Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Infect Disord Drug Targets ; 23(1): e160822207524, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35975857

RESUMO

BACKGROUND: We diagnosed various cases of rhino-orbital-cerebral- COVID-associated Mucormycosis (ROCM-CAM) during India's second wave of COVID-19. This helped formulate novel suggestions for improving laboratory output, applicable anywhere in the world. METHODS: To diagnose ROCM-CAM by microbiological methods, we used direct microscopy and conventional culture on various clinical samples within the shortest turn-around time. DESIGN: Prospective single-center observational study. PARTICIPANTS: Patients with ROCM-CAM. RESULTS: Of 113 suspected cases of ROCM-CAM during May 2021, direct microscopy and culture could confirm the disease in 87.61% and 44.25% of patients, respectively. The highest pathogen isolation was seen from maxillary bone fragments, FESS-guided biopsy from pterygopalatine fossae, nasal turbinates and nasal mucosal biopsy. Direct microscopy could diagnose the disease in almost 40% of patients within 24 hours and 60% within two days. Conventional cultures yielded Rhizopus spp. (86%) as the commonest fungal pathogen followed by Mucor spp. (12%) within 7 days. Deep tissue biopsies are more useful for rapid diagnosis than superficial specimens. Routine fungal cultures can supplement case detection and help prognosticate survivors. CONCLUSION: The management of ROCM is a surgical emergency. The diagnosis of the condition must therefore be prompt and precise. Despite ongoing antifungal therapy, nasal mucosal tissue, FESSguided, and intra-operative tissue biopsies showed the pathogen's highest diagnostic yield. The diagnostic index improved further when multiple (4-5) high-quality specimens were collected. Nasal swabs and crusts, among the most commonly requested specimens worldwide, were found to have an overall low diagnostic potential.


Assuntos
COVID-19 , Mucormicose , Humanos , Mucormicose/diagnóstico , Estudos Prospectivos , COVID-19/diagnóstico , Biópsia , Antifúngicos/uso terapêutico , Teste para COVID-19
2.
J Thorac Cardiovasc Surg ; 135(3): 512-20, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18329462

RESUMO

OBJECTIVE: Cerebral microembolization is a well-recognized phenomenon after cardiac valve replacement, but the relative proportion of solid and gaseous emboli is uncertain. Particulate microemboli are thought to be the most damaging. With the use of multifrequency transcranial Doppler ultrasound, we compared the number and nature of microemboli in recipients of biologic and mechanical aortic valve prostheses. METHODS: The middle cerebral arteries of 60 patients were monitored bilaterally with a new-generation transcranial Doppler ultrasound (Embo-Dop, DWL Elektronische Systeme GmbH, Singen, Germany) that rejects artefacts online and automatically discriminates between solid and gaseous microemboli. All recordings were performed during a 30-minute period 1 day before and at a mean of 5 days and 3 months after isolated aortic valve replacement with a biologic (30, group B) or mechanical (30, group M) prosthesis. RESULTS: The patients in group B were older, with a mean age of 70.6 +/- 9.7 years versus 55.4 +/- 9.4 years (P < .005) in the patients in group M. Biologic prosthesis recipients were all taking aspirin (no warfarin); patients with mechanical valves were well anticoagulated with warfarin both 5 days and 3 months after surgery. None of the patients had solid microemboli preoperatively. Five days postoperatively, the absolute number of cerebral microemboli was 145 and 594 for total microemboli (P = .001) and 41 and 182 for solid microemboli (P = .002) in groups B and M, respectively. At 3 months, the absolute number was 65 and 608 for total microemboli (P < .001) and 10 and 188 for solid microemboli (P < .001) in groups B and M, respectively. Solid microemboli accounted for 16% of the total microembolic load in group B compared with 31% in group M (P = .05) at 3 months. CONCLUSIONS: Solid cerebral microemboli represent approximately one third of the total cerebral microembolic load after mechanical aortic valve replacement and are detectable in the majority of such patients both 5 days and 3 months after surgery. The neurofunctional consequences of this phenomenon should be carefully assessed.


Assuntos
Bioprótese/efeitos adversos , Embolia Aérea/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Ultrassonografia Doppler Transcraniana , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Estudos de Coortes , Embolia Aérea/etiologia , Embolia Aérea/mortalidade , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Mortalidade Hospitalar/tendências , Humanos , Embolia Intracraniana/mortalidade , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/métodos , Cuidados Pré-Operatórios/métodos , Probabilidade , Estudos Prospectivos , Medição de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Análise de Sobrevida , Resultado do Tratamento , Reino Unido/epidemiologia
3.
J Am Coll Cardiol ; 50(11): 1047-53, 2007 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-17825713

RESUMO

OBJECTIVES: Our purpose was to examine the impact of diabetes mellitus (DM) on vasoreactivity and endothelial function of radial artery (RA) grafts ex vivo. BACKGROUND: The arteriopathy associated with DM may influence the surgeon's choice of conduits for revascularization. Arterial conduits and especially the RA are prone to vasospasm in the perioperative period. METHODS: The study population consisted of 98 patients with coronary artery disease undergoing coronary artery bypass grafting by using RA grafts. The maximum contractions of RA segments induced by K+ (66 mmol/l) and clinically important vasoconstrictors such as adrenaline (5 x 10(-5) mol/l), angiotensin II (10(-6) mol/l), and prostaglandin F2alpha (PGF2alpha) (10(-6) mol/l) were recorded. Relaxation of RA rings to carbachol (10(-4) mol/l) was used as a measure of endothelial function. Multivariate analysis was then applied to determine the role of clinical characteristics on the vasomotor responses to these agents. RESULTS: Vessels from patients with DM had greater contractions in response to adrenaline (p < 0.05), angiotensin (p < 0.05), and PGF2alpha (p < 0.01) compared with non-DM vessels, despite the similar vasoconstrictions induced by high K+ (p = NS). Diabetes mellitus was also associated with smaller vasorelaxations in response to carbachol (p < 0.001). In multivariate analysis, DM was an independent predictor of RA contractions in response to adrenaline (beta [SE] 3.085 [1.410], p = 0.031), angiotensin II (beta [SE] 3.838 [1.552], p = 0.015), and PGF2alpha (beta [SE] 4.609 [1.908], p = 0.018) but not K+ (p = NS). Diabetes mellitus was also independently associated with the vasorelaxations in response to carbachol (beta [SE] -15.645 [2.622], p = 0.0001). CONCLUSIONS: Diabetes mellitus is associated with impaired endothelial function and greater contractions of RA grafts in response to all of the clinically relevant vasoconstrictors. These findings suggest that the RA of diabetic patients may be more prone to spasm in response to endogenous vasoconstrictors, an observation with important implications for surgeons' choice of conduits in this cohort of patients.


Assuntos
Complicações do Diabetes/fisiopatologia , Artéria Radial/fisiopatologia , Vasoconstrição/fisiologia , Vasodilatação/fisiologia , Estudos de Casos e Controles , Ponte de Artéria Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Complicações do Diabetes/complicações , Complicações do Diabetes/cirurgia , Endotélio Vascular/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Técnicas de Cultura de Tecidos
4.
J Thorac Cardiovasc Surg ; 133(2): 485-93, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17258587

RESUMO

OBJECTIVES: Intraoperative cerebral microembolism is a cause of cerebral dysfunction after cardiac surgery, and particulate microemboli are the most damaging. Using a new-generation transcranial Doppler ultrasound, we compared the number and nature of microemboli in patients undergoing off-pump coronary artery bypass grafting during performance of proximal anastomoses with three techniques: an aortic side-biting clamp and two clampless devices (the Enclose II device [Novare Surgical Systems, Inc, Cupertino, Calif] and the Heartstring II device [Guidant Corporation, Santa Clara, Calif]) developed to obviate the need for an aortic side-biting clamp, thereby reducing the number of cerebral microemboli. METHODS: Bilateral continuous monitoring of the middle cerebral arteries was performed with a multirange, multifrequency transcranial Doppler device that both automatically rejects artifacts online and discriminates between solid and gaseous microemboli. Recordings were continuously undertaken during performance of 66 proximal aortic anastomoses in 42 patients. Thirty-five anastomoses were performed with an aortic side-biting clamp, 20 with the Enclose device, and 11 the Hearstring device. RESULTS: Most microemboli occurred during application/insertion and removal of each device from the ascending aorta. The median number (interquartile range) of total microemboli was 11 (6-32) during side clamping, 11 (6-15) with the Enclose device, 40 (31-48) with the Heartstring device (P < .01). The proportion of solid microemboli was significantly higher in the side-clamp group (23%) compared with 6% and 1% in the Enclose and Heartstring groups, respectively (P < .01). CONCLUSIONS: Avoidance of aortic side clamping results in a significant reduction in the proportion of solid microemboli detected with transcranial Doppler. As solid microemboli are probably the most damaging, use of the Enclose and Heartstring devices may represent an important strategy for minimizing cerebral injury during proximal aortic anastomoses.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Estenose Coronária/cirurgia , Embolia Aérea/prevenção & controle , Embolia Intracraniana/prevenção & controle , Complicações Intraoperatórias/prevenção & controle , Idoso , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/instrumentação , Angiografia Coronária , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Embolia Aérea/diagnóstico por imagem , Embolia Aérea/etiologia , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Complicações Intraoperatórias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Probabilidade , Prognóstico , Estudos Prospectivos , Valores de Referência , Medição de Risco , Instrumentos Cirúrgicos , Taxa de Sobrevida , Resultado do Tratamento , Ultrassonografia Doppler Transcraniana
5.
J Thorac Cardiovasc Surg ; 130(2): 315-20, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16077393

RESUMO

BACKGROUND: Intraoperative graft patency assessment during coronary artery bypass grafting enables detection and immediate correction of graft failure. Currently transit-time flowmetry is used to assess graft patency on the basis of mean graft flow and derived values, such as the pulsatility index. Intraoperative fluorescence imaging, based on the fluorescence of indocyanine green dye, provides direct visual images to confirm graft patency. METHODS: We performed a prospective observational study to assess intraoperative graft patency in patients undergoing coronary artery bypass grafting, by using an intraoperative fluorescence imaging system (SPY) and transit-time flowmetry (BF 2004). Poor flow with the intraoperative fluorescence imaging system was defined if there was an absence of fluorescence or if it did not appear within 15 seconds in the graft. A persistent mean graft flow value less than 5 mL/min and a pulsatility index greater than 5 with transit-time flowmetry were considered unacceptable and prompted graft revision. RESULTS: We assessed the intraoperative patency of 266 grafts in 100 coronary artery bypass grafting patients. Intraoperative fluorescence imaging and transit-time flowmetry confirmed adequate flow in 241 (91%) grafts in 75 patients (75%). Transient poor flow was detected with both intraoperative fluorescence imaging and transit-time flowmetry in 7 (2.6%) grafts in 7 (7%) patients. This subsequently proved to be adequate on repeat testing and hence did not necessitate graft revision. Both intraoperative fluorescence imaging and transit-time flowmetry confirmed persistent poor flow in 8 (3%) grafts in 8 (8%) patients that necessitated graft revision. However, in a further 10 (3.8%) grafts in 10 (10%) patients, transit-time flowmetry indicated persistently poor flows on the basis of mean graft flow and pulsatility index values, whereas the intraoperative fluorescence imaging system demonstrated satisfactory flow. These grafts were not revised. CONCLUSIONS: In most patients, both intraoperative fluorescence imaging and transit-time flowmetry are useful to confirm intraoperative graft patency. However, in a small proportion of patients (10%), graft patency assessment with transit-time flowmetry alone might prompt unnecessary graft revision.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Angiofluoresceinografia/métodos , Oclusão de Enxerto Vascular/diagnóstico , Reologia/métodos , Idoso , Velocidade do Fluxo Sanguíneo , Corantes , Feminino , Humanos , Verde de Indocianina , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Grau de Desobstrução Vascular
7.
J Thorac Cardiovasc Surg ; 128(2): 238-44, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15282460

RESUMO

BACKGROUND: Early graft failure is a common cause of cardiac mortality and morbidity after coronary artery bypass grafting, but there is little information on its natural incidence. Furthermore, there is particular concern about graft patency in off-pump coronary artery bypass grafting and total arterial grafting. METHODS: We performed a prospective observational study to assess intraoperative graft patency in patients undergoing off-pump and on-pump coronary artery bypass grafting, who also underwent total arterial grafting. We used an intraoperative imaging system, SPY (Novadaq Technologies Inc), based on the fluorescent properties of indocyanine green dye. RESULTS: We assessed the intraoperative graft patency of 533 conduits in 200 patients. The mean number of grafts was 2.7 per patient. Of these patients, 155 (78%) had off-pump coronary artery bypass grafting, and 45 (22%) had on-pump coronary artery bypass grafting. Overall, 161 (80%) had total arterial grafting, with composite arterial grafting performed in 120 (60%) patients. Fluorescence, confirming graft patency, was observed in all but 8 (1.5%) conduits in 8 (4%) patients, necessitating graft revision. Six (3.9%) and 2 (4.4%) of these patients, respectively, had off-pump coronary artery bypass grafting and on-pump coronary artery bypass grafting. CONCLUSION: Intraoperative fluorescence imaging demonstrated a low (1.5%) but well-defined incidence of intraoperative graft failure, which affects around 4% of patients. This emphasizes the need for routine assessment of graft patency. Intraoperative fluorescence imaging permits detection and revision of failed grafts in the operating room. We found no difference in the incidence of failed grafts when comparing on-pump and off-pump total arterial grafting.


Assuntos
Anastomose de Artéria Torácica Interna-Coronária , Complicações Intraoperatórias/epidemiologia , Idoso , Feminino , Humanos , Incidência , Anastomose de Artéria Torácica Interna-Coronária/efeitos adversos , Anastomose de Artéria Torácica Interna-Coronária/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Grau de Desobstrução Vascular
8.
Ann Thorac Surg ; 75(3): 870-3, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12645709

RESUMO

BACKGROUND: Early graft failure is a common cause of cardiac morbidity and mortality after coronary artery bypass grafting (CABG), and there is particular concern about graft patency in off-pump CABG. We describe our preliminary experience with a novel imaging technique (the SPY system), based on fluorescence of Indocyanine Green when exposed to near infrared light, for the intraoperative assessment of coronary graft patency. METHODS: Graft patency was assessed in patients undergoing off-pump and on-pump total arterial revascularization. The imaging technique requires injection of a 1-mL bolus of Indocyanine Green into the central venous line, followed by imaging with the SPY system. RESULTS: We assessed intraoperative graft patency in 213 conduits in 84 patients (mean, 2.54 grafts per patient), of which, 65 (77%) were done off-pump. It took approximately 3 minutes to image each graft. Skeletonized conduits provided better visualization than pedicled ones. Fluorescence, confirming graft patency, was observed in all but four (1.9%) conduits in 4 (5%) patients. In these latter cases, graft revision was necessitated. CONCLUSIONS: Fluorescence imaging of coronary grafts using the SPY is a uniquely simple, safe, noninvasive, and reproducible technique for intraoperative confirmation of graft patency. In 4 patients, it necessitated revision of the initial intraoperative procedure. Quantification of graft flow would enhance the value of the system.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Reestenose Coronária/diagnóstico , Angiofluoresceinografia , Oclusão de Enxerto Vascular/diagnóstico , Verde de Indocianina , Idoso , Artérias/transplante , Ponte Cardiopulmonar , Humanos , Complicações Intraoperatórias/diagnóstico , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos , Sensibilidade e Especificidade , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA