Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
JACC Heart Fail ; 3(11): 849-56, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26454842

RESUMO

OBJECTIVES: The study sought to characterize patterns in the HeartWare (HeartWare Inc., Framingham, Massachusetts) ventricular assist device (HVAD) log files associated with successful medical treatment of device thrombosis. BACKGROUND: Device thrombosis is a serious adverse event for mechanical circulatory support devices and is often preceded by increased power consumption. Log files of the pump power are easily accessible on the bedside monitor of HVAD patients and may allow early diagnosis of device thrombosis. Furthermore, analysis of the log files may be able to predict the success rate of thrombolysis or the need for pump exchange. METHODS: The log files of 15 ADVANCE trial patients (algorithm derivation cohort) with 16 pump thrombus events treated with tissue plasminogen activator (tPA) were assessed for changes in the absolute and rate of increase in power consumption. Successful thrombolysis was defined as a clinical resolution of pump thrombus including normalization of power consumption and improvement in biochemical markers of hemolysis. Significant differences in log file patterns between successful and unsuccessful thrombolysis treatments were verified in 43 patients with 53 pump thrombus events implanted outside of clinical trials (validation cohort). RESULTS: The overall success rate of tPA therapy was 57%. Successful treatments had significantly lower measures of percent of expected power (130.9% vs. 196.1%, p = 0.016) and rate of increase in power (0.61 vs. 2.87, p < 0.0001). Medical therapy was successful in 77.7% of the algorithm development cohort and 81.3% of the validation cohort when the rate of power increase and percent of expected power values were <1.25% and 200%, respectively. CONCLUSIONS: Log file parameters can potentially predict the likelihood of successful tPA treatments and if validated prospectively, could substantially alter the approach to thrombus management.


Assuntos
Fibrinolíticos/administração & dosagem , Insuficiência Cardíaca/terapia , Transplante de Coração , Coração Auxiliar/efeitos adversos , Trombose/tratamento farmacológico , Trombose/etiologia , Ativador de Plasminogênio Tecidual/administração & dosagem , Ensaios Clínicos como Assunto , Humanos , Resultado do Tratamento
2.
J Biomech Eng ; 137(5): 051001, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25612301

RESUMO

As major extracellular matrix components, elastin, and collagen play crucial roles in regulating the mechanical properties of the aortic wall and, thus, the normal cardiovascular function. The mechanical properties of aorta, known to vary with age and multitude of diseases as well as the proximity to the heart, have been attributed to the variations in the content and architecture of wall constituents. This study is focused on the role of layer-specific collagen undulation in the variation of mechanical properties along the porcine descending thoracic aorta. Planar biaxial tensile tests are performed to characterize the hyperelastic anisotropic mechanical behavior of tissues dissected from four locations along the thoracic aorta. Multiphoton microscopy is used to image the associated regional microstructure. Exponential-based and recruitment-based constitutive models are used to account for the observed mechanical behavior while considering the aortic wall as a composite of two layers with independent properties. An elevated stiffness is observed in distal regions compared to proximal regions of thoracic aorta, consistent with sharper and earlier collagen recruitment estimated for medial and adventitial layers in the models. Multiphoton images further support our prediction that higher stiffness in distal regions is associated with less undulation in collagen fibers. Recruitment-based models further reveal that regardless of the location, collagen in the media is recruited from the onset of stretching, whereas adventitial collagen starts to engage with a delay. A parameter sensitivity analysis is performed to discriminate between the models in terms of the confidence in the estimated model parameters.


Assuntos
Aorta Torácica/metabolismo , Colágeno/metabolismo , Fenômenos Mecânicos , Suínos , Animais , Fenômenos Biomecânicos , Elastina/metabolismo
3.
Biophys J ; 106(12): 2684-92, 2014 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-24940786

RESUMO

The complex network structure of elastin and collagen extracellular matrix (ECM) forms the primary load bearing components in the arterial wall. The structural and mechanobiological interactions between elastin and collagen are important for properly functioning arteries. Here, we examined the elastin and collagen organization, realignment, and recruitment by coupling mechanical loading and multiphoton imaging. Two-photon excitation fluorescence and second harmonic generation methods were performed with a multiphoton video-rate microscope to capture real time changes to the elastin and collagen structure during biaxial deformation. Enzymatic removal of elastin was performed to assess the structural changes of the remaining collagen structure. Quantitative analysis of the structural changes to elastin and collagen was made using a combination of two-dimensional fast Fourier transform and fractal analysis, which allows for a more complete understanding of structural changes. Our study provides new quantitative evidence, to our knowledge on the sequential engagement of different arterial ECM components in response to mechanical loading. The adventitial collagen exists as large wavy bundles of fibers that exhibit fiber engagement after 20% strain. The medial collagen is engaged throughout the stretching process, and prominent elastic fiber engagement is observed up to 20% strain after which the engagement plateaus. The fiber orientation distribution functions show remarkably different changes in the ECM structure in response to mechanical loading. The medial collagen shows an evident preferred circumferential distribution, however the fiber families of adventitial collagen are obscured by their waviness at no or low mechanical strains. Collagen fibers in both layers exhibit significant realignment in response to unequal biaxial loading. The elastic fibers are much more uniformly distributed and remained relatively unchanged due to loading. Removal of elastin produces similar structural changes in collagen as mechanical loading. Our study suggests that the elastic fibers are under tension and impart an intrinsic compressive stress on the collagen.


Assuntos
Artérias/metabolismo , Colágeno/metabolismo , Elastina/metabolismo , Matriz Extracelular/metabolismo , Animais , Fenômenos Biomecânicos , Análise de Fourier , Fractais , Microscopia de Fluorescência por Excitação Multifotônica , Ligação Proteica , Sus scrofa
4.
PLoS One ; 8(12): e81951, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24358135

RESUMO

Previously we have shown that gradual changes in the structure of elastin during an elastase treatment can lead to important transition stages in the mechanical behavior of arteries. However, in vivo arteries are constantly being loaded due to systolic and diastolic pressures and so understanding the effects of loading on the enzymatic degradation of elastin in arteries is important. With biaxial tensile testing, we measured the mechanical behavior of porcine thoracic aortas digested with a mild solution of purified elastase (5 U/mL) in the presence of a static stretch. Arterial mechanical properties and biochemical composition were analyzed to assess the effects of mechanical stretch on elastin degradation. As elastin is being removed, the dimensions of the artery increase by more than 20% in both the longitude and circumference directions. Elastin assays indicate a faster rate of degradation when stretch was present during the digestion. A simple exponential decay fitting confirms the time constant for digestion with stretch (0.11 ± 0.04 h(-1)) is almost twice that of digestion without stretch (0.069 ± 0.028 h(-1)). The transition from J-shaped to S-shaped stress vs. strain behavior in the longitudinal direction generally occurs when elastin content is reduced by about 60%. Multiphoton image analysis confirms the removal/fragmentation of elastin and also shows that the collagen fibers are closely intertwined with the elastin lamellae in the medial layer. After removal of elastin, the collagen fibers are no longer constrained and become disordered. Release of amorphous elastin during the fragmentation of the lamellae layers is observed and provides insights into the process of elastin degradation. Overall this study reveals several interesting microstructural changes in the extracellular matrix that could explain the resulting mechanical behavior of arteries with elastin degradation.


Assuntos
Aorta Torácica/metabolismo , Elastina/metabolismo , Matriz Extracelular/metabolismo , Elastase Pancreática/metabolismo , Estresse Mecânico , Animais , Fenômenos Biomecânicos/fisiologia , Elasticidade , Modelos Biológicos , Suínos
5.
Phys Rev Lett ; 110(16): 168101, 2013 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-23679639

RESUMO

Elastin is an intriguing extracellular matrix protein present in all connective tissues of vertebrates, rendering essential elasticity to connective tissues subjected to repeated physiological stresses. Using piezoresponse force microscopy, we show that the polarity of aortic elastin is switchable by an electrical field, which may be associated with the recently discovered biological ferroelectricity in the aorta. More interestingly, it is discovered that the switching in aortic elastin is largely suppressed by glucose treatment, which appears to freeze the internal asymmetric polar structures of elastin, making it much harder to switch, or suppressing the switching completely. Such loss of ferroelectricity could have important physiological and pathological implications from aging to arteriosclerosis that are closely related to glycation of elastin.


Assuntos
Aorta/química , Aorta/fisiologia , Elastina/química , Elastina/fisiologia , Glucose/química , Glucose/farmacologia , Animais , Aorta/efeitos dos fármacos , Fenômenos Eletromagnéticos , Microscopia de Força Atômica/métodos , Suínos
6.
Ann Biomed Eng ; 41(7): 1528-38, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23297000

RESUMO

Arteries are composed of multiple constituents that endow the wall with proper structure and function. Many vascular diseases are associated with prominent mechanical and biological alterations in the wall constituents. In this study, planar biaxial tensile test data of elastase-treated porcine aortic tissue (Chow et al. in Biomech Model Mechanobiol 2013) is re-examined to characterize the altered mechanical behavior at multiple stages of digestion through constitutive modeling. Exponential-based as well as recruitment-based strain energy functions are employed and the associated constitutive parameters for individual digestion stages are identified using nonlinear parameter estimation. It is shown that when the major portion of elastin is degraded from a cut-open artery in the load-free state, the embedded collagen fibers are recruited at lower stretch levels under biaxial loads, leading to a rapid stiffening behavior of the tissue. Multiphoton microscopy illustrates that the collagen waviness decreases significantly with the degradation time, resulting in a rapid recruitment when the tissue is loaded. It is concluded that even when residual stresses are released, there exists an intrinsic mechanical interaction between arterial elastin and collagen that determines the mechanics of arteries and carries important implications to vascular mechanobiology.


Assuntos
Aorta Torácica/fisiologia , Colágeno/fisiologia , Elastina/fisiologia , Animais , Fenômenos Biomecânicos , Técnicas In Vitro , Modelos Biológicos , Suínos
7.
Biomech Model Mechanobiol ; 12(2): 361-72, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22623109

RESUMO

Aortic aneurysm is an important clinical condition characterized by common structural changes such as the degradation of elastin, loss of smooth muscle cells, and increased deposition of fibrillary collagen. With the goal of investigating the relationship between the mechanical behavior and the structural/biochemical composition of an artery, this study used a simple chemical degradation model of aneurysm and investigated the progressive changes in mechanical properties. Porcine thoracic aortas were digested in a mild solution of purified elastase (5 U/mL) for 6, 12, 24, 48, and 96 h. Initial size measurements show that disruption of the elastin structure leads to increased artery dilation in the absence of periodic loading. The mechanical properties of the digested arteries, measured with a biaxial tensile testing device, progress through four distinct stages termed (1) initial-softening, (2) elastomer-like, (3) extensible-but-stiff, and (4) collagen-scaffold-like. While stages 1, 3, and 4 are expected as a result of elastin degradation, the S-shaped stress versus strain behavior of the aorta resulting from enzyme digestion has not been reported previously. Our results suggest that gradual changes in the structure of elastin in the artery can lead to a progression through different mechanical properties and thus reveal the potential existence of an important transition stage that could contribute to artery dilation during aneurysm formation.


Assuntos
Aorta/patologia , Elastina/metabolismo , Animais , Aorta/efeitos dos fármacos , Fenômenos Biomecânicos/efeitos dos fármacos , Fenômenos Biomecânicos/fisiologia , Colágeno/metabolismo , Técnicas In Vitro , Elastase Pancreática/farmacologia , Solubilidade , Estresse Mecânico , Sus scrofa
8.
Phys Rev Lett ; 108(7): 078103, 2012 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-22401260

RESUMO

Many biological tissues are piezoelectric and pyroelectric with spontaneous polarization. Ferroelectricity, however, has not been reported in soft biological tissues yet. Using piezoresponse force microscopy, we discover that the porcine aortic walls are not only piezoelectric, but also ferroelectric, with the piezoelectric coefficient in the order of 1 pm/V and coercive voltage approximately 10 V. Through detailed switching spectroscopy mapping and relaxation studies, we also find that the polarization of the aortic walls is internally biased outward, and the inward polarization switched by a negative voltage is unstable, reversing spontaneously to the more stable outward orientation shortly after the switching voltage is removed. The discovery of ferroelectricity in soft biological tissues adds an important dimension to their biophysical properties, and could have physiological implications as well.


Assuntos
Aorta/ultraestrutura , Eletricidade , Eletroquímica , Compostos Férricos/química , Microscopia de Força Atômica , Animais , Teste de Materiais , Suínos
9.
J Biomech Eng ; 133(11): 111009, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22168741

RESUMO

Pulmonary obstruction occurs in many common forms of congenital heart disease. In this study, pulmonary artery (PA) banding is used as a model for pulmonary stenosis. Significant remodeling of the vascular bed occurs as a result of a prolonged narrowing of the PAs, and here we quantify the biophysical and molecular changes proximal and distal to the obstruction. Main and branch PAs are harvested from banded and sham rabbits and their mechanical properties are assessed using a biaxial tensile tester. Measurements defined as initial and stiff slopes are taken, assuming a linear region at the start and end of the J-shaped stress-strain curves, along with a transitional knee point. Collagen, elastin assays, Movat's pentachrome staining, and Doppler protocols are used to quantify biochemical, structural, and physiological differences. The banded main PAs have significantly greater initial slopes while banded branch PAs have lower initial slopes; however, this change in mechanical behavior cannot be explained by the assay results as the elastin content in both main and branch PAs is not significantly different. The stiff slopes of the banded main PAs are higher, which is attributed to the significantly greater amounts of insoluble collagen. Shifting of the knee points reveals a decreased toe region in the main PAs but an opposite trend in the branch PAs. The histology results show a loss of integrity of the media, increase in ground substance, and dispersion of collagen in the banded tissue samples. This indicates other structural changes could have led to the mechanical differences in banded and normal tissue.


Assuntos
Estenose da Valva Pulmonar/patologia , Estenose da Valva Pulmonar/fisiopatologia , Remodelação das Vias Aéreas , Animais , Fenômenos Biomecânicos , Colágeno/química , Colágeno/fisiologia , Modelos Animais de Doenças , Ecocardiografia Doppler , Hemodinâmica , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/patologia , Artéria Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/diagnóstico por imagem , Coelhos , Estresse Mecânico , Resistência à Tração
10.
Int J Biomater ; 2011: 172389, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21876695

RESUMO

Collagen type I scaffolds are commonly used due to its abundance, biocompatibility, and ubiquity. Most applications require the scaffolds to operate under mechanical stresses. Therefore understanding and being able to control the structural-functional integrity of collagen scaffolds becomes crucial. Using a combined experimental and modeling approach, we studied the structure and function of Type I collagen gel with the effects of spatial fiber alignment and crosslinking. Aligned collagen scaffolds were created through the flow of magnetic particles enmeshed in collagen fibrils to mimic the anisotropy seen in native tissue. Inter- and intra- molecular crosslinking was modified chemically with Genipin to further improve the stiffness of collagen scaffolds. The anisotropic mechanical properties of collagen scaffolds were characterized using a planar biaxial tensile tester and parallel plate rheometer. The tangent stiffness from biaxial tensile test is two to three orders of magnitude higher than the storage moduli from rheological measurements. The biphasic nature of collagen gel was discussed and used to explain the mechanical behavior of collagen scaffolds under different types of mechanical tests. An anisotropic hyperelastic constitutive model was used to capture the characteristics of the stress-strain behavior exhibited by collagen scaffolds.

11.
J Surg Res ; 171(2): 434-42, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20701927

RESUMO

BACKGROUND: Temporary cold storage is a common procedure for preserving tissues for a short time before using them in a clinical or experimental setting. The process of storing tissues at refrigeration or freezing temperatures can affect the mechanical properties of the tissue. Previous studies were limited to uniaxial tensile tests and did not have substantial explanations for what was structurally occurring in the tissue to account for the changes in mechanical properties. MATERIALS AND METHODS: This study involved biaxial tensile testing of bovine thoracic aortas that had been stored at common storage temperatures (4°C, -20°C, or -80°C) for three different time points (48 h, 1 wk, or 3 wk). The slopes of the initial and stiff region of the stress-strain curves were measured. The knee point of the stress-strain curves was also determined. Collagen content before and after storage was quantified using a Sircol collagen assay kit. RESULTS: The stored arteries showed decreased initial slope and increased stiff slope after 48 h of 4°C refrigeration. The -20°C and -80°C storage conditions had similar initial slopes compared with the fresh ones but an increase in the stiff slope. There was also a significant shift of the knee point to a higher strain and stress. The soluble and insoluble collagen content decreased significantly due to storage but the percentage of cross-linked collagen was unchanged. CONCLUSIONS: Cold storage causes several changes in the mechanical properties due to structural and biochemical changes in the tissue. Overall, freezing protocols (either -20°C or -80°C) are suggested over refrigeration (4°C) for maintaining the initial stress-strain behavior.


Assuntos
Aorta Torácica/metabolismo , Aorta Torácica/fisiologia , Colágeno/metabolismo , Reagentes de Ligações Cruzadas/metabolismo , Criopreservação , Animais , Fenômenos Biomecânicos/fisiologia , Bovinos , Modelos Biológicos , Estresse Mecânico , Resistência à Tração/fisiologia , Suporte de Carga/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA