform a comparative analyses. A computer simulation using the finite element method was performed. In particular, we constructed a three-dimensional finite element model of nitinol stents with three designs (S6: single-woven wire, wire diameter: 0.006 inch; D6: double-woven wire, wire diameter: 0.006 inch, and D7: double-woven wire, wire diameter: 0.007 inch) that are used to treat canine tracheal collapse (TC). The stents were subjected to a 200 mmHg compression force, a pure torsion force in a perpendicular direction, and a bending-torsion force combining perpendicular and axial forces. The von Mises stress was calculated to evaluate the extent of stent displacement, and Goodman diagrams were plotted to compare fatigue life cycles. D7 exhibited a longer fatigue life compared to S6 and D6. Under compression, pure torsion, and bending-torsion forces, displacement was the smallest for D7, followed by D6 and S6. Similarly, the fatigue life was the longest for D7, followed by D6 and S6. S6 showed the greatest displacement when subjected to external forces; among stents designed using the same wire, D6 displayed less displacement than S6, and D7 exhibited superior fatigue life when subjected to varying degrees of force. This study showed that the structural stability and fatigue life of stents could be effectively compared using finite element method D7 has the greatest stability and structural rigidity under cyclic load.

8.
Neurogastroenterol Motil ; 36(4): e14736, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38225864

RESUMO

BACKGROUND: Previous studies have demonstrated that 50% of patients with normal high-resolution manometry (HRM) findings or ineffective esophageal motility (IEM) may have abnormal functional luminal imaging probe (FLIP) results. However, the specific HRM findings associated with abnormal FLIP results are unknown. Herein, we investigated the relationship between nonspecific manometry findings and abnormal FLIP results. METHODS: We retrospectively analyzed 684 patients who underwent HRM at a tertiary care center in Seoul, Korea, based on the Chicago Classification version 4.0 protocol. KEY RESULTS: Among the 684 patients, 398 had normal HRM findings or IEM. Of these 398 patients, eight showed esophageal wall thickening on endoscopic ultrasonography or computed tomography; however, no abnormalities were seen during esophagogastroduodenoscopy. Among these eight patients, seven showed repetitive simultaneous contractions (RSCs) in at least one of the two positions: 61% (±29%) in 10 swallows in the supine position and 51% (±30%) in five swallows in the upright position. Four patients who underwent FLIP had a significantly decreased esophagogastric junction distensibility index (1.0 ± 0.5 m m 2 mmHg - 1 at 60 mL). Two of these patients underwent per-oral endoscopic myotomy (POEM) due to a lack of response to medication. Esophageal muscle biopsy revealed hypertrophic muscle with marginal eosinophil infiltration. CONCLUSIONS & INFERENCES: A subset of patients (2%) with normal HRM findings or IEM and RSCs experienced dysphagia associated with poor distensibility of the thickened esophageal wall. FLIP assessment or combined HRM and impedance protocols may help better define these patients who may respond well to POEM.


Assuntos
Transtornos de Deglutição , Transtornos da Motilidade Esofágica , Humanos , Transtornos de Deglutição/diagnóstico , Transtornos da Motilidade Esofágica/complicações , Transtornos da Motilidade Esofágica/diagnóstico , Transtornos da Motilidade Esofágica/patologia , Estudos Retrospectivos , Manometria/métodos
9.
Cancer Res Treat ; 56(1): 247-258, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37605535

RESUMO

PURPOSE: Clinical prognostic criteria using preoperative factors were not developed for post-neoadjuvant therapy (NAT) surgery of pancreatic ductal adenocarcinoma (PDAC). We aimed to identify preoperative factors associated with overall survival (OS) in PDAC patients who underwent post-NAT curative-intent surgery and develop risk stratification criteria. MATERIALS AND METHODS: Consecutive PDAC patients who underwent post-NAT curative-intent surgeries between 2007 and 2020 were retrospectively analyzed. Demographic, laboratory, surgical, and histopathologic variables were collected. Baseline, preoperative, and interval changes of computed tomography (CT) findings proposed by the Society of Abdominal Radiology and the American Pancreatic Association were analyzed. Cox proportional hazard analysis was used to select preoperative variables associated with OS. We developed risk stratification criteria composed of the significant preoperative variables, i.e., post-NAT response criteria. We compared the discrimination performance of post-NAT response criteria with that of post-NAT pathological (yp) American Joint Cancer Committee TNM staging system. RESULTS: One hundred forty-five PDAC patients were included. Stable or increased tumor size on CT (hazard ratio [HR], 2.58; 95% confidence interval [CI], 1.58 to 4.21; p < 0.001) and elevated preoperative carbohydrate antigen 19-9 (CA19-9) level (HR, 1.98; 95% CI, 1.11 to 3.55; p=0.021) were independent factors of OS. The OS of the patient groups stratified by post-NAT response criteria which combined changes in tumor size and CA19-9 showed significant difference (p < 0.001). Such stratification was comparable to ypTNM staging in discrimination performance (difference of C-index, 0.068; 95% CI, -0.012 to 0.142). CONCLUSION: "Any degree of decrease in tumor size on CT" and CA19-9 normalization or staying normal were independent favorable factors of OS. The combination of the two factors discriminated OS comparably to ypTNM staging.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Estudos Retrospectivos , Antígeno CA-19-9 , Terapia Neoadjuvante , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/tratamento farmacológico , Carcinoma Ductal Pancreático/cirurgia , Prognóstico , Medição de Risco
10.
Eur Radiol ; 34(3): 1502-1514, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37656177

RESUMO

OBJECTIVE: We performed an updated meta-analysis to determine the diagnostic performance of Liver Imaging Reporting and Data System (LI-RADS, LR) 5 category for hepatocellular carcinoma (HCC) using LI-RADS version 2018 (v2018), and to evaluate differences by imaging modalities and type of MRI contrast material. METHODS: The MEDLINE and Embase databases were searched for studies reporting the performance of LR-5 using v2018 for diagnosing HCC. A bivariate random-effects model was used to calculate the pooled per-observation sensitivity and specificity. Subgroup analysis was performed based on imaging modalities and type of MRI contrast material. RESULTS: Forty-eight studies qualified for the meta-analysis, comprising 9031 patients, 10,547 observations, and 7216 HCCs. The pooled per-observation sensitivity and specificity of LR-5 for diagnosing HCC were 66% (95% CI, 61-70%) and 91% (95% CI, 89-93%), respectively. In the subgroup analysis, MRI with extracellular agent (ECA-MRI) showed significantly higher pooled sensitivity (77% [95% CI, 70-82%]) than CT (66% [95% CI, 58-73%]; p = 0.023) or MRI with gadoxetate (Gx-MRI) (65% [95% CI, 60-70%]; p = 0.001), but there was no significant difference between ECA-MRI and MRI with gadobenate (gadobenate-MRI) (73% [95% CI, 61-82%]; p = 0.495). Pooled specificities were 88% (95% CI, 80-93%) for CT, 92% (95% CI, 86-95%) for ECA-MRI, 93% (95% CI, 91-95%) for Gx-MRI, and 91% (95% CI, 84-95%) for gadobenate-MRI without significant differences (p = 0.084-0.803). CONCLUSIONS: LI-RADS v2018 LR-5 provides high specificity for HCC diagnosis regardless of modality or contrast material, while ECA-MRI showed higher sensitivity than CT or Gx-MRI. CLINICAL RELEVANCE STATEMENT: Refinement of the criteria for improving sensitivity while maintaining high specificity of LR-5 for HCC diagnosis may be an essential future direction. KEY POINTS: • The pooled per-observation sensitivity and specificity of LR-5 for diagnosing HCC using LI-RADSv2018 were 66% and 91%, respectively. • ECA-MRI showed higher sensitivity than CT (77% vs 66%, p = 0.023) or Gx-MRI (77% vs 65%, p = 0.001). • LI-RADS v2018 LR-5 provides high specificity (88-93%) for HCC diagnosis regardless of modality or contrast material type.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Compostos Organometálicos , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Meios de Contraste/farmacologia , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade , Meglumina , Quelantes
13.
BMC Infect Dis ; 23(1): 855, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38057704

RESUMO

BACKGROUND: Amid the COVID-19 pandemic, extensive testing was undertaken by independent clinical laboratories (ICLs), yet limited research exists on this matter. Drawing from Green Cross Laboratories (GC Labs)' pandemic response experience, this study seeks to offer insights for preparation for the next pandemic. METHODS: This retrospective study analyzed the outcomes of SARS-CoV-2 real-time reverse transcription polymerase chain reaction (SARS-CoV-2 rRT PCR) tests administered by GC Labs for COVID-19 diagnosis, upon request by different organizations, between February 2020 and April 2022. The distribution of institutions that requested the tests, the type of tests, and the positive rate were analyzed. We investigated resource allocation details. RESULTS: ICLs were responsible for conducting 85.6% of all tests carried out under South Korea's COVID-19 testing policy during the pandemic. The availability of free testing regardless of symptoms led to a significant increase in the use of pooled tests, which accounted for more than 80% of all tests conducted after August 2021. The gender and age distribution of COVID-19 cases nationwide and GC Labs' positive cases were similar. When we analyzed the positive rate by requesting organizations during the COVID-19 pandemic, despite an overall nationwide positivity rate of 35%, high-risk facilities exhibited a positivity rate of less than 5% by maintaining preemptive testing. The most notable increase in resources during the pandemic was seen in human resource input. CONCLUSIONS: South Korea's ICLs were able to conduct large volumes of testing during the COVID-19 pandemic because of their logistics and computer systems, scalable testing space, and trained testing personnel. They also had the flexibility to bring in additional resources to expand testing capacity because they are specialized testing organizations. Hence, ICLs could execute the pooled test that the government had introduced for extensive general population screening. The preemptive periodic testing of high-risk populations kept the positive rate much lower than in the general population. This study's findings will aid in refining mass testing-based policies for the next pandemic.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , COVID-19/epidemiologia , Teste para COVID-19 , SARS-CoV-2 , Laboratórios Clínicos , Pandemias/prevenção & controle , Estudos Retrospectivos , Técnicas de Laboratório Clínico , República da Coreia/epidemiologia
14.
Orthod Craniofac Res ; 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38058275

RESUMO

OBJECTIVES: To investigate the internal structure of the nasomaxillary complex, including the maxillary sinus, nasal cavity and nasal septum according to the facial asymmetry pattern and to evaluate its correlation with external maxillomandibular asymmetry in Class III patients based on cone-beam computerized tomography (CBCT) images. MATERIALS AND METHODS: Facial asymmetry was analysed in a total of 100 Class III patients aged 16 years or older using CBCT scans. Patients were categorized into subgroups based on asymmetry pattern. Measurements of the nasomaxillary complex were obtained from the CBCT scans, including the volume and width of the maxillary sinuses and nasal cavities on deviated and non-deviated sides, as well as the displacement of the nasal septum. Statistical analysis was performed to compare the internal nasomaxillary variables within and between groups, and regression analysis was conducted to evaluate the correlation between facial asymmetry and the internal nasomaxillary variables. RESULTS: Group comparisons showed that there were no significant differences in the volume of the maxillary sinus and nasal cavity. However, the direction and extent of nasal septum deviation, as well as the width of the nasal cavity, varied depending on the maxillary asymmetry pattern. Regression analysis indicated a correlation between nasal septum deviation and the difference in maxillary height, while the difference in nasal cavity width was correlated with the difference in maxillary width. CONCLUSION: A comprehensive evaluation of the internal nasal anatomy is vital for understanding the intricate relationship between nasal structure and maxillary growth.

15.
JMIR Mhealth Uhealth ; 11: e50663, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38054461

RESUMO

Background: Physical activity plays a crucial role in maintaining a healthy lifestyle, and wrist-worn wearables, such as smartwatches and smart bands, have become popular tools for measuring activity levels in daily life. However, studies on physical activity using wearable devices have limitations; for example, these studies often rely on a single device model or use improper clustering methods to analyze the wearable data that are extracted from wearable devices. Objective: This study aimed to identify methods suitable for analyzing wearable data and determining daily physical activity patterns. This study also explored the association between these physical activity patterns and health risk factors. Methods: People aged >30 years who had metabolic syndrome risk factors and were using their own wrist-worn devices were included in this study. We collected personal health data through a web-based survey and measured physical activity levels using wrist-worn wearables over the course of 1 week. The Time-Series Anytime Density Peak (TADPole) clustering method, which is a novel time-series method proposed recently, was used to identify the physical activity patterns of study participants. Additionally, we defined physical activity pattern groups based on the similarity of physical activity patterns between weekdays and weekends. We used the χ2 or Fisher exact test for categorical variables and the 2-tailed t test for numerical variables to find significant differences between physical activity pattern groups. Logistic regression models were used to analyze the relationship between activity patterns and health risk factors. Results: A total of 47 participants were included in the analysis, generating a total of 329 person-days of data. We identified 2 different types of physical activity patterns (early bird pattern and night owl pattern) for weekdays and weekends. The physical activity levels of early birds were less than that of night owls on both weekdays and weekends. Additionally, participants were categorized into stable and shifting groups based on the similarity of physical activity patterns between weekdays and weekends. The physical activity pattern groups showed significant differences depending on age (P=.004) and daily energy expenditure (P<.001 for weekdays; P=.003 for weekends). Logistic regression analysis revealed a significant association between older age (≥40 y) and shifting physical activity patterns (odds ratio 8.68, 95% CI 1.95-48.85; P=.007). Conclusions: This study overcomes the limitations of previous studies by using various models of wrist-worn wearables and a novel time-series clustering method. Our findings suggested that age significantly influenced physical activity patterns. It also suggests a potential role of the TADPole clustering method in the analysis of large and multidimensional data, such as wearable data.


Assuntos
Síndrome Metabólica , Dispositivos Eletrônicos Vestíveis , Humanos , Adulto , Síndrome Metabólica/epidemiologia , Exercício Físico , Punho , Análise por Conglomerados
16.
Cancer Imaging ; 23(1): 126, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38111054

RESUMO

OBJECTIVES: To assess the resectability of pancreatic ductal adenocarcinoma (PDAC), the evaluation of tumor vascular contact holds paramount significance. This study aimed to compare the image quality and diagnostic performance of high-resolution (HR) pancreas computed tomography (CT) using an 80 kVp tube voltage and a thin slice (1 mm) for assessing PDAC resectability, in comparison with the standard protocol CT using 120 kVp. METHODS: This research constitutes a secondary analysis originating from a multicenter prospective study. All participants underwent both the standard protocol pancreas CT using 120 kVp with 3 mm slice thickness (ST) and HR-CT utilizing an 80 kVp tube voltage and 1 mm ST. The contrast-to-noise ratio (CNR) between parenchyma and tumor, along with the degree of enhancement of the abdominal aorta and main portal vein (MPV), were measured and subsequently compared. Additionally, the likelihood of margin-negative resection (R0) was evaluated using a five-point scale. The diagnostic performance of both CT protocols in predicting R0 resection was assessed through the area under the receiver operating characteristic curve (AUC). RESULTS: A total of 69 patients (37 males and 32 females; median age, 66.5 years) were included in the study. The median CNR of PDAC was 10.4 in HR-CT, which was significantly higher than the 7.1 in the standard CT (P=0.006). Furthermore, HR-CT demonstrated notably higher median attenuation values for both the abdominal aorta (579.5 HU vs. 327.2 HU; P=0.002) and the MPV (263.0 HU vs. 175.6 HU; P=0.004) in comparison with standard CT. Following surgery, R0 resection was achieved in 51 patients. The pooled AUC for HR-CT in predicting R0 resection was 0.727, slightly exceeding the 0.699 of standard CT, albeit lacking a significant statistical distinction (P=0.128). CONCLUSION: While HR pancreas CT using 80 kVp offered a notably greater degree of contrast enhancement in vessels and a higher CNR for PDAC compared to standard CT, its diagnostic performance in predicting R0 resection remained statistically comparable.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Idoso , Feminino , Humanos , Masculino , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/cirurgia , Meios de Contraste , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/patologia , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Estudos Multicêntricos como Assunto
17.
RSC Adv ; 13(45): 31873-31880, 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37915448

RESUMO

Olivine-type LiFePO4 (LFP) is considered a promising cathode material for lithium-ion batteries (LIBs) owing to its abundance, high specific capacity, and cycling performance. However, its poor electronic and ionic transportation properties degrade the high rate capability, which limits its use in high-energy-density LIBs for applications such as electric vehicles. Therefore, in this study, we propose a modification of the anion configuration through nitrogen substitution using ion implantation to improve electronic and ionic transport during lithiation/delithiation. We found that nitrogen substitution at the oxygen sites effectively improved the electrochemical properties through surface modification and charge-transfer kinetics. In particular, the increased amount of nitrogen substitution at the surface regions resulted in reduced ionic and electronic resistances. These modified characteristics led to a remarkable rate capability with a high capacity (128.2 mA h g-1 at 10C). We expect that these modified anion effects on the electrochemical properties can be effective in the design of cathode materials for LIBs.

18.
J Craniofac Surg ; 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37938102

RESUMO

Contouring surgery is an operation that makes a smooth, oval-shaped face by removing protruding parts of the face. In particular, mandibuloplasty is a procedure that softens the shape of the mandible and is a popular procedure among Asians with a dominant mesocephalic profile. In this study, we tried to discuss the considerations before surgery by dividing the mandibular shape into morphologic aspects in the lateral and frontal views and anatomic considerations. In the lateral view, it is essential to consider the posterior ramal height and mandibular body length of each patient. These factors are closely related to the postoperative outcomes. Consideration of the mandibular plane angle is also essential. In the frontal view, the position of the gonial angle relative to the ramal body should be considered because the position of the gonial angle can affect the difficulty of operation. Anatomic considerations include antero-posterior ramal width, bucco-lingual width of mandibular body, amount of mouth opening, and location of inferior alveolar nerve. These are important factors that determine the difficulty of the operation. In this study, classification according to the shape and shape of the mandible was presented, and considerations for each classification were discussed. Cosmetic surgery is a socio-psychologically meaningful procedure that not only improves the esthetics but also improves the mental well-being of the patients. Therefore, it will be possible to provide better medical services to patients if clinicians are fully aware of the factors that can increase the difficulty of the operation and the factors that affect the surgical outcome.

20.
Sci Rep ; 13(1): 17135, 2023 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-37816861

RESUMO

This study aimed to evaluate the difference in expansion patterns based on the position of miniscrews for a tissue-bone-borne palatal C-expander using a finite element method. Ten expansion models were examined, each representing a different position of miniscrews on the palate. Models A and B had miniscrews symmetrically placed 7 mm and 15 mm below the cementoenamel junction (CEJ), respectively. Models C to J had miniscrews positioned in a triangular manner at 7 mm and 15 mm below CEJ. Stress, displacement, angular changes of the bone and teeth, and changes in the nasomaxillary complex were measured using elastoplastic behavior models through static-nonlinear simulation employing an implicit method. The anterior and posterior parts of paramidpalatal suture area were identified as ANT, TPS-M, and TPS-L, and their ratio was assessed. Model A, which featured three miniscrews located 7 mm below the CEJ, exhibited the least molar inclination and the smallest amount of skeletal expansion. Model I, with two miniscrews placed between the first and second molars, demonstrated the greatest lateral displacement at point N on the nasal cavity wall, along with the smallest ratio of ANT to TPS-M or TPS-L. This finding suggests that the posterior expansion of the palate in relation to the anterior expansion was maximized. The results of this study indicate that strategic positioning of miniscrews is effective in achieving various expansion patterns based on the targeted correction areas within the nasomaxillary complex.


Assuntos
Maxila , Dente , Maxila/cirurgia , Análise de Elementos Finitos , Palato/cirurgia , Dente Molar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA